Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Condition Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Monitoring Plan for the Idaho National Laboratory Remote Handled Low Level Waste Disposal Facility

This monitoring plan for Idaho National Laboratory’s Remote-Handled Low Level Waste Disposal Facility was developed to meet the requirements for monitoring low-level waste disposal facilities according to the U.S. Department of Energy (DOE) Order 435.1, “Radioactive Waste Management,” and the guidance provided in the associated technical standard “Disposal Authorization Statement and Tank Closure Documentation” (DOE-STD-5002-2017). The purpose of this monitoring plan is to document a monitoring strategy that includes (1) compliance monitoring activities to demonstrate compliance with regulatory standards/limits and (2) performance monitoring to build confidence the facility is performing as demonstrated in the facility performance assessment (PA) (DOE-ID 2018a), composite analysis (CA) (DOE ID 2012), and CA addendum (DOE-ID 2018b). The de minimus impact to the aquifer predicted by the PA suggests that aquifer compliance monitoring should be augmented with performance monitoring of the drainage course materials and sedimentary interbeds in the vadose zone beneath the facility to provide a more effective means of identifying performance deviations. The monitoring approach delineated in this document was informed by the systems evaluation of natural and engineered facility features presented in the PA, an assessment of aquifer baseline conditions (INL 2017d), the dose analysis conducted in support of the PA and CA, and monitoring data collected during the first four years of facility operations (baseline monitoring phase) (INL 2023b). This plan provides monitoring locations, sampling frequencies, and sampling methods; recommendations for data evaluation; and a description of the monitoring plan implementation. Collected data will be used to demonstrate facility compliance and to identify conditions that are not consistent with the key assumptions made by the PA and CA.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Evaluation of Neutron Detection Technology and Analysis Techniques to Support Fukushima Daiichi Decommissioning [Poster]

Decommissioning efforts and associated fuel debris retrieval from the damaged Units 1-3 require robust methods to monitor and assure subcriticality. These include adequate detection technologies capable to withstand high gamma radiation conditions within the units; as well as analysis methods capable to provide robust signatures to assure agile criticality monitoring in situation where material distribution is changing. This poster presents overview of experimental and analytical efforts focused on evaluation of neutronbased technologies and development of real-time analysis using state-of-the art capabilities available within the 1F Fuel Retrieval and Monitoring Experiments (1FRAME) project.

1FRAME↗

Automated Airborne Pathogen Monitoring for Agriculture (CRADA Final Report)

As part of the Cyclotron Road program, Root Applied Sciences investigated the use of DNA-based assays under field conditions to detect airborne plant pathogens in environmental samples. Robust DNA-based assays are critical for automated monitoring of plant pathogen concentrations in the air using Root’s air samplers. A fully automated air sampler coupled with DNA-based assays capable of operating under field conditions will accelerate the delivery of disease risk alerts based on airborne inoculum loads. Timely and accurate alerts of pathogen loads in the air can help growers manage airborne diseases more precisely, avoiding fungicide applications when there is no threat, and focusing cultural practices in the right areas. This project built upon other work done by Root to study the in-field performance of a liquid DNA-based assay for detection of grape powdery mildew. Growers working with Root’s airborne powdery mildew monitoring system have reported 20-80% reductions in pesticides.

60 APPLIED LIFE SCIENCES↗

Sensor Placement Optimization Software Applied to Site-Scale Methane-Emissions Monitoring

Advances in sensor technology have increased our ability to monitor a wide range of environments. However, even as the cost of sensors decline, only a limited number of sensors can be installed at any given site. The physical placement of sensors, along with the sensor technology and operating conditions, can have a large impact on our ability to adequately monitor environmental change. This paper introduces a new open-source Python package, called Chama, that determines optimal sensor placement and technology to improve a sensor network’s detection capabilities. Additionally, the methods are demonstrated using site-specific methane emission scenarios that capture uncertainty in wind conditions and emission characteristics. Mixed-integer linear programming formulations are used to determine sensor locations and detection thresholds that maximize detection of the emission scenarios. The optimized sensor networks consistently increase the ability to detect leaks, as compared to sensors placed near each potential emission source or along the perimeter of the site.

