Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Large sensitive-area NbN nanowire superconducting single-photon detectors fabricated on single-crystal MgO substrates

We report on the performance of large area NbN nanowire superconducting single-photon detectors (SSPDs). 20x20 {mu}m{sup 2} area SSPDs with 80 and 100 nm linewidths and 50% fill factor were fabricated in 4-nm-thick NbN films grown on single-crystal MgO substrates. The high quality of the devices was verified by electrical and optical testing and compares favorably to measurements of 10x10 {mu}m{sup 2} area SSPDs. Measurements of kinetic inductance versus bias current indicate that the constriction density is low. The fiber-coupled detection efficiency of the devices was 0.4%-3.5% at 100 Hz dark count rate.

36 MATERIALS SCIENCE↗

The LUNA experiment at Gran Sasso Laboratory: Studying stars by going underground

Accurate knowledge of thermonuclear reaction rates is a key issue in nuclear astrophysics: it is important for understanding the energy generation, neutrino production and the synthesis of the elements in stars and during primordial nucleosynthesis. Cross-section measurements are mainly hampered by the very low counting rate and cosmic background. An underground location is extremely advantageous for such studies, as demonstrated by the LUNA experiment in the Gran Sasso Laboratory (Italy). This paper reports on the results recently obtained by this experiment and on the future perspectives in the field.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design Study of an Incinerator Ash Conveyor Counting System - 13323

A design study has been performed for a system that should measure the Cs-137 activity in ash from an incinerator. Radioactive ash, expected to consist of both Cs-134 and Cs-137, will be transported on a conveyor belt at 0.1 m/s. The objective of the counting system is to determine the Cs-137 activity and direct the ash to the correct stream after a diverter. The decision levels are ranging from 8000 to 400000 Bq/kg and the decision error should be as low as possible. The decision error depends on the total measurement uncertainty which depends on the counting statistics and the uncertainty in the efficiency of the geometry. For the low activity decision it is necessary to know the efficiency to be able to determine if the signal from the Cs-137 is above the minimum detectable activity and that it generates enough counts to reach the desired precision. For the higher activity decision the uncertainty of the efficiency needs to be understood to minimize decision errors. The total efficiency of the detector is needed to be able to determine if the detector will be able operate at the count rate at the highest expected activity. The design study that is presented in this paper describes how the objectives of the monitoring systems were obtained, the choice of detector was made and how ISOCS (In Situ Object Counting System) mathematical modeling was used to calculate the efficiency. The ISOCS uncertainty estimator (IUE) was used to determine which parameters of the ash was important to know accurately in order to minimize the uncertainty of the efficiency. The examined parameters include the height of the ash on the conveyor belt, the matrix composition and density and relative efficiency of the detector. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE ANALYTICAL STRUCTURE OF THE PRIMARY INTERSTELLAR HELIUM DISTRIBUTION FUNCTION IN THE HELIOSPHERE

A new analytical model based on the previous work of Lee et al. is presented for the distribution of interstellar helium in the heliosphere. The model is tailored for comparison with the IBEX-Lo observations in order to determine the bulk velocity and temperature of helium in the local interstellar cloud. The model includes solar gravity, spherically symmetric stationary ionization rates, transformation to the Earth/IBEX frame of reference, the IBEX viewing geometry with small spin-axis tilt, and integration of the atom differential intensity over energy and the instrument collimator solid angle. The analysis employs an expansion of the count rate about the peak of the velocity distribution to second order in the magnitudes of several small quantities: the ratio of the helium thermal speed to its bulk speed, the angle between the bulk velocity and the ecliptic, the two angles describing the tilt of the IBEX spin-axis away from Sun-pointing, the collimator angular width, and the angular difference between the observing longitude and the longitude where the projection of the bulk velocity onto the ecliptic is tangential to Earth's orbit. The model reveals the evolving ellipsoidal shape of the helium distribution as it moves along its average hyperbolic orbit. For specified interstellar parameters, the model predicts the latitudinal and longitudinal structure of the helium distribution. The model is in reasonable agreement with IBEX observations and the predictions of the other available models.

