Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector grounding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Vibration Isolation System for Cryocoolers of Soft X-Ray Spectrometer (SXS) Onboard ASTRO-H (Hitomi)

Soft X-ray Spectrometer (SXS) onboard ASTRO-H (named Hitomi after launch) is a micro-calorimeter-type spectrometer, installed in a dewar to be cooled at 50 mK. The energy resolution of the SXS engineering model suffered from micro-vibration from cryocoolers mounted on the dewar. This is mitigated for the flight model by introducing vibration isolation systems between the cryocoolers and the dewar. The detector performance of the flight model was verified before launch of the spacecraft in both ambient condition and thermal-vac condition, showing no detectable degradation in energy resolution. The in-orbit performance was also consistent with that on ground, indicating that the cryocoolers were not damaged by launch environment. The design and performance of the vibration isolation system along with the mechanism of how the micro-vibration could degrade the cryogenic detector is shown.

Microcalorimeter↗

Fiber-Optic Bragg Gratings and Optical Holography Compared as Vibration Detectors

The NASA Glenn Research Center is interested in determining structural damage in engine components during flight to evaluate the health of aerospace propulsion systems. On the ground, we can use holography to detect structural damage by examining the characteristic mode shapes and frequencies of vibrating objects. We are studying the feasibility of using embedded fiber Bragg gratings (FBGs) to accomplish this goal in a flight-worthy system, by using the minimal intrusion and high sensitivity afforded by fiber optics. We have recently compared holographically imaged modes of vibrating plates with the corresponding dynamic strains detected by embedded FBGs. We constructed an experimental setup for studying the responses of FBGs to dynamic excitations. One of the plates was made of a polymer matrix composite (PMC) with an FBG embedded in it, and the other one was made of copper with surface-mounted FBGs. The instrumented plates were mounted and vibrated, and time-averaged holography was used to measure their surface displacements. Simultaneously, the signals from the FBGs were detected and sent via fiber-optic cable to a quiet location about 20 m away for interrogation. The the test configuration used for the PMC plate is shown. Experimental results are also shown. The FBG was embedded in the middle of the PMC plates, roughly within the center circular fringe in each of the interferograms shown. Two resonant excitation frequencies were used: 706 and 3062 Hz. The plot in this paper shows a larger FBG signal at the higher frequency; this is because the plate bends more at higher order resonant modes, causing higher strain. This contrasts to the smaller displacements characteristic of higher frequencies, which are measured by holographic techniques.

Adamovsky, Grigory↗

Gamma-ray burst and spectroscopy instrumentation development at the Goddard Space Flight Center

This paper summarizes the activities that are specifically related to the development of instrumentation for gamma-ray astronomy. Three programs are described: (1) the Gamma-Ray Imaging Spectrometer (GRIS), a balloon-borne array of seven germanium detectors for high-resolution spectrographic studies of persistent gamma-ray sources; (2) the Transient Gamma-Ray Spectrometer (TGRS), a single radiatively-cooled germanium detector for the spectrographic study of gamma-ray bursts, and (3) the Rapidly Moving Telescope (RMT), a ground-based optical telescope for the detection and study of short-lived optical transients, particularly those that occur in coincidence with gamma-ray bursts.

Teegarden, B. J.↗

Intelligent neuroprocessors for in-situ launch vehicle propulsion systems health management

Efficacy of existing on-board propulsion systems health management systems (HMS) are severely impacted by computational limitations (e.g., low sampling rates); paradigmatic limitations (e.g., low-fidelity logic/parameter redlining only, false alarms due to noisy/corrupted sensor signatures, preprogrammed diagnostics only); and telemetry bandwidth limitations on space/ground interactions. Ultra-compact/light, adaptive neural networks with massively parallel, asynchronous, fast reconfigurable and fault-tolerant information processing properties have already demonstrated significant potential for inflight diagnostic analyses and resource allocation with reduced ground dependence. In particular, they can automatically exploit correlation effects across multiple sensor streams (plume analyzer, flow meters, vibration detectors, etc.) so as to detect anomaly signatures that cannot be determined from the exploitation of single sensor. Furthermore, neural networks have already demonstrated the potential for impacting real-time fault recovery in vehicle subsystems by adaptively regulating combustion mixture/power subsystems and optimizing resource utilization under degraded conditions. A class of high-performance neuroprocessors, developed at JPL, that have demonstrated potential for next-generation HMS for a family of space transportation vehicles envisioned for the next few decades, including HLLV, NLS, and space shuttle is presented. Of fundamental interest are intelligent neuroprocessors for real-time plume analysis, optimizing combustion mixture-ratio, and feedback to hydraulic, pneumatic control systems. This class includes concurrently asynchronous reprogrammable, nonvolatile, analog neural processors with high speed, high bandwidth electronic/optical I/O interfaced, with special emphasis on NASA's unique requirements in terms of performance, reliability, ultra-high density ultra-compactness, ultra-light weight devices, radiation hardened devices, power stringency, and long life terms.

