Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Display Devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Real-Time Operating System/360

RTOS has a cost savings advantage for real-time applications, such as those with random inputs requiring a flexible data routing facility, display systems simplified by a device independent interface language, and complex applications needing added storage protection and data queuing.

Hoffman, R. L.↗

High-speed data word monitor

Small, portable, self-contained device provides high-speed display of bit pattern or any selected portion of transmission, can suppress filler patterns so that display is not updated, and can freeze display so that specific event may be observed in detail.

Wirth, M. N.↗

Solid-state turn-coordinator display

Light emitting diodes are employed in displays for aircraft instrument applications. Device offers three levels of brightness to compensate for varying degrees of ambient light present in cockpit.

Crouch, R. K.↗

Graphic displays of vector magnetograph data

Graphic displays that have proved useful in dealing with vector magnetograph data are summarized in three settings: real-time control, analysis, and final presentation. Among the topics discussed are: flexible, implicit data-scaling; geometrical transformations; methods of comparing fields (e.g., transverse vs. longitudinal; observed vs. computed; one time vs. another); displaying the magnitude and direction of the transverse field; minimizing the display time of serial graphics devices; graphic file structure; and graphic interaction with operators and observers.

Rabin, D. M.↗

InP (Indium Phosphide): Into the future

Major industry is beginning to be devoted to indium phosphide and its potential applications. Key to these applications are high speed and radiation tolerance; however the high cost of indium phosphide may be an inhibitor to progress. The broad applicability of indium phosphide to many devices will be discussed with an emphasis on photovoltaics. Major attention is devoted to radiation tolerance and means of reducing cost of devices. Some of the approaches applicable to solar cells may also be relevant to other devices. The intent is to display the impact of visionary leadership in the field and enable the directions and broad applicability of indium phosphide.

Brandhorst, Henry W., Jr.↗

Eddy-current inspection of shuttle heat exchanger tube welds

The goal of this project was to develop the system necessary to demonstrate in the laboratory that an eddy current system can inspect the tubes and welds described, screening for the existence of flaws equal in size to, or larger than, the target flaw. The laboratory system was to include the probe necessary to traverse the tubing, the electronics to drive (i.e., electrically excite) the probe and receive and process signals from it, a data display, data recording, and playback devices, and microprocessor software or firmware necessary to operate the system.

Dodd, Casius V.↗

Small convolution kernels for high-fidelity image restoration

An algorithm is developed for computing the mean-square-optimal values for small, image-restoration kernels. The algorithm is based on a comprehensive, end-to-end imaging system model that accounts for the important components of the imaging process: the statistics of the scene, the point-spread function of the image-gathering device, sampling effects, noise, and display reconstruction. Subject to constraints on the spatial support of the kernel, the algorithm generates the kernel values that restore the image with maximum fidelity, that is, the kernel minimizes the expected mean-square restoration error. The algorithm is consistent with the derivation of the spatially unconstrained Wiener filter, but leads to a small, spatially constrained kernel that, unlike the unconstrained filter, can be efficiently implemented by convolution. Simulation experiments demonstrate that for a wide range of imaging systems these small kernels can restore images with fidelity comparable to images restored with the unconstrained Wiener filter.

Reichenbach, Stephen E.↗

General-Purpose Plotting Software

TADPLOT computer program gives researcher general-purpose plotting software package easy to use, quickly creates X-Y plots, and powerful enough to create full-feature publication-quality plots. Enables user to save selected plot information displayed subsequently on several different devices, including "hard-copy" plotters. Postprocessing features that enable user to manipulate and combine plots also available. Written in ANSI STANDARD FORTRAN 77.

Hammond, Dana P.↗

Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

Software↗

Devices based on surface plasmon interference filters

Devices based on surface plasmon filters having at least one metal-dielectric interface to support surface plasmon waves. A multi-layer-coupled surface plasmon notch filter is provided to have more than two symmetric metal-dielectric interfaces coupled with one another to produce a transmission spectral window with desired spectral profile and bandwidth. Such notch filters can form various color filtering devices for color flat panel displays.

Wang, Yu↗

High-resolution, continuous field-of-view (FOV), non-rotating imaging system

A high resolution CMOS imaging system especially suitable for use in a periscope head. The imaging system includes a sensor head for scene acquisition, and a control apparatus inclusive of distributed processors and software for device-control, data handling, and display. The sensor head encloses a combination of wide field-of-view CMOS imagers and narrow field-of-view CMOS imagers. Each bank of imagers is controlled by a dedicated processing module in order to handle information flow and image analysis of the outputs of the camera system. The imaging system also includes automated or manually controlled display system and software for providing an interactive graphical user interface (GUI) that displays a full 360-degree field of view and allows the user or automated ATR system to select regions for higher resolution inspection.