47 OTHER INSTRUMENTATION↗

Inspection Status Report of Site A/Plot M Report for 2023

The Site A/Plot M Decommissioned Reactor Site was inspected on June 6, 2023. Site A/Plot M is in the Palos Area Preserves, operated by the Forest Preserve District of Cook County. The site was found to be in good condition with negligible erosional concerns across the grass covered mound at Plot M. Landscaping timbers installed along the footpath of Plot M have been effective in reducing erosion down the eastern slope, thus, no additional timber steps are needed at this time. The bike trail, installed by Cook County Forest Preserve, located to the south and east of Plot M has helped to significantly reduce traffic at the site. The Site A and Plot M monuments were both replaced on May 1, 2021, and remain in good condition, despite a small amount of graffiti observed on both monuments at the time of the inspection. The 19 groundwater monitoring wells at Site A/Plot M were found to be secure and in good condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sizing Accuracy of Low-Cost Optical Particle Sensors Under Controlled Laboratory Conditions

Low-cost particulate matter sensors have seen increased use for monitoring at personal and local levels due to their affordability, ease of operation, and high time resolution. However, the quality of data reported by these sensors can be questionable, and a thorough evaluation of their performance is necessary. This study evaluated the particle sizing accuracy of several commonly used optical sensors, including the Alphasense optical particle counter (OPC), TSI DustTrak DRX aerosol monitor, Plantower PMS5003 sensor, and Sensirion SPS30 sensor, using laboratory-generated monodisperse particles. The OPC and DRX agreed partially with reference instruments and showed promise in detecting coarse-size particles. However, the PMS5003 and SPS30 did not correctly size fine and coarse particles. Furthermore, their reported mass distributions do not directly correspond to their number distribution. Despite these limitations, field measurements involving a dust storm period showed that the SPS30 correlated reasonably well with reference instruments for both PM2.5 and PM10, though the regression slopes differed significantly. These findings underscore the need for caution when interpreting data from low-cost optical sensors, particularly for coarse particles. Recommendations for improving the performance of these sensors are also provided.

Gautam, Prakash↗

Microbial sensor system for monitoring the environment and surfaces

A microbial sensor, system and method that can be used to determine the biochemical conditions of waters, saturated sediments, unsaturated soils, rhizosphere and other environments is disclosed. The flexibility of the microbial sensor design allows for the monitoring of surfaces (skin, ventilation conduits, etc.). An electrochemical microbial sensor system is composed of an indicator electrode(s) and a reference electrode. The reference electrode employs a hydrogen permeable membrane. The electrochemical system is interfaced into a signal/communication module allowing the manual or automated collection of data from field deployments and laboratory investigations. The data is transmitted using various communication technologies including Bluetooth™, cellular, satellite and radio telemetry to cloud-based data management systems. The stored data may be downloaded by users using open-source dashboard and visualization software to image the various environments and/or surfaces investigated.

Burge, Scott R.↗

Influence of background sources and topographic resolution in the Weather Research and Forecasting Model on xenon plume characteristics at monitoring stations

For many atmospheric monitoring applications, networks of measurement sites—such as the radionuclide stations of the International Monitoring System—can be sparse. With measurement locations potentially hundreds to thousands of kilometers from a release it is important to quantify the effects of physical processes on transport and dispersion of plumes between source and measurement locations. This study addresses the effects of background sources and topography resolution near the release location of radionuclides. We use the Weather Research and Forecasting (WRF) model with inline chemistry to investigate (1) how an additional, time-varying source of 133 Xe, such as an operational medical isotope production facility, contributes to activity concentration measurements at monitoring sites, and (2) how complex topography influences on atmospheric conditions near emission sources impact plume concentrations at varying distances from the source. Two 133 Xe emission sources, including (1) a high flux rate of short duration representing an explosive event, and (2) a variable and continuous background source, are simulated. The continuous background source contributes significantly to total 133 Xe concentrations at several monitoring stations. Further, a WRF simulation at 9 km horizontal resolution is compared with a nested grid simulation, where the innermost domain has a resolution of 1 km. Increased topographic resolution leads to an improved representation of plume responses to local winds, with topographic influences greatest at locations closest to the sources. Differences between the two domain resolutions decrease at greater distances from the sources, as plumes have time to spread and mix and are influenced by synoptic scale circulation patterns that are represented similarly in both simulations.

