Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contact Forces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Hypothetical Efficiency of Electrical to Mechanical Energy Transfer during Individual Stochastic Molecular Switching Events

There are now many examples of single molecule rotors, motors and switches in the literature that, when driven by photons, electrons or chemical reactions, exhibit well defined motions. As a step towards using these single molecule devices to perform useful functions one must understand how they interact with their environment and quantify their ability to perform work on it. Using a single molecule rotary switch we examine the transfer of electrical energy, delivered via electron tunneling, to mechanical motion and measure the forces the switch experiences with a non-contact q-plus atomic force microscope. Action spectra reveal that the molecular switch has two stable states and can be excited resonantly between them at a bias of 100 mV via a one-electron inelastic tunneling process which corresponds to an energy input of 16 zepto Joules. Furthermore, while the electrically induced switching events are stochastic and no net work is to done on the cantilever, by measuring the forces between the molecular switch and the AFM cantilever we can derive the maximum hypothetical work the switch could perform during a single switching event which is ~55 meV, equal to 8.9 zepto Joules which translates to a hypothetical efficiency ~55% per individual inelastic tunneling electron induced switching event. When co considering the total electrical energy input this drops to 1x10 -7 % due to elastic tunneling events that dominate the tunneling current. However, this approach constitutes a general method for quantifying and comparing the energy input and output of molecularmechanical devices.

36 MATERIALS SCIENCE↗

Analysis of Pull Force Test Results for Crimped Connections

Crimped electrical contacts are reliable when strict process controls are followed during manufacturing and accompanied by continuous process verification through pull force testing. Cable and wire harness assemblies’ standards are developed and refined over time to provide the minimum pull force that a crimp contact must meet before it breaks from the wire. However, in practice the failures occur at a much higher tensile strength than the minimum required. The first section of this paper reviewed 780 pull force test results provided by NASA Centers that were collected and analyzed to determine how the data compare to NASA’s pre-existing requirements from the cable/harness standards NASA-STD-8739.4 and IPC/WHMA-A-620B-S. The measured tensile strength of most of the contact/conductor pairs (i.e., Contact/Wires or C/W) exceeded the minimum pull force values of NASA-STD-8739.4 and IPC/WHMA-A-620 standards by at least 100%. The C/W pair samples’ tensile strength values followed a normal distribution with an average tensile strength value that was at least 182% of the minimum requirement, and all the samples analyzed passed the pull force testing. In addition, the 95% confidence interval of the average tensile strength distributions for several C/W pairs was determined and plotted as error bars to show that the C/W pairs will meet and surpass the requirements. The frequency of pull force testing can be problematic for projects because of the cost and availability of spare contacts for the destructive test. It is possible to reduce the frequency of pull force testing if at the beginning of the production run, the conditions of the crimp tool and materials are verified, and the settings of the tool remain unchanged throughout the process. However, the project needs to understand and evaluate the impact to risk from reducing the frequency of testing prior to implementing process changes.

Alejandra Constante↗

Analysis of Pull Force Test Results for Crimped Connections

Crimped electrical contacts are reliable when strict process controls are followed during manufacturing and accompanied by continuous process verification through pull force testing. Cable and wire harness assemblies’ standards are developed and refined over time to provide the minimum pull force that a crimp contact must meet before it breaks from the wire. However, in practice the failures occur at a much higher tensile strength than the minimum required. The first section of this paper reviewed 780 pull force test results provided by NASA Centers were collected and analyzed to determine how the data compares to NASA’s pre-existing requirements from the cable/harness standards NASA-STD-8739.4 and IPC/WHMA-A-620B-S. The measured tensile strength of most of the contact/conductor pairs (i.e. Contact/Wires or C/W) exceeded the minimum pull force values of NASA-STD-8739.4 and IPC/WHMA-A-620 standards by at least 100 %. The tensile strength samples of the C/W pairs values followed a normal distribution with an average tensile strength value that was at least 182 % of the minimum requirement, and all the samples analyzed passed the pull force testing. In addition, the 95 % confidence interval of the average tensile strength distributions for several C/W pairs was determined and plotted as error bars to show that there is good likelihood to observe C/W pair normal distribution with a 95 % confidence interval that will meet and surpass the standard requirements. The frequency of pull force testing can be problematic for projects because of the cost and availability of spare contacts for the destructive test. It could be possible to reduce the frequency of pull force testing if at the beginning of the production run, the conditions of the crimp tool and materials are verified, and the settings of the tool remain unchanged throughout the process. However, the project must evaluate the impact to risk from reducing the frequency of testing.

