Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Diffusion-Limited Kinetics of Isovalent Cation Exchange in III–V Nanocrystals Dispersed in Molten Salt Reaction Media

The goal of this work is to determine the kinetic factors that govern isovalent cation exchange in III–V colloidal quantum dots using molten salts as the solvent and cation source. We focus on the reactions of InP + GaI 3 → In 1 – x Ga x P and InAs + GaI 3 → In 1–x Ga x As to create technologically important ternary III–V phases. We find that the molten salt reaction medium causes the transformation of nearly spherical InP nanocrystals to tetrahedron-shaped In 1–x Ga x P nanocrystals. Furthermore, we determine that the activation energy for the cation exchange reaction is 0.9 eV for incorporation of Ga into InP and 1.2 eV for incorporation of Ga into InAs, both much lower than the measured values in bulk semiconductors. Next, we use powder XRD simulations to constrain our understanding of the structure of the In 1–x Ga x P nanocrystals. Together our results reveal several important features of molten salt-mediated cation exchange and provide guidance for future development of these materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rational Materials and Structure Design for Improving the Performance and Durability of High Temperature Proton Exchange Membranes (HT-PEMs)

Hydrogen energy as the next-generation clean energy carrier has attracted the attention of both academic and industrial fields. A key limit in the current stage is the operation temperature of hydrogen fuel cells, which lies in the slow development of high-temperature and high-efficiency proton exchange membranes. Currently, much research effort has been devoted to this field, and very innovative material systems have been developed. The authors think it is the right time to make a short summary of the high-temperature proton exchange membranes (HT-PEMs), the fundamentals, and developments, which can help the researchers to clearly and efficiently gain the key information. In this paper, the development of key materials and optimization strategies, the degradation mechanism and possible solutions, and the most common morphology characterization techniques as well as correlations between morphology and overall properties have been systematically summarized.

08 HYDROGEN↗

Flue-Gas Desulfurization Effluent Management using an Innovative Low-Energy Biosorpotion Treatment System to Remove Key Contaminants

Among the most critical water contaminants of concern affecting wide geographical regions and a number of industries and natural systems is selenium. Selenium found in surface, ground and wastewater in originates from natural sources, as well as industrial sources such as petroleum refineries, electronics manufacturing, pesticides, and coal power plants and mining also contribute to selenium contamination in water in the US. At high concentrations, selenium is toxic to human and wildlife. There are a number of technologies that have been used to treat selenium and other similar contaminants in water. Biological treatment of selenium has been used in the past to reduce soluble SeVI and/or SeIV to insoluble Se0, which is then filtered in the same vessel. The insoluble selenium (Se0) is then backwashed from the system and solids are separated for subsequent disposal, if they meet the leaching and water content criteria. In order to promote biological reduction to insoluble Se0, heating of bioreactor is needed in some applications, and excess food source (electron donor) is added so that all selenium can be filtered. An additional disadvantage of these systems is the significant amount of water lost due to extensive and frequent backwash and rinse cycles. When comparing the advantages and energy requirements of the various treatment technologies, RO membrane filtration immediately stands out due to the excessive energy expenditure needed to pump water across the membrane although RO is an effective way to remove selenium. In addition, RO requires extensive pretreatment, such as MF membrane, and frequent maintenance, rendering it an expensive option that may be out of reach for certain applications. In fact, although the performance was good during the pilot testing by the NSMP Working Group for treatment naturally occurring selenium in the surface water, the high electricity requirements and significant reject water stream made it an infeasible alternative. While conventional ion exchange maybe an effective treatment option, it requires frequent regeneration of the resin when applied to highly contaminated water, which leads to several tons of contaminant-laden, high-salinity brine that needs to be disposed off-site each day. One of the water systems in the west coast currently uses ion exchange for selenium treatment and has been trucking selenium laden hazardous brine waste weekly in the last several years. Pneumatic pumping and rinse water pumping required for ion exchange also increase the energy usage. In comparison, adsorption process is a passive treatment system where contaminated water comes in contact with an adsorption media in a vessel. Typically, there is no mixing, backwash, or recycle pumping required, thus significantly reducing the energy usage. A passive single-use adsorption system does not require backwash, thereby generating small amount of process waste, and producing the highest water yield among the alternatives. The energy and water efficiencies, and applicability for SeVI and SeIV are summarized in Table 1. Despite these benefits though, adsorption typically does not work for the most oxidized form of selenium (SeVI). The innovative biosorption process integrates both process to increase the treatment efficiency while minimizing energy, chemical, and time required to treat both SeVI and SeIV. Additional advantages include simple partial biological reduction with reduced on-site waste generation, which lead to water and electricity savings, and less operational need compared to biological treatment alone. This makes biosorption especially suitable for remote areas, where liquid backwash and brine disposal may be cost prohibitive or infeasible.

