Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Combustion diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

445 records · Page 25

Optical Characterization of Fuel Injection in a Flame Tube Combustor Using a GE TAPS Injector Configuration

This paper presents results in which we compare fuel staging and its effect on fuel spray pattern, velocity and speciation during combustion for several inlet conditions using a GE TAPS injector configuration. Planar laser-induced fluorescence (PLIF), particle image velocimetry (PIV) and phase Doppler interferometry (PDI) were used to investigate spray patterns and velocity. The 2D PIV provides slices in the flow of axial-vertical or axial horizontal velocity components. With 3D PDI, we obtained 3 components of velocity, and fuel drop sizes. Chemiluminescence imaging and spontaneous Raman scattering (SRS) were used to investigate flame structure, species location and relative species concentration. Phase Doppler and PIV data were acquired using scatter from fuel droplets; therefore, those data were obtained only at the pilot-only test points. Raman measurements were acquired only at 10/90 split points to avoid droplets.

optical diagnostics↗

Flame Tube Testing of a GEA TAPS Injector: Effects of Fuel Staging on Combustor Fuel Spray Patterns, Flow Structure, and Speciation

This paper presents results in which we compare fuel staging and its effect on fuel spray pattern, velocity and speciation during combustion for several inlet conditions using a GE TAPS injector configuration. Planar laser-induced fluorescence (PLIF), particle image velocimetry (PIV) and phase Doppler interferometry (PDI) were used to investigate spray patterns and velocity. The 2D PIV provides slices in the flow of axial-vertical or axial horizontal velocity components. With 3D PDI, we obtained 3 components of velocity, and fuel drop sizes. Chemiluminescence imaging and spontaneous Raman scattering (SRS) were used to investigate flame structure, species location and relative species concentration. Phase Doppler and PIV data were acquired using scatter from fuel droplets; therefore, those data were obtained only at the pilot-only test points. Raman measurements were acquired only at 10/90 split points to avoid droplets.

GE TAPS↗

Acoustic imaging for diagnostics of chemically reacting systems

The concept of local diagnostics, in chemically reacting systems, with acoustic imaging is developed. The elements of acoustic imaging through ellipsoidal mirrors are theoretically discussed. In a general plan of the experimental program, the first system is chosen in these studies to be a simple open jet, non premixed turbulent flame. Methane is the fuel and enriched air is the oxidizer. This simple chemically reacting flow system is established at a Reynolds number (based on cold viscosity) of 50,000. A 1.5 m diameter high resolution acoustic mirror with an f-number of 0.75 is used to map the acoustic source zone along the axis of the flame. The results are presented as acoustic power spectra at various distances from the nozzle exit. It is seen that most of the reaction intensity is localized in a zone within 8 diameters from the exit. The bulk reactions (possibly around the periphery of the larger eddies) are evenly distributed along the length of the flame. Possibilities are seen for locally diagnosing single zones in a multiple cluster of reaction zones that occur frequently in practice. A brief outline is given of the future of this work which will be to apply this technique to chemically reacting flows not limited to combustion.

Ramohalli, K.↗

High-Speed Visualization of Spray Breakup and Velocity Estimation in a Rotating Detonation Combustor Using Laser Induced Fluorescence

The underlying physical processes that liquid fuel sprays undergo in rotating detonation engines, particularly breakup and combustion, are not well understood nor are the coupling effects between the detonation and the spray. In this work, a single liquid jet of liquid fuel is inserted into a hydrogen-air RDC in order to study repetitive-one way coupled detonation interactions. High speed laser induced fluorescence of Jet-A at 300 kHz is used to visualize the dynamic processes inside the RDC for up to 10 ms per test. The employed imaging schemes allowed for unique insight into the spreading of liquid fuel in the azimuthal-axial directions via volumetric laser illumination. The Jet-A velocity field was estimated using OpenOpticalFlow and the impulse events observed colloquially agree with prior work on this test platform.

Instrumentation↗

High-Speed Visualization of Spray Breakup and Velocity Estimation in a Rotating Detonation Combustor Using Laser Induced Fluorescence

The underlying physical processes that liquid fuel sprays undergo in rotating detonation engines, particularly breakup and combustion, are not well understood nor are the coupling effects between the detonation and the spray. In this work, a single liquid jet of liquid fuel is inserted into a hydrogen-air RDC in order to study repetitive-one way coupled detonation interactions. High speed laser induced fluorescence of Jet-A at 300 kHz is used to visualize the dynamic processes inside the RDC for up to 10 ms per test. The employed imaging schemes allowed for unique insight into the spreading of liquid fuel in the azimuthal-axial directions via volumetric laser illumination. The Jet-A velocity field was estimated using OpenOpticalFlow and the impulse events observed colloquially agree with prior work on this test platform.

