Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLEXIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Deformation of multilayer flexible electronics subjected to torque

Flexibility is one of remarkable characteristics of flexible electronics. Therefore, the analysis of flexible electronics deformation caused by external torques will help its design. In this work, analytical derivation is conducted for flexible electronics treated as multilayer structures. In experiments, an electric motor under computer control exerts a torque to generate torsion, whose twist angles are obtained by using both optical encoder measurement and theoretical calculation. Comparisons are made between experimental and theoretical results for bare PEN (polyethylene naphthalate) substrates of different sizes, multilayer PET (polyethylene terephthalate) substrates, and ITO (indium tin oxide)-coated PET substrates. Finally, a laser displacement sensor is used to measure the out-of-plane deformation for validating the proposed theoretical model.

36 MATERIALS SCIENCE↗

Approaches to Encapsulation of Flexible CIGS Cells

Thin-film solar cells based on CIGS are being considered for large scale power plants as well as building integrated photovoltaic (BIPV) applications. Past studies indicate that CIGS cells degrade rapidly when exposed to moisture. As a result, an effective approach to encapsulation is required for CIGS cells to satisfy the international standard IEC 61646. CIGS modules fabricated for use in large power plants can be encapsulated with glass sheets on the top and bottom surfaces and can be effectively sealed around the edges. In the case of BIPV applications, however, it is desirable to utilize CIGS cells grown on flexible substrates, both for purposes of achieving reduced weight and for cases involving non-flat surfaces. For these cases, approaches to encapsulation must be compatible with the flexible substrate requirement. Even in the case of large power plants, the glass-to-glass approach to encapsulation may eventually be considered too costly. We are investigating encapsulation of flexible CIGS cells by lamination. Sheets of PET or PEN coated with multilayer barrier coatings are used to laminate the flexible cells. Results are discussed for laminated cells from two CIGS manufacturers. In both cases, the cell efficiency decreases less than 10% after 1000 hours of exposure to an environment of 85C/85%RH. This paper discusses these two approaches, reviews results achieved with cells and mini-modules fabricated by the former Shell Solar, Industries (SSI) stressed at 60C/90%RH (60/90), and recent studies of encapsulated IEC cells subjected to an environment of 85ºC/85%RH (85/85).

14 SOLAR ENERGY↗

Aging Affects Dopaminergic Neural Mechanisms of Cognitive Flexibility

Aging is accompanied by profound changes in the brain’s dopamine system that affect cognitive function. Evidence of powerful individual differences in cognitive aging has sharpened focus on identifying biological factors underlying relative preservation versus vulnerability to decline. Dopamine represents a key target in these efforts. Alterations of dopamine receptors and dopamine synthesis are seen in aging, with receptors generally showing reduction and synthesis demonstrating increases. Using the PET tracer 6-[ 18 F]fluoro-L- m -tyrosine, we found strong support for upregulated striatal dopamine synthesis capacity in healthy older adult humans free of amyloid pathology, relative to young people. We next used fMRI to define the functional impact of elevated synthesis capacity on cognitive flexibility, a core component of executive function. We found clear evidence in young adults that low levels of synthesis capacity were suboptimal, associated with diminished cognitive flexibility and altered frontoparietal activation relative to young adults with highest synthesis values. Critically, these relationships between dopamine, performance, and activation were transformed in older adults with higher synthesis capacity. Variability in synthesis capacity was related to intrinsic frontoparietal functional connectivity across groups, suggesting that striatal dopamine synthesis influences the tuning of networks underlying cognitive flexibility. Altogether, these findings define striatal dopamine’s association with cognitive flexibility and its neural underpinnings in young adults, and reveal the alteration in dopamine-related neural processes in aging.