Huntsberger, Terrance L.↗

A New Process for Fabricating Random Silicon Nanotips

An improved process for the fabrication of random arrays of silicon nanotips has been demonstrated to be feasible. Relative to other such processes, this process offers advantages of low cost and simplicity. Moreover, this process can readily be combined with other processes used to fabricate integrated circuits and other monolithic silicon structures. Arrays of silicon nanotips are subjects of research and development efforts directed toward utilizing them as field emitters in flat-panel displays, vacuum microelectronics, and microwave devices. Other silicon-nanotip-fabrication processes developed thus far predominantly include lithography, etching, and/or elaborate deposition steps followed by oxide sharpening steps and are both process intensive as well as expensive. In addition to being cheaper and simpler, the present process can efficiently produce silicon nanotips that range in height from a few microns to several tens of microns and are distributed over large areas. The process mentioned here can be summarized as consisting of (1) the growth of micro-etch masks on a silicon substrate, followed by (2) etching away of the masks, along with some of the substrate, to make an array of sharp tips. In the first step of the process, a cleaned silicon substrate is subjected to reactive ion etching (RIE) in a certain mixture of oxygen and carbon tetrafluoride under radio-frequency excitation. This process step results in the growth of fluorine based compounds in the form of stumps randomly distributed on the substrate. These stumps are known in the art as polymer RIE grass. The dimensions of these stumps are of the order of hundreds of nanometers, the exact values depending on process time and gas composition. The areal density of the stumps decreases with increasing process time as they grow and merge with neighboring stumps. These stumps constitute the micro-etch masks for the next step of the process. In the second step of the process, the substrate covered with the microetch masks is subjected to deep reactive ion etching (DRIE) process, which consists of cycles of reactive ion etching alternating with passivation (the Bosch process). The gas used in the etching substeps is sulfur hexafluoride (SF6); the gas used in the passivation substeps is octafluorocyclobutane (C4F8). The portions of the substrate directly under the RIE grass stubs are etched more slowly than are the portions between the stubs. Hence, what remains at the end of the process, after the stubs and parts of the substrate have been etched away, are silicon spikes where the stubs were (see figure). In a variation of the process, one starts with a silicon or silicon-on-insulator substrate with the intent to etch through the full thickness of the substrate. That is to say, one chooses the thickness so that the DRIE step releases individual nanotips. Such individual silicon nanotips may have utility as microscopic probes in biomedical applications.

Manohara, Harish↗

Motion Sickness and Concerns for Urban Air Mobility Vehicles: A Literature Review

Motion sickness is a general term for a constellation of signs and symptoms, generally due to exposure to abrupt, periodic, or unnatural accelerations, especially when traveling in a vehicle. Motion sickness results from a mismatch of the visual and nonvisual (vestibular and kinesthetic) information, the observed scene and the motion felt or lack of it. Motion sickness onset is associated with a pattern of physiological changes in heart rate, peripheral blood flow, respiration, and skin conductance and the pattern is repeatable for a particular subject but variable between subjects. Demographic factors such as gender and age that affect motion sickness are well known with children, women, and older adults more likely to be susceptible. Often motion sickness is assessed and quantified using variations of the motion sickness susceptibility questionnaires including the Pensacola Diagnostic Rating Scale and the Simulator Sickness Questionnaire. Even though symptoms are easily identified by such questionnaires, they commonly are subjective. Tools such as these questionnaires for screening individuals susceptible to motion sickness are useful, however, they are only mildly predictive. Moreover, models for predicting motion sickness, which have largely been developed for sea sickness, do not consider task characteristics. Predictions of motion sickness rates and prevalence for Urban Air Mobility (UAM) vehicles are not possible at present because data from actual flight or full-fidelity simulation are simply not yet available. Extrapolation from other modes of transportation (i.e., automobiles, buses, trains, boats, other types of aircraft) is difficult because of differences in the motion stimulus experienced, trip duration, and other factors. How UAM vehicles will change the social dynamics of passenger interaction and vehicle interior design changes (e.g., seat orientations) is unknown. Should motion sickness prove to be an issue, vehicle design modifications such as having passengers face forward, providing additional seat recline, giving each person their own climate control for airflow, perhaps ensuring the horizon is visible to all passengers (reducing visual occlusion by the headrest) and visually stabilizing displays on carry-on devices (smart phones, tablets, etc.) may benefit passengers. Several commercial companies provide wearable devices for physiological monitoring that have been validated and are suitable for use with passengers in UAM vehicles or high-fidelity simulators. Potential countermeasures for motion sickness include user-worn devices, anti-motion sickness medications, and non-pharmacological approaches such as biofeedback and Autogenic Feedback Training Exercise. Both simulator and in-vehicle UAM research is needed to evaluate the effectiveness of any potential countermeasure.

