Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrochemical analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Addressing the Challenge of Electrochemical Ionomer Oxidation in Future Anion Exchange Membrane Water Electrolyzers

Hydrogen production through anion-exchange membrane water electrolyzers (AEMWEs) offers cost advantages over proton-exchange membrane counterparts, mainly due to the good oxygen evolution reaction (OER) activity of platinum-group-metal-free catalysts in alkaline environments. However, the electrochemical oxidation of ionomers at the OER catalyst interface can decrease the local electrode pH, which limits AEMWE performance. Various strategies at the single-cell-level have been explored to address this issue. Here, this work reviews the current understanding of electrochemical ionomer oxidation and strategies to mitigate it, providing our perspective on each approach. Our analysis highlights the competitive adsorption strategy as particularly promising for mitigating ionomer oxidation. This Perspective also outlines future directions for advancing high-performance alkaline AEMWEs and other energy devices using hydrocarbon ionomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolving Atomic-Scale Structure and Chemical Coordination in High-Entropy Alloy Electrocatalysts for Structure–Function Relationship Elucidation

The recent breakthrough in confining five or more atomic species in nanocatalysts, referred to as high-entropy alloy nanocatalysts (HEAs), has revealed the possibilities of multielemental interactions that can surpass the limitations of binary and ternary electrocatalysts. The wide range of potential surface configurations in HEAs, however, presents a significant challenge in resolving active structural motifs, preventing the establishment of structure-function relationships for rational catalyst design and optimization. Here, we present a methodology for creating sub-5 nm HEAs using an aqueous-based peptide-directed route. Using a combination of pair distribution function and X-ray absorption spectroscopy, HEA structure models are constructed from reverse Monte Carlo modeling of experimental data sets and showcase a clear peptide-induced influence on atomic-structure and chemical miscibility. Coordination analysis of our structure models facilitated the construction of structure-function correlations applied to electrochemical methanol oxidation reactions, revealing the complex interplay between multiple metals that leads to improved catalytic properties. Our results showcase a viable strategy for elucidating structure-function relationships in HEAs, prospectively providing a pathway for future materials design.

36 MATERIALS SCIENCE↗

Multidimensional visualization of the dynamic evolution of Li metal via in situ/operando methods

The growing demands for high-energy density electrical energy storage devices stimulate the coupling of conversion-type cathodes and lithium (Li) metal anodes. While promising, the use of these “Li-free” cathodes brings new challenges to the Li anode interface, as Li needs to be dissolved first during cell operation. In this study, we have achieved a direct visualization and comprehensive analysis of the dynamic evolution of the Li interface. The critical metrics of the interfacial resistance, Li growth, and solid electrolyte interface (SEI) distribution during the initial dissolution/deposition processes were systematically investigated by employing multidimensional analysis methods. They include three-electrode impedance tests, in situ atomic force microscopy, scanning electrochemical microscopy, and cryogenic scanning transmission electron microscopy. The high-resolution imaging and real-time observations show that a loose, diffuse, and unevenly distributed SEI is formed during the initial dissolution process. This leads to the dramatically fast growth of Li during the subsequent deposition, deviating from Fick’s law, which exacerbates the interfacial impedance. The compactness of the interfacial structure and enrichment of electrolyte species at the surface during the initial deposition play critical roles in the long-term stability of Li anodes, as revealed by operando confocal Raman spectroscopic mapping. In conclusion, our observations relate to ion transfer, morphological and structural evolution, and Li (de)solvation at Li interfaces, revealing the underlying pathways influenced by the initial dissolution process, which promotes a reconsideration of anode investigations and effective protection strategies.