60 APPLIED LIFE SCIENCES↗

Impact of Generator Flexibility on Electric System Costs and Integration of Renewable Energy

Flexibility of traditional generators plays an important role in accommodating the increased variability and uncertainty of wind and solar on the electric power system. Increased flexibility can be achieved with changes to operational practices or upgrades to existing generation. One challenge is in understanding the value of increasing flexibility, and how this value may change given higher levels of variable generation. This study uses a commercial production cost model to measure the impact of generator flexibility on the integration of wind and solar generators. We use a system that is based on two balancing areas in the Western United States with a range of wind and solar penetrations between 15% and 60%, where instantaneous penetration of wind and solar is limited to 80%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Capturing the Impact of Storage and Other Flexible Technologies on Electric System Planning

Power systems of the future are likely to require additional flexibility. This has been well studied from an operational perspective, but has been more difficult to incorporate into capacity expansion models (CEMs) that study investment decisions on the decadal scale. There are two primary reasons for this. First, the necessary input data, including cost and resource projections, for flexibility options like demand response and storage are significantly uncertain. Second, it is computationally difficult to represent both investment and operational decisions in detail, the latter being necessary to properly value system flexibility, in CEMs for realistically sized systems. In this work, we extend a particular CEM, NREL's Resource Planning Model (RPM), to address the latter issue by better representing variable generation impacts on operations, and then adding two flexible technologies to RPM's suite of investment decisions: interruptible load and utility-scale storage. This work does not develop full suites of input data for these technologies, but is rather methodological and exploratory in nature. We thus exercise these new investment decisions in the context of exploring price points and value streams needed for significant deployment in the Western Interconnection by 2030. Our study of interruptible load finds significant variation by location, year, and overall system conditions. Some locations find no system need for interruptible load even with low costs, while others build the most expensive resources offered. System needs can include planning reserve capacity needs to ensure resource adequacy, but there are also particular cases in which spinning reserve requirements drive deployment. Utility-scale storage is found to require deep cost reductions to achieve wide deployment and is found to be more valuable in some locations with greater renewable deployment. Differences between more solar- and wind-reliant regions are also found: Storage technologies with lower energy capacities are deployed to support solar deployment, and higher energy capacity technologies support wind. Finally, we identify potential future research and areas of improvement to build on this initial analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Integrated Energy Systems Prototype Human-System Interface for a Steam Extraction Loop System to Support Joint Electricity-Hydrogen Flexible Operations

Due to increasing economic competition from renewables and combined-cycle natural gas plants, nuclear power plants are looking toward flexible operations to enhance their cost competitiveness. The Integrated Energy Systems project under the Light Water Reactor Sustainability program of the U.S. Department of Energy focuses on joint electricity-hydrogen flexible operations. Joint electricity-hydrogen flexible operations entail the nuclear power plant diverting thermal energy via main steam to a hydrogen production plant located nearby. The steam serves to enhance the efficiency of the hydrogen production. Furthermore, high temperature electrolysis requires a large amount of electricity, which the plant can also provide. The plant provides steam and electricity to the hydrogen plant throughout the day, but during peak demand hours the nuclear power plant returns to solely providing electricity to meet the high demand. Through this flexible concept of operations, the plant can optimize the thermal energy it produces without having to maneuver the power of the plant. This report documents the human factors process to design and develop a prototype human-system interface for the steam extraction loop that serves as the conduit between the nuclear power plant and the adjacent hydrogen plant. The design process followed the human factors guidelines set by NUREG-0711, Human Factors Engineering Program Review Model (O’Hara, Higgins, & Fleger, 2012), and expanded upon by the Guideline for Operational Nuclear Usability and Knowledge Elicitation (GONUKE; Boring, Ulrich, Joe, & Lew, 2015; Boring, Lew, & Ulrich, 2016). The design process entailed operator interviews to determine the concept of operations for the steam extraction loop, a review and adaptation of digital interface design concepts developed by the team in prior projects, an iterative design process, and reviews conducted by both operators and human factors experts. Several versions of the prototype human-system interface were developed. Operators were interviewed to determine what design features they found useful and would like to see in the interface. The design underwent a review by human factors experts against NUREG-0700, Human Interface Design Review Guidelines (U.S. Nuclear Regulatory Commission, 2019), to ensure compliance with the latest human factors standards for digital interfaces in nuclear applications. The design was then prototyped as a functional windows-based application integrated with the Generic Pressurized Water Reactor simulator modified to include the steam extraction loop. The simulation is supported by the Human Systems Simulation Laboratory at Idaho National Laboratory, which supports operator-in-the-loop testing. This is an ongoing project and the next phase of the project entails performing an operator-in-the-loop usability study to evaluate the interface and examine the proposed concept of operations to extraction steam from the nuclear power plant for delivery to the coupled hydrogen production plant.