motion sickness↗

Methods and apparatus for graphical display and editing of flight plans

Systems and methods are provided for an integrated graphical user interface which facilitates the display and editing of aircraft flight-plan data. A user (e.g., a pilot) located within the aircraft provides input to a processor through a cursor control device and receives visual feedback via a display produced by a monitor. The display includes various graphical elements associated with the lateral position, vertical position, flight-plan and/or other indicia of the aircraft's operational state as determined from avionics data and/or various data sources. Through use of the cursor control device, the user may modify the flight-plan and/or other such indicia graphically in accordance with feedback provided by the display. In one embodiment, the display includes a lateral view, a vertical profile view, and a hot-map view configured to simplify the display and editing of the aircraft's flight-plan data.

Gibbs, Michael J.↗

Visual specification of robot motion

The authors describe the use of stereo pairs of images to specify robot motion. The experimental setup includes a SUN workstation, a PUMA 560 robot, and an Imaging 151 vision system. An X-window environment displays stereo images of the work scene. Image processing is performed to extract linear edge segments from the images and the results are displayed on screen. Using a pointing device, the user selects a group of edges from the object relevant to the task. The 3D structure of this group of features is found by stereo triangulation and they can be displayed in 3D from any point of view. A viewpoint orthogonal to the plane defined by these 3D edges is used to specify the robot position relative to object position. The actual robot will then be moved to the specified position.

Shiu, Y. C.↗

Micro-video display with ocular tracking and interactive voice control

In certain space-restricted environments, many of the benefits resulting from computer technology have been foregone because of the size, weight, inconvenience, and lack of mobility associated with existing computer interface devices. Accordingly, an effort to develop a highly miniaturized and 'wearable' computer display and control interface device, referred to as the Sensory Integrated Data Interface (SIDI), is underway. The system incorporates a micro-video display that provides data display and ocular tracking on a lightweight headset. Software commands are implemented by conjunctive eye movement and voice commands of the operator. In this initial prototyping effort, various 'off-the-shelf' components have been integrated into a desktop computer and with a customized menu-tree software application to demonstrate feasibility and conceptual capabilities. When fully developed as a customized system, the interface device will allow mobile, 'hand-free' operation of portable computer equipment. It will thus allow integration of information technology applications into those restrictive environments, both military and industrial, that have not yet taken advantage of the computer revolution. This effort is Phase 1 of Small Business Innovative Research (SBIR) Topic number N90-331 sponsored by the Naval Undersea Warfare Center Division, Newport. The prime contractor is Foster-Miller, Inc. of Waltham, MA.

Miller, James E.↗

Liquid Crystal on Silicon Wavefront Corrector

A low cost, high resolution, liquid crystal on silicon, spatial light modulator has been developed for the correction of huge aberrations in an optical system where the polarization dependence and the chromatic nature are tolerated. However, the overall system performance suggests that this device is also suitable for real time correction of aberration in human eyes. This device has a resolution of 1024 x 768, and is driven by an XGA display driver. The effective stroke length of the device is 700 nm and 2000 nm for the visible and IR regions of the device, respectively. The response speeds are 50 Hz and 5 Hz, respectively, which are fast enough for real time adaptive optics for aberrations in human eyes. By modulating a wavefront of 2 pi, this device can correct for arbitrary high order wavefront aberrations since the 2-D pixel array is independently controlled by the driver. The high resolution and high accuracy of the device allow for diffraction limited correction of the tip and tilt or defocus without an additional correction loop. We have shown that for every wave of aberration, an 8 step blazed grating is required to achieve high diffraction efficiency around 80%. In light of this, up to 125 waves peak to valley of tip and tilt can be corrected if we choose the simplest aberration. Corrections of 34 waves of aberration, including high order Zernicke terms in a high magnification telescope, to diffraction limited performance (residual wavefront aberration less than 1/30 lambda at 632.8 nm) have been observed at high efficiency.

Pouch, John↗