54 ENVIRONMENTAL SCIENCES↗

Potential of deep learning methods to enhance satellite-based monitoring of nuclear power plants focusing on remote operation evaluations

The anticipated expansion of the nuclear industry and the deployment of new nuclear reactors (200 + GW of new nuclear capacity by 2050) require the development of monitoring systems that align with safety and security concerns, providing enhanced evaluation capabilities. A remote monitoring system using satellites and deep learning techniques was evaluated for its ability to detect anomalies and capture various features of nuclear reactors independently of the conditions on the ground. Satellite images of current operational and under-construction nuclear power plants were collected from Google Earth Pro as a surrogate database. Subsequently, five datasets were created from the collected images. Transfer learning technique was used for several classification tasks utilizing VGG16, ResNet50V2, Xception, DenseNet121, and MobileNetV2 pre-trained models. In the first task, the capability of the monitoring system to detect abnormal conditions or processes in a nuclear power plant was investigated. In the second task, the ability to capture operational features remotely was examined. As an example, for the purposes of this study, these features included classifying reactors based on type, power range, or onsite condition. Several evaluation metrics were used to compare the performance of the pre-trained models and the overall monitoring system. Here, the evaluation results demonstrated that deep learning techniques and pre-trained models applied to satellite images have the potential to facilitate further and expand capabilities in monitoring systems to assess plant operation details.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Temporal Galactose‐Manganese Feeding in Fed‐Batch and Perfusion Bioreactors Modulates UDP‐Galactose Pools for Enhanced mAb Glycosylation Homogeneity

ABSTRACT Monoclonal antibodies (mAbs) represent a majority of biotherapeutics in the market today. These glycoproteins undergo posttranslational modifications, such as N‐linked glycosylation, that influence the structural & functional characteristics of the antibody. Glycosylation is a heterogenous posttranslational modification that may influence therapeutic glycoprotein stability and clinical efficacy, which is why it is often considered a critical quality attribute (CQA) of the mAb product. While much is known about the glycosylation pathways of Chinese Hamster Ovary (CHO) cells and how cell culture chemical modifiers may influence the N‐glycosylation profile of the final product, this knowledge is often based on the final cumulative glycan profile at the end of the batch process. Building a temporal understanding of N‐glycosylation and how mAb glycoform composition responds to real‐time changes in the biomanufacturing process will help build integrated process models that may allow for glycosylation control to produce a more homogenous product. Here, we look at the effect of specific nutrient feed media additives (e.g., galactose, manganese) and feeding times on the N‐glycosylation pathway to modulate N‐glycosylation of a Herceptin biosimilar mAb (i.e., Trastuzumab). We deploy the N‐GLYcanyzer process analytical technology (PAT) to monitor glycoforms in near real‐time for bench‐scale bioprocesses operated in both fed‐batch and perfusion modes to build an understanding of how temporal changes in mAb N‐glycosylation are dependent on specific media additives. We find that Trastuzumab terminal galactosylation is sensitive to media feeding times and intracellular nucleotide sugar pools. Temporal analysis reveals an increased desirable production of single and double galactose‐occupied glycoforms over time under glucose‐starved fed‐batch cultures. Comparable galactosylation profiles were also observed between fed‐batch (nutrient‐limited) and perfusion (non‐nutrient‐limited) bioprocess conditions. In summary, our results demonstrate the utility of real‐time monitoring of mAb glycoforms and feeding critical cell culture nutrients under fed‐batch and perfusion bioprocessing conditions to produce higher‐quality biologics.

Biotechnology & Applied Microbiology↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 1. Characterizing Thermal–Hydrological–Mechanical Processes

