Recent advances in 3D SRF cavity-based quantum computing facility at the Fermilab SQMS Center

This talk will describe the most recent advances and progress in building an SRF cavity-based quantum computing facility at the Fermilab SQMS center. Several technical challenges had been successfully overcome to preserve the highest quality factors of SRF cavities in the presence of the sapphire chip holding the transmon qubit inside the cavity. The record values of the attained multicell cavity (2-cell, 9-cell)-qubit systems will be presented, as well as a variety of quantum operations realized with such systems, including the generation of large Fock states, coherent states, entangled mode-mode states etc. The quantum algorithms and computational problems being implemented on this 3D SQMS QPUs will be discussed as well.

Romanenko, Alexander [Fermilab]↗

Deploying and Operating CephFS for Scientific Applications at Fermilab

Fermilab has been running a Ceph cluster in production for several years to support high-throughput scientific computing. Our primary use case is CephFS, which serves interactive data analysis workloads, with growing interest in using RGW for scalable object storage of scientific datasets. In this talk, we'll share lessons learned from successfully deploying and maintaining our Ceph cluster with cephadm, including challenges faced, performance tuning, and operational practices. We'll also present custom tools we've developed to streamline monitoring and management and discuss how Ceph fits into our broader storage architecture for large-scale scientific research.

Peisker, Alison [Fermilab]↗

Noble Liquid Test Facility at Fermilab

The Noble Liquid Test Facility (NLTF) at Fermilab is a liquid argon detector R\&D facility open to the national and international HEP community. The facility consists of 4 permanent cryostats, ranging from 250L up to 3000L, open space for small open dewar testing, and an optical test stand facility capable of measuring the optical properties of materials and characterizing photon detectors. NLTF’s strongest advantage is its capability to provide ultra-pure LAr in a reliable manner. Its inline filters are capable of filtering all of the three biggest contaminants for standard LAr detectors, O$_2$ and H$_2$O down to $< 1$ppb and N$_2$ $< 1$ppm. This is critical for the users of the test stands as small levels of impurities can dramatically change the efficiency of LArTPCs for the collection of charge and light. The smallest cryostat is mainly used for material testing, a service provided to the international HEP community interested in understanding how the introduction of a specific material might affect the electron lifetime in LAr. The test stands can be equipped with a purity monitor, which allows measuring the electron lifetime in real time, as well as gas sampling and analyzing, and in the near future, local recirculation and filtering. The facility has hosted many successful R\&D projects, which have published their results in well-known journals and talks. A few examples of such projects are: NIR light production in LAr and GAr, the characterization of VUV metalenses, the testing of new filter media capable of filtering N$_2$ from LAr, high voltage studies and direct charge amplification in LAr, and various doping studies.

Blaszczyk, Flor María [Fermilab]↗

Single-Bunch Instabilities at the Fermilab Recycler Ring

Understanding and characterizing collective instabilities is critical for high-intensity operation at the Fermilab Recycler Ring. This work presents an application of the the Nested Head-Tail (NHT) formalism for modeling single-bunch transverse instabilities, incorporating analytical solutions to the resistive wall impedances in the absence of space charge. Predicted growth rates and mode structures are benchmarked against PyHEADTAIL simulations and ongoing experimental measurements. The experimental program includes studies of bare-machine instabilities at different machine parameters. These results support the understanding of naturally-occurring instabilities in the Recycler and contribute to the development of predictive tools for beam stability in future high-intensity configurations.

Gonzalez-Ortiz, Cristhian [Fermilab]↗

Automated RF Phase Adjustment for Beam Stabilization in the Fermilab Linac

The Fermilab Linac experiences longitudinal beam phase drift, leading to increased particle loss, conventionally cor- rected through labor-intensive manual RF adjustments. This project explores machine learning-based automation for drift correction, employing a prototype-based classification approach. Our model utilizes a 34-dimensional feature set (RF settings and BPM readings) and leverages a 7x27 response matrix for system modeling. To overcome limited real-world data, we generate synthetic data, enhancing model training and generalizability. Custom loss functions, including a sur- rogate energy-consistent loss and a temporal smoothness constraint, ensure physically plausible drift predictions. The goal is a robust system for autonomous phase adjustments, ensuring stable beam acceleration and reduced manual intervention.

