Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Base and Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Mechanistic and Kinetic Analysis of Complete Methane Oxidation on a Practical PtPd/Al 2 O 3 Catalyst

A PtPd/Al 2 O 3 catalyst developed for the complete oxidation of methane from the ventilation air of underground coal mines is compared against a model PdO/Al 2 O 3 catalyst. Although the PtPd/Al 2 O 3 catalyst is substantially more active and stable than the model catalyst, the nature of active sites between the two catalysts is deemed to be fundamentally the same based on their response to different feed gas compositions and the evolution of surface CO adsorption complexes during time-resolved CO adsorption DRIFTS experiment. For both catalysts, coordinatively unsaturated Pd sites are considered the active centers for methane activation and the subsequent oxidation reaction. H 2 O competes with CH 4 for the same active sites, resulting in severe inhibition. Additionally, the CH 4 oxidation reaction also causes self-inhibition. Taking both inhibition effects into consideration, a relatively simple kinetic model is developed. The model provides a good fit of the 72 sets of kinetic data collected on the PtPd/Al 2 O 3 catalyst under practically relevant reaction conditions with CH 4 concentration in the range of 0.05–0.4%, H 2 O concentration of 1.0–5.0%, and reaction temperatures of 450–700 °C. Kinetic parameters based on the model suggest that the CH 4 activation energy on the PtPd/Al 2 O 3 catalyst is 96.7 kJ/mol, and the H 2 O adsorption energy is –31.0 kJ/mol. Both values are consistent with the parameters reported in the literature. The model can be used to develop catalyst sizing guidelines and be incorporated into the control algorithm of the catalytic system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of RTOG Consensus Guidelines for the Definition of the Clinical Target Volume for Postoperative Conformal Radiation Therapy for Prostate Cancer

Purpose: To define a prostate fossa clinical target volume (PF-CTV) for Radiation Therapy Oncology Group (RTOG) trials using postoperative radiotherapy for prostate cancer. Methods and Materials: An RTOG-sponsored meeting was held to define an appropriate PF-CTV after radical prostatectomy. Data were presented describing radiographic failure patterns after surgery. Target volumes used in previous trials were reviewed. Using contours independently submitted by 13 radiation oncologists, a statistical imputation method derived a preliminary 'consensus' PF-CTV. Results: Starting from the model-derived CTV, consensus was reached for a CT image-based PF-CTV. The PF-CTV should extend superiorly from the level of the caudal vas deferens remnant to >8-12 mm inferior to vesicourethral anastomosis (VUA). Below the superior border of the pubic symphysis, the anterior border extends to the posterior aspect of the pubis and posteriorly to the rectum, where it may be concave at the level of the VUA. At this level, the lateral border extends to the levator ani. Above the pubic symphysis, the anterior border should encompass the posterior 1-2 cm of the bladder wall; posteriorly, it is bounded by the mesorectal fascia. At this level, the lateral border is the sacrorectogenitopubic fascia. Seminal vesicle remnants, if present, should be included in the CTV if there is pathologic evidence of their involvement. Conclusions: Consensus on postoperative PF-CTV for RT after prostatectomy was reached and is available as a CT image atlas on the RTOG website. This will allow uniformity in defining PF-CTV for clinical trials that include postprostatectomy RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methodological guidelines on concrete degradation based on predictive models and the release of MOSAIC for industry use

