Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diamond”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Radiation attenuation by single-crystal diamond windows

As artificial diamond becomes more cost effective it is likely to see increasing use as a window for sample environment equipment used in diffraction experiments. Such windows are particularly useful as they exhibit exceptional mechanical properties in addition to being highly transparent to both X-ray and neutron radiation. A key application is in high-pressure studies, where diamond anvil cells (DACs) are used to access extreme sample conditions. However, despite their utility, an important consideration when using single-crystal diamond windows is their interaction with the incident beam. In particular, the Bragg condition will be satisfied for specific angles and wavelengths, leading to the appearance of diamond Bragg spots on the diffraction detectors but also, unavoidably, to loss of transmitted intensity of the beam that interacts with the sample. This effect can be particularly significant for energy-dispersive measurements, for example, in time-of-flight neutron diffraction work using DACs. Furthermore, this article presents a semi-empirical approach that can be used to correct for this effect, which is a prerequisite for the accurate determination of diffraction intensities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A synthetic diamond diode in volumetric modulated arc therapy dosimetry

Purpose: The aim of this work is to investigate the behavior of a single crystal diamond diode (SCDD) for volumetric modulated arc therapy (VMAT) dose verifications. This delivery technique is one of the most severe test of a dosimeter performance due to the modulation of the dose rate achieved by simultaneously changing the velocity of the gantry and the position of the collimator leaves. The performed measurements with VMAT photon beams can therefore contribute to an overall global validation of the device to be used in dose distribution verifications.Methods: The SCDD response to 6 MVRX has been tested and compared with reference ionization chambers and treatment planning system (TPS) calculations in different experiments: (a) measurements of output factors for small field sizes (square fields of side ranging between 8 mm and 104 mm) by SCDD and A1SL ionization chamber; (b) angular dependence evaluation of the entire experimental set-up by SCDD, A1SL, and Farmer ionization chambers; and (c) acquisition of dose profiles for a VMAT treatment of a pulmonary disease in latero-lateral and gantry-target directions by SCDD and A1SL ionization chamber.Results: The output factors measured by SCDD favorably compare with the ones obtained by A1SL, whose response is affected by the lack of charged particle equilibrium and by averaging effect when small fields are involved. From the experiment on angular dependence, a good agreement is observed among the diamond diode, the ion chambers, and the TPS. In VMAT profiles, the absorbed doses measured by SCDD and A1SL compare well with the TPS calculated ones. An overall better agreement is observed in the case of the diamond dosimeter, which is also showing a better accuracy in terms of distance to agreement in the high gradient regions.Conclusions: Synthetic diamond diodes, whose performance were previously studied for conformal and IMRT radiotherapy techniques, were found to be suitable detectors also for dosimetric measurements in volumetric arc therapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-232: Micro Diamonds - Determination of Their Lateral Response Function Via Gap-Beam Dose Profiles

Purpose: The aim of this study is the measurement of the lateral response function of microDiamonds by comparison with radiochromic film dose measurement. In this study a TM60019 microDiamond (PTW Freiburg, Germany) and a prototype synthetic diamond detector with smaller sensitive volume were investigated. Methods: Two lead blocks were positioned below the gantry head of an Elekta Synergy accelerator using a gantry mount. Between the blocks two sheets of paper were fixed. The water phantom was positioned below the gantry mount, so that the block to water distance was 20 cm. The gap beam profile was measured at 5 cm water depth by radiochromic EBT3 film and diamond detectors. The film was fixed on a RW3 plate, moved by the step motor system of the phantom and digitized by an Epson 10000XL scanner using the red color channel. Results: The lateral response of the prototype diamond detector is comparable to that of film measurements, i.e. has negligible width. This corresponds to the small detector volume of the prototype detector. In contrast to this the FWHM values of the gap-beam dose profiles measured with the TM60019 detector are somewhat larger, which corresponds to the larger sensitive detector volume. Conclusion: This study has illustrated the high spatial resolution of the diamond detectors. In comparison with filmmeasured narrow-beam dose profiles, the TM60019 has a spatial resolution function of about 2 mm FWHM, whereas the FWHM for the prototype is practically negligible. However due to the low signal caused by the small sensitive volume, measurements with the prototype in clinical routine are a challenge. On the other hand the TM60019 is a good compromise between detector volume and signal output and thus a well suited detector for most clinically relevant small field situations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x-ray fields