Instrumentation↗

Fusion for Space Propulsion

The need for fusion propulsion for interplanetary flights is discussed. For a propulsion system, there are three important system attributes: (1) The absolute amount of energy available, (2) the propellant exhaust velocity, and (3) the jet power per unit mass of the propulsion system (specific power). For efficient and affordable human exploration of the solar system, propellant exhaust velocity in excess of 100 km/s and specific power in excess of 10 kW/kg are required. Chemical combustion obviously cannot meet the requirement in propellant exhaust velocity. Nuclear fission processes typically result in producing energy in the form of heat that needs to be manipulated at temperatures limited by materials to about 2,800 K. Using the fission energy to heat a low atomic weight propellant produces propellant velocity of the order of 10 kinds. Alternatively the fission energy can be converted into electricity that is used to accelerate particles to high exhaust velocity. However, the necessary power conversion and conditioning equipment greatly increases the mass of the propulsion system. Fundamental considerations in waste heat rejection and power conditioning in a fission electric propulsion system place a limit on its jet specific power to the order of about 0.2 kW/kg. If fusion can be developed for propulsion, it appears to have the best of all worlds - it can provide the largest absolute amount of energy, the propellant exhaust velocity (> 100 km/s), and the high specific jet power (> 10 kW/kg). An intermediate step towards fusion propulsion might be a bimodal system in which a fission reactor is used to provide some of the energy to drive a fusion propulsion unit. There are similarities as well as differences between applying fusion to propulsion and to terrestrial electrical power generation. The similarities are the underlying plasma and fusion physics, the enabling component technologies, the computational and the diagnostics capabilities. These physics and engineering capabilities have been demonstrated for a fusion reactor gain (Q) of the order of unity (TFTR: 0.25, JET: 0.65, JT-60: Q(sub eq) approx. 1.25). These technological advances made it compelling for considering fusion for propulsion.

Thio, Y. C. Francis↗

Influence of the double bond position in combustion chemistry of methyl butene isomers: A shock tube and laser absorption study

Shock tube experiments have been carried out on 2–methyl–1–butene (2M1B), 2–methyl–2–butene (2M2B), and 3–methyl–1–butene (3M1B)—the three isomers of methyl butene compound. Here, carbon monoxide (CO) time–histories and ignition delay times are obtained behind reflected shockwaves over the temperature range of 1350–1630 K and pressures of 8.3–10.5 atm with stoichiometric mixtures of 0.075% fuel in O 2 /Ar. Comparative ignition study reveals that 3M1B ignites significantly faster than the other two isomers, while 2M1B dissociates earlier but ignites later than 2M2B. Possible mechanisms for this behavior are discussed with ignition delay time sensitivity and reaction path analysis. In addition, time–resolved CO measurements are compared with three different reaction mechanisms from the literature. Sensitivity analyses have been carried out to identify important reactions that need attention to accurately predict the chemistry of these isomers. Further investigation into the rates of unimolecular fuel decomposition reactions and C 3 H 3 + O 2 = CH 2 CO + HCO reaction are suggested based on the current investigation.

09 BIOMASS FUELS↗

Green Propellant Test Capabilities of the Altitude Combustion Stand at the NASA Glenn Research Center

The NASA Glenn Research Center (GRC) is committed to providing simulated altitude rocket test capabilities to NASA programs, other government agencies, private industry partners, and academic partners. A primary facility to support those needs is the Altitude Combustion Stand (ACS). ACS provides the capability to test combustion components at a simulated altitude up to 100,000 ft. (approx.0.2 psia/10 Torr) through a nitrogen-driven ejector system. The facility is equipped with an axial thrust stand, gaseous and cryogenic liquid propellant feed systems, data acquisition system with up to 1000 Hz recording, and automated facility control system. Propellant capabilities include gaseous and liquid hydrogen, gaseous and liquid oxygen, and liquid methane. A water-cooled diffuser, exhaust spray cooling chamber, and multi-stage ejector systems can enable run times up to 180 seconds to 16 minutes. The system can accommodate engines up to 2000-lbf thrust, liquid propellant supply pressures up to 1800 psia, and test at the component level. Engines can also be fired at sea level if needed. The NASA GRC is in the process of modifying ACS capabilities to enable the testing of green propellant (GP) thrusters and components. Green propellants are actively being explored throughout government and industry as a non-toxic replacement to hydrazine monopropellants for applications such as reaction control systems or small spacecraft main propulsion systems. These propellants offer increased performance and cost savings over hydrazine. The modification of ACS is intended to enable testing of a wide range of green propellant engines for research and qualification-like testing applications. Once complete, ACS will have the capability to test green propellant engines up to 880 N in thrust, thermally condition the green propellants, provide test durations up to 60 minutes depending on thrust class, provide high speed control and data acquisition, as well as provide advanced imaging and diagnostics such as infrared (IR) imaging.

