Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Application of microturbines to control emissions from associated gas

A system for controlling the emission of associated gas produced from a reservoir. In an embodiment, the system comprises a gas compressor including a gas inlet in fluid communication with an associated gas source and a gas outlet. The gas compressor adjusts the pressure of the associated gas to produce a pressure-regulated associated gas. In addition, the system comprises a gas cleaner including a gas inlet in fluid communication with the outlet of the gas compressor, a fuel gas outlet, and a waste product outlet. The gas cleaner separates at least a portion of the sulfur and the water from the associated gas to produce a fuel gas. Further, the system comprises a gas turbine including a fuel gas inlet in fluid communication with the fuel gas outlet of the gas cleaner and an air inlet. Still further, the system comprises a choke in fluid communication with the air inlet.

54 ENVIRONMENTAL SCIENCES↗

Synchronous temperature rate control and apparatus for refrigeration with reduced energy consumption

A refrigerator appliance configuration, and associated methods of operation, for an appliance with a controller, a condenser, at least one evaporator, a compressor, and two refrigeration compartments. The configuration may be equipped with a variable-speed or variable-capacity compressor, variable speed evaporator or compartment fans, a damper, and/or a dual-temperature evaporator with a valve system to control flow of refrigerant through one or more pressure reduction devices. The controller, by operation of the compressor, fans, damper and/or valve system, depending on the appliance configuration, synchronizes alternating cycles of cooling each compartment to a temperature approximately equal to the compartment set point temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synchronous temperature rate control for refrigeration with reduced energy consumption

Methods of operation for refrigerator appliance configurations with a controller, a condenser, at least one evaporator, a compressor, and two refrigeration compartments. The configuration may be equipped with a variable-speed or variable-capacity compressor, variable speed evaporator or compartment fans, a damper, and/or a dual-temperature evaporator with a valve system to control flow of refrigerant through one or more pressure reduction devices. The methods may include synchronizing alternating cycles of cooling each compartment to a temperature approximately equal to the compartment set point temperature by operation of the compressor, fans, damper and/or valve system. The methods may also include controlling the cooling rate in one or both compartments. Refrigeration compartment cooling may begin at an interval before or after when the freezer compartment reaches its lower threshold temperature. Freezer compartment cooling may begin at an interval before or after when the freezer compartment reaches its upper threshold temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synchronous compartment temperature control and apparatus for refrigeration with reduced energy consumption

A refrigerator appliance configuration, and associated methods of operation, for an appliance with a controller, a condenser, at least one evaporator, a compressor, and two refrigeration compartments. The configuration may be equipped with a variable-speed or variable-capacity compressor, variable speed evaporator or compartment fans, a damper and/or a dual-temperature evaporator with a valve system to control flow of refrigerant through one or more pressure reduction devices. The controller, by operation of the compressor, fans, damper and/or valve system, depending on the appliance configuration, controls the cooling rate in one or both compartments to synchronize, alternating cycles of cooling the compartments to their set point temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Bunch Compression Method for Free Electron Lasers that Avoids Parasitic Compressions

Virtually all existing high energy (>few MeV) linac-driven FELs compress the electron bunch length though the use of off-crest acceleration on the rising side of the RF waveform followed by transport through a magnetic chicane. This approach has at least three flaws: 1) it is difficult to correct aberrations--particularly RF curvature, 2) rising side acceleration exacerbates space charge-induced distortion of the longitudinal phase space, and 3) all achromatic "negative compaction" compressors create parasitic compression during the final compression process, increasing the CSR-induced emittance growth. One can avoid these deficiencies by using acceleration on the falling side of the RF waveform and a compressor with M 56 >0. This approach offers multiple advantages: 1) It is readily achieved in beam lines supporting simple schemes for aberration compensation, 2) Longitudinal space charge (LSC)-induced phase space distortion tends, on the falling side of the RF waveform, to enhance the chirp, and 3) Compressors with M 56 >0 can be configured to avoid spurious over-compression. We will discuss this bunch compression scheme in detail and give results of a successful beam test in April 2012 using the JLab UV Demo FEL

43 PARTICLE ACCELERATORS↗

Power plant emissions reduction

A system for improved emissions performance of a power plant generally includes an exhaust gas recirculation system having an exhaust gas compressor disposed downstream from the combustor, a condensation collection system at least partially disposed upstream from the exhaust gas compressor, and a mixing chamber in fluid communication with the exhaust gas compressor and the condensation collection system, where the mixing chamber is in fluid communication with the combustor.

