Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configurable lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Wafer-scale two-dimensional Au-TiO{sub 2} bilayer films for photocatalytic degradation of Palmitic acid under UV and visible light illumination

Highlights: • Successful wafer-scale atomic layer deposition of 2D Au-TiO{sub 2} bilayer photocatalyst films. • The efficient degradation of fatty acid by tailoring 2D TiO{sub 2} films under UV and visible light illumination. • Improved visible light photocatalytic activity and photocurrent density of 2D Au-TiO{sub 2} bilayer films. • Comparable photocatalytic performance of ultra-thin 2D TiO{sub 2} and thick TiO{sub 2} films under UV light illumination. - Abstract: Bilayer Au-TiO{sub 2} configuration with two-dimensional (2D) TiO{sub 2} films enabled sensible improvement in photocatalytic degradation of Palmitic Acid (PA) and also the enhancement of current density under visible light illumination. The improved visible light photocatalytic and photocurrent properties were attained when 35 nm thick 2D TiO{sub 2} film was developed by atomic layer deposition (ALD) on Si/SiO{sub 2}-Au substrate. The Au-TiO{sub 2} bilayer demonstrated the improved photocatalytic and photovoltaic performances compared with those TiO{sub 2} films developed on Si/SiO{sub 2} bare substrate. These improvements can be attributed to the plasmonic effects of Au film acting as antenna for visible light and also serving as hole acceptor during photocatalysis process. The proposed mechanisms for enhanced visible light performance of bilayer films are hot electron injection and the formation of hot spots at Au-TiO{sub 2} interface which contributed to the electron injection to conduction band of TiO{sub 2} or facilitated the separation of generated electron-hole pairs at Au-TiO{sub 2} Schottky junction.

36 MATERIALS SCIENCE↗

Upgrade to the SHARP EUV mask microscope

© 2019 SPIE. The Sharp High-NA Actinic Reticle review Project (SHARP) is a synchrotron-based, extreme ultraviolet (EUV) microscope dedicated to photomask research. A potential upgrade to the SHARP microscope is presented. The upgrade includes changing the light path in the instrument from its current off-Axis configuration to an on-Axis configuration. This change allows for an increased working distance of 2.5 mm or more. A central obscuration, added to the zoneplate aperture, blocks stray light from reaching the central part of the image, thus improving the image contrast. The imaging performance of the two configurations is evaluated by means of ray tracing.

Benk, M↗

Parallel Quantum-Enhanced Sensing

Quantum metrology takes advantage of quantum correlations to enhance the sensitivity of sensors and measurement techniques beyond their fundamental classical limit, given by the shot-noise limit. The use of both temporal and spatial correlations present in quantum states of light can extend quantum-enhanced sensing to a parallel configuration that can simultaneously probe an array of sensors or independently measure multiple parameters. To this end, we use multispatial-mode bright twin beams of light, which are characterized by independent quantum-correlated spatial subregions in addition to quantum temporal correlations, to probe a four-sensor quadrant plasmonic array. We show that it is possible to independently and simultaneously measure local changes in refractive index for all four sensors with a quantum enhancement in sensitivity in the range of 22% to 24% over the corresponding classical configuration. Finally, these results provide a first step toward highly parallel spatially resolved quantum-enhanced sensing techniques and pave the way toward more complex quantum sensing and quantum imaging platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a Polyvinyl Toluene Neutron Counter Array

The purpose of this article is to simulate the performance of a neutron detector array for empirical configuration optimization and preliminary algorithm evaluation. Utilizing a compact array of borated Polyvinyl Toluene light pipes and Photomultiplier Tubes, pulse shape analysis, standard spectral histogramming, and multiplicity counting can enable neutron measurements for multiple applications. Results demonstrate that analysis with Monte Carlo N-Particle (MCNP) can be used to obtain a better understanding of field measurement results and aid in algorithm development for unfolding in conjunction with detector optimization. Use of a handheld neutron spectrometer has promise of widespread applicability. By correlating MCNP results with empirical measurements, substantial confidence can be placed on predicting detector response to sufficiently similar spectral sources under alternate experimental configurations. In addition, use of the detector has substantial promise for operational health physics applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of early events in the photoactivation of Myxobacterial phytochrome using time-resolved serial femtosecond crystallography

