Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

DARWIN: towards the ultimate dark matter detector

DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/ c {sup 2}, such a detector with its large mass, low-energy threshold and ultra-low background level will also be sensitive to other rare interactions. It will search for solar axions, galactic axion-like particles and the neutrinoless double-beta decay of {sup 136}Xe, as well as measure the low-energy solar neutrino flux with < 1% precision, observe coherent neutrino-nucleus interactions, and detect galactic supernovae. We present the concept of the DARWIN detector and discuss its physics reach, the main sources of backgrounds and the ongoing detector design and R and D efforts.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a segmented 6 Li-loaded liquid scintillator detector for the PROSPECT experiment

This study describes the design and performance of a 50 liter, two-segment 6 Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6 Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6 Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. Finally, the detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for new physics at μ → e facilities with μ + and π + decays at rest

We investigate the ability of μ → e facilities, Mu2e and COMET, to probe, or discover, new physics with their detector validation datasets. The validation of the detector response may be performed using a dedicated run with μ + , collecting data below the Michel edge, E e ≲ 52 MeV ; an alternative strategy using π + → e + ν e may also be considered. We focus primarily on a search for a monoenergetic e + produced via two-body decays μ + → e + X or π + → e + X , with X a light new physics particle. Mu2e can potentially explore new parameter space beyond present astrophysical and laboratory constraints for a set of well motivated models including axionlike particles with flavor violating couplings ( μ + → e + a ), massive Z ′ bosons ( μ + → Z ′ e + ), and heavy neutral leptons ( π + → e + N ). The projected sensitivities presented herein can be achieved in a matter of days. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Analysis of Muon Neutrino Disappearance from the NuMI Beam Using an Optimal Track Fitter

The NOvA experiment is a long-baseline neutrino oscillation experiment based out of Fermilab National Accelerator Laboratory that uses two liquid scintillator detectors, one at Fermilab (the \near" detector) and a second 14 kton detector in northern Minnesota (the \far" detector.) The primary physics goals of the NOvA experiment are to measure neutrino mixing parameters through both the v μ disappearance and v e appearance channels using neutrinos from the newly upgraded NuMI beam line. The NOvA v μ disappearance analysis can significantly improve the world's best measurement of sin 2 θ 23 . This analysis proceeds by using the measured v μ charged-current energy spectrum in the near detector to predict the spectrum in the far detector, and comparing this to the measured spectrum to obtain a best fit for the oscillation parameters sin 2 θ 23 and Δm 2 32 . Since this fit is governed by the shape of the energy spectrum, the best fit will be maximized by obtaining the best possible energy resolution for the individual neutrino events. This dissertation describes an alternate v μ disappearance analysis technique for the NOvA experiment, based on the idea that estimating the energy resolution of the individual events will allow them to be separated into different energy resolution samples in order to improve the final fit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ATCA/muTCA for Physics

ATCA/{mu}TCA platforms are attractive because of the modern serial link architecture, high availability features and many packaging options. Less-demanding availability applications can be met economically by scaling back speed and redundancy. The ATCA specification was originally targeted for the Telecom industry but has gained recently a much wider user audience. The purpose of this paper is to report on present hardware and software R and D efforts where ATCA and {mu}TCA are planned, already being used or in development using selected examples for accelerator and detectors in the Physics community. It will present also the status of a proposal for physics extensions to ATCA/{mu}TCA specifications to promote inter-operability of laboratory and industry designs for physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Report on the Belle II Summer Workshop and Explorer Workshop 2023

The 2023 Belle II Summer workshop took place July 24-28, 2023 at Duke University in Durham. The meeting webpage can be found at https://indico.belle2.org/event/8841/. The meeting had 58 registered participants with the overwhelming majority attending in person. The event at giving beginning graduate students and postdocs an overview over the Belle II physics program and detector as well as an in-depth exploration of the Belle II software. For the latter, several hands-on sessions were organized to introduce participants to the Belle II software as well as more specialized topics in statistics and Machine Learning. The workshop also featured an ML/AI competition. In addition to the DOE support, the workshop was also supported by the Duke Physics department. We were able to host almost all students that so wished in the Duke Dorms and provide a meal plan. The support enabled us to waive the registration fee for all participants and cover also part of the dorm costs. Furthermore, we covered travel costs for external speakers on ML/AI topics. Figures 1 and 2 show the group picture and a scene from the hands-on sessions, respectively.

