Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

How to overcome inter-electrode variability and instability to quantify dissolved oxygen, Fe(II), mn(II), and S(-II) in undisturbed soils and sediments using voltammetry

Background: Although uniquely capable of measuring multiple redox constituents nearly simultaneously with no or minimal sample pretreatment, voltammetry is currently underutilized in characterizing redox conditions in aquatic and terrestrial systems. Investigation of undisturbed media such as pore water requires a solid-state electrode, and such electrodes can be difficult to fabricate reproducibly. An approach to determine the concentrations of electroactive constituents using indirectly calibrated electrodes has been developed, but the protocol for and accuracy of this approach—the pilot ion method—has not been documented in detail. Results: A detailed procedure for testing electrode quality is provided, and the application and limitations of the pilot ion method have been documented. To quantify Fe(II) and Mn(II), subtraction of non-linear baseline functions from voltammetric signals produced better calibration curves than did linear baselines, enabled lower detection limits and reliable deconvolution of overlapping signals, and was successfully applied to sediment pore water signals. We observed that electrode sensitivities often vary by tens of percent, and that the sensitivity declines over time. The ratio of calibration slopes of Mn(II) to Fe(II) varied by no more than 11% from one Hg/Au electrode to another and Fe(II) concentrations predicted by the Mn(II) pilot ion were, on average, 13% different from their actual values. However, concentration predictions by the pilot ion method were worse for less than 15 μM Fe(II) (46% different on average). The ratio of calibration slopes of Mn(II) to S(-II) varied by almost 20% from one Hg/Au electrode to another, and S(-II) predicted concentrations were as much as 58% different from their actual values. These predictions of Fe(II) and S(-II) concentrations indicate that the accuracy of the pilot ion method depends on how independent calibration slope ratios are from the electrode used. At medium-to-high concentration for the ocean, naturally derived dissolved organic carbon did not significantly affect the baseline-corrected electrode response of Mn(II) and Fe(II), but did significantly affect the response of S(-II). Conclusions: Despite their intrinsic variability, Hg/Au electrodes fabricated by hand can be used to quantify O2, S (-II), Fe(II), and Mn(II) without calibrating every electrode for every constituent of interest. The pilot ion method can achieve accuracies to within 20% or less, provided that the underlying principle—the independence of slope ratios—is demonstrated for all voltammetric techniques used, and effects of the physicochemical properties of the system on voltammetric signals are addressed through baseline subtraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impedance studies of Ni/Cd and Ni/H cells using the cell case as reference electrode

Many impedance studies were carried out on Ni electrodes and Ni/Cd and Ni/H batteries. In order for impedance to become a diagnostic tool, accurate and reproducible measurements must be made, and some way of separating the contributions of the individual electrodes must be found. Using the PAR and the Solartron impedance equipment, studies have found that consistent measurements can be made if the cells or electrodes are equilibrated at the voltage of interest. In the charged state, equilibration times required are short, on the order of a few hours or less, but the equilibration time required becomes progessively longer as the voltage is lowered. The cell case can be used as a reference electrode during impedance measurements. The voltage of the case with respect to the electrodes is unimportant provided that it does not change appreciably during the course of the measurement. Measurements were made with several uncycled Ni/Cd cells, one from a lot which was known to have faulty Cd electrodes and another from a lot which showed excellent cycle life and presumably had good Cd electrodes. The impedances of the Ni electrodes vs. the case were similar, while the impedance of the poor Cd electrodes vs. the case. A 50 AH Ni/H cell was also investigated. After subtraction of the ohmic resistances, the sums of the impedances of the individual electrodes were very close to the impedance of the total cell. This indicates that the method is valid for examining the characteristics of the individual electrodes in situ.

Reid, Margaret A.↗

Evaluation of Niobium as Candidate Electrode Material for DC High Voltage Photoelectron Guns

The field emission characteristics of niobium electrodes were compared to those of stainless steel electrodes using a DC high voltage field emission test apparatus. A total of eight electrodes were evaluated: two 304 stainless steel electrodes polished to mirror-like finish with diamond grit and six niobium electrodes (two single-crystal, two large-grain, and two fine-grain) that were chemically polished using a buffered-chemical acid solution. Upon the first application of high voltage, the best large-grain and single-crystal niobium electrodes performed better than the best stainless steel electrodes, exhibiting less field emission at comparable voltage and field strength. In all cases, field emission from electrodes (stainless steel and/or niobium) could be significantly reduced and sometimes completely eliminated, by introducing krypton gas into the vacuum chamber while the electrode was biased at high voltage. Of all the electrodes tested, a large-grain niobium electrode performed the best, exhibiting no measurable field emission (< 10 pA) at 225 kV with 20 mm cathode/anode gap, corresponding to a field strength of 18:7 MV/m.

