Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Pilot Study on the Investigation of Tear Fluid Biomarkers as an Indicator of Ocular, Neurological, and Immunological Health in Astronauts

The purpose of this pilot study is to investigate the collection, preparation, and analysis of tear biomarkers as a means of assessing ocular, neurological, and immunological health. At present, no published data exists on the cytokine profiles of tears from astronauts exposed to long periods of microgravity and space irradiations. In addition, no published data exist on cytokine (biomarker) profiles of tears that have been collected from irradiated non-human biological systems (primates and other animal models). A goal for the proposed pilot study is to discover novel tear biomarkers which can help inform researchers, clinicians, epidemiologist and healthcare providers about the health status of a living biological system, as well as informing them when a disease state is triggered. This would be done via analysis of the onset of expression of pro-inflammatory cytokines, leading up to the full progression of a disease (i.e. cancer, loss of vision, radiation-induced oxidative stress, cardiovascular disorders, fibrosis in major organs, bone loss). Another goal of this pilot study is to investigate the state of disease against proposed medical countermeasures, in order to determine whether the countermeasures are efficacious in preventing or mitigating these injuries. An example of an up and coming tear biomarker technology, Ascendant Dx, a clinical stage diagnostic company, is developing a screening test to detect breast cancer using proteins from tears. The team utilized Liquid Chromatography -Mass Spectrometry with Mass analysis (LC MS/MS) as a discovery platform followed by validation with ELISA to come up with a panel of protein biomarkers that can differentiate breast cancer samples from control ("cancer free") samples with results far surpassing the results of imaging techniques in use today. Continued research into additional proteins is underway to increase the sensitivity and specificity of the test and development efforts are on the way to transfer the test onto a fast, accurate and inexpensive point of care platform. In conclusion, the expected results from this proposed pilot study are to: a) establish an SOP for retrieving/storing/transporting tear fluid samples from multicentre sites b) establish a normal range for relevant biomarkers in tears; and c) establish a database (biobank) of tears of space naïve versus veteran astronauts, to establish a personal baseline for long-term ocular health monitoring

Morton, Stephen↗

Feedback controlled electrostatic and electromagnetic sample positioners

Four different sample positioners are discussed. The four systems share a common operating principle in that the sample positioning is achieved by feedback controlled forces which can be electrostatic, dielectrophoretic, or electromagnetic. The first system is the electrostatic liquid drop positioner which operates at the near ambient position. The second system is the tetrahedral electrostatic positioner which is being developed for the high temperature materials processing in vacuum. The third system is essentially the the same tetrahedral system above except that the position control is achieved by dielectrophoretic forces in the pressurized gas environment. Finally, the feasibility of a feedback controlled electromagnetic positioner is discussed.

Rhim, Won-Kyu↗

A Comparison of Model Predictive Control Architectures for Application to Electrified Aircraft Propulsion Systems

As electrified aircraft propulsion (EAP) systems continue to mature, more sophisticated hardware and software are being developed to balance operations among electric machines and gas-turbine engines. In hybrid-electric propulsion systems, the increased complexity resulting from integrating turbine-engine shafts with electric machines necessitates control methodologies to account for various physical domains. Ideal controllers for hybrid-electric engines manage systems, subsystems, and their interactions in a coordinated fashion, able to account for safety and performance goals while being computationally efficient. In a previous work, linear model predictive control (MPC) schemes were implemented in centralized and distributed frameworks on a nonlinear turbofan engine model as a proof of concept. However, these schemes were not evaluated for computational complexity, prompting further study. The research presented here develops hierarchical MPC schemes to reduce the computational burden of the previous MPC schemes. A two-tier framework is implemented, where a slower sampling MPC controls electric machines and determines fan-speed tracking goals for a faster sampling controller, which is either a MPC or a proportional-integral (PI) controller. The proposed designs are compared to the centralized MPC investigated previously, and performance is measured via fan speed tracking error, energy storage state-of-charge, and computation time. Results reveal that the hierarchical MPC scheme employing a lower-level PI controller improves computation time while maintaining comparable tracking and state-of-charge regulation to the centralized scheme.