Gulati, S.↗

Cryogenic measurements of aerojet GaAs n-JFETs

The spectral noise characteristics of Aerojet GaAs n-JFETs have been investigated down to liquid helium temperatures. Voltage noise characterization was performed with the FET in 1) the floating gate mode, 2) the grounded gate mode to determine the lowest noise readings possible and 3) with an extrinsic silicon photodetector at various detector bias voltages, to determine optimum operating conditions. Current noise characterization was measured at the drain in the temperature range 300 to 77 K. Device design and MBE processing are described. Static I-V characterization is done at 300, 77 and 6 K. The measurements indicate that the Aerojet GaAs n-JFET is a quiet and stable device at liquid helium temperatures. Hence, it can be considered as a readout line driver or infrared detector preamplifier as well as a host of other cryogenic applications. Its noise performance is superior to that of Si MOSFETs operating at liquid helium temperatures, and is equal to the best Si n-JFETs operating at 300 K.

Goebel, John H.↗

The NASA - Arc 10/20 micron camera

A new infrared camera (AIR Camera) has been developed at NASA - Ames Research Center for observations from ground-based telescopes. The heart of the camera is a Hughes 58 x 62 pixel Arsenic-doped Silicon detector array that has the spectral sensitivity range to allow observations in both the 10 and 20 micron atmospheric windows.

Roellig, T. L.↗

Strategies for Studying the Sources of Gamma Ray Bursts

The study of gamma ray bursts (GRBs) has rapidly evolved in recent years with the discovery of their cosmological nature and with BATSE, BeppoSAX, HETE and the IPN enabling a wide variety of associated . afterglow measurements. Multiwavelength observations ranging through the radio, optical, soft and hard x-ray, and gamma-ray regimes have exploded the field of GRB interpretation. Also, the Amanda, Milagro and LIGO experiments can search for related neutrino, cosmic-ray photon, and gravitational radiation events, even with the delayed alerts, such as from the IPN. The infrared region, where the optical emissions from sources at the extreme distances may be shifted, will become important but is undersubscribed. The soon-to-be launched Swift mission will greatly broaden the GRB discipline, and a strategy for associated ground-based measurements is outlined. The need for the improved global distribution of all instruments, in particular, robotic infrared detectors, is cited.

Cline, T. L.↗

Low Noise Camera for Suborbital Science Applications

Low-cost, commercial-off-the-shelf- (COTS-) based science cameras are intended for lab use only and are not suitable for flight deployment as they are difficult to ruggedize and repackage into instruments. Also, COTS implementation may not be suitable since mission science objectives are tied to specific measurement requirements, and often require performance beyond that required by the commercial market. Custom camera development for each application is cost prohibitive for the International Space Station (ISS) or midrange science payloads due to nonrecurring expenses (~$2,000 K) for ground-up camera electronics design. While each new science mission has a different suite of requirements for camera performance (detector noise, speed of image acquisition, charge-coupled device (CCD) size, operation temperature, packaging, etc.), the analog-to-digital conversion, power supply, and communications can be standardized to accommodate many different applications. The low noise camera for suborbital applications is a rugged standard camera platform that can accommodate a range of detector types and science requirements for use in inexpensive to mid range payloads supporting Earth science, solar physics, robotic vision, or astronomy experiments. Cameras developed on this platform have demonstrated the performance found in custom flight cameras at a price per camera more than an order of magnitude lower.

Hyde, David↗

Development and Performance of a Suprathermal Electron Spectrometer to Study Auroral Precipitations

The design, development, and performance of Medium-energy Electron SPectrometer (MESP), dedicated to the in situ observation of suprathermal electrons in the auroral ionosphere, are summarized in this paper. MESP employs a permanent magnet filter with a light tight structure to select electrons with proper energies guided to the detectors. A combination of two avalanche photodiodes and a large area solid-state detector (SSD) provided 46 total energy bins (1 keV resolution for 3-20 keV range for APDs, and 7 keV resolution for greater than 20 keV range for SSDs). Multi-channel ultra-low power application-specific integrated circuits are also verified for the flight operation to read-out and analyze the detector signals. MESP was launched from Poker F1at Research Range on 3 March 2014 as a part of ground-to-rocket electrodynamics-electrons correlative experiment (GREECE) mission. MESP successfully measured the precipitating electrons from 3 to 120 keV in 120-ms time resolution and characterized the features of suprathermal distributions associated with auroral arcs throughout the flight. The measured electrons were showing the inverted-V type spectra, consistent with the past measurements. In addition, investigations of the suprathermal electron population indicated the existence of the energetic non-thermal distribution corresponding to the brightest aurora.