25 ENERGY STORAGE↗

Development of lithium ion conducting interface between lithium metal and a lithium ion conducting ceramic using block polymers

The lithium-air (Li-air) technology developed by EDF uses an air electrode which works with an aqueous electrolyte, which prevent the use of unprotected lithium metal electrode. A Li+ ionic conductor glass ceramic is used to separate the aqueous electrolyte compartment from the negative lithium electrode. However, this glass-ceramic is not stable in contact with lithium, it is thus necessary to add a protective buffer layer. In another hand, this protection should ideally resist to lithium dendritic growth. It is in this context that this research project which has as goal the development of a protective buffer layer based on block copolymer electrolytes (BCE) between the lithium metal and the lithium ionic conductor ceramic, for lithium-air battery. In a first part, the BCE is studied in lithium-lithium symmetric cells, in order to determine their electrochemical properties such as ionic conductivity, steady state transference number, and finally their resistance to dendritic growth during cycling. Several characterization techniques were employed and especially hard X-ray micro-tomography to analyze the lithium morphology before and after cycling. For single-ion BCE, we expect to suppress dendritic growth, however, we report here for the first time, the visualization of a homogeneous growth of lithium but the formation of dense lithium objects. In another part, the composite BCE-ceramic is studied by electrochemical impedance spectroscopy (EIS). The cycling of lithium-composite-lithium symmetric cells and the analysis of the EIS measurement after each cycle permit to determine if the dendrites have cross the protective layer and are in contact with the ceramic. Besides, the quantification of the polarization loss at the interface polymer-ceramic is evaluated by polarization experiments. This contribution is found to be small.

36 MATERIALS SCIENCE↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intercomparison between ozone profiles measured above Spitsbergen by lidar and sonde techniques

This paper compares coincident ozone profile measurements by electrochemical sondes and lidar performed at Ny-Alesund/Spitsbergen. A detailed height dependent statistical analysis of the differences between these complementary methods was performed for the overlapping altitude region (13-35 km). The data set comprises ozone profile measurements conducted between Jan. 1989 and Jan. 1991. Differences of up to 25 percent were found above 30 km altitude.

Fabian, Rolf↗

Ozonesonde Quality Assurance: JOSIE-SHADOZ (2017) and SHALLOTS (2018)

Ozonesonde data constitute a mainstay of satellite calibration and are used for climatologies and analysis of trends, especially in the lower stratosphere where satellites are most uncertain. The electrochemical-concentration cell (ECC) ozonesonde has been deployed at ~100 stations worldwide since the 1960s, with changes over time in manufacture and procedures, including details of the cell chemical solution and data processing. As a consequence, there are biases among different stations and discontinuities in profile timeseries from individual site records. Since 1996 the Jülich [Germany] Ozone Sonde Intercomparison Experiment (JOSIE) has periodically tested ozonesondes in a simulation chamber designated the World Calibration Centre for Ozonesondes by WMO. In October- November 2017 a JOSIE campaign evaluated the sondes and procedures used in SHADOZ (Southern Hemisphere Additional Ozonesondes), a 14-station tropical and subtropical network. A distinctive feature of the 2017 JOSIE was that the tests were conducted by operators from eight SHADOZ stations; Nairobi, Natal, Irene, Costa Rica, Paramaribo, Reunion, Hanoi, Kuala Lumpur. Experimental protocols and preliminary results for the SHADOZ sonde configurations, which represent most of those in use today, are described. SHADOZ stations that follow WMO-recommended protocols record total ozone within 3% of the JOSIE reference instrument. Instrument biases noted in prior JOSIE and field tests like BESOS (2004) were noted in JOSIE-2017, with maximum effect in the stratosphere. In June 2018 we organized a series of dual launches during the OWLETS II campaign in the Maryland and Chesapeake Bay area (SHALLOTS = SHADOZ-OWLETS ParaLLel Ozonesonde Test Study). Instrument and solution types were varied as in JOSIE-2017 and three radiosonde-ozonesonde variants were tested. An example of a parallel sampling in SHALLOTS, from a Greenbelt EnSCI-iMet sonde combination flown with the Wallops SPCLMS package, is illustrated in the Figure. The result was a range of biases but in general the instrument combination (EnSCI-iMet) deployed at 11 SHADOZ stations recorded ~5-10% less ozone in the stratosphere than the SPC ECC sonde flown with a Vaisala or LMS system. These 2017 and 2018 results and prior JOSIEs demonstrate that regular testing is essential to maintain best practices in ozonesonde operations and to ensure high-quality data for the ozone assessment communities.