BastaniNejad, M.↗

Z-pinch plasma confinement system having intermediate electrode and methods for use

An example method includes directing gas, via one or more first valves, from within an inner electrode to an acceleration region between the inner electrode and an outer electrode that substantially surrounds the inner electrode, directing gas, via two or more second valves, from outside the outer electrode to the acceleration region, and applying, via a power supply, a voltage between the inner electrode and the outer electrode, thereby converting at least a portion of the directed gas into a plasma saving a substantially annular cross section, the plasma flowing axially within the acceleration region toward a first end of the inner electrode and a first end of the outer electrode and, thereafter, establishing a Z-pinch plasma that flows between the first end of the outer electrode and the first end of the inner electrode. Related plasma confinement systems and methods are also disclosed herein.

Shumlak, Uri↗

Promoting electrochemical rates by concurrent ionic-electronic conductivity enhancement in high mass loading cathode electrode

Enhancing the fast charging capacity of thick electrodes with high mass loading is imperative in expediting the widespread adoption of electric vehicles. Nonetheless, the insufficient charge transfer kinetics of thick electrodes hinder the movement of effective electrons and ions, hence diminishing capacity at high current rates. In this work, we applied sustainable and biodegradable cellulose nanocrystals (CNCs) as electrode additives. It is the first time to simultaneously improve the electronic conductivity by optimizing the carbon dispersion and establishing electron transfer networks, as well as boosting the ionic conductivity of electrodes by shortening the ion transfer pathway. Specifically, the LiNi 0.6 Mn 0.2 Co 0.2 O 2 electrodes incorporating 1% dual functional CNCs additive exhibit improved effective electrical conductivity from 0.11 to 0.16 S/m and risen effective ionic conductivity from 0.36 to 0.62 S/m, in comparison to counterpart electrodes without CNCs. Therefore, the 1% CNC electrode with a high mass loading of 27.0 mg/cm 2 delivers a discharge capacity of 128 mAh/g at 1 C, which is superior to that of the CNC-free electrodes (95 mAh/g). In short, this study presents a novel environmentally friendly, economically viable, and dual-functional electrode additive that enhances both electronic and ionic conductivities with the aim of facilitating the widespread adoption of fast-charging high mass loading electrodes.

25 ENERGY STORAGE↗

Effects of polymeric binders on the cracking behavior of silicon composite electrodes during electrochemical cycling

Mechanical degradation caused by lithiation/delithiation-induced stress and large volume change is the primary cause of fast capacity fading of silicon (Si)-based electrodes. Although intensive efforts have been devoted to understanding electromechanically induced fractures of electrodes made of Si alone (e.g., Si particles, Si thin films, and Si wafers), the cracking behavior of Si/polymeric binders/carbon black composite electrodes is unclear and poorly understood. Here, we investigate, by in situ and ex situ techniques, the cracking behavior of Si composite electrodes made with different binders, including polyvinylidene fluoride (PVDF), sodium-alginate (SA), sodium-carboxymethyl cellulose (Na-CMC), and Nafion. We found that extensive cracks form during the 1st delithiation process, which periodically open and close during subsequent lithiation/delithiation cycles at the same locations in the Si composite electrodes made with SA, Na-CMC, and Nafion. In contrast, a significantly fewer number of cracks form in the Si/PVDF electrodes after electrochemical cycling. A possible mechanism is proposed to help understand the effects of binders on the cracking behavior (e.g., crack spacing and island size) of Si composite electrodes. We also suggest possible approaches, including reducing the electrode thickness, patterning electrodes, and using highly recoverable binders, to inhibit cracks and improve the mechanical integrity of Si composite electrodes.