Crimped connections↗

Processing of hollow sections

A system and method provide a material with uniform micro-structure. In an embodiment, an equal channel angular extrusion system includes an interior mandrel. The interior mandrel includes an expanding shear material section and a contracting shear material section. In addition, the system includes a material. The material is disposed about a portion of the interior mandrel. Moreover, the system includes a pressure application device. The pressure application device applies pressure to the material to force the material to contact the expanding shear material section to provide an expanded post-shear material section. Pressure from the pressure application device applies pressure to the material to force the expanded post-shear material section to contact the contracting shear material section to provide a contracted shear material section.

42 ENGINEERING↗

Processing of hollow sections

A system and method provide a material with uniform micro-structure. In an embodiment, an equal channel angular extrusion system includes an interior mandrel. The interior mandrel includes an expanding shear material section and a contracting shear material section. In addition, the system includes a material. The material is disposed about a portion of the interior mandrel. Moreover, the system includes a pressure application device. The pressure application device applies pressure to the material to force the material to contact the expanding shear material section to provide an expanded post-shear material section. Pressure from the pressure application device applies pressure to the material to force the expanded post-shear material section to contact the contracting shear material section to provide a contracted shear material section.

Barber, Robert E.↗

Evaluation of the electrical contact area in contact-mode scanning probe microscopy

The tunneling current through an atomic force microscopy (AFM) tip is used to evaluate the effective electrical contact area, which exists between tip and sample in contact-AFM electrical measurements. A simple procedure for the evaluation of the effective electrical contact area is described using conductive atomic force microscopy (C-AFM) in combination with a thin dielectric. We characterize the electrical contact area for coated metal and doped-diamond tips operated at low force (<200 nN) in contact mode. In both cases, we observe that only a small fraction (<10 nm{sup 2}) of the physical contact (∼100 nm{sup 2}) is effectively contributing to the transport phenomena. Assuming this reduced area is confined to the central area of the physical contact, these results explain the sub-10 nm electrical resolution observed in C-AFM measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Friction Anisotropy: A unique and intrinsic property of decagonal quasicrystals

We show that friction anisotropy is an intrinsic property of the atomic structure of Al-Ni-Co decagonal quasicrystals and not only of clean and well-ordered surfaces that can be prepared in vacuum [J.Y. Park et al., Science (2005)]. Friction anisotropy is manifested both in nanometer size contacts obtained with sharp atomic force microscope (AFM) tips as well as in macroscopic contacts produced in pin-on-disc tribometers. We show that the friction anisotropy, which is not observed when an amorphous oxide film covers the surface, is recovered when the film is removed due to wear. Equally important is the loss of the friction anisotropy when the quasicrystalline order is destroyed due to cumulative wear. These results reveal the intimate connection between the mechanical properties of these materials and their peculiar atomic structure.

36 MATERIALS SCIENCE↗

Motor adaptation to Coriolis force perturbations of reaching movements: endpoint but not trajectory adaptation transfers to the nonexposed arm

1. Reaching movements made in a rotating room generate Coriolis forces that are directly proportional to the cross product of the room's angular velocity and the arm's linear velocity. Such Coriolis forces are inertial forces not involving mechanical contact with the arm. 2. We measured the trajectories of arm movements made in darkness to a visual target that was extinguished at the onset of each reach. Prerotation subjects pointed with both the right and left arms in alternating sets of eight movements. During rotation at 10 rpm, the subjects reached only with the right arm. Postrotation, the subjects pointed with the left and right arms, starting with the left, in alternating sets of eight movements. 3. The initial perrotary reaching movements of the right arm were highly deviated both in movement path and endpoint relative to the prerotation reaches of the right arm. With additional movements, subjects rapidly regained straight movement paths and accurate endpoints despite the absence of visual or tactile feedback about reaching accuracy. The initial postrotation reaches of the left arm followed straight paths to the wrong endpoint. The initial postrotation reaches of the right arm had paths with mirror image curvature to the initial perrotation reaches of the right arm but went to the correct endpoint. 4. These observations are inconsistent with current equilibrium point models of movement control. Such theories predict accurate reaches under our experimental conditions. Our observations further show independent implementation of movement and posture, as evidenced by transfer of endpoint adaptation to the nonexposed arm without transfer of path adaptation. Endpoint control may occur at a relatively central stage that represents general constraints such as gravitoinertial force background or egocentric direction relative to both arms, and control of path may occur at a more peripheral stage that represents moments of inertia and muscle dynamics unique to each limb. 5. Endpoint and path adaptation occur despite the absence both of mechanical contact cues about the perturbing force and visual or tactile cues about movement accuracy. These findings point to the importance of muscle spindle signals, monitoring of motor commands, and possibly joint and tendon receptors in a detailed trajectory monitoring process. Muscle spindle primary and secondary afferent signals may differentially influence adaptation of movement shape and endpoint, respectively.

