Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Discrete sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Optimization of deterministic transport parameters for the calculation of the dose distribution around a high dose-rate {sup 192}Ir brachytherapy source

The goal of this work was to calculate the dose distribution around a high dose-rate {sup 192}Ir brachytherapy source using a multi-group discrete ordinates code and then to compare the results with a Monte Carlo calculated dose distribution. The unstructured tetrahedral mesh discrete ordinates code Attila version 6.1.1 was used to calculate the photon kerma rate distribution in water around the Nucletron microSelectron mHDRv2 source. MCNPX 2.5.c was used to compute the Monte Carlo water photon kerma rate distribution. Two hundred million histories were simulated, resulting in standard errors of the mean of less than 3% overall. The number of energy groups, S{sub n} (angular order), P{sub n} (scattering order), and mesh elements were varied in addition to the method of analytic ray tracing to assess their effects on the deterministic solution. Water photon kerma rate matrices were exported from both codes into an in-house data analysis software. This software quantified the percent dose difference distribution, the number of points within {+-}3% and {+-}5%, and the mean percent difference between the two codes. The data demonstrated that a 5 energy-group cross-section set calculated results to within 0.5% of a 15 group cross-section set. S{sub 12} was sufficient to resolve the solution in angle. P{sub 2} expansion of the scattering cross-section was necessary to compute accurate distributions. A computational mesh with 55 064 tetrahedral elements in a 30 cm diameter phantom resolved the solution spatially. An efficiency factor of 110 with the above parameters was realized in comparison to MC methods. The Attila code provided an accurate and efficient solution of the Boltzmann transport equation for the mHDRv2 source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analytical study of twin-jet shielding two-dimensional model

The development of an analytical model to estimate the shielding of one jet by an adjacent jet in a twin jet configuration is discussed in relation to aircraft generated noise. The azimuthal redistribution of sound defining the shadow zone is investigated. Wave equations were solved in the plane normal to the jet axis to estimate the diffraction and reflection of sound by a heated, cylindrical jet. Thus, the noise source considered is essentially a line source assumed to emit at discrete frequency and at rest with respect to the shielding jet which is assumed to be a cylinder of heated flow in which the temperature is constant across the jet. Results show that the sound pressure decreases rapidly with frequency beyond the onset of the shielding to a minimum value. Results also show that increasing the spacing between the source and the jet shifts the curves toward higher frequencies.

Gerhold, C. H.↗

Initial Calibrations and Wind Tunnel Test Results for an In-Flow Reference Array Using New In-Flow Acoustic Sources in Four Array Mount Configurations

This paper describes efforts to develop a small in-flow phased microphone array as a reference acoustic sensor and quantify its level-measurement accuracy with new in-flow calibration sources. The devices can be applied to a wide variety of in- and out-of-flow measurement applications and test facilities. Recent tests of the array and two calibration sources in the NASA Anechoic Chamber and Army 7- by 10-foot Wind Tunnel at NASA Ames Research Center demonstrated that the array was functional over a frequency range of 2 to 100 kilohertz for emission angles of 92 degrees, 108 degrees, and 120 degrees, and Mach numbers of 0, 0.15, and 0.25. The array and calibration sources were then used to assess the relative effects of array installation on background noise and level measurement accuracy by locating the array in the flow (strut- and wall-mounted) as well as outside the flow behind a porous wall screen and a free shear layer. The wind tunnel array measurements were compared with anechoic chamber measurements using discrete microphones at the same source distance and emission angles. At 92 degrees, the noise floor and attenuation spectra were comparable (within 5 decibels) for each installation from 2 to 30 kilohertz. At higher angles, the array installation behind the Kevlar screen had the lowest noise floor at M = 0.15 and 0.25. The array installation 10 inches (maximum available distance) behind a free shear layer had higher background noise that is typically reduced to a lower level by moving the array back further from the flow. For emission angles greater than 92 degrees, both the Kevlar and free shear layer installations exhibited stronger attenuations in measured level, beginning at lower frequencies than either the wall- or strut-mount configurations. Additional array and calibration source units of the same design are being tested at NASA’s Glenn Research Center and Langley Research Center in their aeroacoustic research facilities in an effort to improve measurement accuracy and repeatability.