25 ENERGY STORAGE↗

Computational design of microarchitected porous electrodes for redox flow batteries

Porous electrodes are used as the core reactive component across electrochemical technologies. In flowing systems, controlling the fluid distribution, species transport, and reactive environment is critical to attaining high performance. However, conventional electrode materials like felts and papers provide few opportunities for precise engineering of the electrode and its microstructure. To address these limitations, architected electrodes composed of unit cells with spatially varying geometry determined via computational optimization are proposed. Resolved simulation is employed to develop a homogenized description of the constituent unit cells. These effective properties serve as inputs to a continuum model for the electrode when used in the negative half-cell of a vanadium redox flow battery. Porosity distributions minimizing power loss are then determined via computational design optimization to generate architected porosity electrodes. The architected electrodes are compared to bulk, uniform porosity electrodes and found to lead to increased power efficiency across operating flow rates and currents. The design methodology is further used to generate a scaled-up electrode with comparable power efficiency to the bench-scale systems. Finally, the variable porosity architecture and computational design methodology presented here thus offers a novel pathway for automatically generating spatially engineered electrode structures with improved power performance.

25 ENERGY STORAGE↗

Synthesis, characterization and electrochemmistry of lithium battery electrodes : xLi{sub 2}MnO{sub 3}{center_dot}(1-x)LiMn{sub 0.333}Ni{sub 0.333}Co{sub 0.333}O{sub2} (0{le}x{le}0.7).

Lithium- and manganese-rich layered electrode materials, represented by the general formula xLi{sub 2}MnO{sub 3} {center_dot} (1-x)LiMO{sub 2} in which M is Mn, Ni, and Co, are of interest for both high-power and high-capacity lithium ion cells. In this paper, the synthesis, structural and electrochemical characterization of xLi{sub 2}MnO{sub 3} {center_dot} (1-x)LiMn{sub 0.333}Ni{sub 0.333}Co{sub 0.333}O{sub 2} electrodes over a wide compositional range (0 {le} x {le} 0.7) is explored. Changes that occur to the compositional, structural, and electrochemical properties of the electrodes as a function of x and the importance of using a relatively high manganese content and a high charging potential (>4.4 V) to generate high capacity (>200 mAh/g) electrodes are highlighted. Particular attention is given to the electrode composition 0.3Li{sub 2}MnO{sub 3} {center_dot} 0.7LiMn{sub 0.333}Ni{sub 0.333}Co{sub 0.333}O{sub 2} (x = 0.3) which, if completely delithiated during charge, yields Mn{sub 0.533}Ni{sub 0.233}Co{sub 0.233}O{sub 2}, in which the manganese ions are tetravalent and, when fully discharged, LiMn{sub 0.533}Ni{sub 0.233}Co{sub 0.233}O{sub 2}, in which the average manganese oxidation state (3.44) is marginally below that expected for a potentially damaging Jahn-Teller distortion (3.5). Acid treatment of 0.3Li{sub 2}MnO{sub 3} {center_dot} 0.7LiMn{sub 0.333}Ni{sub 0.333}Co{sub 0.333}O{sub 2} composite electrode structures with 0.1 M HNO{sub 3} chemically activates the Li{sub 2}MnO{sub 3} component and essentially eliminates the first cycle capacity loss but damages electrochemical behavior, consistent with earlier reports for Li{sub 2}MnO{sub 3}-stabilized electrodes. Differences between electrochemical and chemical activation of the Li{sub 2}MnO{sub 3} component are discussed. Electrochemical charge/discharge profiles and cyclic voltammogram data suggest that small spinel-like regions, generated in cycled manganese-rich electrodes, serve to stabilize the electrodes, particularly at low lithium loadings (high potentials). The study emphasizes that, for high values of x, a relatively small LiMO{sub 2} concentration stabilizes a layered Li{sub 2}MnO{sub 3} electrode to reversible lithium insertion and extraction when charged to a high potential.

