SEARCH · Engineering Papers
Results for “Display system”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Evaluation of Low Environmental Impact Distributed Scroll Booster Technology for Supermarket Refrigeration
A distributed scroll booster refrigeration system is proposed as an alternative for current refrigeration systems used in supermarket applications. The distributed scroll booster system is configured to enable the use of low-pressure refrigerants such as R-1234yf, which has a global warming potential (GWP) of less than 1, in a cycle configuration that employs a two-stage compression process. This scroll booster system is comprised of medium-temperature compressors (high stage) coupled with low-temperature compressors (low stage). This two-stage system architecture allows both low-temperature and medium-temperature refrigerated display cases to be integrated in the same system. By design, this system reduces the refrigerant charge, produces higher efficiencies (two-stage compression), uses existing components minimizing cost impact, and will be able to use ultra-low GWP class A2L (low toxicity and low flammability) refrigerants such as R-1234yf when standards and building codes are updated (expected by 2025).
TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light
Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.
A Sensemaking Perspective on Situation Awareness in Power Grid Operations
With increasing complexity and interconnectivity of the electric power grid, the scope and complexity of grid operations continues to grow. New paradigms are needed to guide research to improve operations by enhancing situation awareness of operators. Research on human factors/situation awareness is described within a taxonomy of tools and approaches that address different levels of cognitive processing. While user interface features and visualization approaches represent the predominant focus of human factors studies of situation awareness, this paper argues that a complementary level, sensemaking, deserves further consideration by designers of decision support systems for power grid operations. A sensemaking perspective on situation aware-ness may reveal new insights that complement ongoing human factors research, where the focus of the investigation of errors is to understand why the decision makers experienced the situation the way they did, or why what they saw made sense to them at the time.
A Model of Cyclic Transcriptomic Behavior in Cyanobacterium Cyanothece sp. ATCC 51142
Systems biology attempts to reconcile large amounts of disparate data with existing knowledge to provide models of functioning biological systems. Useful and predictive models aim to summarize complex and dynamic processes and represent the relationships between these processes. The cyanobacterial Cyanothece species Strain sp. ATCC 51142 is an excellent candidate for such systems studies because: (i) it displays tight functional regulation as it must separate the opposing processes of oxygen-generating photosynthesis and oxygen-sensitive nitrogen fixation temporally in the same cell, ; (ii) it has robust cyclic patterns at the genetic, protein and metabolomic levels, ; and (iii) and it has potential applications for bioenergy and carbon sequestration, and thus a predictive model of its function is of practical use. We have represented the transcriptomic data from Cyanothece 51142 under diurnal light/dark cycles as a high-level functional abstraction and describe development of a predictive in silico model of diurnal and circadian behavior in terms of regulatory and metabolic processes in Cyanothece 51142. Our model provides a way to integrate disparate data types into a framework that can be used to explain behavior, generate high-quality predictions for validation, and to suggest future experiments. We show that incorporating network topology into the model improves performance in terms of our ability to explain the behavior of the system under new conditions. The model presented robustly describes transcriptomic behavior of Cyanothece 51142 under different cyclic and non-cyclic growth conditions robustly, and represents a significant advance in the understanding of gene regulation in this important organism.
Solvation in Space-time: Pretransition Effects in Trajectory Space
We demonstrate pretransition effects in space-time in trajectories of systems in which the dynamics displays a first-order phase transition between distinct dynamical phases. These effects are analogous to those observed for thermodynamic first-order phase transitions, most notably the hydrophobic effect in water. Considering the (infinite temperature) East model as an elementary example, we study the properties of "space-time solvation" by examining trajectories where finite space-time regions are conditioned to be inactive in an otherwise active phase. We find that solvating an inactive region of space-time within an active trajectory shows two regimes in the dynamical equivalent of solvation free energy: An "entropic" small solute regime in which uncorrelated fluctuations are sufficient to evacuate activity from the solute, and an "energetic" large solute regime which involves the formation of a solute-induced inactive domain with an associated active-inactive interface bearing a dynamical interfacial tension. We also show that as a result of this dynamical interfacial tension there is a dynamical analog of the hydrophobic collapse that drives the assembly of large hydrophobes in water. We discuss the general relevance of these results to the properties of dynamical fluctuations in systems with slow collective relaxation such as glass formers.