Aeroacoustic Wind Tunnel Research↗

Active Vibration Control for Helicopter Interior Noise Reduction Using Power Minimization

This report describes work performed by United Technologies Research Center (UTRC) for NASA Langley Research Center (LaRC) under Contract NNL11AA06C. The objective of this program is to develop technology to reduce helicopter interior noise resulting from multiple gear meshing frequencies. A novel active vibration control approach called Minimum Actuation Power (MAP) is developed. MAP is an optimal control strategy that minimizes the total input power into a structure by monitoring and varying the input power of controlling sources. MAP control was implemented without explicit knowledge of the phasing and magnitude of the excitation sources by driving the real part of the input power from the controlling sources to zero. It is shown that this occurs when the total mechanical input power from the excitation and controlling sources is a minimum. MAP theory is developed for multiple excitation sources with arbitrary relative phasing for single or multiple discrete frequencies and controlled by a single or multiple controlling sources. Simulations and experimental results demonstrate the feasibility of MAP for structural vibration reduction of a realistic rotorcraft interior structure. MAP control resulted in significant average global vibration reduction of a single frequency and multiple frequency excitations with one controlling actuator. Simulations also demonstrate the potential effectiveness of the observed vibration reductions on interior radiated noise.

Mendoza, J.↗

A Computational and Experimental Study of Resonators in Three Dimensions

In a previous work by the present authors, a computational and experimental investigation of the acoustic properties of two-dimensional slit resonators was carried out. The present paper reports the results of a study extending the previous work to three dimensions. This investigation has two basic objectives. The first is to validate the computed results from direct numerical simulations of the flow and acoustic fields of slit resonators in three dimensions by comparing with experimental measurements in a normal incidence impedance tube. The second objective is to study the flow physics of resonant liners responsible for sound wave dissipation. Extensive comparisons are provided between computed and measured acoustic liner properties with both discrete frequency and broadband sound sources. Good agreements are found over a wide range of frequencies and sound pressure levels. Direct numerical simulation confirms the previous finding in two dimensions that vortex shedding is the dominant dissipation mechanism at high sound pressure intensity. However, it is observed that the behavior of the shed vortices in three dimensions is quite different from those of two dimensions. In three dimensions, the shed vortices tend to evolve into ring (circular in plan form) vortices, even though the slit resonator opening from which the vortices are shed has an aspect ratio of 2.5. Under the excitation of discrete frequency sound, the shed vortices align themselves into two regularly spaced vortex trains moving away from the resonator opening in opposite directions. This is different from the chaotic shedding of vortices found in two-dimensional simulations. The effect of slit aspect ratio at a fixed porosity is briefly studied. For the range of liners considered in this investigation, it is found that the absorption coefficient of a liner increases when the open area of the single slit is subdivided into multiple, smaller slits.

Tam, C. K. W.↗

Final Report for ALCC Allocation: Predictive Simulation of Complex Flow in Wind Farms

This report documents work performed using ALCC computing resources granted under a proposal submitted in February 2016, with the resource allocation period spanning the period July 2016 through June 2017. The award allocation was 10.7 million processor-hours at the National Energy Research Scientific Computing Center. The simulations performed were in support of two projects: the Atmosphere to Electrons (A2e) project, supported by the DOE EERE office; and the Exascale Computing Project (ECP), supported by the DOE Office of Science. The project team for both efforts consists of staff scientists and postdocs from Sandia National Laboratories and the National Renewable Energy Laboratory. At the heart of these projects is the open-source computational-fluid-dynamics (CFD) code, Nalu. Nalu solves the low-Mach-number Navier-Stokes equations using an unstructured- grid discretization. Nalu leverages the open-source Trilinos solver library and the Sierra Toolkit (STK) for parallelization and I/O. This report documents baseline computational performance of the Nalu code on problems of direct relevance to the wind plant physics application - namely, Large Eddy Simulation (LES) of an atmospheric boundary layer (ABL) flow and wall-modeled LES of a flow past a static wind turbine rotor blade. Parallel performance of Nalu and its constituent solver routines residing in the Trilinos library has been assessed previously under various campaigns. However, both Nalu and Trilinos have been, and remain, in active development and resources have not been available previously to rigorously track code performance over time. With the initiation of the ECP, it is important to establish and document baseline code performance on the problems of interest. This will allow the project team to identify and target any deficiencies in performance, as well as highlight any performance bottlenecks as we exercise the code on a greater variety of platforms and at larger scales. The current study is rather modest in scale, examining performance on problem sizes of O(100 million) elements and core counts up to 8k cores. This will be expanded as more computational resources become available to the projects.