model predictive control↗

A Comparison of Model Predictive Control Architectures for Application to Electrified Aircraft Propulsion Systems

As electrified aircraft propulsion (EAP) systems continue to mature, more sophisticated hardware and software are being developed to balance operations among electric machines and gas-turbine engines. In hybrid-electric propulsion systems, the increased complexity resulting from integrating turbine-engine shafts with electric machines necessitates control methodologies to account for various physical domains. Ideal controllers for hybrid-electric engines manage systems, subsystems, and their interactions in a coordinated fashion, able to account for safety and performance goals while being computationally efficient. In a previous work, linear model predictive control (MPC) schemes were implemented in centralized and distributed frameworks on a nonlinear turbofan engine model as a proof of concept. However, these schemes were not evaluated for computational complexity, prompting further study. The research presented here develops hierarchical MPC schemes to reduce the computational burden of the previous MPC schemes. A two-tier framework is implemented, where a slower sampling MPC controls electric machines and determines fan-speed tracking goals for a faster sampling controller, which is either a MPC or a proportional-integral (PI) controller. The proposed designs are compared to the centralized MPC investigated previously, and performance is measured via fan speed tracking error, energy storage state-of-charge, and computation time. Results reveal that the hierarchical MPC scheme employing a lower-level PI controller improves computation time while maintaining comparable tracking and state-of-charge regulation to the centralized scheme.

model predictive control↗

Electric Field Containerless Processing Technology

The objective of this task is to develop the science and technology base required to design and construct a high temperature electric field positioning module that could be used by materials scientists to conduct containerless science experiments in a low gravity environment. Containerless science modules that employ electric fields to position and manipulate samples offer several advantages over acoustic or electromagnetic systems. The electric field system will operate not only at atmospheric pressures but also in a vacuum, in contrast to the acoustic modules which can only operate in atmosphere where the acoustic forces are sufficient. The electric field technique puts minimum energy into the sample, whereas the electromagnetic system can deposit energy into the sample through eddy current heat as well as physical mixing in the sample. Two types of electric field modules have been constructed and tested to date. One employs a charged sample and uses electrostatic forces to position and control the sample. The second type of module induces electrical polarization of the sample and electric field gradients to position and control the sample.

Elleman, D. D.↗

Sample-Clock Phase-Control Feedback

To demodulate a communication signal, a receiver must recover and synchronize to the symbol timing of a received waveform. In a system that utilizes digital sampling, the fidelity of synchronization is limited by the time between the symbol boundary and closest sample time location. To reduce this error, one typically uses a sample clock in excess of the symbol rate in order to provide multiple samples per symbol, thereby lowering the error limit to a fraction of a symbol time. For systems with a large modulation bandwidth, the required sample clock rate is prohibitive due to current technological barriers and processing complexity. With precise control of the phase of the sample clock, one can sample the received signal at times arbitrarily close to the symbol boundary, thus obviating the need, from a synchronization perspective, for multiple samples per symbol. Sample-clock phase-control feedback was developed for use in the demodulation of an optical communication signal, where multi-GHz modulation bandwidths would require prohibitively large sample clock frequencies for rates in excess of the symbol rate. A custom mixedsignal (RF/digital) offset phase-locked loop circuit was developed to control the phase of the 6.4-GHz clock that samples the photon-counting detector output. The offset phase-locked loop is driven by a feedback mechanism that continuously corrects for variation in the symbol time due to motion between the transmitter and receiver as well as oscillator instability. This innovation will allow significant improvements in receiver throughput; for example, the throughput of a pulse-position modulation (PPM) with 16 slots can increase from 188 Mb/s to 1.5 Gb/s.