Myxobacteria are non-photosynthetic, soil-dwelling bacteria distinguished by a multicellular stage in their life cycle known as fruiting bodies that are stimulated by light. Myxobacterial phytochromes are candidates for the perception of red-light. The mechanism how light is perceived and converted to a physiological response is unknown. Here, time-resolved serial femtosecond crystallographic (TR-SFX) experiments were conducted on microcrystals of the photosensory core module of the Stigmatella aurantiaca bacteriophytochrome 2 (SaBphP2). Initial events of the Z to E isomerization reaction of the covalently bound, open-chain tetrapyrrole biliverdin (BV) chromophore were determined. At 3 ps after light activation, the BV ring-D assumes a configuration needed for the isomerization. At 100 ps, a mixture of BV in the Z or E configuration is observed in subunit A, while in the other subunit the chromophore remains in the Z configuration. In conjunction with prior results, these structures reveal the molecular mechanism of phytochrome activation in the photomorphogenesis of the myxobacteria and provide the molecular foundation for physiological responses to red light in other bacteria.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Space-time crystals from particle-like topological solitons

Time crystals are unexpected states of matter that spontaneously break time-translation symmetry either in a discrete or continuous manner. However, spatially mesoscale space-time crystals that break both space and time symmetries have not been reported. Here we report a continuous space-time crystal in a nematic liquid crystal driven by ambient-power, constant-intensity unstructured light. Our numerically constructed four-dimensional configurations exhibit good agreement with these experimental findings. Although meeting the established criteria to identify time-crystalline order, both experiments and computer simulations reveal a space-time crystallization phase formed by particle-like topological solitons. The robustness against temporal perturbations and spatiotemporal dislocations shows the stability and rigidity of the studied space-time crystals, which relates to their locally topological nature and many-body interactions between emergent spontaneously twisted, particle-like solitonic building blocks. Their potential technological utility includes optical devices, photonic space-time crystal generators, telecommunications and anti-counterfeiting designs, among others.

Liquid crystals↗

Superior spatial resolution in confocal X-ray techniques using collimating channel array optics: elemental mapping and speciation in archaeological human bone

Confocal X-ray fluorescence imaging (CXFI) and confocal X-ray absorption spectroscopy (CXAS) respectively enable the study of three dimensionally resolved localization and speciation of elements. Applied to a thick sample, essentially any volume element of interest within the X-ray fluorescence escape depth can be examined without the need for physical thin sectioning. To date, X-ray confocal detection generally has employed a polycapillary optic in front of the detector to collect fluorescence from the probe volume formed at the intersection of its focus with the incident microfocus beam. This work demonstrates the capability of a novel Collimating Channel Array (CCA) optic in providing an improved and essentially energy independent depth resolution approaching 2 μm. By presenting a comparison of elemental maps of archaeological bone collected without confocal detection, and with polycapillary- and CCA-based confocal detection, this study highlights the strengths and limitations of each mode. Unlike the polycapillary, the CCA shows similar spatial resolution in maps for both low (Ca) and high (Pb and Sr) energy X-ray fluorescence, thus illustrating the energy independent nature of the CCA optic resolution. While superior spatial resolution is demonstrated for all of these elements, the most significant improvement is observed for Ca, demonstrating the advantage of employing the CCA optic in examining light elements. In addition to CXFI, this configuration also enables the collection of Pb L3 CXAS data from micro-volumes with dimensions comparable to bone microstructures of interest. Our CXAS result, which represents the first CCA-based biological CXAS, demonstrates the ability of CCA optics to collect site specific spectroscopic information. The demonstrated combination of site-specific elemental localization and speciation data will be useful in diverse fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation driven Hohlraum using 2 ω for ICF implosions at the NIF

