Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings

Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Off-the-Shelf Flexible Contact Stress Sensor System: Design Thinking and Systems Engineering Assignment

NNSA has a need to measure the contact stress over long-term durations with minimal impact on the element of interest. The sensor and package should have a small footprint, thin, flexible, modular, and preferably commercially available. There exists an opportunity to leverage expertise within LLNL in sensor development to provide a minimally invasive contact stress sensing solution for NNSA and potentially external customers.

42 ENGINEERING↗

Driving the Shift to Energy-Efficient and Climate-Responsible Commercial Refrigeration Equipment in Chile

This report provides an overview of global and Chile-specific market trends, technological advancements, and policy developments related to commercial refrigeration equipment, with an emphasis on refrigerated display cabinets. Section 2 examines CRE market trends at the global and Chilean levels. Section 3 presents CRE energy consumption and the latest technological options for improving energy performance. It also discusses low global warming potential (GWP)1 refrigerant options for CRE. Section 4 provides a cost-effectiveness analysis. Section 5 reviews other regional energy efficiency standards and labeling programs and offers potential standard requirements for Chile. Section 6 concludes the report by summarizing key findings and conclusions. Finally, Appendix A provides detailed guidelines intended as a starting point to inform policies and programmes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community Solar and Community Solar+Storage: A Roadmap of Barriers and Solutions for Commercial Systems in NYC

Sustainable CUNY worked with decision makers and subject matter experts (SME's) to identify the barriers to and solutions for advancing commercial Community Solar (CS) and CS+Storage (CS+S) in urban areas. This roadmap captures the key challenges and solutions identified by New York City (NYC) stakeholders, including the Real Estate Board of New York (REBNY), through a collaborative process. Solar, as well as storage, are among the fastest growing energy segments in the United States, with CS, also known as Community Distributed Generation (CDG), gaining popularity with those who may not own or have access to a viable roof. Urban areas like NYC, which have a large population of renters, are particularly well suited for CS projects where credits from the power produced by a large remote installation are offered on a subscription basis to residents or businesses in the community. However, CS and CS+S projects have stalled at the doorstep of many cities. Host site owners, particularly those with large rooftops, have been slow to commit to installing CS due to competing rooftop usage and programs, limited knowledge about incentives, lack of economic data, and a complicated implementation process.

14 SOLAR ENERGY↗

Critical Role of the Public Theory & Modeling Program for Commercial Fusion Energy

This white paper contributes input from the Executive Committee of the Theory Coordinating Committee to the 2024 FESAC Decadal Plan Subcommittee. It is argued that the public Theory and Modeling program plays a critical role in the pursuit of commercial fusion energy. A new mechanism for fostering engagement between the fusion industry and the public Theory and Modeling program could provide better alignment between the goals of the public program and the needs of private industry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Innovations in Direct Air Capture: Unveiling a Simple and Robust Synthesized Fibrous Amine-functionalized Matrix (FAM) Sorbent for Commercial Scale-up

The escalating challenge of climate change necessitates innovative solutions in the realm of carbon management, particularly in mitigating the impact of fossil fuel emissions. Direct Air Capture (DAC) technology emerged as a critical component within the spectrum of Carbon Capture and Sequestration (CCS) solutions, offering the distinct advantage of directly removing CO2 from the atmosphere irrespective of the source. This attribute grants DAC systems unparalleled flexibility in deployment locations and the potential to make substantial contributions to lowing atmospheric CO2 levels. The success of DAC technologies significantly depends on the development of an efficient, economical sorbent capable of selective and durable CO2 capture from ambient air. Recent advancements in material science have led to the exploration of amine-functionalized sorbents, hollow fiber sorbents and membranes, and other novel materials designed to meet these criteria. This study explores a novel Fibrous Amine-functionalized Matrix (FAM) sorbent. The FAM sorbent distinguished itself through its mechanical robustness, a streamlined synthesis process, and the capability for low-temperature regeneration (is 90 oC really low temperature?). FAM’s exceptional adsorption-desorption kinetics enable swift CO2 capture and release, crucial for the viability of DAC on a commercial scale. The synthesis process involves a simple dip-coating technique, allowing crosslinked amines to coat glass substrates.

Wang, Qiuming↗

Evaluating Neural Radiance Fields for Commercial Satellite Video

We evaluate neural radiance fields (NeRFs) as a method for reconstructing 3D volumetric scenes from low Earth orbit satellite imagery. We leverage commercial satellite data to reconstruct a scene using existing software tools. In doing so, we identify difficulties in these mapping datasets for NeRF generation. We propose potential applications in geospatial intelligence for context and improved image interpretation.