74 ATOMIC AND MOLECULAR PHYSICS↗

Diagnostics for the biased electrode experiment on NSTX

A linear array of four small biased electrodes was installed in NSTX in an attempt to control the width of the scrape-off layer by creating a strong local poloidal electric field. The set of electrodes was separated poloidally by a 1 cm gap between electrodes and were located slightly below the midplane of NSTX, 1 cm behind the rf antenna, and oriented so that each electrode is facing approximately normal to the magnetic field. Each electrode can be independently biased to {+-}100 V. Present power supplies limit the current on two electrodes to 30 A and the other two to 10 A each. The effect of local biasing was measured with a set of Langmuir probes placed between the electrodes and another set extending radially outward from the electrodes, and also by the gas puff imaging diagnostic located 1 m away along the magnetic field lines intersecting the electrodes. Two fast cameras were also aimed directly at the electrode array. The hardware and controls of the biasing experiment will be presented and the initial effects on local plasma parameters will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of electrode spacing on the density distributions of electrons, ions, and metastable and radical molecules in SiH{sub 4}/NH{sub 3}/N{sub 2}/He capacitively coupled plasmas

Semiconductor fabrication often requires the deposition of hydrogenated silicon nitride (SiN{sub x}H{sub y}) film using SiH{sub 4}/NH{sub 3}/N{sub 2}/He capacitively coupled plasma (CCP) discharge. As analysis of the discharge geometry is essential to understanding CCP deposition, the effect of electrode spacing on the two-dimensional distributions of electrons, ions, and metastable and radical molecules was analyzed numerically using a fluid model. The simulation shows that the spatial variations in the ionization rates near the sheath become more obvious as the electrode spacing increases. In addition, as molecule-molecule gas-phase reactions are significantly affected by the local residence time, large electrode spacings are associated with significant volumetric losses for positive ions. Consequently, an increase of the electrode spacing leads axial density profiles of ions to change from bell shaped to double humped. However, NH{sub 4}{sup +} persistently maintains a bell-shaped axial density profile regardless of the degree of electrode spacing. We set the mole fraction of NH{sub 3} to only 1% of the total flow at the inlet, but NH{sub 4}{sup +} is the most abundant positive ion at the large electrode spacings. As the gas flow can transport the radicals around the space between the electrodes, we found that radical density distribution shifts toward the grounded electrode. The shift becomes pronounced as the electrode spacing increases. Finally, to validate our model, we compared the calculated deposition rate profile with the experimental data obtained along the wafer radius. According to our numerical results, the SiN{sub x}H{sub y} deposition rate decreases by approximately 16% when the electrode spacing increases from 9 to 20 mm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improvement of the electrochromic response of a low-temperature sintered dye-modified porous electrode using low-resistivity indium tin oxide nanoparticles

An indium tin oxide (ITO) nanoparticle-based porous electrode sintered at low temperatures was investigated as a transparent electrode for electrochromic displays (ECDs). The electrochromic (EC) response of the dye-modified ITO porous electrode sintered at 150 °C, which exhibited a generally low resistivity, was markedly superior to that of a conventional dye-modified TiO{sub 2} porous electrode sintered at the same temperature. Moreover, the EC characteristics of the dye-modified ITO porous electrode sintered at 150 °C were better than those of the high-temperature (450 °C) sintered conventional dye-modified TiO{sub 2} porous electrode. These improvements in the EC characteristics of the dye-modified ITO porous electrode are attributed to its lower resistivity than that of the TiO{sub 2} porous electrodes. In addition to its sufficiently low resistivity attained under the sintering conditions required for flexible ECD applications, the ITO porous film had superior visible-light transparency and dye adsorption capabilities. We conclude that the process temperature, resistivity, optical transmittance, and dye adsorption capability of the ITO porous electrode make it a promising transparent porous electrode for flexible ECD applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ion flow and sheath structure near positively biased electrodes

What effect does a dielectric material surrounding a small positively biased electrode have on the ion flow and sheath structure near the electrode? Measurements of the ion velocity distribution function and plasma potential near positively biased electrodes were made using laser-induced fluorescence and an emissive probe. The results were compared with 2D particle-in-cell simulations. Both measurements and simulations showed that when the positive electrode was surrounded by the dielectric material, ions were accelerated toward the electrode to approximately 0.5 times the ion sound speed before being deflected radially by the electron sheath potential barrier of the electrode. The axial potential profile in this case contained a virtual cathode. In comparison, when the dielectric material was removed from around the electrode, both the ion flow and virtual cathode depth near the electrode were dramatically reduced. Furthermore, these measurements suggest that the ion presheath from the dielectric material surrounding the electrode may enclose the electron sheath of the electrode, resulting in a virtual cathode that substantially influences the ion flow profile in the region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring Electrode-Level State-of-Charge and State-of-Health Dynamics in Lithium-Ion Battery Cells: Modeling and Experimental Identification