Radiation flux symmetry in laser-irradiated Hohlraum environments is difficult to model and control and relies on the details of plasma evolution and laser energy deposition in the harsh plasma-filled Hohlraum over the duration of the laser pulse. This study presents a conceptual design and assesses the feasibility of using lasers to create a radiation drive where the implosion symmetry relies mainly on radiation transport. In this design, the ends of a capsule containing Hohlraum are irradiated by drive laser beams that are shielded from the view of the capsule. This configuration enables the use of frequency doubled light that has a higher power and energy threshold for the current capability of NIF, up to 670 TW and ∼3.5 MJ. We estimate, using VISRAD benchmarked against HYDRA calculations, that the same drive conditions that are currently being achieved in hybridE experiments at the NIF 270–290 at the equator can be reached in this new geometry and large 6.4 mm diameter Hohlraums. The radiation drive asymmetries in this design can be mitigated by shimming the capsule ablator thickness or through tailoring the shape of the shielding to the laser spots.

Kritcher, A. L. (ORCID:0000000296941088)↗

Isotope effects in liquid water via deep potential molecular dynamics

A comprehensive microscopic understanding of ambient liquid water is a major challenge for ab initio simulations as it simultaneously requires an accurate quantum mechanical description of the underlying potential energy surface (PES) as well as extensive sampling of configuration space. Due to the presence of light atoms (e.g. 𝐻 or 𝐷), nuclear quantum fluctuations lead to observable changes in the structural properties of liquid water (e.g. isotope effects), and therefore provide yet another challenge for ab initio approaches. In this work, we demonstrate that the combination of dispersion-inclusive hybrid density functional theory (DFT), the Feynman discretised path-integral (PI) approach, and machine learning (ML) constitutes a versatile ab initio based framework that enables extensive sampling of both thermal and nuclear quantum fluctuations on a quite accurate underlying PES. In particular, we employ the recently developed deep potential molecular dynamics (DPMD) model – a neural-network representation of the ab initio PES – in conjunction with a PI approach based on the generalised Langevin equation (PIGLET) to investigate how isotope effects influence the structural properties of ambient liquid 𝐻⁢2⁢𝑂 and 𝐷⁢2⁢𝑂. Through a detailed analysis of the interference differential cross sections as well as several radial and angular distribution functions, we demonstrate that this approach can furnish a semi-quantitative prediction of these subtle isotope effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GJ 3236: A NEW BRIGHT, VERY LOW MASS ECLIPSING BINARY SYSTEM DISCOVERED BY THE MEARTH OBSERVATORY

We report the detection of eclipses in GJ 3236, a bright (I = 11.6), very low mass binary system with an orbital period of 0.77 days. Analysis of light and radial velocity curves of the system yielded component masses of 0.38 {+-} 0.02 M{sub sun} and 0.28 {+-} 0.02 M{sub sun}. The central values for the stellar radii are larger than the theoretical models predict for these masses, in agreement with the results for existing eclipsing binaries, although the present 5% observational uncertainties limit the significance of the larger radii to approximately 1{sigma}. Degeneracies in the light curve models resulting from the unknown configuration of surface spots on the components of GJ 3236 currently dominate the uncertainties in the radii, and could be reduced by obtaining precise, multiband photometry covering the full orbital period. The system appears to be tidally synchronized and shows signs of high activity levels as expected for such a short orbital period, evidenced by strong H{alpha} emission lines in the spectra of both components. These observations probe an important region of mass-radius parameter space around the predicted transition to fully convective stellar interiors, where there are a limited number of precise measurements available in the literature.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-frequency self-pulsing in single-section quantum-dot laser diodes and its relation to optothermal pulsations

Self-sustained pulsations in the output of an InAs quantum dot laser diode in the MHz range are reported. The characteristics (shape, range, and frequency) are presented for the free-running laser and when optical feedback in the Littrow configuration is applied. Bistability in the light-current characteristics is observed for operating wavelengths smaller than the gain peak, but it is not present for wavelengths above the gain peak and for the free-running laser, except at elevated temperatures. The temporal evolution of the envelopes of the optical spectra is very different for operation below, around, and above the gain peak, which might be related to a change of phase-amplitude coupling across the gain maximum, in agreement with the expectation for a two-level system. The time scale and the bifurcation scenario, supported by an initial blueshift of the emission wavelength of each longitudinal mode in time-resolved optical spectra, suggests that these are optothermal pulsations similar to those reported in quantum well amplifiers [Phys. Rev. E 68, 036209 (2003)]. The mechanism of pulsation seems to be a destabilization of bistable states (due to saturable absorption in the beam wings) by a slow thermal change in the waveguiding properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