Building Energy Information Systems: User Case Studies
Measured energy performance data are essential to national efforts to improve building efficiency, as evidenced in recent benchmarking mandates, and in a growing body of work that indicates the value of permanent monitoring and energy information feedback. This paper presents case studies of energy information systems (EIS) at four enterprises and university campuses, focusing on the attained energy savings, and successes and challenges in technology use and integration. EIS are broadly defined as performance monitoring software, data acquisition hardware, and communication systems to store, analyze and display building energy information. Case investigations showed that the most common energy savings and instances of waste concerned scheduling errors, measurement and verification, and inefficient operations. Data quality is critical to effective EIS use, and is most challenging at the subsystem or component level, and with non-electric energy sources. Sophisticated prediction algorithms may not be well understood but can be applied quite effectively, and sites with custom benchmark models or metrics are more likely to perform analyses external to the EIS. Finally, resources and staffing were identified as a universal challenge, indicating a need to identify additional models of EIS use that extend beyond exclusive in-house use, to analysis services.
Quality status display for a vibration welding process
A system includes a host machine and a status projector. The host machine is in electrical communication with a collection of sensors and with a welding controller that generates control signals for controlling the welding horn. The host machine is configured to execute a method to thereby process the sensory and control signals, as well as predict a quality status of a weld that is formed using the welding horn, including identifying any suspect welds. The host machine then activates the status projector to illuminate the suspect welds. This may occur directly on the welds using a laser projector, or on a surface of the work piece in proximity to the welds. The system and method may be used in the ultrasonic welding of battery tabs of a multi-cell battery pack in a particular embodiment. The welding horn and welding controller may also be part of the system.
Detecting fission from special nuclear material sources
A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a graphing component that displays the plot of the neutron distribution from the unknown source over a Poisson distribution and a plot of neutrons due to background or environmental sources. The system further includes a known neutron source placed in proximity to the unknown source to actively interrogate the unknown source in order to accentuate differences in neutron emission from the unknown source from Poisson distributions and/or environmental sources.
SU-E-I-22: Dependence On Calibration Phantom and Field Area of the Conversion Factor Used to Calculate Skin Dose During Neuro-Interventional Fluoroscopic Procedures
Purpose: To determine the appropriate calibration factor to use when calculating skin dose with our real-time dose-tracking system (DTS) during neuro-interventional fluoroscopic procedures by evaluating the difference in backscatter from different phantoms and as a function of entrance-skin field area. Methods: We developed a dose-tracking system to calculate and graphically display the cumulative skin-dose distribution in real time. To calibrate the DTS for neuro-interventional procedures, a phantom is needed that closely approximates the scattering properties of the head. We compared the x-ray backscatter from eight phantoms: 20-cm-thick solid water, 16-cm diameter water-filled container, 16-cm CTDI phantom, modified-ANSI head phantom, 20-cm-thick PMMA, Kyoto-Kagaku PBU- 50 head, Phantom-Labs SK-150 head, and RSD RS-240T head. The phantoms were placed on the patient table with the entrance surface at 15 cm tube-side from the isocenter of a Toshiba Infinix C-arm, and the entrance-skin exposure was measured with a calibrated 6-cc PTW ionization chamber. The measurement included primary radiation, backscatter from the phantom and forward scatter from the table and pad. The variation in entrance-skin exposure was also measured as a function of the skin-entrance area for a 30x30 cm by 20-cm-thick PMMA phantom and the SK-150 head phantom using four different added beam filters. Results: The entranceskin exposure values measured for eight different phantoms differed by up to 12%, while the ratio of entrance exposure of all phantoms relative to solid water showed less than 3% variation with kVp. The change in entrance-skin exposure with entrance-skin area was found to differ for the SK-150 head compared to the 20-cm PMMA phantom and the variation with field area was dependent on the added beam filtration. Conclusion: To accurately calculate skin dose for neuro-interventional procedures with the DTS, the phantom for calibration should be carefully chosen since different phantoms can contribute different backscatter for identical exposure parameters. Research supported in part by Toshiba Medical Systems and NIH Grants R43FD0158401, R44FD0158402 and R01EB002873.
Thoreau: A fully-buried wireless underground sensor network in an urban environment
This paper describes the design and deployment of a functional Wireless Underground Sensor Network (WUSN) on a university campus. This is an unique system that is operational over a large area and over a long period of time, providing real time monitoring of the environment with the data being curated and displayed on an open website. The system details, including the architecture, node design, user interface, and deployment are provided. Initial measurement results are analyzed to show the functionality and performance of the system.