Non-NASA Center↗

Microwave emission from lead zirconate titanate induced by impulsive mechanical load

This paper focuses on microwave emission from Lead zirconate titanate Pb [Zr{sub x}Ti{sub 1−x}] O{sub 3} (PZT) induced by mechanical stressing. The mechanical stress was initiated by impact of a sharp tungsten indenter on the upper surface of PZT ceramic. The sequences of microwave and current impulses, which flew from indenter to electric ground, were detected simultaneously. The voltage between the upper and lower surface of ceramic was measured to obtain the behavior of mechanical force acting on ceramic during the impact. It was found that the amplitude, form, and frequency of measured microwave impulses were different by compression and restitution phase of impact. Two different mechanisms of electron emission, responsible for microwave impulse generation, were proposed based on the dissimilar impulse behavior. The field emission from tungsten indenter is dominant during compression, whereas ferroemission dominates during restitution phase. Indeed, it was observed that the direction of the current flow, i.e., sign of current impulses is changed by transitions from compression to restitution phase of impact. The observed dissimilar behavior of microwave impulses, caused by increasing and decreasing applied force, can be used to calculate the contact time and behavior of mechanical force during mechanical impact on ceramic surface. It is shown that the generation of microwave impulses exhibits high reproducibility, impulse intensity, a low damping factor, and high mechanical failure resistance. Based on these microwave emission properties of PZT, the development of new type of stress sensor with spatial resolution of few microns becomes possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stress evaluations under rolling/sliding contacts

The state of stress beneath traction drive type of contacts were analyzed. Computing stresses and stress reversals on various planes for points beneath the surface were examined. The effect of tangential and axial friction under gross slip conditions is evaluated with the models. Evaluations were performed on an RC (rolling contact) tester configuration and it is indicated that the classical fatigue stresses are not altered by friction forces typical of lubricated contact. Higher values of friction can result in surface shear reversal that exceeds the stresses at the depth of maximum shear reversal under rolling contact.

Kannel, J. W.↗

The Micromechanics of the Moving Contact Line

The proposed research is divided into three components concerned with molecular structure, molecular orientation, and continuum averages of discrete systems. In the experimental program, we propose exploring how changes in interfacial molecular structure generate contact line motion. Rather than rely on the electrostatic and electrokinetic fields arising from the molecules themselves, we augment their interactions by an imposed field at the solid/liquid interface. By controling the field, we can manipulate the molecular structure at the solid/liquid interface. In response to controlled changes in molecular structure, we observe the resultant contact line motion. In the analytical portion of the proposed research we seek to formulate a system of equations governing fluid motion which accounts for the orientation of fluid molecules. In preliminary work, we have focused on describing how molecular orientation affects the forces generated at the moving contact line. Ideally, as assumed above, the discrete behavior of molecules can be averaged into a continuum theory. In the numerical portion of the proposed research, we inquire whether the contact line region is, in fact, large enough to possess a well-defined average. Additionally, we ask what types of behavior distinguish discrete systems from continuum systems. Might the smallness of the contact line region, in itself, lead to behavior different from that in the bulk? Taken together, our proposed research seeks to identify and accurately account for some of the molecular dynamics of the moving contact line, and attempts to formulate a description from which one can compute the forces at the moving contact line.