20 FOSSIL-FUELED POWER PLANTS↗

Numerical Study and Validation of Melting and Solidification in PCM Embedded Heat Exchangers with Straight Tube

Latent heat thermal energy storage (LHTES) systems have shown great potential to enable reliable use of renewable energy and load shifting. LHTES offer high storage density and release energy at near constant temperature because of its use of phase change materials (PCMs). The cylindrical PCM heat exchangers (PCMHX) are one of the most used technologies due to their simplicity. Numerical models for such PCMHX enable engineers to estimate their performance for different design parameters and operating conditions without having to test them all. However, modeling the phase change phenomena can be challenging. To better understand the difficulties involving accurate modeling of PCMHX, a cylindrical latent storage unit filled with PCM and water as in-tube heat transfer fluid (HTF) is numerically investigated. This paper presents a study based on a 2D-axisymmetric model of a straight tube embedded in PCM in a cylindrical container. CFD is used to study the charging (melting) and discharging (solidification) phenomena. The models are validated against experimental and numerical data from the literature. The predicted local PCM temperature profile over time agrees within 2K compared to the experimental values. The paper also presents a simple method to estimate the melting and solidification phase change temperature range from limited data provided by PCM manufacturers.

PCM, melting, solidification, CFD, heat exchanger↗

ORGANIC RANKINE CYCLE TURBINE AND HEAT EXCHANGER SIZING FOR LIQUID AIR COMBINED CYCLE

Cryogenic energy storage offers several opportunities to design turbomachinery and other equipment for novel cycles. This paper presents the design and analysis of turbomachinery and heat exchangers for an Organic Rankine Cycle (ORC) subsystem for a hybrid energy storage concept. The Liquid Air Combined Cycle is an energy storage system that stores air at cryogenic conditions at times with high variable renewable energy to be dispatched along with a gas turbine to recover the exhaust heat. In order to re-vaporize the air, the liquid air is coupled with an ORC as an additional bottoming cycle. The ORC turbine is expected to expand the fluid with a pressure ratio of nearly 30 and a flow rate of approximately 45 kg/s. Sizing calculations for both a radial and axial turbine solution were performed over a range of speeds and stages to determine the optimal design point. The results show that either an axial (8- or 9-stage) or radial (four stages at two shaft speeds) turbine are capable of handling the pressure ratios. Further trades of the two configurations would be required to determine the best option. The ORC system also incorporates five heat exchangers to distribute heat, vaporize the liquid air, or recover exhaust heat from the gas turbine. Three heat exchangers were analyzed to understand the size of heat exchangers and pressure drop for the overall system. Different types of heat exchangers were explored for the different purposes, including plate-fin heat exchangers, gasketed plate heat exchangers and shell-in-tube heat exchangers. It was determined that the ORC recuperator, liquid-air vaporizer, and vaporized air pre-heater would be counter-flow heat exchangers using a gasketed plate design. Keywords: Energy Storage, Liquid Air Energy Storage, Organic Rankine Cycle

Pryor, Owen↗

Fission-fragment excitation energy sharing beyond scission

A simplified, though realistic, model describing two receding and accelerating fission fragments, due to their mutual Coulomb repulsion, shows that fission fragments share excitation energy well after they ceased to exchange nucleons. Here, this mechanism leads to a lower total kinetic energy of the fission fragments, particularly if the pygmy resonances in the fission fragments are excited. Even though the emphasis here is on fission, similar arguments apply to fragments in heavy-ion reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Phenyl‐Free Polynorbornenes for Potential Anion Exchange Ionomers for Fuel Cells and Electrolyzers

Abstract Ionomers in the catalyst layer play a critical role in the performance of fuel cells and electrolyzers. Phenyl adsorption on hydrogen oxidation catalysts and electrochemical oxidation of phenyl moieties on oxygen evolution catalysts are detrimental to the alkaline devices’ performance. Here the adsorption energy of phenyl‐containing ionomers is compared to provide the rationale for implementing phenyl‐free ionomers. Density functional theory calculations indicated that the norbornane fragment has minimal adsorption energy on Pt(111) due to the absence of aromatic π electrons. A soluble quaternized polynorbornene ionomer is prepared by vinyl addition polymerization, and it exhibits high performance in both fuel cells and electrolyzers, proving the advantage of the phenyl‐free structure. This study establishes the phenyl adsorption energy‐electrode performance relationship, highlighting the importance of material interactions between the catalysts and ionomers.

25 ENERGY STORAGE↗

Advancing Diffusion Bonded Compact Heat Exchangers for High Temperature Applications

Enhancement of the diffusion bonding process for the development of compact heat exchangers (CHXs) provides an energy efficient solution for high-temperature applications in advanced nuclear reactors and other technologies. However, available information is limited concerning the diffusion bonding (and manufacturing) of CHXs in high temperature applications and associated selection of bonded materials, bonding conditions, mechanical performance, and thermo-fluid characteristics. Here this article reviews the available knowledge and the ongoing research being conducted to address gaps in information and application.