97 MATHEMATICS AND COMPUTING↗

Commercialization of Distribution System Load Modeling Tool for Improved DER Interconnection Studies

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

14 SOLAR ENERGY↗

Irradiation Results of Commercial Neutron and Gamma Sensors at the Ohio State University Research Reactor

This report serves to present the evaluation results of commercial radiation detectors (SPNDs) with the potential to accomplish the data objectives—having sufficient gamma and fast neutron sensitivity—at temperatures near 650°C. The detectors chosen for evaluation are gamma ion chambers from Exosens (previously known as Photonis) models CRGA11 and CRGE32 and tantalum-based self-powered neutron detectors (Ta-SPND) from Mirion. The evaluation was performed in a series of heat irradiations from ambient to 850°C in the 9.5-inch dry tube furnace at the Ohio State University Research Reactor (OSURR). Ion chamber counting curves were measured to evaluate sensor operability at temperature. Detector sensitivity to reactor power and temperature were measured and presented in curve fit parameters. The curve fit equations were used to identify the suggested operational temperatures based on reactor power. Overall, it was evaluated that the CRGA11 was not significantly affected by temperatures up to 650°C and is operable—with higher temperature-contributed signals—up to 700°C. The CRGE32 was more affected by the high temperatures compared to the CRGA11. As a result of increasing temperature, the leakage current was a dominating factor. While the detector can operate up to 600°C and 700°C with lowered high voltage, it is not recommended unless a suitably strong gamma flux field is present. Finally, Ta SPND did not demonstrate good performance beyond 350°C due to the presence of an unknown phenomenon at changing temperatures. The study of the phenomenon is an active research topic outside the scope of this project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Atom Probe characterization of neutron irradiated commercial ZIRLO® and AXIOM X2® alloys

As part of the Mechanistic Understanding of ZIrconium Corrosion (MUZIC) program, this team has been instrumental to obtain EPRI and Westinghouse sponsorships to prepare the neutron irradiated ZIRLO® and X2® from Vogtle nuclear power plant and ship them from Studsvik’s (Sweden) hot cells to Idaho National Laboratory (INL) to be part of the NSUF library. The uniqueness of these sets of neutron irradiated alloys is that they are at the same two extremes of the fuel cycles, allowing us to study the microchemistry evolution as a function of irradiation doses, exposure time and solute content. Advanced commercial Zirconium-Niobium (Zr-Nb) alloys, such as ZIRLO® and AXIOM®, have been developed by Westinghouse to enhance the corrosion resistance of fuel cladding material for longer service time. This study specifically aims at investigating the neutron irradiation induced Nb redistribution in AXIOM® X2® to understand the effect of neutron irradiation induced microchemistry changes and the irradiation enhanced corrosion resistance observed in ZrNb alloys. The detailed sample information on chemical composition and irradiation is given in shown in Table 1a and 1b respectively. To study the neutron IIP/nanoclusters and Nb concentration in the solid solution, atom probe tomography (APT) is the primary tool to obtain reliable chemical information. APT specimens were prepared in shielded focused ion beam (FIB) at the Irradiated Materials Characterization Laboratory (IMCL) at INL followed by APT analysis at CAES facility using LEAP 4000XR

36 MATERIALS SCIENCE↗

Commercial Zero Code Plug-In: Zero Energy and Operational Emissions Overlay for Model Energy Codes (Technical Brief)

Model energy codes (MEC) describe requirements needed to demonstrate building energy performance compliance. They can be readily adopted by states and local jurisdictions to support desirable energy efficiency investment in new buildings and major renovations. This report provides commercial building energy code language as an overlay to current MEC, which is recognized by the U.S. DOE as ASHRAE Standard 90.1 2022. The code language provides a performance-based compliance path for achieving net zero energy or net zero operational energy emissions buildings with MEC. The path requires meeting two compliance metric target values: 1) a required minimum level of efficiency and 2) a measure of zero energy or emissions. The supporting documentation illustrates the magnitude of needed efficiency improvement and the additional offsets to be achieved from renewable energy sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancements in Direct Air Capture: Unveiling a Simple and Robust Synthesized Fibrous Amine-functionalized Matrix (FAM) Sorbent for Commercial Scale-up