Purpose: Modern radiotherapy modalities often use small or nonstandard fields to ensure highly localized and precise dose delivery, challenging conventional clinical dosimetry protocols. The emergence of preclinical spatially fractionated synchrotron radiotherapies with high dose-rate, sub-millimetric parallel kilovoltage x-ray beams, has pushed clinical dosimetry to its limit. A commercially available synthetic single crystal diamond detector designed for small field dosimetry has been characterized to assess its potential as a dosimeter for synchrotron microbeam and minibeam radiotherapy. Methods: Experiments were carried out using a synthetic diamond detector on the imaging and medical beamline (IMBL) at the Australian Synchrotron. The energy dependence of the detector was characterized by cross-referencing with a calibrated ionization chamber in monoenergetic beams in the energy range 30–120 keV. The dose-rate dependence was measured in the range 1–700 Gy/s. Dosimetric quantities were measured in filtered white beams, with a weighted mean energy of 95 keV, in broadbeam and spatially fractionated geometries, and compared to reference dosimeters. Results: The detector exhibits an energy dependence; however, beam quality correction factors (k{sub Q}) have been measured for energies in the range 30–120 keV. The k{sub Q} factor for the weighted mean energy of the IMBL radiotherapy spectrum, 95 keV, is 1.05 ± 0.09. The detector response is independent of dose-rate in the range 1–700 Gy/s. The percentage depth dose curves measured by the diamond detector were compared to ionization chambers and agreed to within 2%. Profile measurements of microbeam and minibeam arrays were performed. The beams are well resolved and the full width at halfmaximum agrees with the nominal width of the beams. The peak to valley dose ratio (PVDR) calculated from the profiles at various depths in water agrees within experimental error with PVDR calculations from Gafchromic film data. Conclusions: The synthetic diamond detector is now well characterized and will be used to develop an experimental dosimetry protocol for spatially fractionated synchrotron radiotherapy.

60 APPLIED LIFE SCIENCES↗

Orientation-independent room temperature optical 13 C hyperpolarization in powdered diamond

Dynamic nuclear polarization via contact with electronic spins has emerged as an attractive route to enhance the sensitivity of nuclear magnetic resonance beyond the traditional limits imposed by magnetic field strength and temperature. Among the various alternative implementations, the use of nitrogen vacancy (NV) centers in diamond—a paramagnetic point defect whose spin can be optically polarized at room temperature—has attracted widespread attention, but applications have been hampered by the need to align the NV axis with the external magnetic field. We overcome this hurdle through the combined use of continuous optical illumination and a microwave sweep over a broad frequency range. As a proof of principle, we demonstrate our approach using powdered diamond with which we attain bulk 13 C spin polarization in excess of 0.25% under ambient conditions. Remarkably, our technique acts efficiently on diamond crystals of all orientations and polarizes nuclear spins with a sign that depends exclusively on the direction of the microwave sweep. Our work paves the way toward the use of hyperpolarized diamond particles as imaging contrast agents for biosensing and, ultimately, for the hyperpolarization of nuclear spins in arbitrary liquids brought in contact with their surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diamond family of nanoparticle superlattices

Diamond lattices formed by atomic or colloidal elements exhibit remarkable functional properties. However, building such structures via self-assembly has proven to be challenging because of the low packing fraction, sensitivity to bond orientation, and local heterogeneity. We report a strategy for creating a diamond superlattice of nano-objects via self-assembly and demonstrate its experimental realization by assembling two variant diamond lattices, one with and one without atomic analogs. Our approach relies on the association between anisotropic particles with well-defined tetravalent binding topology and isotropic particles. The constrained packing of triangular binding footprints of truncated tetrahedra on a sphere defines a unique three-dimensional lattice. Hence, the diamond self-assembly problem is solved via its mapping onto two-dimensional triangular packing on the surface of isotropic spherical particles.

36 MATERIALS SCIENCE↗

Adjoint-optimized nanoscale light extractor for nitrogen-vacancy centers in diamond

Abstract We designed a nanoscale light extractor (NLE) for the efficient outcoupling and beaming of broadband light emitted by shallow, negatively charged nitrogen-vacancy (NV) centers in bulk diamond. The NLE consists of a patterned silicon layer on diamond and requires no etching of the diamond surface. Our design process is based on adjoint optimization using broadband time-domain simulations and yields structures that are inherently robust to positioning and fabrication errors. Our NLE functions like a transmission antenna for the NV center, enhancing the optical power extracted from an NV center positioned 10 nm below the diamond surface by a factor of more than 35, and beaming the light into a ±30° cone in the far field. This approach to light extraction can be readily adapted to other solid-state color centers.

42 ENGINEERING↗

Study of Electron Transport and Amplification in Diamond

As a successful completion of this award, my group has demonstrated world-leading electron gain from diamond for use in a diamond-amplified photocathode. Also, using high-resolution photoemission measurements we were able to uncover exciting new physics of the electron emission mechanisms from hydrogen terminated diamond. Our work, through the continued support of HEP, has resulted in a greater understanding of the diamond material science, including current limits, charge transport modeling, and spatial uniformity.