Chichili, R. R. [U. Illinois, Chicago]↗

Status of the Short-Baseline Near Detector at Fermilab

The Short-Baseline Near Detector (SBND) is one of the Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors positioned along the axis of the Booster Neutrino Beam (BNB) at Fermilab, and is the near detector in the Short-Baseline Neutrino (SBN) Program. The detector has completed Run 1, successfully recording approximately 3 million neutrino interactions, and started Run 2 in the autumn of 2025. SBND is characterized by superb imaging capabilities and will record around 3 million neutrino interactions per year. Thanks to its unique combination of measurement resolution and statistics, SBND will soon carry out a rich program of neutrino interaction measurements and novel searches for physics beyond the Standard Model (BSM). As the near detector, it will enable the full potential of the SBN sterile neutrino program by performing a precise characterization of the unoscillated event rate and constraining the BNB flux and neutrino-argon cross-section systematic uncertainties. In this talk, the physics reach, current status, and future prospects of SBND are discussed.

Del Tutto, Marco [Fermilab]↗

Status of the Short-Baseline Near Detector at Fermilab

The Short-Baseline Near Detector (SBND) is one of the Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors positioned along the axis of the Booster Neutrino Beam (BNB) at Fermilab, and is the near detector in the Short-Baseline Neutrino (SBN) Program. The detector has completed Run 1, successfully recording approximately 3 million neutrino interactions, and started Run 2 in the autumn of 2025. SBND is characterized by superb imaging capabilities and will record around 3 million neutrino interactions per year. Thanks to its unique combination of measurement resolution and statistics, SBND will soon carry out a rich program of neutrino interaction measurements and novel searches for physics beyond the Standard Model (BSM). As the near detector, it will enable the full potential of the SBN sterile neutrino program by performing a precise characterization of the unoscillated event rate and constraining the BNB flux and neutrino-argon cross-section systematic uncertainties. In this talk, the physics reach, current status, and future prospects of SBND are discussed.

Del Tutto, Marco [Fermilab]↗

Advancing In-Situ Plasma Processing for SRF Cavities at Fermilab

This talk presents Fermilab’s experience with plasma processing applied to both elliptical and low-beta superconducting RF cavities. The development and implementation of the technique are compared across different geometries, with particular emphasis on constraints imposed by cryomodule assembly configurations. The talk also reports on systematic studies aimed at optimizing the processing recipe, including the exploration of various inert gas mixtures and oxygen concentrations. These results aim at providing guidance for tailoring plasma processing conditions to different cavity types and advancing plasma processing applicability in operational cryomodules.

Giaccone, Bianca [Fermilab] (ORCID:000000027275846↗

Advancing In-Situ Plasma Processing for SRF Cavities at Fermilab

This talk presents Fermilab’s experience with plasma processing applied to both elliptical and low-beta superconducting RF cavities. The development and implementation of the technique are compared across different geometries, with particular emphasis on constraints imposed by cryomodule assembly configurations. The talk also reports on systematic studies aimed at optimizing the processing recipe, including the exploration of various inert gas mixtures and oxygen concentrations. These results aim at providing guidance for tailoring plasma processing conditions to different cavity types and advancing plasma processing applicability in operational cryomodules.

Giaccone, Bianca [Fermilab] (ORCID:000000027275846↗

Fermilab complex upgrades and CLFV

I review the current status and future prospects of charged lepton flavor violation (CLFV) searches at Fermilab, with emphasis on their sensitivity to physics beyond the Standard Model and their complementarity to the mission-critical LBNF/DUNE neutrino program. In this context, strategic considerations for the evolution of the complex in the Linac-II era will be discussed, including synergies between CLFV initiatives and mission-critical commitments such as reliable high-power beam delivery to LBNF/DUNE.