36 MATERIALS SCIENCE↗

Mantaray: A Rust Package for Ray Tracing Ocean Surface Gravity Waves

Ocean surface gravity waves are an important component of air-sea interaction, influencing energy, momentum, and gas exchanges across the ocean-atmosphere interface. In specific applications such as refraction by ocean currents or bathymetry, ray tracing provides a computationally efficient way to gain insight into wave propagation. In this paper, we introduce Mantaray, an open-source software package implemented in Rust, with a Python interface, that solves the ray equations for ocean surface gravity waves. Mantaray is designed for performance, robustness, and ease of use. The package is modular to facilitate further development and can currently be applied to both idealized and realistic wave propagation problems (Fig. 1).

16 TIDAL AND WAVE POWER↗

Kinetic Control of Angstrom-Scale Porosity in 2D Lattices for Direct Scalable Synthesis of Atomically Thin Proton Exchange Membranes

Angstrom-scale pores introduced into atomically thin 2D materials offer transformative advances for proton exchange membranes in several energy applications. Here, we show that facile kinetic control of scalable chemical vapor deposition (CVD) can allow for direct formation of angstrom-scale proton-selective pores in monolayer graphene with significant hindrance to even small, hydrated ions (K + diameter ~6.6 Å) and gas molecules (H 2 kinetic diameter ~2.9 Å). We demonstrate centimeter-scale Nafion|Graphene|Nafion membranes with proton conductance ~3.3–3.8 S cm –2 (graphene ~12.7–24.6 S cm –2 ) and H + /K + selectivity ~6.2–44.2 with liquid electrolytes. The same membranes show proton conductance ~4.6–4.8 S cm –2 (graphene ~39.9–57.5 S cm –2 ) and extremely low H 2 crossover ~1.7 × 10 –1 – 2.2 × 10 –1 mA cm –2 (~0.4 V, ~25 °C) with H 2 gas feed. We rationalize our findings via a resistance-based transport model and introduce a stacking approach that leverages combinatorial effects of interdefect distance and interlayer transport to allow for Nafion|Graphene|Graphene|Nafion membranes with H + /K + selectivity ~86.1 (at 1 M) and record low H 2 crossover current density ~2.5 × 10 –2 mA cm –2 , up to ~90% lower than state-of-the-art ionomer Nafion membranes ~2.7 × 10 –1 mA cm –2 under identical conditions, while still maintaining proton conductance ~4.2 S cm –2 (graphene stack ~20.8 S cm –2 ) comparable to that for Nafion of ~5.2 S cm –2 . Furthermore, our experimental insights enable functional atomically thin high flux proton exchange membranes with minimal crossover.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

Demonstration of a multi-channel fluidized bed particle–supercritical carbon dioxide heat exchanger for concentrating solar applications

High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.

14 SOLAR ENERGY↗

Experimental investigation on heat transfer performance of drain water heat recovery heat exchangers

Water heating accounts for 18 % of residential energy consumption, and a substantial portion of this energy can be recovered through drain water heat recovery systems. Here, this paper investigates the heat transfer performance of drain water heat recovery heat exchangers. Two heat exchanger configurations were studied: vertical (gravity film exchanger) and horizontal. The heat recovery performance of the exchangers was quantified using sensible effectiveness and characteristic curves following the ε-NTU approach. Depending on the flow conditions, heat exchangers with a vertical configuration offered higher heat transfer effectiveness compared with the horizontal configuration under similar operating conditions. Furthermore, the results showed that properly designed and sized heat exchangers can effectively recover considerable amounts of waste heat from drains, depending on flow rates. Additionally, in the vertical heat exchanger configuration, low flow rates result in partially wet conditions, resulting in lower heat transfer effectiveness. Therefore, two distributor configurations are proposed to improve the heat transfer performance of vertically configured heat exchangers at low flow rates. The proposed distributor configurations and data presented in this paper will be useful in the design and development of drain water heat recovery systems in building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Veneziano variations: how unique are string amplitudes?