Han, Minsub↗

Torsional force microscopy of van der Waals moirés and atomic lattices

In a stack of atomically thin van der Waals layers, introducing interlayer twist creates a moiré superlattice whose period is a function of twist angle. Changes in that twist angle of even hundredths of a degree can dramatically transform the system’s electronic properties. Setting a precise and uniform twist angle for a stack remains difficult; hence, determining that twist angle and mapping its spatial variation is very important. Techniques have emerged to do this by imaging the moiré, but most of these require sophisticated infrastructure, time-consuming sample preparation beyond stack synthesis, or both. In this work, we show that torsional force microscopy (TFM), a scanning probe technique sensitive to dynamic friction, can reveal surface and shallow subsurface structure of van der Waals stacks on multiple length scales: the moirés formed between bi-layers of graphene and between graphene and hexagonal boron nitride (hBN) and also the atomic crystal lattices of graphene and hBN. In TFM, torsional motion of an Atomic Force Microscope (AFM) cantilever is monitored as it is actively driven at a torsional resonance while a feedback loop maintains contact at a set force with the sample surface. TFM works at room temperature in air, with no need for an electrical bias between the tip and the sample, making it applicable to a wide array of samples. It should enable determination of precise structural information including twist angles and strain in moiré superlattices and crystallographic orientation of van der Waals flakes to support predictable moiré heterostructure fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the origin of Amonton's friction law

Amonton s law states that the sliding friction force increases linearly with the load. We show that this result is expected for stiff enough solids, even when the adhesional interaction between the solids is included in the analysis. As a function of the magnitude of the elastic modulus E, one can distinguish between three regions: (a) for E > E2, the area of real contact (and the friction force) depends linearly on the load, (b) for E1 < E < E2, the area of real contact depends nonlinearly on the load but vanishes for zero load, and (c) for E < E1 the area of real contact depends nonlinearly on the load and is non-vanishing at zero load. In this last case a finite pull-off force is necessary in order to separate the solids. Based on molecular dynamics calculations, we also discuss the pressure dependence of the frictional shear stress for polymers. We show that the frictional shear stress is independent of the normal pressure p0 as long as p0 is much smaller than the adhesional pressure pad, which depends on the atomic corrugation of the solid surfaces in the sliding interface. Finally, we discuss the origin of why the contact area between a soft elastic solid (e.g. rubber) and a flat substrate decreases from the JKR (adhesive contact) limit at zero or small sliding velocities, to the Hertz (non-adhesive) limit at high sliding velocities.

Persson, Bo Nils J↗

Pebble Bed Reactor Dust Production Model

The operation of pebble bed reactors, including fuel circulation, can generate graphite dust, which in turn could be a concern for internal components; and to the near field in the remote event of a break in the coolant circuits. The design of the reactor system must, therefore, take the dust into account and the operation must include contingencies for dust removal and for mitigation of potential releases. Such planning requires a proper assessment of the dust inventory. This paper presents a predictive model of dust generation in an operating pebble bed with recirculating fuel. In this preliminary work the production model is based on the use of the assumption of proportionality between the dust production and the normal force and distance traveled. The model developed in this work uses the slip distances and the inter-pebble forces computed by the authors’ PEBBLES. The code, based on the discrete element method, simulates the relevant static and kinetic friction interactions between the pebbles as well as the recirculation of the pebbles through the reactor vessel. The interaction between pebbles and walls of the reactor vat is treated using the same approach. The amount of dust produced is proportional to the wear coefficient for adhesive wear (taken from literature) and to the slip volume, the product of the contact area and the slip distance. The paper will compare the predicted volume with the measured production rates. The simulation tallies the dust production based on the location of creation. Two peak production zones from intra pebble forces are predicted within the bed. The first zone is located near the pebble inlet chute due to the speed of the dropping pebbles. The second peak zone occurs lower in the reactor with increased pebble contact force due to the weight of supported pebbles. This paper presents the first use of a Discrete Element Method simulation of pebble bed dust production.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On the metal/ZnO contacts in a sliding-bending piezoelectric nanogenerator

We carry out molecular dynamics (MD) simulations and analyze the piezoelectric and mechanical properties of a ZnO nanowire (NW) under mechanical bending in a sliding-bending piezoelectric nanogenerator. The computational model contains a vertically aligned ZnO NW along the [0001] direction and a Pt (111) metal tip. MD simulations are performed to mimic the interfacial sliding dynamics of an atomic force microscope (AFM) metal tip sliding over a ZnO NW. Ionic charges for Zn and O in the ZnO NW are used to calculate the piezoelectric potential distributions in a grid-point matrix. Simulation results reveal the very detailed distributions of the piezoelectric potential within the ZnO NW, which are different from the continuum field theory predictions. The very similar variations of the lateral friction and contact forces versus the sliding distance of the AFM metal tip over the ZnO NW during repeated forward-backward sliding suggest that the metal/ZnO contact is robust. Moreover, the substantial contact area at the metal/ZnO interface suggests that a Schottky contact should be established at the interface, which needs further investigations.