Abstract Bentonite clay is widely used in engineered barrier systems for the permanent disposal of high‐level radioactive waste due to its low permeability, high swelling capacity, and thermal stability. However, the complex thermal‐hydrological‐mechanical (THM) processes induced by heating from decaying radioactive waste and hydration from surrounding rock can lead to heterogeneous changes that are difficult to measure and predict. This study develops an Electrical Resistivity Tomography (ERT)‐based framework for monitoring THM processes, progressing from sample‐scale to bench‐scale tests, to inform field‐scale applications. Sample‐scale tests analyzed small bentonite samples under controlled variations in water content, temperature, and porosity to establish fundamental resistivity relationships. Bench‐scale tests involved larger bentonite columns subjected to heating (up to 200°C) and hydration under controlled pressure, simulating repository conditions. ERT measurements, complemented by X‐ray CT imaging, temperature monitoring, and tracing sensors, revealed coupled THM processes, such as hydration‐induced compression, swelling, and thermal gradients, leading to complex resistivity patterns. The results demonstrate the potential of ERT for capturing THM‐induced resistivity changes, though challenges remain in upscaling and quantitative analysis. This study evaluates laboratory test capabilities and proposes future improvements for understanding THM‐induced resistivity responses. A conceptual framework for ERT implementation in field‐scale monitoring is presented, synthesizing findings from both scales and exploring how ERT data can inform long‐term modeling and reduce prediction uncertainties. Overall, this ERT‐based framework offers a robust method for monitoring bentonite buffers, aiding in early issue detection and supporting the safe long‐term disposal of radioactive waste in geological repositories, while highlighting the need for future development. Plain Language Summary Bentonite clay is crucial in engineered barrier systems (EBS) for containing high‐level radioactive waste due to its ability to absorb water, swell, seal and remain stable under high temperatures. When bentonite absorbs water and heats up from radioactive decay, it experiences complex changes in its physical and mechanical properties. Understanding these changes is important for ensuring the long‐term safety and effectiveness of EBS. This study used Electrical Resistivity Tomography (ERT), a non‐invasive method that measures electrical conductivity to monitor these changes during laboratory experiments. The ERT data revealed significant variations in resistivity corresponding to changes in water content, temperature, and density, providing detailed spatial and temporal insights into the behavior of bentonite. These findings enhance our ability to predict the long‐term performance of bentonite barriers, ensuring the safe containment of radioactive waste. By improving our understanding of bentonite's behavior, this research supports the development of more reliable and effective barrier systems for radioactive waste disposal, protecting the environment and public health. Key Points ERT monitoring was employed to capture resistivity changes in bentonite during controlled heating and hydration experiments, providing insights into THM processes ERT data reveal significant resistivity changes correlated with water content, temperature, and mechanical effects, enhancing the understanding of THM dynamics in bentonite This study explores the potential of the framework for application in field‐scale EBS monitoring, emphasizing the need for integrating additional geophysical methods for comprehensive subsurface imaging

Chen, Hang↗

H2 Sensing with an Optical Fiber Sensor in the Subsurface H2 Storage Conditions

The concentration of hydrogen is subject to change due to biological reactions in the underground hydrogen storage reservoirs. Thus, monitoring hydrogen concentration in the subsurface gas deposits is vital to ensure the integrity and safety of the storage facilities. In this study, the optical fiber hydrogen sensor was developed and validated in relevant subsurface storage environments. Specifically, the sensor has demonstrated successful sensing performance at high temperatures (~80 °C) and high pressures (~1,000 psi) under very humid conditions (~100% RH). In addition, the sensor was exposed to real subsurface microbial samples to monitor microbially induced changes in hydrogen concentration. The sensor has shown stable H2 sensing responses in the replicated underground hydrogen storage conditions without deterioration or loss of H2 sensitivity. The biotic subsurface sample with hydrogen gas resulted in higher transmission intensity change than the abiotic sample due to the possible hydrogen consumption with microbes.

Kim, Daejin↗

Impact of Synthesis and Aging on Titanium Carbide MXenes for Printed Microsystems

This work investigates the long-term electrical stability of Ti3C2Tx MXene Inks under accelerated aging conditions. Inks were synthesized from commercial MAX-Phase precursors, drop-cast onto custom PCB’s and monitored automated in-situ measurements. Samples aged at 85°C/85% RH, 85°C/0% RH and ambient conditions revealed distinct degradation trends. Wet aged inks showed rapid resistance increased while etched formulations exhibited long term stability. These findings highlight the influence of synthesis stage and environmental exposure on MXene Inks reliability, offering critical insights for printed MEMS and sensor applications. Ongoing measurements extend the aging timeline beyond prior studies, marking the longest evaluation under accelerated aging conditions to date.

Aging↗

In situ laser reflectivity to monitor and control the nucleation and growth of atomically thin 2D materials*

The growth of atomically thin two-dimensional (2D) layered and other quantum materials is typically performed without in situ monitoring or control. Here, a simple laser reflectivity approach is demonstrated to provide in situ control over sub-monolayer thickness and growth kinetics during pulsed laser deposition (PLD) of MoSe 2 layers. First, the general technique is presented with emphasis on designing the maximum sensitivity of the optical contrast through consideration of Fresnel's equations with proper choice of layer thickness, substrate, and laser monitoring wavelength, incidence angle, and laser polarization. Then the 632.8 nm optical reflectivity of MoSe 2 layers on SiO 2 /Si substrates was predicted and compared with in situ monitoring of MoSe 2 growth by PLD under actual growth conditions using a probe HeNe laser beam. The measurements showed high sensitivity and excellent agreement with MoSe 2 surface coverages calculated from atomic resolution STEM analysis of 2D layers deposited in arrested growth experiments. Finally, growth kinetics revealed by these measurements showed sigmoidal nucleation and growth stages in the formation of the 2D MoSe 2 layers that are described by a simple model, indicating the promise of the laser reflectivity technique for in situ monitoring and control of 2D materials deposition.