36 MATERIALS SCIENCE↗

Final Report: Next Generation Diamond Drumhead X-Ray Optics

Problem / Opportunity Statement: Future high-impact scientific applications at synchrotron and Free-Electron Laser (FEL) X-ray sources require the development of processing and mounting methods for ultra-thin diamond crystals to meet the most challenging needs of pioneering research at next generation light source facilities. These methods should be capable of manufacturing crystal plates as thin as 10 micrometers over an area of a few mm2, and with a surface cut in different crystal orientations, such as the diamond {100}, {111}, {110} and {113} planes. Project Purpose and Approach: In Phase I, Great Lakes Crystal Technologies (GLCT) partnered with Stonybrook University (SUNY) to created thin diamond drumhead crystals. The purpose of the Phase I project is to transfer the drumhead membrane window etching technology from SUNY to GLCT. Testing of a device using the beamline at Stanford Linear Accelerator Laboratory was initially planned, however, a delay on the part of a third party service provided required us to get beamline testing done at Argonne National Laboratory. Phase I Taskwork: Testing of a high purity diamond plate thinning and etching process was performed. By SUNY and GLCT. Plates were sent to a third party service provider for thinning to ~100 microns, however, delays required that GLCT develop an in-house thinning process to complete the taskwork. GLCT successfully developed this in-house capability even though it was initially planned to be part of the Phase II Taskwork. Multiple practice and deliverable plates were provided to SUNY to be etched into the target drumhead devices. GLCT practiced and refined an in-house plate thinning process and produced five plates with thicknesses in the 60 – 150 micron range. Processing of the plates has begun and will continue in a no-cost extension period necessitated by the third party service provider delay. GLCT also procured and installed a reactive ion etching/inductively coupled plasma system. In addition, one of the thinned plates was measured at the Applied Photon Source at APL for a pre-processing assessment of the crystalline strain. After processing the plate into a drumhead and annealing, a post-processing assessment of the strain will be performed. Phase I Results: The initial data from GLCT’s plate thinning process development, SUNY’s drumhead etching processing, and characterization at APS/ANL demonstrate our teams capabilities to achieve the project goals. Commercial Applications & Benefits: The proposed technology will benefit advanced x-ray science performed at BNL and the 70+ additional advanced beamlines around the world. There are also a number of medical and homeland security applications which could benefit from the technology.

Quayle, Paul↗

Ion-beam-assisted etching of diamond

The high thermal conductivity, low RF loss, and inertness of diamond make it useful in traveling wave tubes operating in excess of 500 GHz. Such use requires the controlled etching of type IIA diamond to produce grating like structures tens of micrometers deep. Previous work on reactive ion etching with O2 gave etching rates on the order of 20 nm/min and poor etch selectivity between the masking material (Ni or Cr) and the diamond. An alternative approach which uses a Xe(+) beam and a reactive gas flux of NO2 in an ion-beam-assisted etching system is reported. An etching rate of 200 nm/min was obtained with an etching rate ratio of 20 between the diamond and an aluminum mask.

Efremow, N. N.↗

Wave-front correctors by diamond turning

The production of wave-front correctors by single-point diamond turning is reported. Interferograms are shown which demonstrate excellent agreement between the diamond-turned surface and the desired surface. It is concluded from this experiment that it is now feasible by means of single-point diamond turning to make generalized wave-front control surfaces or to produce any unusual surface desired by the optical designer. The maximum departure from the nearest regular surface is set by the dynamic range and maximum diamond point acceleration permitted by the machine.

Meinel, A. B.↗

Dual-ion-beam deposition of carbon films with diamond-like properties

A single and dual ion beam system was used to generate amorphous carbon films with diamond like properties. A methane/argon mixture at a molar ratio of 0.28 was ionized in the low pressure discharge chamber of a 30-cm-diameter ion source. A second ion source, 8 cm in diameter was used to direct a beam of 600 eV Argon ions on the substrates (fused silica or silicon) while the deposition from the 30-cm ion source was taking place. Nuclear reaction and combustion analysis indicate H/C ratios for the films to be 1.00. This high value of H/C, it is felt, allowed the films to have good transmittance. The films were impervious to reagents which dissolve graphitic and polymeric carbon structures. Although the measured density of the films was approximately 1.8 gm/cu cm, a value lower than diamond, the films exhibited other properties that were relatively close to diamond. These films were compared with diamond like films generated by sputtering a graphite target.

Mirtich, M. J.↗

Shock processing of interstellar dust - Diamonds in the sky

The processing of interstellar dust grains by strong shock waves is studied, with the emphasis on the effects of grain-grain collisions. Such collisions provide the high pressures required to transform interstellar graphite and amorphous carbon grains into diamonds. Diamond metamorphism is as important for the destruction of such grains as vaporization and sputtering. It is calculated that about 5 percent of the C is expected to be in the form of 5-100 A diamonds in the interstellar medium. These results support the suggested interstellar origin for the recently discovered small meteoritic diamonds by providing a feasible interstellar formation mechanism.