In light-water reactors (LWRs), the concrete biological shield (CBS) designates the concrete structure directly facing the reactor pressure vessel (RPV). The primary function of the CBS is to protect equipment and personnel from the neutron and gamma radiation exiting the RPV. Most CBSs in operation in the United States also provide structural support to the RPV. Based on a long-term structural analysis, the structural integrity of the CBS to transfer the in-service passive load to the foundation, dynamic loading during an earthquake, and thermal loading during a loss-of-coolant accident (LOCA) must be maintained. Based on test reactor data for accelerated conditions, the mechanical properties of irradiated concrete are affected when exposed to neutron fluence higher than ≈ 10 19 n.cm -2 (E > 0.1 MeV). At 80 years of operation, the fluence estimates at the surface of the CBS range between 1×10 19 and 7×10 19 n.cm -2 (E > 0.1 MeV): the fluence value depends mostly on the design. Although fluence attenuates through the CBS by virtue of the shielding properties of concrete, about 5% to 10% of the CBS wall depth is affected by high fluence. The main degradation mechanism is the so-called radiation-induced volumetric expansion (RIVE) caused by the amorphization of aggregate-forming minerals. RIVE causes large deformation of up to 18% in pure quartz, and it also reduces the structural properties of concrete. The structural effects of long-term exposure to fast neutron irradiation in LWRs was studied in the report entitled “Assessment of the Effect of the Irradiation-Induced Degradation on the In-Service Structural Performance of the Concrete Biological Shields” (M3LW-23OR0403013). This report illustrates that (1) irradiation-induced damage expands further than the region subject to a cumulative fluence of 10 19 n.cm -2 (E > 0.1 MeV) to reach the steel reinforcement location, and (2) the irradiation-induced damage region shows no substantial residual bearing capacity and should not be accounted for in the integrity assessment of the CBS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Convergence Studies of Thermal and Electromagnetic Transient Quench Analysis of 11 GeV Super High Momentum Spectrometer Superconducting Magnets in Jefferson Lab

This paper presents results of convergence studies of transient thermal and electromagnetic quench analysis of five Super High Momentum Spectrometer (SHMS) superconducting magnets: HB, Q1, Q2, Q3, and Dipole, using Vector Fields Quench analysis codes. The convergence of the hot spot temperature and solution solve times were used to investigate the effects of element types, mesh densities, and tolerance criteria. The comparisons between tetrahedral elements and hexahedral elements was studied, and their advantages and disadvantages were discussed. Based on the results of convergence studies, a meshing guideline for coils is presented. The impact of iteration tolerance to the hot spot temperature was also explored, and it is found that tight tolerances result in extremely long solve times with only marginal improvements in the results.

43 PARTICLE ACCELERATORS↗

Test-Anchored Vibration Response Predictions for an Acoustically Energized Curved Orthogrid Panel with Mounted Components

rich body of vibroacoustic test data was recently generated at Marshall Space Flight Center for component-loaded curved orthogrid panels typical of launch vehicle skin structures. The test data were used to anchor computational predictions of a variety of spatially distributed responses including acceleration, strain and component interface force. Transfer functions relating the responses to the input pressure field were generated from finite element based modal solutions and test-derived damping estimates. A diffuse acoustic field model was applied to correlate the measured input sound pressures across the energized panel. This application quantifies the ability to quickly and accurately predict a variety of responses to acoustically energized skin panels with mounted components. Favorable comparisons between the measured and predicted responses were established. The validated models were used to examine vibration response sensitivities to relevant modeling parameters such as pressure patch density, mesh density, weight of the mounted component and model form. Convergence metrics include spectral densities and cumulative root-mean squared (RMS) functions for acceleration, velocity, displacement, strain and interface force. Minimum frequencies for response convergence were established as well as recommendations for modeling techniques, particularly in the early stages of a component design when accurate structural vibration requirements are needed relatively quickly. The results were compared with long-established guidelines for modeling accuracy of component-loaded panels. A theoretical basis for the Response/Pressure Transfer Function (RPTF) approach provides insight into trends observed in the response predictions and confirmed in the test data. The software developed for the RPTF method allows easy replacement of the diffuse acoustic field with other pressure fields such as a turbulent boundary layer (TBL) model suitable for vehicle ascent. Structural responses using a TBL model were demonstrated, and wind tunnel tests have been proposed to anchor the predictions and provide new insight into modeling approaches for this environment. Finally, design load factors were developed from the measured and predicted responses and compared with those derived from traditional techniques such as historical Mass Acceleration Curves and Barrett scaling methods for acreage and component-loaded panels.