99 GENERAL AND MISCELLANEOUS↗

The HADES-at-FAIR project

After the completion of the experimental program at SIS18 the HADES setup will migrate to FAIR, where it will deliver high-quality data for heavy-ion collisions in an unexplored energy range of up to 8 A GeV. In this contribution, we briefly present the physics case, relevant detector characteristics and discuss the recently completed upgrade of HADES.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data to Reduce Uncertainties in Reactor Antineutrino Measurements

The large quantities of antineutrinos produced through the decay of fission fragments in nuclear reactors provide an opportunity to study the properties of these particles and investigate their use in reactor monitoring. The reactor antineutrino spectra are measured using specialized, large area detectors that detect antineutrinos through inverse beta decay, electron elastic scattering, or coherent elastic neutrino nucleus scattering; although, inverse beta decay is the only demonstrated method so far. Reactor monitoring takes advantage of the differences in the antineutrino yield and spectra resulting from uranium and plutonium fission providing an opportunity to estimate the fissile material composition in the reactor. Recent experiments reveal a deviation between the measured and calculated antineutrino flux and spectra (the reactor anomaly) indicating either the existence of yet undiscovered neutrino physics, uncertainties in the reactor source term calculation, incorrect nuclear data, or a combination of all three. To address the nuclear data that impact the antineutrino spectrum calculations and measurements, an international group of over 180 experts in antineutrino physics, reactor analysis, detector development, and nuclear data came together during the Workshop on Nuclear Data for Reactor Antineutrino Measurements (WoNDRAM) to discuss nuclear data needs and achieve concordance on a set of recommended priorities for nuclear data improvements. Three topical sessions focused on the reactor source term, the antineutrino spectrum, and the detector response, provided a forum to gain consensus amongst the participants on the most important data improvements to address two goals: 1) understand the reactor anomaly and 2) improve the ability to monitor reactors using antineutrinos. This report summarizes the outcomes of the workshop discussions and the recommendations for nuclear data efforts that reduce reactor antineutrino measurement uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiment to demonstrate separation of Cherenkov and scintillation signals

The ability to separately identify the Cherenkov and scintillation light components produced in scintillating mediums holds the potential for a major breakthrough in neutrino detection technology, allowing development of a large, low-threshold, directional detector with a broad physics program. Furthermore, the CHESS (CHErenkov/Scintillation Separation) experiment employs an innovative detector design with an array of small, fast photomultiplier tubes and state-of-the-art electronics to demonstrate the reconstruction of a Cherenkov ring in a scintillating medium based on photon hit time and detected photoelectron density. Our paper describes the physical properties and calibration of CHESS along with first results. The ability to reconstruct Cherenkov rings are demonstrated in a water target, and a time precision of 338 ± 12 ps FWHM is achieved. Finally, Monte Carlo–based predictions for the ring imaging sensitivity with a liquid scintillator target predict an efficiency for identifying Cherenkov hits of 94 ± 1 % and 81 ± 1 % in pure linear alkyl benzene (LAB) and LAB loaded with 2 g/L of a fluor, PPO, respectively, with a scintillation contamination of 12 ± 1 % and 26 ± 1 % .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo calculation and verification of the geometrical factors for the NPDGamma experiment

The NPDGamma experiment measures the parity-violating asymmetry in gamma-ray emission in the capture of polarized neutrons on liquid parahydrogen. The sensitivity to the asymmetry for each detector in the array is used as a parameter in the extraction of the physics asymmetry from the measured data. The detector array is approximately cylindrically symmetric around the target and a step-wise sinusoidal function has been used for the sensitivity in the previous iteration of the NPDGamma experiment, but deviations from cylindrical symmetry necessitate the use of a Monte Carlo model to determine corrections to the geometrical factors. For the calculations, source code modifications to MCNPX were done in order to calculate the sensitivity of each cesium iodide detector to the physics asymmetry. We describe the MCNPX model and results from calculations and how the results are validated through measurement of the parity violating asymmetry of gamma-rays from neutron capture on chlorine.