20 FOSSIL-FUELED POWER PLANTS↗

Gas turbine engine

A gas turbine engine with a compressor rotor having compressor impulse blades that delivers gas at supersonic conditions to a stator. The stator includes a one or more aerodynamic ducts that each have a converging portion and a diverging portion for deceleration of the selected gas to subsonic conditions and to deliver a high pressure oxidant containing gas to flameholders. The flameholders may be provided as trapped vortex combustors, for combustion of a fuel to produce hot pressurized combustion gases. The hot pressurized combustion gases are choked before passing out of an aerodynamic duct to a turbine. Work is recovered in a turbine by expanding the combustion gases through impulse blades. By balancing the axial loading on compressor impulse blades and turbine impulse blades, asymmetrical thrust is minimized or avoided.

33 ADVANCED PROPULSION SYSTEMS↗

Assessment of DR-55 as a Drop-In Replacement for R-410A

R410A has no ozone depletion potential (ODP), and is the most commonly used refrigerant in vapor compression systems for space cooling and heating applications. However, it has significant global warming potential with GWP higher than 1900. To mitigate the global warming effect, industry and research institutes are actively pursuing a replacement for R-410A with the following attributes, much lower GWP along with similar or higher efficiency and capacity. DR-55 (aka R452B) is a design-compatible refrigerant replacement for R-410A. It decreases the GWP by 70%, and has lower working pressure, comparable discharge temperature, and uses the same lubricant, tubing, and valves. In this study, we experimentally evaluated the performance of DR-55 as a drop-in replacement for R-410A in a high efficiency rooftop air conditioning unit. The experimental results demonstrated that DR-55 led to 5% higher efficiency at the working conditions of Integrated Energy Efficiency Rating (IEER). DR-55 also showed significantly better high ambient performance from 95 F to 125 F. In addition to the experimental study, we used the DOE/ORNL Heat Pump Design Model to model the RTU using R-410A and DR-55, respectively. The model results were compared to the laboratory measurements. The model validation demonstrates that the refrigerant heat transfer and pressure drop correlations, developed for conventional refrigerants like R-410A, are usable for DR-55. Also, a converted compressor model for DR-55, i.e. reducing volumetric and isentropic efficiencies as a function of the suction and discharge pressures from an R-410A compressor map can predict the compressor mass flow rate and power accurately.

DR-55↗

Providing plastic zone extrusion

Plastic zone extrusion may be provided. First, a compressor may generate frictional heat in stock to place the stock in a plastic zone of the stock. Then, a conveyer may receive the stock in its plastic zone from the compressor and transport the stock in its plastic zone from the compressor. Next, a die may receive the stock in its plastic zone from the conveyer and extrude the stock to form a wire.

36 MATERIALS SCIENCE↗

Synchronous temperature rate control for refrigeration with reduced energy consumption

Methods of operation for refrigerator appliance configurations with a controller, a condenser, at least one evaporator, a compressor, and two refrigeration compartments. The configuration may be equipped with a variable-speed or variable-capacity compressor, variable speed evaporator or compartment fans, a damper, and/or a dual-temperature evaporator with a valve system to control flow of refrigerant through one or more pressure reduction devices. The methods may include synchronizing alternating cycles of cooling each compartment to a temperature approximately equal to the compartment set point temperature by operation of the compressor, fans, damper and/or valve system. The methods may also include controlling the cooling rate in one or both compartments. Refrigeration compartment cooling may begin at an interval before or after when the freezer compartment reaches its lower threshold temperature. Freezer compartment cooling may begin at an interval before or after when the freezer compartment reaches its upper threshold temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Membrane Distillation Technology Utilizing Waste Heat for Treatment of High Salinity Wastewaters