Frady, Gregory P.↗

Towards yeast taxogenomics: lessons from novel species descriptions based on complete genome sequences

In recent years, ‘multi-omic’ sciences have affected all aspects of fundamental and applied biological research. Yeast taxonomists, though somewhat timidly, have begun to incorporate complete genomic sequences into the description of novel taxa, taking advantage of these powerful data to calculate more reliable genetic distances, construct more robust phylogenies, correlate genotype with phenotype and even reveal cryptic sexual behaviors. Furthermore, the use of genomic data in formal yeast species descriptions is far from widespread. The present review examines published examples of genome-based species descriptions of yeasts, highlights relevant bioinformatic approaches, provides recommendations for new users and discusses some of the challenges facing the genome-based systematics of yeasts.

59 BASIC BIOLOGICAL SCIENCES↗

Factors Affecting Fiber Design and Selection for Advanced Ceramic Composites

Structural Ceramic Matrix Composites (CMC) have the potential for application in the hot sections of a variety of advanced propulsion and power systems. It is therefore necessary to have a general understanding of the key properties of CMC and Reinforcing Fibers. This need is complicated by the wide variety of application conditions and structural requirements for which CMC's will be used, and the proprietary concerns of the design engineers. CMC's, to be successful, must display properties which are competitive with the currently used high temperature structural materials: (i.e., Iron and Nickel based superalloys, tough monolithic ceramics, and carbon/carbon composites.) Structural CMC offers several areas of competition: (1) performance, (i.e., strength and strength retention, creep resistance, and thermal conductivity), (2) reliability (i.e., environmental durability, and damage tolerance) and (3) processing (i.e., capability for varying sizes and shapes, and cost effective fabrication). The presentation further discusses, and illustrates with fiber and CMC data the key fiber properties and processes which strongly affect each CMC area of competition. The presentation further discusses the current knowledge of the important factors which control the key fiber properties. A design guidelines for the optimum fiber characteristics is developed, and the currently available fibers are compared against those guidelines.

DiCarlo, James A.↗

simuwatt - A Tablet Based Electronic Auditing Tool

'simuwatt Energy Auditor' (TM) is a new tablet-based electronic auditing tool that is designed to dramatically reduce the time and cost to perform investment-grade audits and improve quality and consistency. The tool uses the U.S. Department of Energy's OpenStudio modeling platform and integrated Building Component Library to automate modeling and analysis. simuwatt's software-guided workflow helps users gather required data, and provides the data in a standard electronic format that is automatically converted to a baseline OpenStudio model for energy analysis. The baseline energy model is calibrated against actual monthly energy use to ASHRAE Standard 14 guidelines. Energy conservation measures from the Building Component Library are then evaluated using OpenStudio's parametric analysis capability. Automated reporting creates audit documents that describe recommended packages of energy conservation measures. The development of this tool was partially funded by the U.S. Department of Defense's Environmental Security Technology Certification Program. As part of this program, the tool is being tested at 13 buildings on 5 Department of Defense sites across the United States. Results of the first simuwatt audit tool demonstration are presented in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Test-Anchored Vibration Response Predictions for an Acoustically Energized Curved Orthogrid Panel with Mounted Components

A rich body of vibroacoustic test data was recently generated at Marshall Space Flight Center for a curved orthogrid panel typical of launch vehicle skin structures. Several test article configurations were produced by adding component equipment of differing weights to the flight-like vehicle panel. The test data were used to anchor computational predictions of a variety of spatially distributed responses including acceleration, strain and component interface force. Transfer functions relating the responses to the input pressure field were generated from finite element based modal solutions and test-derived damping estimates. A diffuse acoustic field model was employed to describe the assumed correlation of phased input sound pressures across the energized panel. This application demonstrates the ability to quickly and accurately predict a variety of responses to acoustically energized skin panels with mounted components. Favorable comparisons between the measured and predicted responses were established. The validated models were used to examine vibration response sensitivities to relevant modeling parameters such as pressure patch density, mesh density, weight of the mounted component and model form. Convergence metrics include spectral densities and cumulative root-mean squared (RMS) functions for acceleration, velocity, displacement, strain and interface force. Minimum frequencies for response convergence were established as well as recommendations for modeling techniques, particularly in the early stages of a component design when accurate structural vibration requirements are needed relatively quickly. The results were compared with long-established guidelines for modeling accuracy of component-loaded panels. A theoretical basis for the Response/Pressure Transfer Function (RPTF) approach provides insight into trends observed in the response predictions and confirmed in the test data. The software modules developed for the RPTF method can be easily adapted for quick replacement of the diffuse acoustic field with other pressure field models; for example a turbulent boundary layer (TBL) model suitable for vehicle ascent. Wind tunnel tests have been proposed to anchor the predictions and provide new insight into modeling approaches for this type of environment. Finally, component vibration environments for design were developed from the measured and predicted responses and compared with those derived from traditional techniques such as Barrett scaling methods for unloaded and component-loaded panels.