A computationally efficient model serves as a critical prerequisite for battery performance analysis and advanced battery management algorithm design. Although battery models that capture cell-level behavior have been widely explored in existing literature, electrode-level battery models have received much lesser attention till to date. However, such electrode-level models can significantly increase battery performance and life by enabling electrode-level health-conscious control. Such electrode-level control can effectively expand usable energy and power limits of the battery cells by utilizing the knowledge of individual electrodes' charge and health. In this context, this paper presents a comprehensive battery model developed with a reference electrode insertion that captures (i) electrode-level charge/discharge dynamics, (ii) stoichiometric and temporal dependencies of electrode-level resistances, (iii) solid electrolyte interface (SEI) layer growth as key degradation phenomenon, and (iv) capacity fade and resistance rise in each electrode due to nominal battery aging. The proposed model is identified, and a preliminary validation is performed utilizing terminal voltage and negative electrode potential data collected from a pouch cell under one continuous cycling and accelerated aging conditions where the cell experienced 14% capacity loss.

aging↗

Characteristics of Oxygen Electrode Supported Reversible Solid Oxide Cells

Oxygen-electrode-supported solid oxide cells (OESCs) have potential advantages over fuel-electrode-supported cells, including reduced fuel-electrode concentration polarization, better oxygen electrode current collection, and flexibility in the fuel electrode choice. However, there are serious drawbacks including the difficulty of co- firing the oxygen electrode and electrolyte, and oxygen electrode concentration polarization. This paper explores the characteristics of OESCs with La 0.8 Sr 0.2 MnO 3-δ -Zr 0.92 Y 0.16 O 2-δ (LSM-YSZ) electrode-support enhanced by SrTi 0.3 Fe 0.6 Co 0.1 O 3-δ (STFC) infiltration, thin YSZ electrolyte, and SrTi 0.3 Fe 0.7 O 3-δ (STF) fuel electrodes. Here, the STFC infiltration increases fuel cell maximum power density by > 1.5 times and electrolysis current density (at 1.3 V) by > 2 times. Cell performance in pure oxygen is compared to that in air, exploring a possible reversible solid oxide cell system configuration where oxygen produced during electrolysis is stored and subsequently used during fuel cell operation. The fuel cell maximum power density is increased from 0.88 W cm -2 in air to 1.37 W cm -2 in oxygen, with limiting current increased from 1.7 to >5.6 A cm -2 ; the electrolysis performance is essentially unchanged, probably because the electrode air becomes enriched with oxygen during electrolysis.

25 ENERGY STORAGE↗

Advanced Drying Process for Lower Manufacturing Cost of Electrodes

For this Vehicle Technologies Incubator/Energy Storage R&D topic, Lambda Technologies teamed with Navitas Systems and proposed a new advanced drying process that promised a 5X reduction in electrode drying time and significant reduction in the cost of large format lithium batteries used in PEV's. The operating principle of the proposed process was to use penetrating radiant energy source Variable Frequency Microwaves (VFM), that are selectively absorbed by the polar water or solvent molecules instantly in the entire volume of the electrode. The solvent molecules are thus driven out of the electrode thickness making the process more efficient and much faster than convective drying method. To evaluate the Advanced Drying Process (ADP) a hybrid prototype system utilizing VFM and hot air flow was designed and fabricated. While VFM drives the solvent out of the electrode thickness, the hot air flow exhausts the solvent vapors out of the chamber. The drying results from this prototype were very encouraging. For water based anodes there is a 5X drying advantage (time & length of oven) in using ADP over standard drying system and for the NMP based cathodes the reduction in drying time has 3X benefit. For energy savings the power consumption measurements were performed to ADP prototype and compared with the convection standard drying oven. The data collected demonstrated over 40% saving in power consumption with ADP as compared to the convection drying systems. The energy savings are one of the operational cost benefits possible with ADP. To further speed up the drying process, the ADP prototype was explored as a booster module before the convection oven and for the electrode material being evaluated it was possible to increase the drying speed by a factor of 4, which could not be accomplished with the standard dryer without surface defects and cracks. The instantaneous penetration of microwave in the entire slurry thickness showed a major advantage in rapid drying of the electrode materials. For the existing electrode materials, the material analysis and cell characterization data from ADP dried electrodes showed equivalent (or slightly better) performance. However, for high loading and thicker electrode materials (for high energy densities) the ADP advantages are more prominent. There was less binder migration, the resistance was lower hence the current capacities and retention of the battery cells were higher. The success of the project has enabled credible communications with commercial end users as well as battery coating line integrators. Goal is to scale ADP up for high volume manufacturing of Li-ion battery electrodes. The implementation of ADP in high volume manufacturing will reduce a high cost production step to bring the overall price of Li-ion batteries down. This will ultimately have a positive impact on the public by making electric and hybrid vehicles more affordable.