Quality assurance↗

Frequency response of electrochemical cells

The main objective was to examine the feasibility of using frequency response techniques (1) as a tool in destructive physical analysis of batteries, particularly for estimating electrode structural parameters such as specific area, porosity, and tortuosity and (2) as a non-destructive testing technique for obtaining information such as state of charge and acceptability for space flight. The phenomena that contribute to the frequency response of an electrode include: (1) double layer capacitance; (2) Faradaic reaction resistance; (3) mass transfer of Warburg impedance; and (4) ohmic solution resistance. Nickel cadmium cells were investigated in solutions of KOH. A significant amount of data was acquired. Quantitative data analysis, using the developed software, is planned for the future.

Thomas, Daniel L.↗

Structural and chemical evolutions of a magnesium vanadium oxide cathode under electrochemical cycling in magnesium batteries

The design of cathode materials that remain chemically and structurally stable during repetitive ion insertion and extraction poses a significant challenge in developing multivalent batteries. The cycling stability of traditional metal oxide-based cathode is challenged by sluggish diffusion of multivalent cations and parasitic reactivity at interfacial regimes, including the cathode electrolyte interphase layer (CEI). Understanding the reactions at the cathode-electrolyte interface, particularly those induced by non-stoichiometric surface layers, is a crucial design parameter for both cathode materials and electrolytes. Here, in this study, we employed multimodal analysis, including in situ and ex situ X-ray photoelectron spectroscopy (XPS), high resolution transmission electron microscopy (TEM) and electrochemical impedance spectroscopy (EIS) to examine the surface reactions and subsequent structural and chemical evolutions of the CEI on high voltage magnesium vanadium oxide (MgV 2 O 4 ) spinel cathode during the Mg 2+ insertion/extraction processes. The results revealed that the presence of non-stoichiometric surface layers in the magnesium vanadium oxide cathode drive the decomposition of bis(trifluoromethanesulfonyl)imide (TFSI - ) anion, leading to the formation of the CEI layer. The CEI layer could inhibit the Mg 2+ ion transfer processes. Accompanying this reactivity-driven degradation, the magnesium vanadium oxide cathode undergoes pulverization, forming clusters of nanosized particles. This process likely improves cycling ability by creating new intercalation sites and shortening the diffusion pathway for the Mg 2+ cations. This study demonstrates that controlling surface stoichiometry and engineering morphological properties are critical design parameters for high performance cathodes for multivalent batteries.

25 ENERGY STORAGE↗

Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement

Nuclear fission is an energy source that can provide consistent power with very low associated carbon emissions. However, management of the used nuclear fuel is an important aspect of the application of nuclear power. Recycling of useful components from used fuel is an attractive option, but this involves chemical processing of the fuel. Possible chemical separation technologies that might be used in this regard are sensitive to solution pH. Raman spectroscopy is a promising technique for monitoring the pH of solutions in real time. Classical pH probes are too fragile to be used in the harsh environments encountered in nuclear fuel processing. Raman probes are robust and can withstand these harsh environments to track pH. Coupled with chemometric analysis, the demonstration of the use of Raman spectroscopy to track and predict the pH in carboxylate-buffered systems is made possible. Utilizing this spectroscopy in conjunction with Programmable Logic Controllers mimics industrial control systems used in many modern industrial settings. This showcases a pragmatic approach toward leveraging Raman spectroscopy and chemometric model outputs as inputs for a real-time control system. The model to predict pH created by chemometrics proved to be successful in tracking pH. The optimal pH for TALSPEAK extraction of lanthanides and actinides from aqueous solution is known to proceed in a narrow pH range of around pH = 2.8 ± 0.1. This study uses Raman optical monitoring and automated control to return and maintain solution pH within this range after acid or base perturbations move the solution pH well outside this region. Root-mean-square errors show that pH changes measured using Raman spectroscopy on the batch process solution are reliably measured and used to automatically correct and maintain solution pH. Measurement of solution pH tracks favorably with electrochemical pH probe comparison measurements. As a result, the ability to showcase Raman spectroscopy paired with chemometrics analysis acts as a durable, better alternative data source compared to traditional pH probes to optimize the separation efficiency in the used nuclear fuel processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A refraction correction for buried interfaces applied to in situ grazing-incidence X-ray diffraction studies on Pd electrodes