Ogasawara, Keiichi↗

Detached Melt and Vapor Growth of InI in SUBSA hardware

Indium iodide (InI) single crystals, grown by the Bridgman process, have shown a significant promise as room temperature detector material for X-rays and γ-rays due to the large, close to ideal, bandgap of Eg = 2 eV, and high electrical resistivity. Yet the transport properties of the charge and the detector performance remain inadequate. The Bridgman growth of semiconductor crystals in microgravity have typically resulted in partial dewetting and Marangoni convection, which disturbed the diffusion-controlled growth and produced nonuniform dopant distribution. However, unconfined or partially confined solidification drastically reduced the number of stress-induced defects compared to the confined growth in crucibles on Earth.The goal of the present investigation was to explore melt growth of a heavy metal halide in microgravity, focusing on dewetting, in order to improve the crystalline perfection, i.e., to reduce the number of stress-related defects. InI was chosen because it is non-toxic and has a low melting point of only 365 C (~150 C below the melting point of InSb, used in the SUBSA experiments in 2002). Furthermore, InI melts and evaporates congruently, making it suitable for both growth by directional solidification and growth from the vapor phase. In preparation for the flight experiments, ground-based experiments were conducted in the SUBSA ground unit, consisting of 4 melt growth and 2 vapor growth experiments. The crystals were grown by a gradient freeze method by lowering the setpoint of the furnace. The transparent section of the SUBSA furnace did not allow observations of the solid-liquid interface. Contrary to our expectations, the possible occurrence of dewetting during growth could not be observed. We will present i) the ampoule design and preparation, ii) the experiments conducted in the SUBSA ground unit, iii) the images obtained during the microgravity experiments and iv) the results of the characterization of the grown crystals and detector fabrication.

Crystal Growth↗

Evidence for ground-state electron capture of K 40

Potassium-40 is a widespread, naturally occurring isotope whose radioactivity impacts estimated geological ages spanning billions of years, nuclear structure theory, and subatomic rare-event searches—including those for dark matter and neutrinoless double-beta decay. The decays of this long-lived isotope must be precisely known for its use as a geochronometer, and to account for its presence in low-background experiments. There are several known decay modes for potassium-40, but a predicted electron-capture decay directly to the ground state of argon-40 has never been observed. The existence of this decay mode impacts several fields, while theoretical predictions span an order of magnitude. Here we report on the first, successful observation of this rare decay mode, obtained by the KDK (potassium decay) Collaboration using a novel combination of a low-threshold x-ray detector surrounded by a tonne-scale, high-efficiency γ -ray tagger at Oak Ridge National Laboratory. A blinded analysis reveals a distinctly nonzero ratio of intensities of ground-state electron-captures ( I EC 0 ) over excited-state ones ( I EC * ) of I EC 0 / I EC * = 0.0095 ± stat 0.0022 ± sys 0.0010 (68% CL), with the null hypothesis rejected at 4 σ [Stukel et al. , Phys. Rev. Lett. 131 , 052503 (2023) ]. In terms of branching ratio, this unambiguous signal yields I EC 0 = 0.098 % ± stat 0.023 % ± sys 0.010 % , roughly half of the commonly used prediction. This first observation of a third-forbidden unique electron capture improves our understanding of low-energy backgrounds in dark-matter searches and has implications for nuclear-structure calculations. For example, a shell-model based theoretical estimate for the neutrinoless double-beta decay half-life of calcium-48 is increased by a factor of 7 - 2 + 3 . Our nonzero measurement shifts geochronological ages by up to a percent; implications are illustrated for Earth and solar system chronologies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Energy Radiation from Thunderstorms with ADELE: TGFs, Steps, and Glows

The biggest challenge in the study of high-energy processes in thunderstorms is getting a detector to the vicinity of the electrically active regions of a storm. The Airborne Detector for Energetic Lightning Emissions (ADELE) has been used to detect gamma rays from aircraft above storms and from a storm-chasing van on the ground. In August 2009, ADELE flew above Florida storms in a Gulfstream V jet, detecting the first terrestrial gamma-ray flash (TGF) seen from a plane and continuous glows of high-energy emission above thunderclouds. The presence of these glows suggests that a gradual process of relativistic runaway and feedback may help limit the total amount of charging in thunderstorms, in contrast to the traditional view that only lightning discharges compete with the charging process. The upper limits on TGF emission from intracloud and cloud-to-ground lightning from the ADELE flights demonstrated conclusively that a TGF of the sort seen from space is not associated with most lightning and not necessary to trigger it. In August 2010, observations from a van detected stepped-leader x-ray emission from at least four lightning strikes in ten days of operations. This mode of operation is therefore promising for future observations of the stepping process, although a more varied suite of instrumentation, in particular a flash-distance detector, would be useful. We will report on these results and on future possibilities for ADELE campaigns.