Tielens, A. G. G. M.↗

Diamond like carbon coatings: Categorization by atomic number density

Dense diamond-like hydrocarbon films grown at the NASA Lewis Research Center by radio frequency self bias discharge and by direct ion beam deposition were studied. A new method for categorizing hydrocarbons based on their atomic number density and elemental composition was developed and applied to the diamond-like hydrocarbon films. It was shown that the diamond-like hydrocarbon films are an entirely new class of hydrocarbons with atomic number densities lying between those of single crystal diamond and adamantanes. In addition, a major review article on these new materials was completed in cooperation with NASA Lewis Research Center personnel.

Angus, John C.↗

Noble gases in diamonds - Occurrences of solarlike helium and neon

Seventeen diamond samples from diverse locations were analyzed for the contents of He, Ar, Kr, and Xe, and of their isotopes, using a Reynolds (1956) type glass mass spectrometer. The results disclosed a large spread in the He-3/He-4 ratios, ranging from values below atmospheric to close to the solar ratio. In particular, solarlike He-3/He-4 ratios were seen for an Australian colorless diamond composite and an Arkansas diamond, which also displayed solarlike neon isotopic ratios. Wide variation was also observed in the He-4/Ar-40 ratios, suggesting a complex history for the source regions and the diamond crystallization processes.

Honda, M.↗

On diamond, graphitic and amorphous carbons in primitive extraterrestrial solar system materials

Carbon is among the most abundant elements in the universe and carbon chemistry in meteorites and comets is an important key to understanding many Solar System and interstellar processes. Yet, the mineralogical properties and interrelations between various structural forms of elemental carbon remain ambiguous. Crystalline elemental carbons include rhombohedral graphite, hexagonal graphite, cubic diamond, hexagonal diamond (i.e., lonsdaleite or carbon-2H) and chaoite. Elemental carbon also occurs as amorphous carbon and poorly graphitized (or turbostratic) carbon but of all the forms of elemental carbon only graphite is stable under physical conditions that prevail in small Solar System bodies and in the interstellar medium. The recent discovery of cubic diamond in carbonaceous chondrites and hexagonal diamond in chondritic interplanetary dust particles (IDPs) have created a renewed interest in the crystalline elemental carbons that were not formed by shock processes on a parent body. Another technique, Raman spectroscopy, confirms a widespread occurrence of disordered graphite in the Allende carbonaceous chondrite and in chondritic IDPs. Elemental carbons have also been identified by their characteristic K-edge features in electron energy loss spectra (EELS). However, the spectroscopic data do not necessarily coincide with those obtained by selected area electron diffraction (SAED). In order to interpret these data in terms of rational crystalline structures, it may be useful to consider the principles underlying electron diffraction and spectroscopic analyses. Electron diffraction depends on electron scattering, on the type of atom and the distance between atoms in a crystal lattice. Spectroscopic data are a function of the type of atom and the energy of bonds between atoms. Also, SAED is a bulk sampling technique when compared to techniques such as Raman spectroscopy or EELS. Thus, it appears that combined analyses provide contradictory results and that amorphous, or short-range ordered, carbon identified by conventional TEM imaging and SAED may show evidence for sp(3) bonds in EELS spectra. It is suggested that complex, nanometer-scale, mineralogical interrelations are common to all elemental carbons irrespective of their origin. The subsequent thermal history, or energy balance, will determine the ultimate microstructure.

Rietmeijer, Frans J. M.↗

Thermal diffusivity of diamond films

A laser pulse technique to measure the thermal diffusivity of diamond films deposited on a silicon substrate is developed. The effective thermal diffusivity of diamond film on silicon was measured by observing the phase and amplitude of the cyclic thermal waves generated by the laser pulses. An analytical model is developed to calculate the effective in-plane (face-parallel) diffusivity of a two layer system. The model is used to reduce the effective thermal diffusivity of the diamond/silicon sample to a value for the thermal diffusivity and conductivity of the diamond film. Phase and amplitude measurements give similar results. The thermal conductivity of the films is found to be better than that of type 1a natural diamond.

Albin, Sacharia↗

Extreme ultraviolet transmission of a synthetic diamond thin film

Measurements are presented of a thin film of synthetic diamond at various wavelengths in the extreme ultraviolet. The synthetic diamond combines the transmission properties of carbon with the strength, density, and ruggedness of a natural diamond. The Extreme Ultraviolet Transmission (EUV) of a film of the synthetic diamond has shown the existence of a thin surface layer of silicon, probably in the form of silicon carbide, which is not a contaminant layer.

Vallerga, John V.↗