Frady, Gregory P.↗

Palliative Radiotherapy for Bone Metastases: An ASTRO Evidence-Based Guideline

Purpose: To present guidance for patients and physicians regarding the use of radiotherapy in the treatment of bone metastases according to current published evidence and complemented by expert opinion. Methods and Materials: A systematic search of the National Library of Medicine's PubMed database between 1998 and 2009 yielded 4,287 candidate original research articles potentially applicable to radiotherapy for bone metastases. A Task Force composed of all authors synthesized the published evidence and reached a consensus regarding the recommendations contained herein. Results: The Task Force concluded that external beam radiotherapy continues to be the mainstay for the treatment of pain and/or prevention of the morbidity caused by bone metastases. Various fractionation schedules can provide significant palliation of symptoms and/or prevent the morbidity of bone metastases. The evidence for the safety and efficacy of repeat treatment to previously irradiated areas of peripheral bone metastases for pain was derived from both prospective studies and retrospective data, and it can be safe and effective. The use of stereotactic body radiotherapy holds theoretical promise in the treatment of new or recurrent spine lesions, although the Task Force recommended that its use be limited to highly selected patients and preferably within a prospective trial. Surgical decompression and postoperative radiotherapy is recommended for spinal cord compression or spinal instability in highly selected patients with sufficient performance status and life expectancy. The use of bisphosphonates, radionuclides, vertebroplasty, and kyphoplasty for the treatment or prevention of cancer-related symptoms does not obviate the need for external beam radiotherapy in appropriate patients. Conclusions: Radiotherapy is a successful and time efficient method by which to palliate pain and/or prevent the morbidity of bone metastases. This Guideline reviews the available data to define its proper use and provide consensus views concerning contemporary controversies or unanswered questions that warrant prospective trial evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mixed-Valent Copper Chalcogenides: Tuning Structures and Electronic Properties Using Multiple Anions

A series of mixed-anion copper chalcogenides have been prepared using solid-state methods including ACu 4.2 TeS 2 (A = K, Rb, Cs), which adopt the KCu 4 S 3 structure type. The mixedanion motif has an expanded sublattice, relative to KCu 4 S 3 , that can accommodate additional Cu atoms at its interstitial sites that are unoccupied in the parent structure. The variable temperature transport shows that the materials are p-type metals with carrier densities on the order of 10 21 cm -3 and room-temperature electrical conductivity as high as 4000 S cm -1 . Band structures calculated using density functional theory corroborate the experimental data and indicate that the interstitial Cu atoms lower the carrier concentration and increase the Fermi level of the materials. The layered structure has Te and S atoms occupying unique sites within the ACu 4.2 TeS 2 structure, where relatively hard S 2- anions prefer Wyckoff positions where they can form energetically favorable acid-base interactions with hard alkali cations. The phenomenon is observed in the related K 3 Cu 8 Te 2 S 4 system, which also has a fully ordered layered structure. Here, we believe that the report provides new chemical guidelines for targeting ordered multianion structures, as well as a unique method for tuning the electronic properties of metallic chalcogenides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