Testing↗

Cold Flow Testing for Liquid Propellant Rocket Injector Scaling and Throttling

Scaling and throttling of combustion devices are important capabilities to demonstrate in development of liquid rocket engines for NASA's Space Exploration Mission. Scaling provides the ability to design new injectors and injection elements with predictable performance on the basis of test experience with existing injectors and elements, and could be a key aspect of future development programs. Throttling is the reduction of thrust with fixed designs and is a critical requirement in lunar and other planetary landing missions. A task in the Constellation University Institutes Program (CUIP) has been designed to evaluate spray characteristics when liquid propellant rocket engine injectors are scaled and throttled. The specific objectives of the present study are to characterize injection and primary atomization using cold flow simulations of the reacting sprays. These simulations can provide relevant information because the injection and primary atomization are believed to be the spray processes least affected by the propellant reaction. Cold flow studies also provide acceptable test conditions for a university environment. Three geometric scales - 1/4- scale, 1/2-scale, and full-scale - of two different injector element types - swirl coaxial and shear coaxial - will be designed, fabricated, and tested. A literature review is currently being conducted to revisit and compile the previous scaling documentation. Because it is simple to perform, throttling will also be examined in the present work by measuring primary atomization characteristics as the mass flow rate and pressure drop of the six injector element concepts are reduced, with corresponding changes in chamber backpressure. Simulants will include water and gaseous nitrogen, and an optically accessible chamber will be used for visual and laser-based diagnostics. The chamber will include curtain flow capability to repress recirculation, and additional gas injection to provide independent control of the backpressure. This paper provides a short review of the appropriate literature, as well as descriptions of plans for experimental hardware, test chamber instrumentation, diagnostics, and testing.

Kenny, Jeremy R.↗

Flame Characterization and Flashback Studies of Hydrogen-Enriched Low-Swirl Flames Using High-Speed OH-PLIF

Here, this paper reports the flashback mechanism observed in hydrogen-enriched flames stabilized in a low-swirl burner (LSB) at atmospheric temperature and pressure. The fundamentals of hydrogen-rich stable flames and spatiotemporal information of flashback phenomena were observed experimentally using a high-repetition-rate nanosecond (ns)-duration hydroxyl planar laser-induced fluorescence (OH-PLIF) diagnostic. Testing was conducted for methane and hydrogen (50–90%H 2 , by mole) blends in an optically accessible LSB premixer with measured swirl numbers varying from 0.43 to 0.49. The flashback propensity showed dependence on liftoff length, which was dependent on premixer velocity (𝑉), hydrogen content (𝑋 H 2 ), and equivalence ratio (𝜙) at constant temperature and pressure. High-speed OH-PLIF images revealed that lifted flames were first observed at low 𝜙/𝑋 H 2 conditions, which were changed to an M-shaped flame attached to the burner rim with an increase in 𝜙/𝑋 H 2 . A further increase in 𝜙/𝑋 H 2 triggered the flame flashback into the premixer. Flame 𝜙 at flashback (𝜙 FB ) showed an expected linearly increasing trend with increasing 𝑉 and decreasing 𝑋 H 2 , and the conclusions drawn aligned well with detailed liftoff length investigations. The 𝜙 FB increased with increasing perforated plate hole diameter and increasing swirler vane angle. The vane angle had little effect on flashback tendency at high premixer velocity.

combustion↗

Bulk Spray and Individual Plume Characterization of LPG and Iso-Octane Sprays at Engine-Like Conditions

This study presents experimental and numerical examination of directly injected (DI) propane and iso-octane, surrogates for liquified petroleum gas (LPG) and gasoline, respectively, at various engine like conditions with the overall objective to establish the baseline with regards to fuel delivery required for future high efficiency DI-LPG fueled heavy-duty engines. Sprays for both iso-octane and propane were characterized and the results from the optical diagnostic techniques including high-speed Schlieren and planar Mie scattering imaging were applied to differentiate the liquid-phase regions and the bulk spray phenomenon from single plume behaviors. The experimental results, coupled with high-fidelity internal nozzle-flow simulations were then used to define best practices in CFD Lagrangian spray models. Optical imaging revealed that unlike iso-octane, propane’s spray propagation was fed by its flash boiling, spray collapse, and high degree of vaporization, resulting in a direct proportionality of propane’s penetration length to temperature. These unique features of propane and its variation from iso-octane’s spray pattern, contributed to its classification as an unconventional spray. Appropriate corrections to the injection and breakup models were developed to reproduce the under-expanded jet dynamics and to mimic the flash boiling-driven spray development observed with propane sprays. The simulation results were found to be sensitive to cone and inclusion angles of the blob injector. The current work represents a first assessment of the capability of the commonly available models for engine-spray simulations and highlights the fact that, despite the reasonable agreement obtained in the fuel vapor morphology, the representation of the liquid phase lacks accuracy and requires further model development.