Membrane distillation (MD) can serve as a cost effective method to treat high salinity wastewaters, especially if waste heat is utilized for its operation. The goal of this work is to study the feasibility of employing MD technology for the treatment of high salinity wastewaters which are generated as a result of natural gas production and active reservoir management for CO 2 sequestration. This study also aimed at quantifying the availability of waste heat which could be used as the primary source of thermal energy to drive the MD process. Bench scale studies were carried out with several commercially available membranes using both synthetic and actual high salinity wastewaters. The membranes tested with real wastewater samples exhibited excellent rejection of dissolved ions, including naturally occurring radioactive material (NORM). Long term bench scale experiments with real produced water from the Marcellus shale play revealed that iron oxide could precipitate on the feed side of direct contact MD (DCMD) module but had a negligible effect on the performance of the system. Based on the bench scale experiments, an ASPEN Plus simulation, which incorporated a mathematical model with fundamental heat and mass transfer equations, was developed and used to evaluate the process energy requirements. Despite low operating temperature and pressure for MD, it had a large thermal energy requirement for operation, which could make this technology expensive compared to reverse osmosis (RO) and forward osmosis (FO). However, it is important to note that RO and FO have limited applicability for high salinity shale gas wastewater. Moreover, MD could be integrated with renewable energy sources such as wind or solar energy or industrial waste heat sources to offset the thermal energy requirements and enhance the economics of wastewater treatment. Natural gas compressor stations (NG CS) have been proposed in this study as the source of waste heat based on the estimate of quantity and quality of available waste heat in the exhaust streams of gas turbine and internal combustion compressor engines. Using the actual installed capacity and location of compressor stations in the U.S., this analysis revealed that an average of 610 TJ/day of thermal energy is available at existing NG CS and that this source of waste heat is of high quality with temperatures above 645 K. A systems-level integration of MD with waste heat from NG CS revealed that approximately 56% of available waste heat at NG CS in Pennsylvania is sufficient to concentrate (from 10% to 30% salinity) all wastewater associated with shale gas extraction. Techno-economic assessment (TEA) accounting for capital as well as operating and maintenance costs with and without waste heat integration was conducted for a hypothetical 0.5 million gallons per day (MGD) DCMD plant using experimental and modeling results from this study. TEA revealed that the total cost of shale gas wastewater treatment using MD is $5.7/m 3 feed for the base case scenario in which the thermal energy requirements are met by external steam, however, the total cost can be reduced to $0.74/m 3 feed when integrated with free waste heat from NG CS. Sensitivity analysis revealed that thermal energy cost and feed TDS are the most important factors in total cost of high salinity wastewater treatment using DCMD.

03 NATURAL GAS↗

Refrigerant charge management in an integrated heat pump

A heat pump including an integrated system for the management of refrigerant charge is provided. The heat pump includes an indoor line and an outdoor line that are connected to a compressor through a reversing valve. Refrigerant charge is managed by coupling the inactive line to the suction side of the compressor. For example, the heat pump can include an expansion valve to couple the inactive line to the compressor to supplement the flow-rate of refrigerant. The heat pump is operable in a dedicated water heating mode and a space cooling and water heating mode in some embodiments, while other modes of operation are contemplated in other embodiments.

42 ENGINEERING↗

Two-tier tube-trailer operation method and system to reduce hydrogen refueling cost

A method and system are provided for operating refueling station tube-trailers and compressors to reduce hydrogen refueling cost. A hydrogen refueling station includes a two-tier fuel supply of pressure vessels on a refueling station tube-trailer, with a first tier and a second tier of pressure vessels including at least one or more pressure vessels connected together. A separate control unit is coupled to the first tier and the second tier of pressure vessels with each of the control units coupled to a compressor. The compressor is coupled to a high pressure buffer storage by a separate control unit. In operation, pressure is monitored in the each tier. Hydrogen is consolidated selectively between the first tier of pressure vessel banks, the second tier pressure vessels, and the high pressure buffer. Based upon monitored pressures, one of the first tier of pressure vessels, the second tier pressure vessel banks, and the high pressure buffer is used to refuel vehicles.