Hedges, Michael [Fermilab] (ORCID:0000000165041872↗

Diagnostics of the Fermilab Tevatron using an AC dipole

The Fermilab Tevatron is currently the world's highest energy colliding beam facility. Its counter-rotating proton and antiproton beams collide at 2 TeV center-of-mass. Delivery of such intense beam fluxes to experiments has required improved knowledge of the Tevatron's beam optical lattice. An oscillating dipole magnet, referred to as an AC dipole, is one of such a tool to non-destructively assess the optical properties of the synchrotron. We discusses development of an AC dipole system for the Tevatron, a fast-oscillating (f ~ 20 kHz) dipole magnet which can be adiabatically turned on and off to establish sustained coherent oscillations of the beam particles without affecting the transverse emittance. By utilizing an existing magnet and a higher power audio amplifier, the cost of the Tevatron AC dipole system became relatively inexpensive. We discuss corrections which must be applied to the driven oscillation measurements to obtain the proper interpretation of beam optical parameters from AC dipole studies. After successful operations of the Tevatron AC dipole system, AC dipole systems, similar to that in the Tevatron, will be build for the CERN LHC. We present several measurements of linear optical parameters (beta function and phase advance) for the Tevatron, as well as studies of non-linear perturbations from sextupole and octupole elements.

43 PARTICLE ACCELERATORS↗

Measurement of the Oscillation Frequency of B s Mesons in the Hadronic Decay Mode B s → π D s (Φ π)X with the D0 Detector at the Fermilab Tevatron Collider

The standard model (SM) of particle physics is a theory, describing three out of four fundamental forces. In this model the Cabibbo-Kobayashi-Maskawa (CKM) matrix describes the transformation between the mass and weak eigenstates of quarks. The matrix properties can be visualized as triangles in the complex plane. A precise measurement of all triangle parameters can be used to verify the validity of the SM. The least precisely measured parameter of the triangle is related to the CKM element |V td |, accessible through the mixing frequency (oscillation) of neutral B mesons, where mixing is the transition of a neutral meson into its anti-particle and vice versa. It is possible to calculate the CKM element |V td | and a related element |V ts | by measuring the mass differences Δm d (Δm s ) between neutral B d and $\bar{B}$ d (B s and $\bar{B}$ s ) meson mass eigenstates. This measurement is accomplished by tagging the initial and final state of decaying B mesons and determining their lifetime. Currently the Fermilab Tevatron Collider (providing p$\bar{p}$ collisions at {radical}s = 1.96 TeV) is the only place, where B s oscillations can be studied. The first selection of the 'golden', fully hadronic decay mode B s → πD s (Φπ)X at D0 is presented in this thesis. All data, taken between April 2002 and August 2007 with the D0 detector, corresponding to an integrated luminosity of integral Ldt = 2.8 fb -1 is used. The oscillation frequency Δm s and the ratio |V td |/|V ts | are determined as Δm s = (16.6 -0.4 +0.5 (stat) -0.3 +0.4 (sys)) ps -1 , |V td |/|V ts | = 0.213 -0.003 +0.004 (exp) ± 0.008(theor). These results are consistent with the standard model expectations and no evidence for new physics is observable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Executive summary of major NuMI lessons learned: a review of relevant meetings of Fermilab's DUSEL Beamline Working Group