An investigation into positron emission tomography contouring methods across two treatment planning systems
Positron emission tomography (PET) imaging has been used to provide additional information regarding patient tumor location, size, and staging for radiotherapy treatment planning purposes. This additional information reduces interobserver variability and produces more consistent contouring. It is well recognized that different contouring methodology for PET data results in different contoured volumes. The goal of this study was to compare the difference in PET contouring methods for 2 different treatment planning systems using a phantom dataset and a series of patient datasets. Contouring methodology was compared on the ADAC Pinnacle Treatment Planning System and the CMS XiO Treatment Planning System. Contours were completed on the phantom and patient datasets using a number of PET contouring methods—the standardized uptake value 2.5 method, 30%, 40%, and 50% of the maximum uptake method and the signal to background ratio method. Differences of >15% were observed for PET-contoured volumes between the different treatment planning systems for the same data and the same PET contouring methodology. Contoured volume differences between treatment planning systems were caused by differences in data formatting and display and the different contouring tools available. Differences in treatment planning system as well as contouring methodology should be considered carefully in dose-volume contouring and reporting, especially between centers that may use different treatment planning systems or those that have several different treatment planning systems.
Cybersecurity Vulnerability Assessment Methodologies for Nuclear Power Plants
As any mechanical system ages, broken or outdated parts must be replaced; nuclear power plants (NPPs) are no different. The average age of a NPP in the United States' aging fleet of commercial reactors is 35 years, with many of these plants operating under extensions of their original licenses. These plants, originally designed in the 1960's and 1970's, are controlled by analog instrumentation and control (I and C) systems, and have since been upgraded (to varying degrees) to hybrid analog-digital systems. As these NPPs are upgraded to continue operating and to meet more stringent safety requirements imposed by the Nuclear Regulatory Commission (NRC), the implementation of digital systems to monitor and run the power plant introduces new vulnerabilities that must be addressed. The main objectives of a vulnerability assessment (VA) are to identify, quantify, and prioritize all of the susceptibilities inherent in a system. This allows for all weaknesses to be analyzed, and for the most serious concerns to be addressed first. Traditional VA methodologies deal with the analysis of physical systems associated with the NPP; with the introduction of digital control systems and computer networks, these methodologies must be expanded to include these fundamentally different systems and vulnerability concerns. Digital systems have been used in NPPs since the 1980's, but only for non-safety control systems; attacks on these systems were not deemed consequential, and no dedicated VA methodology was required. However, 'all new NPPs are being designed with integrated digital instrumentation and control systems as the backbone of protection, controls, alarms, and display and monitoring'. This gives rise to new vulnerabilities such as disrupted data displays, the suppression of critical alarms, or unauthorized access to secure systems from connected networks. The NRC released formal cybersecurity regulations in March 2009 (10 CFR 73.54), as well as a guide for the program in January 2010 (RG 5.71). However, the regulations and guide provide limited insight on how to identify these vulnerabilities; the focus is on remediating them once found. Hence, there is a need for a comprehensive, systematic methodology to conduct a VA on digital computer and communications and network systems. In this paper, we review traditional VA methodologies and discuss relevant cases. Then we discuss challenges to vulnerabilities within the context of modernization of the fleet and what needs to be done to address this issue.
Development of autonomous gamma dose logger for environmental monitoring
Continuous monitoring and archiving of background radiation levels in and around the nuclear installation is essential and the data would be of immense use during analysis of any untoward incidents. A portable Geiger Muller detector based autonomous gamma dose logger (AGDL) for environmental monitoring is indigenously designed and developed. The system operations are controlled by microcontroller (AT89S52) and the main features of the system are software data acquisition, real time LCD display of radiation level, data archiving at removable compact flash card. The complete system operates on 12 V battery backed up by solar panel and hence the system is totally portable and ideal for field use. The system has been calibrated with Co-60 source (8.1 MBq) at various source-detector distances. The system is field tested and performance evaluation is carried out. This paper covers the design considerations of the hardware, software architecture of the system along with details of the front-end operation of the autonomous gamma dose logger and the data file formats. The data gathered during field testing and inter comparison with GammaTRACER are also presented in the paper. AGDL has shown excellent correlation with energy fluence monitor tuned to identify {sup 41}Ar, proving its utility for real-time plume tracking and source term estimation.