17 WIND ENERGY↗

Dust content of a hydrogen rich, low surface brightness galaxy and the luminosity history of 3C273

This project consists of a 30,000 second PSPC observation of the Giovanelli-Haynes Cloud in an attempt to detect light emitted by 3C273 which has been reflected by the cloud, and incidentally search the cloud for other sources of X-ray emission. The observation was carried out by ROSAT on Dec. 25, 1992 and the data was received by the P.I. in late March of 1993. We have examined the data and determined that the observation's background level, astrometry, etc. are acceptable. We have also detected diffuse emission from the direction of the Giovanelli-Haynes Cloud. Determination of the origin of this emission, by examining its morphology in relation to that of the radio map and the object's geometric relation with 3C273, requires software implementation of specialized algorithms. However, the most dramatic observation in the field is a potentially new population of discrete soft X-ray sources associated with dwarf galaxies.

Hamilton, Thomas T.↗

14-MeV Neutron Generator Used as a Thermal Neutron Source

One of the most important applications of the general purpose Monte Carlo N-Particle (MCNPS and MCNPX) codes is neutron shielding design. We employed this method to simulate the shield of a 14-MeV neutron generator used as a thermal neutron source providing an external thermal neutron beam for testing large area neutron detectors developed for diffraction studies in biology and also useful for national security applications. Nuclear reactors have been the main sources of neutrons used for scientific applications. In the past decade, however, a large number of reactors have been shut down, and the importance of other, smaller devices capable of providing neutrons for research has increased. At Brookhaven National Laboratory a moderated Am-Be neutron source with shielding is used for neutron detector testing. This source is relatively weak, but provides a constant flux of neutrons, even when not in use. The use of a 14 MeV energized neutron generator, with an order of magnitude higher neutron flux has been considered to replace the Am-Be source, but the higher fast neutron yield requires a more careful design of moderator and shielding. In the present paper we describe a proposed shielding configuration based on Monte Carlo calculations, and provide calculated neutron flux and dose distributions. We simulated the neutron flux distribution of our existing Am-Be source surrounded by a paraffin thermalizer cylinder (radius of 17.8 cm), 0.8 mm cadmium, and borated polyethylene as biological shield. The thermal neutrons are available through a large opening through the polyethylene and cadmium. The geometrical model for the MCNPS and MCNPX2 simulations is shown in Fig. 1. We simulated the Am-Be source neutron energy distribution as a point source having an energy distribution of four discrete lines at 3.0 (37%), 5.0 (35%), 8.0 (20%) and 11.0 (8%) MeV energies. The estimated source strength based on the original specifications is 6.6 {center_dot} 10{sup 6} neutrons/sec. The simulation accurately predicts the measured thermal neutron flux at the collimator (Figure 2), thus providing validation for this method. Using MCNPX we simulated the neutron and photon dose distribution and also obtained a good agreement with the measured values. Having established a validated framework for the shield calculation we then scaled up the Am-Be arrangement to simulate the shielding required for the higher neutron energy and flux of the neutron generator (-10{sup 8} neutrodsec at 14 MeV). Given the physical dimensions of the generator we have chosen a cylindrical geometry, where the generator tube is placed vertically into a cylindrical thermalizer (25 cm paraffin) from above. The thermalizer is surrounded by 0.8 mm cadmium, and a cylindrical borated polyethylene shield. A cylindrical opening (radius of 7.6 cm) serves to direct the neutrons out towards the experimental area (on the right side). The initial model is shown in figure 3. The first goal of the calculations was to establish the minimal required radius of the biological shield. For this purpose we performed MCNPX neutron and photon dose distribution calculations by tallying the absorbed dose on a 200 x 200 cm mesh in the vertical center plane superimposed over the geometry. Figure 4. displays the neutron dose distribution along the central horizontal (X) axis. As observed from the figure, a shielding radius of -80 cm is sufficient to obtain a dose level of < -4 mrem/hour outside the shield (except from the open neutron channel on the right). In the next step we studied the optimization of the thickness of the paraffin thermalizer by increasing the depth of the neutron exit channel into the paraffin cylinder. It was found, that the thermal flux greatly increases if we have thinner paraffin layer, an optimal value being about 5 cm thickness. But as a drawback the flux of fast neutrons also increased. A thicker thermalizer layer, in fact, acts as shielding. A slightly off centered, tangential placement of the neutron channel provides a solution which maximizes the thermal flux to fast neutron yield. Figure 5. and 6. display the final results, where we included an outside biological shield (20 cm thickness) providing a shielded experimental area. There is a 10-100 n/cm{sup 2}sec flux near the neutron beam exit, and outside the shield the neutron dose is below the radiation area limit (-5 mrem/hour).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A comparison of HDR near source dosimetry using a treatment planning system, Monte Carlo simulation, and radiochromic film