Grammer, K. B.↗

Enabling U.S. participation in Future Higgs Factories

Exciting proposals for a new Higgs factory collider, aimed at the search for new physics and precision studies of particles and forces, especially measurement of the Higgs boson couplings at the loop level, will be evaluated as part of the Snowmass process. Potential facilities include (among others) ILC, FCC-ee, C3, CEPC, CLIC, muon collider and advanced accelerator concepts being investigated by Snowmass topical group AF6, potentially located in Asia, Europe, or the United States. The European Strategy has endorsed an electron-positron Higgs factory as its highest priority after HL-LHC. Much of the detector, software, and physics preparative studies needed for these machines is in common, and is currently being implemented by physicists world-wide. In this white paper for the 2021 Snowmass process we look at current global activity on future Higgs factories and give examples of investments that could be made in these common areas over the next five years to establish a leadership role for the U.S. in a future Higgs factory, wherever it is built. The U.S. high energy physics program confronts a number of challenges that a strong role in the study of the Higgs boson can address. These include, in addition to the scientific results, maintaining leading roles in international partnerships, nurturing and advancing world-leading capabilities and expert resources, and maintaining and attracting talent. The international effort would benefit from increased U.S. participation, and the U.S., in turn, would maintain stature through the partnership.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of Inclusive Muon Neutrino Charged Current Triple Differential Cross Section on Argon

The field of accelerator neutrino experiments is entering an era of precision oscillation measurements where the remaining unknown neutrino measurements will be determined. The upcoming DUNE and Hyper-K experiments aim to determine the neutrino mass hierarchy and degree of Charge-Parity (CP) violation in the neutrino sector, providing potential insight on the matter-antimatter imbalance observed in the universe. However, these experiments require highly accurate measurements, and neutrino cross section modeling uncertainties may limit their capabilities. Cross section measurements at current- generation experiments can aid the development of neutrino interaction models to reduce these uncertainties. This is especially true for measurements of neutrino energy, as it drives neutrino oscillations and is of key importance to oscillation experiments. The MicroBooNE experiment uses a Liquid Argon Time Projection Chamber (LArTPC) to produce neutrino-argon cross sections as one of its physics goals. The MicroBooNE detector’s fully active volume, precision reconstruction, and calorimetry information are leveraged in the Wire-Cell analysis to produce a muon neutrino selection that is 92% pure while maintaining 68% efficiency. A reconstruction chain featuring a fully 3D charge reconstruction and a graph-based particle trajectory fit are used to produce accurate measurements of lepton kinematics as well as visible hadronic energy produced in a neutrino interaction. This thesis presents the first neutrino-argon triple-differential cross section measurement, targeting inclusive charged-current final states. Wiener SVD unfolding is used to produce a measurement over neutrino energy, muon momentum, and muon scattering angle. A series of constrained goodness of fit tests are used to demonstrate the validity of MicroBooNE’s model in describing the distribution of reconstructed kinematics seen in data to ensure the accuracy of unfolding. The validated unfolding to neutrino energy represents a step forward in the field of neutrino cross sections, and demonstrates the capabilities of the LArTPC detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPLENDAQ: A Detector-Agnostic Data Acquisition System for Small-Scale Physics Experiments

Many scientific applications from rare-event searches to condensed matter system characterization to high-rate nuclear experiments require time-domain triggering on a raw stream of data, where the triggering is generally threshold-based or randomly acquired. When carrying out detector R &D, there is a need for a general data acquisition (DAQ) system to quickly and efficiently process such data. In the SPLENDOR collaboration, we are developing the Python-based SPLENDAQ package for this exact purpose—it offers two main features for offline analysis of continuous data: a threshold triggering algorithm based on the time-domain optimal filter formalism and an algorithm for randomly choosing nonoverlapping segments for noise measurements. Further, combined with the commercially available Moku platform, developed by Liquid Instruments, we have a full pipeline of event building off raw data with minimal setup. Here, we review the underlying principles of this detector-agnostic DAQ package and give concrete examples of its utility in various applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of Two Phase (Liquid/Gas) Xenon Gamma-Camera for the Detection of Special Nuclear Material and PET Medical Imaging