25 ENERGY STORAGE↗

Neutron tomography of porous aluminum electrodes used in electrocoagulation of groundwater

In this work, neutron computed tomography (CT) is employed to investigate the dissolution of porous aluminum electrodes during electrocoagulation (EC). Porous electrodes were chosen in efforts to reduce electric power requirements by using larger surface-area electrodes, having both inner and outer surface, for the EC process. Neutron CT allowed 3D reconstruction of the porous electrodes, and image analysis provided the volume of each electrode vs. thickness, which can indicate whether the inner surface is effectively involved in EC reactions. For the anode, the volume decreased uniformly throughout the thickness of the electrode, indicating that both the outer and inner surface participated in electrochemical dissolution, while the volume of the cathode increased uniformly vs. thickness, indicating deposition of material on both the outer and inner surface. The attenuation coefficient vs. thickness, increased for both anode and cathode, indicating surface chemistry changes. For the anode, the attenuation coefficient increased slightly but uniformly, probably due to aluminum oxide formation on the surface of the anode. For the cathode, the attenuation coefficient increased more than for the anode and nonuniformly. The higher increase in the attenuation coefficient for the cathode is due to precipitation of aluminum hydroxide on the electrode surface, which added hydrogen. Image analysis also showed that, although the attenuation coefficient increased throughout the thickness of the electrode, most of the hydroxide deposition occurred on the outer surface. Energy analysis showed that porous electrodes can be used to reduce process energy requirements by as much as 4 times compared to solid electrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thin Film Electrodes for Anodic Stripping Voltammetry: A Mini-Review

Anodic stripping voltammetry (ASV) is a powerful electrochemical analytical technique that allows for the detection and quantification of a variety of metal ion species at very low concentrations in aqueous media. While early, traditional ASV measurements relied on macroscopic electrodes like Hg drop electrodes to provide surfaces suitable for plating/stripping, more recent work on the technique has replaced these electrodes with thin film metal electrodes generated in situ . Such electrodes are plated alongside the analyte species onto the surface of a primary electrode, producing a composite metal electrode from which the analyte(s) can then be stripped, identified, and quantified. In this minireview, we will explore the development and use of these unique electrodes in a variety of different applications. A number of metals (e.g., Hg, Bi, Sn, etc.) have shown promise as thin film ASV electrodes in both acidic and alkaline media, and frequently multiple metals in addition to the analyte of interest are deposited together to optimize the plating/stripping behavior, improving sensitivity. Due to the relatively simple nature of the measurement and its suitability for a wide range of pH, it has been used broadly: To measure toxic metals in the environment, characterize battery materials, and enable biological assays, among other applications. We will discuss these applications in greater detail, as well as provide perspective on future development and uses of these thin film electrodes in ASV measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diagnostics for the biased electrode experiment on NSTX

A linear array of four small biased electrodes was installed in NSTX in an attempt to control the width of the scrape-off layer by creating a strong local poloidal electric field. The set of electrodes was separated poloidally by a 1 cm gap between electrodes and were located slightly below the midplane of NSTX, 1 cm behind the rf antenna, and oriented so that each electrode is facing approximately normal to the magnetic field. Each electrode can be independently biased to +/- 100 V. Present power supplies limit the current on two electrodes to 30 A and the other two to 10 A each. The effect of local biasing was measured with a set of Langmuir probes placed between the electrodes and another set extending radially outward from the electrodes, and also by the gas puff imaging diagnostic located 1 m away along the magnetic field lines intersecting the electrodes. Two fast cameras were also aimed directly at the electrode array. The hardware and controls of the biasing experiment will be presented and the initial effects on local plasma parameters will be discussed.

99 GENERAL AND MISCELLANEOUS↗