Quirk, Kevin J.↗

Metabolic Profiling of Volatile Organic Compounds (VOCs) Emitted by the Pathogens Francisella tularensis and Bacillus anthracis in Liquid Culture

We conducted comprehensive (untargeted) metabolic profiling of volatile organic compounds (VOCs) emitted in culture by bacterial taxa Francisella tularensis (F. tularensis) subspecies novicida and Bacillus anthracis (B. anthracis) Sterne, surrogates for potential bacterial bioterrorism agents, as well as selective measurements of VOCs from their fully virulent counterparts, F. tularensis subspecies tularensis strain SCHU S4 and B. anthracis Ames. F. tularensis and B. anthracis were grown in liquid broth for time periods that covered logarithmic growth, stationary, and decline phases. VOCs emitted over the course of the growth phases were collected from the headspace above the cultures using solid phase microextraction (SPME) and were analyzed using gas chromatography-mass spectrometry (GC-MS). We developed criteria for distinguishing VOCs originating from bacteria versus background VOCs (originating from growth media only controls or sampling devices). Analyses of collected VOCs revealed methyl ketones, alcohols, esters, carboxylic acids, and nitrogen- and sulfur-containing compounds that were present in the bacterial cultures and absent (or present at only low abundance) in control samples indicating that these compounds originated from the bacteria. Distinct VOC profiles where observed for F. tularensis when compared with B. anthracis while the observed profiles of each of the two F. tularensis and B. anthracis strains exhibited some similarities. Furthermore, the relative abundance of VOCs was influenced by bacterial growth phase. These data illustrate the potential for VOC profiles to distinguish pathogens at the genus and species-level and to discriminate bacterial growth phases. The determination of VOC profiles lays the groundwork for non-invasive probes of bacterial metabolism and offers prospects for detection of microbe-specific VOC biomarkers from two potential biowarfare agents.

59 BASIC BIOLOGICAL SCIENCES↗

The influence of sampling rate on the dynamics and control of aeronautical systems

It is shown in the design of aeronautical control systems that sampling rate variations give rise to migrations of the discrete eigenvalues for both the plant and the controllers. In general, these migrations tend to degrade simulation fidelity and the overall performance of Ultrareliable Fault Tolerant Control Systems (UFTCS). These systems consist of a redundant asynchronous network of microprocessors which use sensor information to generate the servo commands that drive actuators, thrust linkages, etc. A change in the sampling period of a single microprocessor will, in addition to causing an eigenvalue shift, alter the magnitude of the servo command issued by the controller. The influence of these changes and the effect of initial conditions and skew are considered.