SERVIR: Cross-Comparison of Carbon Emission Estimates Based on Variable Land Use Land Cover Changes within SERVIR Focus Regions

Deforestation in the tropics contributes approximately one-fifth of the annual global greenhouse gas (GHG) emissions. In an effort to reduce GHG emissions, SERVIR - a joint USAID and NASA initiative - is currently implementing the SERVIR CArbon Pilot (S-CAP) activity. By developing a comprehensive CO2 tracking system in Google Earth Engine based on both remotely sensed data and in situ observations, S-CAP aims to build capacity within the SERVIR regional hubs to improve decision making and local monitoring efforts surrounding GHG emissions. The S-CAP estimations are being completed throughout 11 pilot countries within the SERVIR regions of Asia, Africa, and the Americas to integrate partner contributions and local input into the development process. These emission estimate calculations use country-level REDD+ FREL reported values, global remotely sensed data (e.g. Global Forest Watch) and regional datasets and are completed using the IPCC Guidelines for National Greenhouse Gas Inventories. From the S-CAP activity thus far, country CO2 estimations had varied differences, ranging from 56% to 197% between their lowest and highest estimates. The results from this study show that CO2 emission estimates can differ greatly depending on the land cover data sets used as well as the biomass values, and how a comprehensive database is essential in understanding the full range of impacts that land cover change has in these regions. Using this ensemble approach, SERVIR hubs can better select the most appropriate datasets available for estimating emissions.

Carbon Emission↗

Cyberknife Image-Guided Delivery and Quality Assurance

The CyberKnife is a complex, emerging technology that is a significant departure from current stereotactic radiosurgery and external beam radiotherapy technologies. In its clinical application and quality assurance (QA) approach, the CyberKnife is currently situated somewhere in between stereotactic radiosurgery and radiotherapy. The clinical QA for this image-guided treatment delivery system typically follows the vendor's guidance, mainly because of the current lack of vendor-independent QA recommendations. The problem has been exacerbated because very little published data are available for QA for the CyberKnife system, especially for QA of the interaction between individual system components. The tools and techniques for QA of the CyberKnife are under development and will continue to improve with longer clinical experience of the users. The technology itself continues to evolve, forcing continuous changes and adaptation of QA. To aid in the process of developing comprehensive guidance on CyberKnife QA, a database of errors based on users reporting incidents and corrective actions would be desirable. The goal of this work was to discuss the status of QA guidelines in the clinical implementation of the CyberKnife system. This investigation was done from the perspective of an active clinical and research site using the CyberKnife.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FURTHER EVALUATION OF BOOTSTRAP RESAMPLING AS A TOOL FOR RADIO-INTERFEROMETRIC IMAGING FIDELITY ASSESSMENT

We report on a broader evaluation of statistical bootstrap resampling methods as a tool for pixel-level calibration and imaging fidelity assessment in radio interferometry. Pixel-level imaging fidelity assessment is a challenging problem, important for the value it holds in robust scientific interpretation of interferometric images, enhancement of automated pipeline reduction systems needed to broaden the user community for these instruments, and understanding leading-edge direction-dependent calibration and imaging challenges for future telescopes such as the Square Kilometre Array. This new computational approach is now possible because of advances in statistical resampling for data with long-range dependence and the available performance of contemporary high-performance computing resources. We expand our earlier numerical evaluation to span a broader domain subset in simulated image fidelity and source brightness distribution morphologies. As before, we evaluate the statistical performance of the bootstrap resampling methods against direct Monte Carlo simulation. We find that both model-based and subsample bootstrap methods continue to show significant promise for the challenging problem of interferometric imaging fidelity assessment when evaluated over the broader domain subset. We report on their measured statistical performance and guidelines for their use and application in practice. We also examine the performance of the underlying polarization self-calibration algorithm used in this study over a range of parallactic angle coverage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Visual Analytics Environments: The Road to the Visual Analytics Science and Technology Challenge Evaluation Methodology