Investigating the Role of VR in a Simulation-Based Medical Planning System for Coronary Interventions
Virtual reality (VR) based computational fluid dynamics (CFD) simulations are emerging as a viable solution to guide complex surgical or invasive procedures, such as percutaneous coronary intervention (PCI), as they enable a realistic first-person experience of underlying patient anatomy and physiology. Realistic VR experience can be assessed by immersion, an objective VR property. However, it remains unclear how immersion influences virtual PCI procedures and what level of immersion is required. This study answers both these questions by evaluating the application of a CFD-based VR system and comparing semi-immersive and fully immersive VR displays. Nine patient-specific arterial models were simulated using CFD and used to conduct a quantitative user evaluation (n = 31) with both types of VR displays. The findings of this study reveal that VR immersion significantly improves the accuracy of simulated stent placement in complex arterial geometries, relative to traditional desktops with no immersion (p < 0.05). Higher accuracy is noted by the use of semi-immersive VR display, which offers higher display fidelity as compared to the fully immersive VR display (p < 0.05). Interestingly, CFD data mapped on to arterial geometries strongly influences the location of stent placement. This finding is demonstrated by the lack of significant accuracy deviation between the two immersive displays when CFD data is shown. This study provides compelling evidence that a CFD-based VR system rendered on semi-immersive displays can enable more accurate and efficient stent placement.
All-Glass Metasurfaces for Ultra-Broadband and Large Acceptance Angle Antireflectivity: from Ultraviolet to Mid-Infrared
For many optics technologies, such as display screens, solar cells, laser systems, and eyeglasses, antireflective (AR) coatings are well integrated; these applications frequently benefit from the ability to function as broadband AR. Here, in this work, all-glass metasurfaces are reported on, exhibiting a measured reflectance of 0.18% ± 0.23% per interface, averaged across wavelengths spanning from 350 nm (ultraviolet) to 2350 nm (mid-infrared); to the best of knowledge, this is the first-ever demonstration of an AR layer capable of this. Furthermore, acceptance angles up to 100° (angle of incidence = ±50°) results in % R < 0.6% per interface over the band 350–1300 nm for P-polarization and S-polarization, with wavelength averaged reflectance values 0.04% ± 0.05% and 0.11% ± 0.15%, respectively – another technological first. The process advancements presented here allow for reflectance suppression over a broad range of wavelengths, angles, and polarizations.
Threshold Ionization Spectroscopy and Theoretical Calculations of LnO (Ln = La and Ce)
Mass-analyzed threshold ionization (MATI) spectroscopy was used to measure the vibronic spectra of LnO (Ln = La and Ce). Single-reference coupled cluster and relativistic multireference configuration calculations were carried out to compare with the measured vibronic energies. The spectrum of LaO displays a single vibronic band system, while that of CeO shows multiple ones. The ionization energies of LaO and CeO are measured as 5.2446 (6) and 5.3332(6) eV, respectively, which are a hundredfold improvement over the literature values. The vibrational energies of the neutral molecule and corresponding ion reveal the charge effect on the metal-oxygen bond of both species. The single band system in the spectrum of LaO arises from the transition of the ground state of the neutral molecule with the La(6s 1 )O(2p 6 ) valence configuration to the ground state of the singly charged ion with the La(6s o )O(2p 6 ) configuration. Here, the multiple band systems in the spectrum of CeO are attributed to the spin-orbit coupling for the Ce(4f 1 6s 1 )O(2p 6 ) configuration of the neutral molecule and an excited state for the Ce(4f 1 )O(2p 6 ) configuration of the ion.
Growth, Structure, and Catalytic Properties of ZnO x Grown on CuO x /Cu(111) Surfaces
A catalyst with a ZnO/Cu configuration plays an important role in the synthesis of methanol from CO2 hydrogenation. In this study, scanning tunneling microscopy and X-ray photoelectron spectroscopy (XPS) were used to investigate the growth mode of small coverages of ZnO x , θ oxi < 0.3 monolayer, on a Cu(111) substrate. Our results show that the modes of growth, size, and shape of the ZnO nanoparticles are strongly dependent on the Zn deposition temperature. In a set of experiments, Zn was deposited on Cu(111) or CuO x /Cu(111) surfaces at 300 K with subsequent exposure to O 2 at higher temperatures (400–550 K), which exhibited small particles of ZnO (<20 nm in size) on the surface. The deposition of Zn onto CuO x /Cu(111) at elevated temperatures (450–600 K) in an oxygen ambient produced large ZnO islands (300–650 nm in size), which were very rough and spread over several terraces of Cu(111). XPS/Auger spectra showed that all of the preparation conditions stated above led to the formation ZnO/CuO x /Cu(111) surfaces where the oxidation state of zinc was uniform. In conclusion, catalytic tests showed that all these surfaces were active for the hydrogenation of CO 2 to methanol, but only the systems prepared at 600 K displayed long-term stability under reaction conditions.