The escalating challenge of climate change necessitates innovative solutions in the realm of carbon management, particularly in mitigating the impact of fossil fuel emissions. Direct Air Capture (DAC) technology emerges as a critical component within the spectrum of Carbon Capture and Sequestration (CCS) solutions, offering the distinct advantage of directly removing CO2 from the atmosphere irrespective of the source. This attribute grants DAC systems unparalleled flexibility in deployment location sand the potential to make substantial contributions to lowing atmospheric CO2 levels. The success of DAC technologies significantly depends on the development of efficient, economical sorbent capable of selective and durable CO2 capture from ambient air. Recent advancements in material science have led to the exploration of amine-functionalized sorbents, hollow fiber sorbents and membranes, and other novel materials designed to meet these criteria. This study introduces a significant advancement in DAC technology with the development of a Fibrous Amine-functionalized Matrix (FAM) sorbent. The FAM sorbent distinguished itself through its mechanical robustness, a streamlined synthesis process, and the capability for low-temperature regeneration. Its exceptional adsorption-desorption kinetics enable swift CO2 capture and release, crucial for the viability of DAC on a commercial scale.

Wang, Qiuming↗

Commercial Building Prototypes Based on ANSI/ASHRAE/IES Standard 90.1-2019 Appendix G PRM: Technical Support Document

The two paths for documenting compliance with ANSI/ASHRAE/IES Standard 90.1 are the prescriptive path and the performance path. Beyond code programs and rating systems (for example, USGBC-LEED ) are primarily known to use a third path – the Appendix G Performance Rating Method. An update in the 2016 edition of Standard 90.1 approved the Appendix G Performance Rating System for code compliance, extending its application and allowing for greater consistency of modeling rules for code and beyond code building energy modeling. The Appendix G PRM provides rules for the development of whole building energy models of baseline and proposed models for calculating the “performance cost index target” value using the simulated energy results of the baseline and proposed models and the building performance factors published in Table 4.2.1.1 of the Standard. This report documents (1) the methodology used for development of the baseline and proposed energy models of the Pacific Northwest National Laboratory and U.S. Department of Energy commercial building prototypes using the Appendix G Performance Rating Method; and (2) the building performance factors that were calculated using those models.

97 MATHEMATICS AND COMPUTING↗

Key Grid-Interactive Efficient Building Technologies for Federal and Commercial Facilities

This report serves as a resource for building owners and managers interested in deploying GEB technologies in federal and commercial facilities. This document also provides an overview of smart buildings and the prioritization and categorization of GEB technologies that have a high potential to provide grid services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Driven Commercial Building Energy Code Compliance and Technology Inventory for New York City

Building Performance Standards (BPS) are gaining national traction. A BPS will require new processes in the design, construction, and operation of buildings that take the occupants into account and enable predictive analysis to ensure compliance with current and future GHG emissions caps. In New York City, most buildings over 25,000 square feet will be regulated by a BPS starting in 2024, regardless of whether it is new construction permitted under current energy codes or an existing building. This research is one of the first to begin the evaluation of a long-term series of building policies in the context of an open data ecosystem, in cooperation with city agencies. Existing building policies enacted in NYC have ranged from building energy benchmarking and labeling to energy audits to the regulation of GHG emission in buildings. Through the development of a dataset related to building technologies and energy consumption, this project can help to evaluate if meaningful conclusions can be drawn for the data that has been largely self-reported in compliance with city regulations. This project will also provide lessons learned from a deep dive into these types of datasets to provide best practices for municipalities or states seeking to embark on policies like those enacted in NYC. In addition, a Building Automation System (BAS) Stretch Standard of Care (SSOC) for owners, designers, and building operators will enable the measurement and predictive analysis of energy consumption and GHG emissions at the plant, system, or component level, in anticipation of regulated GHG limits on buildings based on energy use. The SSOC is expected to be suitable for use on a national level. The primary feature of an SSOC is a standardized format for a set of BAS points that can be used to control and to gather data from individual plants, systems, or components that are related to building energy consumption. This project examined how measurements compare to prescriptive or simulation-based energy code targets, finding little correlation between predictive 8760-hour energy modeling and actual energy consumption for a small sample (n=27) of buildings constructed after 2015. Other analysis found that, while large multifamily housing (MFH) buildings showed a general trend similar to predicted reductions in energy use from the implementation of model commercial energy codes, this trend was not evident in the office, K-12 school, and hotel use groups in NYC. No upward or downward trends in energy consumption were found when buildings were grouped by size. Energy audit data were analyzed and it appears that there is bias by audit company on measures recommended to clients. Further research should be performed to cross-analyze this with other attributes, such as building size, vintage, and number of stories. Analysis found that for 281 buildings that were permitted and completed after 2015 and had submitted benchmarking data in 2022, between 81% and 96% (by use group) were found to be in compliance with the 2024 to 2029 NYC BPS emission caps, and between 55% and 89% were in compliance with the 2030-2034 caps. This work is beneficial to the public in helping policymakers and building stakeholders better understand the wide-ranging implications of a BPS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