The evaluation of visual analytics environments was a topic in Illuminating the Path [Thomas 2005] as a critical aspect of moving research into practice. For a thorough understanding of the utility of the systems available, evaluation not only involves assessing the visualizations, interactions or data processing algorithms themselves, but also the complex processes that a tool is meant to support (such as exploratory data analysis and reasoning, communication through visualization, or collaborative data analysis [Lam 2012; Carpendale 2007]). Researchers and practitioners in the field have long identified many of the challenges faced when planning, conducting, and executing an evaluation of a visualization tool or system [Plaisant 2004]. Evaluation is needed to verify that algorithms and software systems work correctly and that they represent improvements over the current infrastructure. Additionally to effectively transfer new software into a working environment, it is necessary to ensure that the software has utility for the end-users and that the software can be incorporated into the end-user’s infrastructure and work practices. Evaluation test beds require datasets, tasks, metrics and evaluation methodologies. As noted in [Thomas 2005] it is difficult and expensive for any one researcher to setup an evaluation test bed so in many cases evaluation is setup for communities of researchers or for various research projects or programs. Examples of successful community evaluations can be found [Chinchor 1993; Voorhees 2007; FRGC 2012]. As visual analytics environments are intended to facilitate the work of human analysts, one aspect of evaluation needs to focus on the utility of the software to the end-user. This requires representative users, representative tasks, and metrics that measure the utility to the end-user. This is even more difficult as now one aspect of the test methodology is access to representative end-users to participate in the evaluation. In many cases the sensitive nature of data and tasks and difficult access to busy analysts puts even more of a burden on researchers to complete this type of evaluation. User-centered design goes beyond evaluation and starts with the user [Beyer 1997, Shneiderman 2009]. Having some knowledge of the type of data, tasks, and work practices helps researchers and developers know the correct paths to pursue in their work. When access to the end-users is problematic at best and impossible at worst, user-centered design becomes difficult. Researchers are unlikely to go to work on the type of problems faced by inaccessible users. Commercial vendors have difficulties evaluating and improving their products when they cannot observe real users working with their products. In well-established fields such as web site design or office software design, user-interface guidelines have been developed based on the results of empirical studies or the experience of experts. Guidelines can speed up the design process and replace some of the need for observation of actual users [heuristics review references]. In 2006 when the visual analytics community was initially getting organized, no such guidelines existed. Therefore, we were faced with the problem of developing an evaluation framework for the field of visual analytics that would provide representative situations and datasets, representative tasks and utility metrics, and finally a test methodology which would include a surrogate for representative users, increase interest in conducting research in the field, and provide sufficient feedback to the researchers so that they could improve their systems.

evaluation↗

Fluid dynamic simulation and analysis of water-cooling systems for the Electron-Ion Collider

The Electron-Ion Collider is the newest large-scale project at Brookhaven National Laboratory. The collider’s purpose is to provide further advancements in the knowledge of the universe’s origin by accelerating particles near the speed of light. Our project for this 3.8 km ring was to create a thermal hydraulic steady-state simulation design of the water-cooling system to be cost-effective and energy efficient, as envisioned by Charlie Foltz, the EIC Infrastructure Division Director. The system would include a supply and return header, which cools several thousand components of the ring. The water would then be returned and cooled down using a system of cooling towers and plate and frame heat exchangers. Due to the size of the system and the complexity of the network analysis, a fluid dynamic simulation software, AFT Fathom, was used. Since previous methods of maintaining systems relied on building upon smaller real-life models and implementing empirical data, this flow model was unique and first of a kind in the domain of accelerator design, construction and operation. Therefore, our hydraulic team piloted a new method to perform network analysis on a large scale cooling system. We successfully created several test scenarios for system behavior in a shorter time compared to the method of performing hand calculations. Cooling specifications for heat rejection, pressure drop, flow rate, and pipe sizing were changed based on the individual systems of the vacuum, radio frequency (RF), magnet and power supply, and cryogenics sections. Finally, we used DOE guidelines to perform life-cycle cost analysis with net present value and carbon saving analysis on the systems where pipe size could be optimized.

43 PARTICLE ACCELERATORS↗