In situ characterization of electrochemical systems can provide deep insights into the structure of electrodes under applied potential. Grazing-incidence X-ray diffraction (GIXRD) is a particularly valuable tool owing to its ability to characterize the near-surface structure of electrodes through a layer of electrolyte, which is of paramount importance in surface-mediated processes such as catalysis and adsorption. Corrections for the refraction that occurs as an X-ray passes through an interface have been derived for a vacuum–material interface. In this work, a more general form of the refraction correction was developed which can be applied to buried interfaces, including liquid–solid interfaces. Furthermore, the correction is largest at incidence angles near the critical angle for the interface and decreases at angles larger and smaller than the critical angle. Effective optical constants are also introduced which can be used to calculate the critical angle for total external reflection at the interface. This correction is applied to GIXRD measurements of an aqueous electrolyte–Pd interface, demonstrating that the correction allows for the comparison of GIXRD measurements at multiple incidence angles. This work improves quantitative analysis of d-spacing values from GIXRD measurements of liquid–solid systems, facilitating the connection between electrochemical behavior and structure under in situ conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scanning Electrochemical Microscopy for Kinetic Investigations in Viscous Deep Eutectic Solvents: Identifying Practical Approach Curves and Deviations from Electron Transfer Models

Determining heterogeneous electrochemical electron transfer (ET) kinetics in electrolytes with a wide range of physical properties is of great interest for achieving high-performance redox flow batteries. Among such electrolytes, concentrated hydrogen-bonded electrolytes (CoHBEs), including deep eutectic solvents (DESs), have recently garnered significant attention. Unfortunately, traditional Tafel analysis using macroelectrodes often encounters issues with mass transfer limitations in CoHBEs with high viscosities, thereby restricting kinetic analysis to a narrow potential window. Here, in this work, we introduce a methodology for evaluating ET kinetics in viscous DES using the scanning electrochemical microscopy (SECM). We first determined practical solutions to SECM tip positioning in ethaline DES, which yield pseudopositive feedback responses. Lattice Boltzmann method (LBM) simulations helped us rationalize the impact of the fluid and concentration fields, as well as tip geometry, tip approach velocity v, and the solvent viscosity ηs, on the shape of the approach curves. In addition to successfully recreating approach curves over a variety of conditions, we found that approaching a conductor ensured a practical point where the normalized tip response (Ni T = 2) converged at L = 0.7 within ∼10% error regardless of tip velocity. With positioning capabilities at hand, we investigated the kinetics of Fe 3+ /Fe 2+ redox couple in aqueous and the ethaline media. The experimental kinetic results were interpreted using the Butler–Volmer (BV) and Marcus–Hush–Chidsey (MHC) models. For ethaline, a nonideal kinetic behavior was observed, potentially attributed to solvent dynamics within DESs or to the interplay of chloride anions in the charge transfer process.

electrodes↗

Design and Optimization of the Direct Recycling of Spent Li-Ion Battery Cathode Materials

Direct regeneration of spent Li-ion batteries based on the hydrothermal relithiation of cathode materials is a promising next-generation recycling technology. In order to demonstrate the feasibility of this approach at a large scale, we systematically design and optimize the process parameters to minimize both energy and raw material costs. Specifically, the effects of regenerative processing parameters on the composition, structure, and electrochemical performance of the regenerated cathode materials are investigated via systematic characterization and testing. From this analysis, it was found that the raw material costs can be substantially reduced by either replacing the typically employed 4 M LiOH solution by a cost-effective mixture of 0.1 M LiOH and 3.9 M KOH or recycling of the concentrated 4 M LiOH for continuous relithiation processes. Finally, life cycle analysis suggests that this strategy results in reduced energy consumption and greenhouse gas emissions, leading to an increased potential revenue, particularly when compared with hydro- and pyrometallurgical recycling methods.