The McKinsey group at Yale has been awarded a grant from DTRA for the building of a Liquid Xenon Gamma Ray Color Camera (LXe-GRCC), which combines state-of-the-art detection of LXe scintillation light and time projection chamber (TPC) charge readout. The DTRA application requires a movable detector and hence only a single phase (liquid) xenon detector can be considered in this case. We propose to extend the DTRA project to applications that allow a two phase (liquid/gas) xenon TPC. This entails additional (yet minimal) hardware and extension of the research effort funded by DTRA. The two phase detector will have better energy and angular resolution. Such detectors will be useful for PET medical imaging and detection of special nuclear material in stationary applications (e.g. port of entry). The expertise of the UConn group in gas phase TPCs will enhance the capabilities of the Yale group and the synergy between the two groups will be very beneficial for this research project as well as the education and research projects of the two universities. The LXe technology to be used in this project has matured rapidly over the past few years, developed for use in detectors for nuclear physics and astrophysics. This technology may now be applied in a straightforward way to the imaging of gamma rays. According to detailed Monte Carlo simulations recently performed at Yale University, energy resolution of 1% and angular resolution of 3 degrees may be obtained for 1.0 MeV gamma rays, using existing technology. With further research and development, energy resolution of 0.5% and angular resolution of 1.3 degrees will be possible at 1.0 MeV. Because liquid xenon is a high density, high Z material, it is highly efficient for scattering and capturing gamma rays. In addition, this technology scales elegantly to large detector areas, with several square meter apertures possible. The Yale research group is highly experienced in the development and use of noble liquid detectors for astrophysics, most recently in the XENON10 experiment. The existing facilities at Yale are fully adequate for the completion of this project. The facilities of the UConn group at the LNS at Avery Point include a (clean) lab for detector development and this group recently delivered an Optical Readout TPC (O-TPC) for research in Nuclear Astrophysics at the TUNL in Duke University. The machine shop at UConn will be used (free of charge) for producing the extra hardware needed for this project including grids and frames.

07 ISOTOPE AND RADIATION SOURCES↗

Instrumentation and Control Selection for the 12 GeV Hall-B Magnets at Jefferson Lab

Here, as part of the Jefferson Lab 12 GeV accelerator upgrade, the Experimental Physics Hall B detector system requires two superconducting magnets – a Torus and a Solenoid. The specifications required maximum space for the detectors which led to the choice of conduction cooling for each magnet. The Torus consists of 6 trapezoidal 'race-track'-type coils connected in series with an operating current of 3770 A. The Solenoid is an actively shielded 5 Tesla magnet consisting of 5 coils connected in series operating at 2416 A. Within the hall the two magnets are located in close proximity to each other and are surrounded by particle detectors. We describe the philosophy behind the instrumentation selection and control design that accounts for this proximity and other challenging working conditions. We describe the choice of sensor technologies, as well as the control and data acquisition methods. The magnet power and cryogenic control sub-systems are implemented using Allen Bradley Control Logix 1756-L72 Programmable Logic Controllers. Sensor instrumentation read-backs are routed into the PLC via National Instruments cRIO hardware (Field Programmable Gate Arrays or FPGA/RT application) using Jefferson Lab designed FPGA-based multi-sensor-excitation-chassis. Configuration, monitoring, and alarm handlers for the magnet systems are provided via an Experimental Physics Instrumentation & Control System interface (EPICS). Failure Modes and Effects Analysis (FMEA) and the requirement to monitor critical parameters during operation guided the selection of instrumentation and associated hardware. The design of the quench protection and voltage tap sub-systems was driven by the anticipated level of voltages developed during a magnet quench. The primary hard-wired quench detection and protection sub-system together with the secondary PLC-based protection sub-system is also discussed. The successful commissioning and subsequent performance of these magnets demonstrates the robustness of the design and implementation approach that was adopted by the Jefferson Lab team and serves as an excellent 'How To' guide for future projects of this size and complexity.

12 GeV↗