We have gained tremendous experience with the NuMI Project on what was a new level of neutrino beams from a high power proton source. We expect to build on that experience for any new long baseline neutrino beam. In particular, we have learned about some things which have worked well and/or where the experience is fairly directly applicable to the next project (e.g., similar civil construction issues including: tunneling, service buildings, outfitting, and potential claims/legal issues). Some things might be done very differently (e.g., decay pipe, windows, target, beam dump, and precision of power supply control/monitoring). The NuMI experience does lead to identification of critical items for any future such project, and what issues it will be important to address. The DUSEL Beamline Working Group established at Fermilab has been meeting weekly to collect and discuss information from that NuMI experience. This document attempts to assemble much of that information in one place. In this Executive Summary, we group relevant discussion of some of the major issues and lessons learned under seven categories: (1) Differences Between the NuMI Project and Any Next Project; (2) The Process of Starting Up the Project; (3) Decision and Review Processes; (4) ES&H: Environment, Safety, and Health; (5) Local Community Buy-In; (6) Transition from Project Status to Operation; and (7) Some Lessons on Technical Elements. We concentrate here on internal project management issues, including technical areas that require special attention. We cannot ignore, however, two major external management problems that plagued the NuMI project. The first problem was the top-down imposition of an unrealistic combination of scope, cost, and schedule. This situation was partially corrected by a rebaselining. However, the full, desirable scope was never achievable. The second problem was a crippling shortage of resources. Critical early design work could not be done in a timely fashion, leading to schedule delays, inefficiencies, and corrective actions. The Working Group discussions emphasized that early planning and up-front appreciation of the problems ahead are very important for minimizing the cost and for the greatest success of any such project. Perhaps part of the project approval process should re-enforce this need. The cost of all this up-front work is now reflected in the DOE cost of any project we do. If we are being held to an upper limit on the project cost, the only thing available for compromise is the eventual project scope.

43 PARTICLE ACCELERATORS↗

Simultaneous Heavy Flavor Fractions and Top Cross Section Measurement at the Collider Detector at Fermilab

This dissertation describes the measurement of the top pair production cross section, using data from proton–antiproton collisions at a center-of-mass energy of 1.96 TeV, with 2.7 ± 0.2 fb -1 of data collected by the Collider Detector at Fermilab. Background contributions are measured concurrently with the top cross section in the b-tagged lepton-plus-jets sample using a kinematic fit, which simultaneously determines the cross sections and normalizations of t$\bar{t}$, W + jets, QCD, and electroweak processes. This is the first application of a procedure of this kind. The top cross section is measured to be σ t$\bar{t}$ = 7.64±0.57(stat + syst)±0.45(lumi) pb and the Monte Carlo simulation scale factors KW b$\bar{b}$ = 1.57±0.25, K W$\bar{c}$ = 0.94±0.79, KWc = 1.9 ± 0.3, and KW q$\bar{q}$ = 1.1 ± 0.3. These results are consistent with existing measurements using other procedures. More data will reduce the systematic uncertainties and will lead to the most precise of any single analysis to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Observation of a Transverse to Longitudinal Emittance Exchange at the Fermilab A0 Photoinjector

An experimental program to perform a proof of principle of transverse to longitudinal emittance exchange (ϵ x in ↔ ϵ z out and ϵ x in ↔ ϵ z out ) has been developed at the Fermilab A0 Photoinjector. A new beamline, including two magnetic dogleg channels and a TM 110 deflecting mode radio frequency cavity, were constructed for the emittance exchange experiment. The first priority was a measurement of the Emittance Exchange beamline transport matrix. The method of difference orbits was used to measure the transport matrix. Through varying individual beam input vector elements, such as x in , x' in , y in , y' in , z in , or δ in , and measuring the changes in all of the beam output vector's elements, x out , x' out , y out , y' out , z out , δ out , the full 6 x 6 transport matrix was measured. The measured emittance exchange transport matrix was in overall good agreement with our calculated transport matrix. A direct observation of an emittance exchange was performed by measuring the electron beam's characteristics before and after the emittance exchange beamline. Operating with a 14.3 MeV, 250pC electron bunch, ϵ z in of 21.1 ± 1.5 mm • mrad was observed to be exchanged with ϵ x out of 20.8 ± 2.00 mm • mrad. Diagnostic limitations in the ϵ z out measurement did not account for an energy-time correlation, thus potentially returning values larger than the actual longitudinal emittance. The ϵ x in of 4.67 ± 0.22 mm • mrad was observed to be exchanged with ϵ z out of 7.06 ± 0.43 mm • mrad. The apparent ϵ z out growth is consistent with calculated values in which the correlation term is neglected.

43 PARTICLE ACCELERATORS↗