Reddi, Krishna↗

Thermoelectric energy storage system and an associated method thereof

Thermoelectric energy storage system and an associated method are disclosed. The thermoelectric energy storage system includes a first refrigeration system, a power system, a first thermal storage unit, and a second thermal storage unit. The first refrigeration system includes a first heat exchanger, a first compressor, a second heat exchanger, and a first expander. The first heat exchanger is disposed upstream relative to the first compressor. The power system includes a third heat exchanger, a second compressor, a fourth heat exchanger, a fifth heat exchanger, and a second expander. The third heat exchanger is disposed upstream relative to the fourth heat exchanger. The fifth heat exchanger is disposed downstream relative to the second expander. The first thermal storage unit is coupled to the first heat exchanger and the fifth heat exchanger. The second thermal storage unit is coupled to the first refrigeration system and the power system.

25 ENERGY STORAGE↗

Integrated tube-trailer and stationary ground storage system and method for enhanced pressure consolidation operations for refueling of gaseous fuels

An enhanced operating method and an integrated tube-trailers and stationary ground storage system are provided for implementing enhanced pressure consolidation operations for refueling gaseous fuels. The integrated tube-trailers and stationary ground storage system includes gaseous fuel supply tube-trailers and stationary ground storage including at least one or more stationary pressure vessels. A compressor can be supplied by both the stationary ground storage and the tube-trailers. The stationary ground storage can provide higher pressure to the compressor than the tube-trailers, enabling enhanced compressor throughput during refueling operation, and enhanced utilization of tube-trailers payload.

Elgowainy, Amgad↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Ultra efficient turbo-compression cooling systems

Aspects of the present disclosure include a system for turbo-compression cooling. The system may be aboard a marine vessel. The system includes a power cycle and a cooling cycle. The power cycle includes a first working fluid, a waste heat boiler configured to evaporate the working fluid, a turbine, and a condenser. The condenser condenses the working fluid to a saturated or subcooled liquid. The cooling cycle includes a second working fluid, a first compressor configured to increase the pressure of the second working fluid, a condenser configured to condense the second working fluid to a saturated or subcooled liquid after exiting the first compressor, an expansion valve, and an evaporator. The turbine and first compressor are coupled one to the other. The waste heat boiler receives waste heat from engine jacket water and lubricating oil from a ship service generator. The evaporator cools water in a shipboard cooling loop.

Bandhauer, Todd M.↗

Next Generation Refrigerants for Domestic Heat Pump Water Heaters

To select next generation refrigerants and phase out R-134a, we conducted extensive drop-in tests of multiple new refrigerants. For laboratory investigations, we performed drop-in UEF (uniform energy factor) and FHR (first hour rating) tests on two heat pump water heaters (HPWHs), one uses a 220V compressor and 40-gallon water tank, and the other uses a 120V compressor and 50-gallon tank. The alternative refrigerants/blends include R-1234yf, R-1234ze, R-515B, R-513A, and R-516A, among which R-513A is A1, non-flammable and the others are in A2L category. All the alternative refrigerants required similar optimum system charges as the baseline R-134a. They resulted in similar or better UEFs than R-134a. R-516A led to best UEFs in both the HPWHs. The resultant discharge temperatures of the new refrigerants/blends are lower than R-134a, indicating good lubricant compatibility. The 120V HPWH delivered > 60 gallons first-hour rating using R-134a. The alternatives led to reduced FHRs due to their smaller volumetric vaporization capacities using the same compressor. Except R-515B, the other refrigerants/blends delivered FHRs > 60 gallons. R-516A produced better UEFs and FHRs in both the units than the other replacements. If considering flammability, R-513A would be the best option, which has similar UEF and FHR as R-134a.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