This study aimed to investigate the high-dose rate Iridium-192 brachytherapy, including near source dosimetry, of a catheter-based applicator from 0.5 mm to 1 cm along the transverse axis. Radiochromic film and Monte Carlo (MC) simulation were used to generate absolute dose for the catheter-based applicator. Results from radiochromic film and MC simulation were compared directly to the treatment planning system (TPS) based on the American Association of Physicists in Medicine Updated Task Group 43 (TG-43U1) dose calculation formalism. The difference between dose measured using radiochromic film along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 24%±13%. The dose difference between the MC simulation along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 22.1%±3%. For distances from 1.5 mm to 1 cm from the surface, radiochromic film and MC simulation agreed with TPS within an uncertainty of 3%. The TPS under-predicts the dose at the surface of the applicator, i.e., 0.5 mm from the catheter surface, as compared to the measured and MC simulation predicted dose. MC simulation results demonstrated that 15% of this error is due to neglecting the beta particles and discrete electrons emanating from the sources and not considered by the TPS, and 7% of the difference was due to the photon alone, potentially due to the differences in MC dose modeling, photon spectrum, scoring techniques, and effect of the presence of the catheter and the air gap. Beyond 1 mm from the surface, the TPS dose algorithm agrees with the experimental and MC data within 3%.

61 RADIATION PROTECTION AND DOSIMETRY↗

TIME-DEPENDENT MULTI-GROUP MULTI-DIMENSIONAL RELATIVISTIC RADIATIVE TRANSFER CODE BASED ON SPHERICAL HARMONIC DISCRETE ORDINATE METHOD

We develop a time-dependent, multi-group, multi-dimensional relativistic radiative transfer code, which is required to numerically investigate radiation from relativistic fluids that are involved in, e.g., gamma-ray bursts and active galactic nuclei. The code is based on the spherical harmonic discrete ordinate method (SHDOM) which evaluates a source function including anisotropic scattering in spherical harmonics and implicitly solves the static radiative transfer equation with ray tracing in discrete ordinates. We implement treatments of time dependence, multi-frequency bins, Lorentz transformation, and elastic Thomson and inelastic Compton scattering to the publicly available SHDOM code. Our code adopts a mixed-frame approach; the source function is evaluated in the comoving frame, whereas the radiative transfer equation is solved in the laboratory frame. This implementation is validated using various test problems and comparisons with the results from a relativistic Monte Carlo code. These validations confirm that the code correctly calculates the intensity and its evolution in the computational domain. The code enables us to obtain an Eddington tensor that relates the first and third moments of intensity (energy density and radiation pressure) and is frequently used as a closure relation in radiation hydrodynamics calculations.

79 ASTRONOMY AND ASTROPHYSICS↗

The estimation of absorbed dose rates for non-human biota : an extended inter-comparison.

An exercise to compare 10 approaches for the calculation of unweighted whole-body absorbed dose rates was conducted for 74 radionuclides and five of the ICRP's Reference Animals and Plants, or RAPs (duck, frog, flatfish egg, rat and elongated earthworm), selected for this exercise to cover a range of body sizes, dimensions and exposure scenarios. Results were analysed using a non-parametric method requiring no specific hypotheses about the statistical distribution of data. The obtained unweighted absorbed dose rates for internal exposure compare well between the different approaches, with 70% of the results falling within a range of variation of {+-}20%. The variation is greater for external exposure, although 90% of the estimates are within an order of magnitude of one another. There are some discernible patterns where specific models over- or under-predicted. These are explained based on the methodological differences including number of daughter products included in the calculation of dose rate for a parent nuclide; source-target geometry; databases for discrete energy and yield of radionuclides; rounding errors in integration algorithms; and intrinsic differences in calculation methods. For certain radionuclides, these factors combine to generate systematic variations between approaches. Overall, the technique chosen to interpret the data enabled methodological differences in dosimetry calculations to be quantified and compared, allowing the identification of common issues between different approaches and providing greater assurance on the fundamental dose conversion coefficient approaches used in available models for assessing radiological effects to biota.

59 BASIC BIOLOGICAL SCIENCES↗

A multilevel Cartesian non-uniform grid time domain algorithm

A multilevel Cartesian non-uniform grid time domain algorithm (CNGTDA) is introduced to rapidly compute transient wave fields radiated by time dependent three-dimensional source constellations. CNGTDA leverages the observation that transient wave fields generated by temporally bandlimited and spatially confined source constellations can be recovered via interpolation from appropriately delay- and amplitude-compensated field samples. This property is used in conjunction with a multilevel scheme, in which the computational domain is hierarchically decomposed into subdomains with sparse non-uniform grids used to obtain the fields. For both surface and volumetric source distributions, the computational cost of CNGTDA to compute the transient field at N{sub s} observation locations from N{sub s} collocated sources for N{sub t} discrete time instances scales as O(N{sub t}N{sub s}logN{sub s}) and O(N{sub t}N{sub s}log{sup 2}N{sub s}) in the low- and high-frequency regimes, respectively. Coupled with marching-on-in-time (MOT) time domain integral equations, CNGTDA can facilitate efficient analysis of large scale time domain electromagnetic and acoustic problems.