99 GENERAL AND MISCELLANEOUS↗

End-Use Savings Shapes Measure Documentation: Dispatch Schedule Generation for Demand Flexibility Measures

This supplemental document describes the methodology used for determining the dispatch timing of various EUSS demand flexibility measures. Demand flexibility measures are designed to reduce/dispatch electricity demand in buildings during especially beneficial/critical times. The method used in this work utilizes predictions of building loads to generate a schedule that reflects the periods when the building's daily peak load occurs to support decision making in demand flexibility measures. The dispatch schedule generation method described in this document creates an hourly schedule that includes a load dispatch (peak) window for each day for a whole year based on load prediction, with options using different prediction methods: perfect prediction, bin-sampling method, fixed schedule, and outdoor air temperature (OAT)-based prediction method. The perfect prediction method performs a simulation to obtain the annual load profile as predicted load, representing the scenario of perfect load prediction. The bin-sampling method (1) categorizes days into representative bins by temperature characteristics, (2) performs simulations on sample days from each of those bins to create representative (or predicted) load, and (3) assigns representative loads for all days in a year based on the bin categorization. The fixed schedule method defines uniform start and end time of peak window with assumed fixed daily peak time, for all days in a season or a year. The OAT-based prediction method uses the statistics of OAT (minimum and maximum) as the indicators of peak load, with specified delay response time from building loads to temperature. Given the load prediction, daily peak periods are determined as a time window with specified length in each day that include the predicted daily peak load and with a secondary rule such as maximizing energy saving potential. The dispatch schedule generation method is not a standalone measure and is intended to be combined with other demand flexibility measures that could leverage the peak schedule and apply demand controls on specific systems or devices for demand response, such as measures described in "Measure Documentation - Thermostat Control for Load Shedding" and "Measure Documentation - Thermostat Control for Load Shifting".

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Enterprise Derivative Application: Flexible Software for Optimizing Manufacturing Processes

The Enterprise Derivative Application (EDA) implements the enterprise-derivative analysis for optimization of an industrial process (Allgood and Manges, 2001). It is a tool to help industry planners choose the most productive way of manufacturing their products while minimizing their cost. Developed in MS Access, the application allows users to input initial data ranging from raw material to variable costs and enables the tracking of specific information as material is passed from one process to another. Energy-derivative analysis is based on calculation of sensitivity parameters. For the specific application to a steel production process these include: the cost to product sensitivity, the product to energy sensitivity, the energy to efficiency sensitivity, and the efficiency to cost sensitivity. Using the EDA, for all processes the user can display a particular sensitivity or all sensitivities can be compared for all processes. Although energy-derivative analysis was originally designed for use by the steel industry, it is flexible enough to be applied to many other industrial processes. Examples of processes where energy-derivative analysis would prove useful are wireless monitoring of processes in the petroleum cracking industry and wireless monitoring of motor failure for determining the optimum time to replace motor parts. One advantage of the MS Access-based application is its flexibility in defining the process flow and establishing the relationships between parent and child process and products resulting from a process. Due to the general design of the program, a process can be anything that occurs over time with resulting output (products). So the application can be easily modified to many different industrial and organizational environments. Another advantage is the flexibility of defining sensitivity parameters. Sensitivities can be determined between all possible variables in the process flow as a function of time. Thus the dynamic development of the process can be tracked over time and optimized. EDA is a uniquely flexible and efficient way for planners to choose the most productive way of optimizing production while minimizing costs. The purpose of this document is to describe energy-derivative analysis and the operation of the application. The first section is an introduction of the concept, followed in Section 2 by a detailed description of the analysis approach. The third section provides a general overview of the operation of the application. The detailed description of the application is described in Section 4, using the still mill operation as an example. Conclusions regarding the utility of the EDA and the effectiveness of the implementation follow in Section 5. Appendix A describes details of setting up the process flow model and Appendix B provides information on overcoming an error that occurred in using the application on a PC that did not have Visual Basic installed.