2D materials↗

Long–short-term memory encoder–decoder with regularized hidden dynamics for fault detection in industrial processes

The ability of recurrent neural networks (RNN) to model nonlinear dynamics of high dimensional process data has enabled data-driven RNN-based fault detection algorithms. Previous studies have focused on detecting faults by identifying the discrepancies in data distribution between the faulty and normal data, as reflected in prediction errors generated by RNN models. However, in industrial processes, variations in data distribution can also result from changes in normal control setpoints and compensatory control adjustments in response to disturbances, making it hard to differentiate between normal and faulty conditions. This paper proposes a fault detection method utilizing a long short-term memory (LSTM) encoder–decoder structure with regularized hidden dynamics and reversible instance normalization (RevIN) to compactly represent high-dimensional measurements for effective monitoring. During training, the hidden states of the model are regularized to form a low-dimensional latent space representation of the original multivariate time series data. As a result, the prediction errors of the latent states can be used to monitor the abnormal dynamic variations, while the reconstruction errors of the measured variables are used to monitor the abnormal static variations. Furthermore, the proposed indices can reflect operating conditions, even when the distribution of test data changes, which helps distinguish faults from normal adjustments and disturbances that controllers can settle. Here, data from numerical simulation and the Tennessee Eastman process are used to illustrate the effectiveness of the proposed fault detection method.

42 ENGINEERING↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

Clearing a Path to Commercialization of Marine Renewable Energy Technologies Through Public–Private Collaboration

Governments are increasingly turning toward public–private partnerships to bring industry support to improving public assets or services. Here, we describe a unique public–private collaboration where a government entity has developed mechanisms to support public and private sector advancement and commercialization of monitoring technologies for marine renewable energy. These support mechanisms include access to a range of skilled personnel and test facilities that promote rapid innovation, prove reliability, and inspire creativity in technology development as innovations move from concept to practice. The ability to iteratively test hardware and software components, sensors, and systems can accelerate adoption of new methods and instrumentation designs. As a case study, we present the development of passive acoustic monitoring technologies customized for operation in energetic waves and currents. We discuss the value of testing different systems together, under the same conditions, as well as the progression through different test locations. The outcome is multiple, complementary monitoring technologies that are well suited to addressing an area of high environmental uncertainty and reducing barriers to responsible deployment of low-carbon energy conversion systems, creating solutions for the future.

16 TIDAL AND WAVE POWER↗

Iodine Capture Studies of Copper- and Bismuth-Based Sorbents

The release of radioiodine, one of several radionuclides of concern when recycling used nuclear fuel (UNF), is an important consideration in the fuel cycle. In this study, two sorbent materials, Cu 0 -polyacrylonitrile (PAN) and Bi 0 -PAN, were tested as solid sorbent candidates for iodine capture. Experiments using a thin bed of sorbent material were exposed to vaporized iodine for over 300 hours (~2 weeks) under varied conditions in a dynamic flow environment. The overall performance was monitored in real-time using thermogravimetric analysis, and the materials were subsequently characterized for surface and bulk analysis using scanning electron microscopy – energy-dispersive spectroscopy (SEM-EDS) and powder x-ray diffraction (pXRD), respectively. Iodine (in the form of I 2 ) is expected to be released primarily in the dissolver off-gas (DOG) stream; therefore, this study demonstrates the effects of elemental iodine (I 2 ), water vapor (H 2 O), and nitrogen dioxide (NO 2 ). When exposed to ‘ideal’ conditions (in which I 2 is carried by dry air), Cu 0 -PAN and Bi 0 -PAN behave differently, with TGA analysis indicating that Cu 0 sorption performance is higher than that of Bi 0 , as evidenced by a larger mass change. Under ‘harsh’ conditions—such as a gaseous feed containing I 2 , H 2 O, and NO 2 vapors carried by air,—iodine capture performance for both Cu 0 - and Bi 0 -PAN are affected. SEM-EDS and pXRD analysis of these materials is discussed herein.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