25 ENERGY STORAGE↗

Bipolar Membrane Capacitive Deionization for the Selective Capture of Lithium Ions from Brines and Conversion to Lithium Hydroxide

Meeting the increasing demand for lithium in vehicle electrification and renewable energy storage requires innovations in lithium-ion (Li + ) separations. Traditional solar evaporation methods for lithium recovery are slow and consume tremendous volumes of water and secondary chemicals (acids and bases). This study introduces a bipolar membrane capacitive deionization (BPM-CDI) unit for direct lithium extraction and LiOH production without the external addition of acids and bases. Utilizing de-lithiated lithium-iron-phosphate (LFP) coated carbon cloth electrodes, the BPM-CDI unit demonstrates selective Li + capture over competing ions. Molecular dynamics simulations and H-cell experiments elucidate pH inversion mechanisms during Li + release, yielding LiOH. The BPM-CDI platform efficiently removes Li + from synthetic brines featuring 8x higher Mg 2+ concentrations (200 ppm Mg 2+ ) and 26x higher Na + concentrations (682 ppm Na + ), achieving a LiOH concentration of 124 ppm (36 ppm Li + ) after 8 cycles of recirculation. Post-mortem analysis confirms electrode integrity and stability. BPM-CDI integrated with selective electrodes is a promising electrochemical separation-reactor platform for lithium recovery while producing LiOH.

Kulkarni, Tanmay↗

Energy Storage for Manufacturing and Industrial Decarbonization (Energy StorM)

This report summarizes the needs, challenges, and opportunities associated with carbon-free energy and energy storage for manufacturing and industrial decarbonization. Energy needs and challenges for different manufacturing and industrial sectors (e.g., cement/steel production, chemicals, materials synthesis) are identified. Key issues for industry include the need for large, continuous on-site capacity (tens to hundreds of megawatts), compatibility with existing infrastructure, cost, and safety. Energy storage technologies that can potentially address these needs, which include electrochemical, thermal, and chemical energy storage, are presented along with key challenges, gaps, and integration issues. Analysis tools to value energy storage technologies in the context of manufacturing and industrial decarbonizations are also presented. Material is drawn from the Energy Storage for Manufacturing and Industrial Decarbonization (Energy StorM) Workshop, held February 8 - 9, 2022. The objective was to identify research opportunities and needs for the U.S. Department of Energy as part of its Energy Storage Grand Challenge program.

25 ENERGY STORAGE↗

The Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm (figures I and 2). The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Using an array of ion-specific electrodes (ISEs), cyclic voltammetry, and electrochemical techniques, the chemistry cells will wet soil samples for measurement of basic soil properties of pH, redox potential, and conductivity. Total dissolved material, as well as targeted ions will be detected to the ppm level, including important exobiological ions such as Na, K+, Ca++, Mg++, NH4+, Cl, S04-, HC03, as well as more toxic ions such as Cu++, Pb++, Cd++, Hg++, and C104-. MECA's microscopy station combines optical and atomic-force microscopy (AFM) to image dust and soil particles from millimeters to nanometers in size. Illumination by red, green, and blue LEDs is augmented by an ultraviolet LED intended to excite fluorescence in the sample. Substrates were chosen to allow experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. To aid in the detection of potentially dangerous quartz dust, an abrasion tool measures sample hardness relative to quartz and a hard glass (Zerodur).

Meloy, Thomas P.↗

Corrosion Study Using Electrochemical Impedance Spectroscopy

Corrosion is a common phenomenon. It is the destructive result of chemical reaction between a metal or metal alloy and its environment. Stainless steel tubing is used at Kennedy Space Center for various supply lines which service the orbiter. The launch pads are also made of stainless steel. The environment at the launch site has very high chloride content due to the proximity to the Atlantic Ocean. Also, during a launch, the exhaust products in the solid rocket boosters include concentrated hydrogen chloride. The purpose of this project was to study various alloys by Electrochemical Impedance Spectroscopy in corrosive environments similar to the launch sites. This report includes data and analysis of the measurements for 304L, 254SMO and AL-6XN in primarily neutral 3.55% NaCl. One set of data for 304L in neutral 3.55%NaCl + 0.1N HCl is also included.

Farooq, Muhammad Umar↗