02 PETROLEUM↗

Strategic Offering for Wind Power Producers Considering Energy and Flexible Ramping Products

The increasing deployments of renewable generation methods, such as wind, affects the flexibility of electric power system operating due to their inherent variability and uncertainty. To mitigate this, power systems need flexible resources. This paper investigates the potential for wind power to provide flexible ramping products in the real-time market, an additional value stream to the energy it provides. The proposed model for wind power’s strategic offering is formulated as a bi-level optimization problem with wind profit maximization at the upper level and the independent system operator’s economic dispatch—considering both the energy balance and the flexible ramping requirement to counter uncertainty—at the lower level. This bi-level model is converted to a mathematical program with equilibrium constraints (MPEC) by recasting the lower level problem with its Karush–Kuhn–Tucker optimality conditions. Then, through strong duality theory and the big-M method, the MPEC model is converted to a mixed-integer linear programming model. The opportunity cost and the price for wind power-providing ramping products are analyzed. Numerical examples based on a 5-bus network are presented to verify the proposed model and concept.

17 WIND ENERGY↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structural Basis of CO 2 Adsorption in a Flexible Metal-Organic Framework Material

This paper reports on the structural basis of CO 2 adsorption in a representative model of flexible metal-organic framework (MOF) material, Ni(1,2-bis(4-pyridyl)ethylene)[Ni(CN) 4 ] (NiBpene or PICNIC-60). NiBpene exhibits a CO 2 sorption isotherm with characteristic hysteresis and features on the desorption branch that can be associated with discrete structural changes. Various gas adsorption effects on the structure are demonstrated for CO 2 with respect to N 2 , CH 4 and H 2 under static and flowing gas pressure conditions. For this complex material, a combination of crystal structure determination and density functional theory (DFT) is needed to make any real progress in explaining the observed structural transitions during adsorption/desorption. Possible enhancements of CO 2 gas adsorption under supercritical pressure conditions are considered, together with the implications for future exploitation. In situ operando small-angle neutron and X-ray scattering, neutron diffraction and X-ray diffraction under relevant gas pressure and flow conditions are discussed with respect to previous studies, including ex situ, a priori single-crystal X-ray diffraction structure determination. The results show how this flexible MOF material responds structurally during CO 2 adsorption; single or dual gas flow results for structural change remain similar to the static (Sieverts) adsorption case, and supercritical CO 2 adsorption results in enhanced gas uptake. Insights are drawn for this representative flexible MOF with implications for future flexible MOF sorbent design.

36 MATERIALS SCIENCE↗

Ultra-Thin, Flexible Electronics

Thinned die can be used to realize ultra-thin flexible electronics for applications such as conformal and wearable electronics. Three techniques have been developed to achieve this goal using thinned die: die flip chip bonded onto flexible substrates, die laminated onto LCP films, and die embedded in polyimide. A key to achieving each of these techniques is the thinning of die to a thickness of 50 microns or thinner. Conventional CMP processing can be used to thin to 50 microns. At 50 microns, the active die become flexible and must be handled by temporarily bonding them to a holder die, for further processing. Once bonded face down to the holder die, the active die can be further thinned by DRIE etching the exposed backside. The thinned die can then been packaged in or on the flexible substrate.

electronics packaging↗

Identifying Functional Requirements for Flexible Airspace Management Concept Using Human-In-The-Loop Simulations

Flexible Airspace Management (FAM) is a mid- term Next Generation Air Transportation System (NextGen) concept that allows dynamic changes to airspace configurations to meet the changes in the traffic demand. A series of human-in-the-loop (HITL) studies have identified procedures and decision support requirements needed to implement FAM. This paper outlines a suggested FAM procedure and associated decision support functionality based on these HITL studies. A description of both the tools used to support the HITLs and the planned NextGen technologies available in the mid-term are presented and compared. The mid-term implementation of several NextGen capabilities, specifically, upgrades to the Traffic Management Unit (TMU), the initial release of an en route automation system, the deployment of a digital data communication system, a more flexible voice communications network, and the introduction of a tool envisioned to manage and coordinate networked ground systems can support the implementation of the FAM concept. Because of the variability in the overall deployment schedule of the mid-term NextGen capabilities, the dependency of the individual NextGen capabilities are examined to determine their impact on a mid-term implementation of FAM. A cursory review of the different technologies suggests that new functionality slated for the new en route automation system is a critical enabling technology for FAM, as well as the functionality to manage and coordinate networked ground systems. Upgrades to the TMU are less critical but important nonetheless for FAM to be fully realized. Flexible voice communications network and digital data communication system could allow more flexible FAM operations but they are not as essential.