$|V_{ub}|$ from $B\to\pi\ell\nu$ decays and (2+1)-flavor lattice QCD

We present a lattice-QCD calculation of the B → πℓν semileptonic form factors and a new determination of the CKM matrix element |V ub |. We use the MILC asqtad (2+1)-flavor lattice configurations at four lattice spacings and light-quark masses down to 1/20 of the physical strange-quark mass. We extrapolate the lattice form factors to the continuum using staggered chiral perturbation theory in the hard-pion and SU(2) limits. We employ a model-independent z parametrization to extrapolate our lattice form factors from large-recoil momentum to the full kinematic range. We introduce a new functional method to propagate information from the chiral-continuum extrapolation to the z expansion. We present our results together with a complete systematic error budget, including a covariance matrix to enable the combination of our form factors with other lattice-QCD and experimental results. To obtain |V ub |, we simultaneously fit the experimental data for the B → πℓν differential decay rate obtained by the BABAR and Belle collaborations together with our lattice form-factor results. We find |V ub |=(3.72±0.16) × 10 –3 , where the error is from the combined fit to lattice plus experiments and includes all sources of uncertainty. Our form-factor results bring the QCD error on |V ub | to the same level as the experimental error. We also provide results for the B → πℓν vector and scalar form factors obtained from the combined lattice and experiment fit, which are more precisely determined than from our lattice-QCD calculation alone. Lastly, these results can be used in other phenomenological applications and to test other approaches to QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiphoton Magnetooptical Trap

We demonstrate a magnetooptical trap (MOT) configuration which employs optical forces due to light scattering between electronically excited states of the atom. With the standard MOT laser beams propagating along the x and y directions, the laser beams along the z direction are at a different wavelength that couples two sets of excited states. We demonstrate efficient cooling and trapping of cesium atoms in a vapor cell and sub-Doppler cooling on both the red and blue sides of the two-photon resonance. The technique demonstrated in this work may have applications in background-free detection of trapped atoms, and in assisting laser cooling and trapping of certain atomic species that require cooling lasers at inconvenient wavelengths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated polarization-free Bragg filters with subwavelength gratings for photonic sensing

We present polarization-free Bragg filters having subwavelength gratings (SWGs) in the lateral cladding region. This Bragg design expands modal fields toward upper cladding, resulting in enhanced light interaction with sensing analytes. Two device configurations are proposed and examined, one with index-matched coupling between transverse electric (TE) and transverse magnetic (TM) modes and the other one with hybrid-mode (HM) coupling. Both configurations introduce a strong coupling between two orthogonal modes (either TE-TM or HM 1 -HM 2 ) and rotate the polarization of the input wave through Bragg reflection. The arrangements of SWGs help to achieve two configurations with different orthogonal modes, while expanding modal profiles toward the upper cladding region. Our proposed SWG-assisted Bragg gratings with polarization independency eliminate the need for a polarization controller and effectively tailor the modal properties, enhancing the potential of integrated photonic sensing applications.

Optics↗

Three-Dimensional Tracking of High-Speed Tumbling Projectiles Using Stroboscopic Imaging

Creating images of high-speed projectiles has been a topic of interest for almost a century. Historically, ballistics ranges have used air-gap flash photography or high-speed video cameras to capture this type of data. Air-gap flash photography provides a single image at each camera station. Using modern high-speed imagers provides accurate data but is cost prohibitive for a long-distance range. This paper presents a camera system capable of capturing the three-dimensional data of high speed projectiles over a long distance. The system uses relatively low-cost cameras which are set up in a stereo vision configuration and uses high-speed strobe lights to create multi exposure images. Each pulse of light captures the position of the projectile as it passes the camera. For each position captured in the image, the three-dimensional position of the projectile is found using triangulation geometry. The linear velocity of the projectile is calculated by combining the position of the projectile with timing data. Two test series were conducted. The first test series compares different cameras and backdrops for the camera system. The second test series captured position data for two different shapes of high-speed tumbling projectiles.

42 ENGINEERING↗