Smith, David M.↗

Observation of Long-Lived UV-Induced Fluorescence from Environmental Materials Using the HVeV Detector as Developed for SuperCDMS

Here, we describe recent experiments using a SuperCDMS HVeV single-charge sensitive detector illuminated with an ultraviolet LED (275 nm) and a monochromatic laser(650 nm) using a dual fiber optic system installed in a small dilution refrigerator at Stanford University. We observed a population of fluorescence background events after UV exposure but not after exposure to the laser source. The fluorescence was likely due to scattered UV photons absorbed outside the detector. We discuss the possibility of fluorescence being a contributor to the low energy excess background observed in above-ground Dark Matter experiments.

36 MATERIALS SCIENCE↗

Study of cosmogenic activation above ground for the DarkSide-20k experiment

The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39 Ar. Despite the outstanding capability of discriminating γ / β background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39 Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37 Ar and 3 H are shown not to be relevant due to short half-life and assumed purification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the location capabilities of a regional infrasonic network in Utah, US, using both ray tracing-derived and empirical-derived celerity-range and backazimuth models

SUMMARY More realistic models for infrasound signal propagation across a region can be used to improve the precision and accuracy of spatial and temporal source localization estimates. Motivated by incomplete infrasound event bulletins in the Western US, the location capabilities of a regional infrasonic network of stations located between 84–458 km from the Utah Test and Training Range, Utah, USA, is assessed using a series of near-surface explosive events with complementary ground truth (GT) information. Signal arrival times and backazimuth estimates are determined with an automatic F-statistic based signal detector and manually refined by an analyst. This study represents the first application of three distinct celerity-range and backazimuth models to an extensive suite of realistic signal detections for event location purposes. A singular celerity and backazimuth deviation model was previously constructed using ray tracing analysis based on an extensive archive of historical atmospheric specifications and is applied within this study to test location capabilities. Similarly, a set of multivariate, season and location specific models for celerity and backazimuth are compared to an empirical model that depends on the observations across the infrasound network and the GT events, which accounts for atmospheric propagation variations from source to receiver. Discrepancies between observed and predicted signal celerities result in locations with poor accuracy. Application of the empirical model improves both spatial localization precision and accuracy; all but one location estimates retain the true GT location within the 90 per cent confidence bounds. Average mislocation of the events is 15.49 km and average 90 per cent error ellipse areas are 4141 km2. The empirical model additionally reduces origin time residuals; origin time residuals from the other location models are in excess of 160 s while residuals produced with the empirical model are within 30 s of the true origin time. We demonstrate that event location accuracy is driven by a combination of signal propagation model and the azimuthal gap of detecting stations. A direct relationship between mislocation, error ellipse area and increased station azimuthal gaps indicate that for sparse networks, detection backazimuths may drive location biases over traveltime estimates.

58 GEOSCIENCES↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded-aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consist of 80- channel detector plane histograms that accumulate photon counts over periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey data set between 14 and 195 keV. Survey data comprise >90% of all BAT data by volume and allow for the tracking of long-term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey data set has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis Python package, a wrapper for HEASoftpy, which provides a modern, opensource pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources, including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the Python code and exemplify its usefulness and accuracy by analyzing survey data of the Crab Nebula, NGC 2992, and a previously uncataloged MAXI transient. The BatAnalysis package allows for ~18 yr of BAT survey data to be used in a systematic way to study a large variety of astrophysical sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded-aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consist of 80-channel detector plane histograms that accumulate photon counts over periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey data set between 14 and 195 keV. Survey data comprise >90% of all BAT data by volume and allow for the tracking of long-term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey data set has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis Python package, a wrapper for HEASoftpy, which provides a modern, open-source pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources, including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the Python code and exemplify its usefulness and accuracy by analyzing survey data of the Crab Nebula, NGC 2992, and a previously uncataloged MAXI transient. The BatAnalysis package allows for ~18 yr of BAT survey data to be used in a systematic way to study a large variety of astrophysical sources.

79 ASTRONOMY AND ASTROPHYSICS↗