97 MATHEMATICS AND COMPUTING↗

CIRCULAR POLARIZATION IN PULSARS DUE TO CURVATURE RADIATION

The beamed radio emission from relativistic plasma (particles or bunches), constrained to move along the curved trajectories, occurs in the direction of velocity. We have generalized the coherent curvature radiation model to include the detailed geometry of the emission region in pulsar magnetosphere and deduced the polarization state in terms of Stokes parameters. By considering both the uniform and modulated emissions, we have simulated a few typical pulse profiles. The antisymmetric type of circular polarization survives only when there is modulation or discrete distribution in the emitting sources. Our model predicts a correlation between the polarization angle swing and sign reversal of circular polarization as a geometric property of the emission process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exploitation of Geometric Occlusion and Covariance Spectroscopy in a Gamma Sensor Array

The National Security Technologies, LLC, Remote Sensing Laboratory has recently used an array of six small-footprint (1-inch diameter by 3-inch long) cylindrical crystals of thallium-doped sodium iodide scintillators to obtain angular information from discrete gamma ray–emitting point sources. Obtaining angular information in a near-field measurement for a field-deployed gamma sensor is a requirement for radiological emergency work. Three of the sensors sit at the vertices of a 2-inch isosceles triangle, while the other three sit on the circumference of a 3-inch-radius circle centered in this triangle. This configuration exploits occlusion of sensors, correlation from Compton scattering within a detector array, and covariance spectroscopy, a spectral coincidence technique. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. By evaluating the values of, and the uncertainties in, the photopeak areas, efficiencies, branching ratio, peak area correction factors, and the correlations between these quantities, one can determine the precise activity of a particular radioisotope from a mixture of radioisotopes that have overlapping photopeaks that are ordinarily hard to deconvolve. The spectral coincidence technique, often known as covariance spectroscopy, examines the correlations and fluctuations in data that contain valuable information about radiation sources, transport media, and detection systems. Covariance spectroscopy enhances radionuclide identification techniques, provides directional information, and makes weaker gamma-ray emission—normally undetectable by common spectroscopic analysis—detectable. A series of experimental results using the concept of covariance spectroscopy are presented.

occlusion, covariance spectroscopy, correlations, ↗

Large-scale 3D geoelectromagnetic modeling using parallel adaptive high-order finite element method

Here, we have investigated the use of the adaptive high-order finite-element method (FEM) for geoelectromagnetic modeling. Because high-order FEM is challenging from the numerical and computational points of view, most published finite-element studies in geoelectromagnetics use the lowest order formulation. Solution of the resulting large system of linear equations poses the main practical challenge. We have developed a fully parallel and distributed robust and scalable linear solver based on the optimal block-diagonal and auxiliary space preconditioners. The solver was found to be efficient for high finite element orders, unstructured and nonconforming locally refined meshes, a wide range of frequencies, large conductivity contrasts, and number of degrees of freedom (DoFs). Furthermore, the presented linear solver is in essence algebraic; i.e., it acts on the matrix-vector level and thus requires no information about the discretization, boundary conditions, or physical source used, making it readily efficient for a wide range of electromagnetic modeling problems. To get accurate solutions at reduced computational cost, we have also implemented goal-oriented adaptive mesh refinement. The numerical tests indicated that if highly accurate modeling results were required, the high-order FEM in combination with the goal-oriented local mesh refinement required less computational time and DoFs than the lowest order adaptive FEM.

58 GEOSCIENCES↗

Bent crystal spectrometer for solar X-ray spectroscopy

A bent crystal spectrometer employs a collimated beam of X-rays incident on the crystal over a range of Bragg angles determined by the orientation and curvature of the crystal surface. It provides continuous and simultaneous coverage of all X-ray wavelengths within its spectral range. In-flight testing for solar X-ray spectroscopy was performed using a small instrument to supplement the wavelength coverage of several scanning spectrometers used to study solar active regions in the 9-24 A range. Later testing included modifications to alleviate problems caused by ultraviolet radiation. Future usage of the device will include studies of time variable emission from solar flares or discrete galactic X-ray sources, and the first major experiment to utilize bent crystal spectrometers will be the Solar Maximum Mission satellite in 1979.

Rapley, C. G.↗