Chemistry↗

High-Performance Modeling and Simulation of Anchoring in Granular Media for NEO Applications

NASA is interested in designing a spacecraft capable of visiting a near-Earth object (NEO), performing experiments, and then returning safely. Certain periods of this mission would require the spacecraft to remain stationary relative to the NEO, in an environment characterized by very low gravity levels; such situations require an anchoring mechanism that is compact, easy to deploy, and upon mission completion, easy to remove. The design philosophy used in this task relies on the simulation capability of a high-performance multibody dynamics physics engine. On Earth, it is difficult to create low-gravity conditions, and testing in low-gravity environments, whether artificial or in space, can be costly and very difficult to achieve. Through simulation, the effect of gravity can be controlled with great accuracy, making it ideally suited to analyze the problem at hand. Using Chrono::Engine, a simulation pack age capable of utilizing massively parallel Graphic Processing Unit (GPU) hardware, several validation experiments were performed. Modeling of the regolith interaction has been carried out, after which the anchor penetration tests were performed and analyzed. The regolith was modeled by a granular medium composed of very large numbers of convex three-dimensional rigid bodies, subject to microgravity levels and interacting with each other with contact, friction, and cohesional forces. The multibody dynamics simulation approach used for simulating anchors penetrating a soil uses a differential variational inequality (DVI) methodology to solve the contact problem posed as a linear complementarity method (LCP). Implemented within a GPU processing environment, collision detection is greatly accelerated compared to traditional CPU (central processing unit)- based collision detection. Hence, systems of millions of particles interacting with complex dynamic systems can be efficiently analyzed, and design recommendations can be made in a much shorter time. The figure shows an example of this capability where the Brazil Nut problem is simulated: as the container full of granular material is vibrated, the large ball slowly moves upwards. This capability was expanded to account for anchors of different shapes and penetration velocities, interacting with granular soils.

Quadrelli, Marco B.↗

Fabricating Ohmic contact on Nb-doped SrTiO{sub 3} surface in nanoscale

Fabricating reliable nano-Ohmic contact on wide gap semiconductors is an important yet difficult step in oxide nanoelectronics. We fabricated Ohmic contact on the n-type wide gap oxide Nb-doped SrTiO{sub 3} in nanoscale by mechanically scratching the surface using an atomic force microscopy tip. Although contacted to high work function metal, the scratched area exhibits nearly linear IV behavior with low contact resistance, which maintains for hours in vacuum. In contrast, the unscratched area shows Fowler–Nordheim tunneling dominated Schottky rectifying behavior with high contact resistance. It was found that the Ohmic conductivity in the scratched area was drastically suppressed by oxygen gas indicating the oxygen vacancy origin of the Ohmic behavior. The surface oxygen vacancy induced barrier width reduction was proposed to explain the phenomena. The nanoscale approach is also applicable to macroscopic devices and has potential application in all-oxide devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Skylab M551 Metals Melting Experiment

The objectives of the M551 Metals Melting Experiment are to (a) study behavior of molten metal, (b) characterize metals melted and solidified in the low gravity space environment compared to one-gravity of earth, and (c) determine feasibility of joining metals in space. The experiment used the electron beam (EB) and chamber of the M512 apparatus to make a dwell puddle and a melt in a rotating disc of varying thickness. Hence, the EB performed cut-through, full and partial penetration melts, in addition to a re-solidified button. The three disc materials were aluminum 2219-T87, 304 stainless steel and pure tantalum to provide a wide range of density and melting conditions. Observations to date include (a) the proof that EB welding, cutting and melting can be done successfully in low gravity. Earlier, some welding authorities had postulated that without gravity the EB would force the molten puddle out of contact. However, the experiment proved that surface tension forces predominate. (b) From the view-point of cast-solidification, small, equiaxed grains in Skylab specimens compared to large, elongated grains in ground-based specimens were observed. The former are thought to be associated with constitutional supercooling and nucleation where the latter are associated with dendritic solidification. In further support of the more equiaxed grain growth in Skylab, symmetric sub-grain patterns were frequently observed where there was much less symmetry in ground-based specimens. Further work is being done to explain the differences in solidification.

E C Mckannan↗