Howard, J. C.↗

Analysis of Tank 38H (HTF-38-20-7, -8) and tank 43H (HTF-43-20-9, -10) samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample decreased significantly from the previous surface sample. The Tank 38H sub-surface sample shows only small changes in concentration for most major species in the solution from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank. The Tank 38H sub-surface sample contained a small amount of sludge solids (<1 wt%).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-20-62, -63) and Tank 43H (HTF-43-20-60, -61) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample increased from the previous surface sample. The Tank 38H sub-surface sample shows only small changes in concentration for most major species in the solution from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank. The Tank 38H surface and sub-surface samples both contained a small amount of sludge solids (<1 wt%). The Tank 43H surface and sub-surface samples are slightly more dilute than the previous samples. The Tank 43H sub-surface sample exhibits a composition more concentrated than the surface sample indicating some stratification within the tank. The Tank 38H surface and sub-surface sample both show large increases in the concentrations of uranium and plutonium likely due to the presence of sludge solids in both samples. (Note: the samples were digested and analyzed without filtration.) The total uranium concentrations of the two Tank 43H samples are similar to the previous sample results. The plutonium concentration in both Tank 43H samples appear to have decreased from the previous samples; however, the surface sample concentrations are close to the detection limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-20-103, -104) and Tank 43H (HTF-43-20-105, -106) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample decreased from the previous surface sample. The Tank 38H sub-surface sample shows only minor changes in concentration for soluble species in the solution (e.g., Na, Al, Cs-137) but a large drop in concentrations for species typically associated with sludge solids (e.g., U, Pu, Fe, Si) likely because of a decrease in sludge solids from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-21-95, -96) and Tank 43H (HTF-43-21-97, -98) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample increased from the previous surface sample. The Tank 38H sub-surface sample shows only minor changes in concentration for soluble species in the solution (e.g., Na, Al, Cs-137) relative to the previous sample, but a small decrease in concentrations for species typically associated with sludge solids (e.g., U, Pu, Fe, Si) likely because of a decrease in sludge solids from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-22-31, -32) and Tank 43H (HTF-43-22-33, -34) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Tank 38H sub-surface sample contains less sludge solids than the previous sample based on visual appearance. The small differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate only minimal stratification of solution species within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-22-91, -92) and Tank 43H (HTF-43-22-93, -94) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased slightly from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Tank 38H sub-surface sample contains more sludge solids than the previous sample based on visual appearance. The small differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate only minimal stratification of solution species within the tank. The Tank 43H surface and sub-surface samples are similar in composition to the previous samples. The similar solution compositions measured in the Tank 43H surface and sub-surface samples indicate a minimal stratification within the tank. The total uranium and plutonium in the current Tank 38H surface sample remains similar to the previous analysis. The Tank 38H sub-surface sample shows an increase in uranium and plutonium concentrations compared to the previous sample likely because of an increase in sludge solids in the current sample. The total uranium concentration in the two Tank 43H samples is essentially unchanged from previous sample results. The plutonium concentration in the Tank 43H surface sample is similar to the previous sample results while the plutonium in the Tank 43H sub-surface sample increased relative to the previous analysis. The sum of the major cations versus the sum of the major anions shows a difference of <10% for both samples from Tank 38H and for both samples from Tank 43H providing an indication of good data quality for the non-radioactive analytes in the samples. The silicon concentrations measured in the Tank 38H sub-surface sample increased compared with the previous sample results likely due to the presence of more sludge solids in the current sample. The Tank 38H surface sample silicon concentrations is similar to the previous sample results. The Tank 43H surface and sub-surface sample silicon concentrations both increased compared to the previous sample results. The samples analyzed from Tanks 38H and 43H show silicon concentrations ranging from 61.5 to 97.3 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38h (HTF-38-23-19, -20) and Tank 43H (HTF-43-23-21, -22) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample decreased significantly from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Thank 38H sub-surface sample contains visible sludge solids similar to the previous sample, i.e., less than 1%, based on visual appearance. The significant differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species between these two locations within the tank. Savannah River Mission Completion personnel indicate that ~ 150,000 gallons of Tank 22 supernate were received in Tank 38H since its last analysis during which time the 2H evaporator was not operated, so the observed stratification is expected. The Tank 43H surface and sub-surface samples are similar in composition to the previous samples. The similar solution compositions measured in the Tank 43H surface and sub-surface samples indicate a minimal stratification within the tank. The total uranium and plutonium in the current Tank 38H surface sample remains similar to the previous analysis. The Tank 38H sub-surface sample shows an increase in uranium and plutonium concentrations compared to the previous sample likely because of an increase in sludge solids in the current sample. The total uranium concentration in the Tank 43H surface sample is similar to the previous sample results while the plutonium in the Tank 43H sub-surface sample increased relative to the previous analysis. The sum of the major cations versus the sum of the major anions shows a difference of <10% for both samples from Tank 38H sub-surface sample (174 mg/L) increased compared with the previous sample. The Tank 38H surface sample silicon concentrations (27.5 mg/L) is one-half of the previous sample results. The Tank 43H surface sample silicon concentrations compared to the previous sample results indicate Si in the concentration range of 60 to 83 mg/L. Thus, these current samples analyzed from Tanks 38H and 43H show overall silicon concentrations ranging from 27.5 to 174 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing to determine the vacuum-ultraviolet degradation rate of thermal control coatings

Samples of S-13G that had been exposed to the salt air environment of Cape Kennedy, Florida were irradiated with simulated solar ultraviolet radiation after various cleaning treatments. In both of the the tests conducted two of the salt air exposed samples were not cleaned, two were lightly cleaned with water and detergent (i.e. rinsed), and two were vigorously scrubbed. Several other white thermal control coatings were also irradiated. The solar absorptance values of these coatings before and as a result of the ultraviolet irradiation are reported for exposure levels up to approximately 2000 ESH.

Gilligan, J. E.↗

Numerical operator method

Algebraic solutions of difference equations - stability of sampled-data control systems - numerical method for determining transients in electric systems excited by complex signals

ELECTRIC NETWORK↗