String theory offers an elegant and concrete realization of how to consistently couple states of arbitrarily high spin. But how unique is this construction? In this paper we derive a novel, multi-parameter family of four-point scattering amplitudes exhibiting i) polynomially bounded high-energy behavior and ii) exchange of an infinite tower of high-spin modes, albeit with a finite number of states at each resonance. These amplitudes take an infinite-product form and, depending on parameters, exhibit mass spectra that are either unbounded or bounded, thus corresponding to generalizations of the Veneziano and Coon amplitudes, respectively. For the bounded case, masses converge to an accumulation point, a peculiar feature seen in the Coon amplitude but more recently understood to arise naturally in string theory [1]. Importantly, our amplitudes contain free parameters allowing for the customization of the slope and offset of the spin-dependence in the Regge trajectory. We compute all partial waves for this multi-parameter class of amplitudes and identify unitary regions of parameter space. For the unbounded case, we apply similar methods to derive new deformations of the Veneziano and Virasoro-Shapiro amplitudes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A comparative look at structural variation among RC–LH1 ‘Core’ complexes present in anoxygenic phototrophic bacteria

All purple photosynthetic bacteria contain RC–LH1 ‘Core’ complexes. The structure of this complex from Rhodobacter sphaeroides, Rhodopseudomonas palustris and Thermochromatium tepidum has been solved using X-ray crystallography. Recently, the application of single particle cryo-EM has revolutionised structural biology and the structure of the RC–LH1 ‘Core’ complex from Blastochloris viridis has been solved using this technique, as well as the complex from the non-purple Chloroflexi species, Roseiflexus castenholzii. It is apparent that these structures are variations on a theme, although with a greater degree of structural diversity within them than previously thought. Furthermore, it has recently been discovered that the only phototrophic representative from the phylum Gemmatimonadetes, Gemmatimonas phototrophica, also contains a RC–LH1 ‘Core’ complex. At present only a low-resolution EM-projection map exists but this shows that the Gemmatimonas phototrophica complex contains a double LH1 ring. This short review compares these different structures and looks at the functional significance of these variations from two main standpoints: energy transfer and quinone exchange.

59 BASIC BIOLOGICAL SCIENCES↗

A review of experimental methods to determine bioaerosol transfer in energy recovery ventilators

Increasing ventilation is an effective method to reduce indoor airborne disease transmission. An Energy recovery ventilator (ERV) is a passive energy recovery device used to reduce the energy consumption of heating, ventilation and air-conditioning (HVAC) systems for conditioning the ventilation air. It preconditions the ventilation air by transferring energy from building exhaust air. Therefore, the ventilation and exhaust air streams interact directly/indirectly in the ERV for energy transfer. It is surmised that the ERV may transfer bioaerosols (with pathogens) from the exhaust air to ventilation air, resulting in the spread of infectious diseases. Consequently, many pandemic HVAC guidelines recommend that the use of ERVs be limited. This is a highly unsustainable direction given the increased energy requirements associated with the high ventilation provision advocated for pandemic operation. It must be noted that no validated experimental evidence exists in literature for bioaerosol transfer in ERVs. Hence, it is necessary to conduct extensive bioaerosol transfer research before adopting the unsustainable practice of limiting the utilization of ERVs. The main objective of this review study is to summarize the experimental methods and instrumentation for bioaerosol transfer research in ERVs. This comprehensive article provides a detailed overview of the generation, sampling, and analysis of bioaerosols for conducting the experiments. Further, it explains the possible mechanisms for bioaerosol transfer in various types of ERVs based on which the ERVs that need immediate attention are identified. The main contribution of this research paper is that it provides a novel experimental method which encompasses the biosafety aspects, instrumentation, performance parameters and uncertainties in conducting virus contained bioaerosol transfer study in ERVs. The findings from this review will be helpful in designing bioaerosol transfer experiments and developing future ERV test standards for such experiments.

42 ENGINEERING↗

Enabling aqueous processing for LiNi 0.80 Co 0.15 Al 0.05 O 2 (NCA)-based lithium-ion battery cathodes using polyacrylic acid

Replacing N-methyl-2-pyrrolidone (NMP) with water in the production of lithium-ion battery cathodes is critical to realizing process cost savings and improved worker safety. LiNi 0.80 Co 0.15 Al 0.05 O 2 (NCA) is a poor fit for aqueous processing due to destructive Al current collector corrosion resulting from highly basic slurries and detrimental surface reconstruction reactions that occur in water. In this study, polyacrylic acid (PAA, MW = 450,000 g·mol -1 ) is examined as a corrosion-mitigating and surface-stabilizing agent. Adding PAA to an aqueous NCA slurry can provide a stable pH (4.0–8.5) for at least 4 h, since the carboxyl groups from PAA dissociate and increase the proton concentration in the slurry. Further, these groups can also adsorb to the surface of NCA particles and provide electrostatic stability from active material particle agglomeration, as revealed by zeta potential measurements. Minor cracking does occur at the electrode surface; this cracking likely caused poorer adhesion to the Al current collector in the aqueous-processed film when compared to the NMP-processed baseline. Electrochemically, the leached Li does cause a lower initial capacity for the aqueous-processed cathode, though the capacity retention of the aqueous-processed cathode is better than the baseline. The cracks in the coating led to a rise in charge transfer resistance that hindered rate capability above 1C.

25 ENERGY STORAGE↗