dynamic airspace configuration↗

Flexible Proteins at the Origin of Life

Almost all modern proteins possess well-defined, relatively rigid scaffolds that provide structural preorganization for desired functions. Such scaffolds require the sufficient length of a polypeptide chain and extensive evolutionary optimization. How ancestral proteins attained functionality, even though they were most likely markedly smaller than their contemporary descendants, remains a major, unresolved question in the origin of life. On the basis of evidence from experiments and computer simulations, we argue that at least some of the earliest water-soluble and membrane proteins were markedly more flexible than their modern counterparts. As an example, we consider a small, evolved in vitro ligase, based on a novel architecture that may be the archetype of primordial enzymes. The protein does not contain a hydrophobic core or conventional elements of the secondary structure characteristic of modern water-soluble proteins, but instead is built of a flexible, catalytic loop supported by a small hydrophilic core containing zinc atoms. It appears that disorder in the polypeptide chain imparts robustness to mutations in the protein core. Simple ion channels, likely the earliest membrane protein assemblies, could also be quite flexible, but still retain their functionality, again in contrast to their modern descendants. This is demonstrated in the example of antiamoebin, which can serve as a useful model of small peptides forming ancestral ion channels. Common features of the earliest, functional protein architectures discussed here include not only their flexibility, but also a low level of evolutionary optimization and heterogeneity in amino acid composition and, possibly, the type of peptide bonds in the protein backbone.

Flexible protein↗

Flexibility in 21st Century Power Systems (Fact Sheet)

Flexibility of operation--the ability of a power system to respond to change in demand and supply--is a characteristic of all power systems. Flexibility is especially prized in twenty-first century power systems, with higher levels of grid-connected variable renewable energy (primarily, wind and solar). Sources of flexibility exist--and can be enhanced--across all of the physical and institutional elements of the power system, including system operations and markets, demand side resources and storage; generation; and transmission networks. Accessing flexibility requires significant planning to optimize investments and ensure that both short- and long-time power system requirements are met.

21ST CENTURY POWER SYSTEMS↗

Damage Evolution of Double-Sided Copper Conductor on Multi-layer Flexible Substrate Under Bending

Abstract—Thin-film conductors continue to play an important role in flexible electronics, and thus, the performance and reliability of such conductors under mechanical loading such as stretch, bend, and twist need to be studied through experiments as well as simulations. This paper focuses on the damage evolution of the thin-film conductors under cyclic bending. Four types of double-sided copper conductors: straight trace without coverlay, straight trace with coverlay, notched trace without coverlay, and notched trace with coverlay on multi-layer substrates were studied in this work. The adaptive curvature flexure test method, which is suitable for thin-film bending, was employed in this work. Adaptive curvature flexure test is one where the flexible substrate with its conductor is positioned between two parallel plates, and the parallel plates are moved relative to each other such that the gap distance between the parallel plates changes in one of the configurations of the adaptive curvature flexure test. Different strain levels can be achieved easily in such an adaptive curvature flexure test by controlling the gap distance between the parallel plates. By subjecting flexible substrates with thin conductors to such bend tests, the fatigue life of the specimen was determined for different magnitudes of strain ranges. The results were then compared among the four types of conductors. Specimens were designed such that the conductors were placed on both sides of the substrate so that the one of the conductors would undergo tensile straining, while the other one would undergo compressive straining. It was shown that the fatigue life was highly dependent on the magnitude of strain range, and that the conductor on the compressive side failed sooner than that on the tensile side. The failed specimens were examined in a microscope at different number of cycles. Also, the resistance of the conductors, which is directly related to the reliability of thin-film conductors, was monitored in-situ during bending. The resistance change with the strain range change as well as the resistance progression with the number of cycles in tensile as well as compressive mode were determined, and such information is then used to create failure prediction models for thin-film conductors on flexible substrates.

damage evolution, flexible conductor, multi-layer ↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