02 PETROLEUM↗

Isopropanol dehydration reaction rate kinetics measurement using H 2 O time histories

H 2 O formation during thermal decomposition of isopropanol was measured behind reflected shock waves at temperatures ranging from 1127 to 1621 K at an average pressure of 1.42 atm using a laser absorption technique. Of the five modern chemical kinetics models used to compare the H 2 O time histories, the model from Li et al (Combust. Flame 2019;207:171-185) showed the best overall agreement. Sensitivity and rate of production analyses using the Li et al model (as well as those from AramcoMech 3.0, CRECK, and Togbe et al (Energy Fuel. 2011;25:676-683)) showed unimolecular dehydration of isopropanol, iC 3 H 7 OH ⇌ H 2 O + C 3 H 6 (R1), is nearly the sole reaction controlling H2O production at early times, allowing for an a priori measurement of the forward rate constant k 1 . The Arrhenius expression k1 (s –1 ) = 2.60 × 10 13 exp(-31 120 K/T) was determined to represent best the data from this study. According to the models and previous experimental investigations, the pressure investigated is well within the high-pressure limit (HPL) for this reaction. Additional, higher-pressure experiments also confirmed the HPL assumption. An uncertainty analysis was performed by varying secondary reactions within their uncertainties and examining their effect on the overall prediction, establishing an uncertainty within ±20% for all but the highest temperature cases, which have a maximum uncertainty of ±40%. Experiments conducted with a radical trapper, toluene, showed little influence from radical chemistry, suggesting this estimated uncertainty is fairly conservative. Experimental data from Heyne et al (Z Phys Chem. 2015;229:881-907) were found to be in good agreement with the rate measurements from this study and, therefore, a second Arrhenius expression, k 1 (s –1 ) = 2.11 × 10 13 exp(-30 820 K/T), was found to represent both datasets well. This second expression has a larger temperature range of 976-1621 K. Here the present study provides the first high-temperature data collected for this reaction, adding to the limited data available for isopropanol in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thin-Filament Pyrometry Developed for Measuring Temperatures in Flames

Many valuable advances in combustion science have come from observations of microgravity flames. This research is contributing to the improved efficiency and reduced emissions of practical combustors and is benefiting terrestrial and spacecraft fire safety. Unfortunately, difficulties associated with microgravity have prevented many types of measurements in microgravity flames. In particular, temperature measurements in flames are extremely important but have been limited in microgravity. A novel method of measuring temperatures in microgravity flames is being developed in-house at the National Center for Microgravity Research and the NASA Glenn Research Center and is described here. Called thin-filament pyrometry, it involves using a camera to determine the local gas temperature from the intensity of inserted fibers glowing in a flame. It is demonstrated here to provide accurate measurements of gas temperatures in a flame simultaneously at many locations. The experiment is shown. The flame is a laminar gas jet diffusion flame fueled by methane (CH4) flowing from a 14-mm round burner at a pressure of 1 atm. A coflowing stream of air is used to prevent flame flicker. Nine glowing fibers are visible. These fibers are made of silicon carbide (SiC) and have a diameter of 15 m (for comparison, the average human hair is 75 m in diameter). Because the fibers are so thin, they do little to disturb the flame and their temperature remains close to that of the local gas. The flame and glowing filaments were imaged with a digital black-and-white video camera. This camera has an imaging area of 1000 by 1000 pixels and a wide dynamic range of 12 bits. The resolution of the camera and optics was 0.1 mm. Optical filters were placed in front of the camera to limit incoming light to 750, 850, 950, and 1050 nm. Temperatures were measured in the same flame in the absence of fibers using 50-m Btype thermocouples. These thermocouples provide very accurate temperatures, but they generally are not useful in microgravity tests because they measure temperature at only one location at a time. Thermocouple measurements at a height of 11 mm above the burner were used to calibrate the thin-filament pyrometry system at all four wavelengths. This calibration was used to perform thin-filament pyrometry at other heights above the burner. One such profile is shown in this graph; this is for a height of 21 mm. The agreement between the pyrometry measurements and thermocouple results at this height is excellent in the range of 1000 to 2000 K, with an estimated uncertainty of 50 K and an estimated upper limit of 2500 K. Neither the thermocouple nor the thin-filament pyrometry temperatures have been corrected for radiation, but the correction is expected to be nearly the same for both methods. We anticipate that thin-filament pyrometry similar to that developed here will become an important diagnostic for studies of microgravity flames owing to its accuracy and its ability to simultaneously measure finely spaced temperatures.

Sunderland, Peter B.↗