79 ASTRONOMY AND ASTROPHYSICS↗

Theoretical estimate of the sensitivity of the CUORE detector to solar axions

In this paper we calculate the potential sensitivity of the CUORE detector to axions produced in the Sun through the Primakoff process and detected by the inverse coherent Bragg-Primakoff process. The conversion rate is calculated using density functional theory for the electron density and realistic expectations for the energy resolution and background of CUORE. Monte Carlo calculations for 5 y × 741 kg = 3705 kg y of exposure are analyzed using time correlation of individual events with the theoretical time-dependent counting rate and lead to an expected limit on the axion-photon coupling g{sub aγγ}<3.83 × 10{sup −10} GeV{sup −1} for axion masses less than 100 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Thicker, more efficient superconducting strip-line detectors for high throughput macromolecules analysis

Fast detectors with large area are required in time-of-flight mass spectrometers for high throughput analysis of biological molecules. We fabricated and characterized subnanosecond 1x1 mm{sup 2} NbN superconducting strip-line detectors. The influence of the strip-line thickness on the temporal characteristics and efficiency of the detector for the impacts of keV accelerated molecules is investigated. We find that the increase of thickness improves both efficiency and response time. In the thicker sample we achieved a rise time of 380 ps, a fall time of 1.38 ns, and a higher count rate. The physics involved in this behavior is investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Free-running InGaAs single photon detector with 1 dark count per second at 10% efficiency

We present a free-running single photon detector for telecom wavelengths based on a negative feedback avalanche photodiode (NFAD). A dark count rate as low as 1 cps was obtained at a detection efficiency of 10%, with an afterpulse probability of 2.2% for 20 μs of deadtime. This was achieved by using an active hold-off circuit and cooling the NFAD with a free-piston stirling cooler down to temperatures of −110 °C. We integrated two detectors into a practical, 625 MHz clocked quantum key distribution system. Stable, real-time key distribution in the presence of 30 dB channel loss was possible, yielding a secret key rate of 350 bps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Phoswich Neutron Detector with Energy Spectroscopy Capability

Neutron measurement technology is critical to the detection and identification of nuclear materials and sources. Portable neutron detectors that enable thermal neutron and fast neutron measurements with a single system are still an experimental area. The ability to employ three signatures (photons, thermal neutrons, and fast neutrons) simultaneously for identification provides an extra element of certainty in results. The energy of fast neutrons can also provide a unique spectral signature for source quantification. A phoswich detector is based on the use of two dissimilar scintillators with a single photomultiplier tube (PMT) for the purpose of radiation detection. Past development was focused primarily on the application of the multi-scintillator design to gamma-ray, alpha- and beta-particle measurements. To this end, the work presented here has focused on the development of a phosphor sandwich ('phoswich') detector capable of differentiating between photons, thermal neutrons, and fast neutrons. The portable phoswich neutron detector was designed using two solid-sate scintillators: the {sup 6}Li-loaded glass and the EJ-299-33A plastic. Experiments showed that detector provides simultaneously count rates of photons, thermal neutrons, and fast neutrons with the energy spectroscopy option. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sapphire analyzers for high-resolution x-ray spectroscopy.

We present a sapphire (Al{sub 2}O{sub 3}) analyzer for high-resolution X-ray spectroscopy with 31-meV energy resolution. The analyzer is designed for resonant inelastic X-ray scattering (RIXS) measurements at the CuK{sub a} absorption edge near 8990 eV. The performance of the analyzer is demonstrated by measuring phonon excitations in beryllium because of its known dynamical structure and high counting rates.

43 PARTICLE ACCELERATORS↗

Advanced X-ray Imaging Crystal Spectrometer for Magnetic Fusion Tokamak Devices

An advanced X-ray imaging crystal spectrometer is currently under development using a segmented position sensitive detector and time-to-digital converter (TDC) based delay-line readout electronics for burning plasma diagnostics. The proposed advanced XICS utilizes an eight-segmented position sensitive multi-wire proportional counter and supporting electronics to increase the spectrometer performance includes the photon count-rate capability and spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor

Detection and measurement of radiation is used extensively for non-invasive material characterization in a range of industries. However, many practical applications are frustrated by pulse pile-up within the detector. Pulse pile-up, which occurs when multiple radiation events arrive within the temporal resolving time of the detector, degrades the fidelity of subsequent material analysis. Traditional pulse processing techniques use fast digital filters and logic circuits to detect piled-up events and discard the corrupted data, however, this leads to substantial detector dead time. Consequently, there is considerable interest in more complex signal-processing algorithms to extend the performance of pulse processors and improve material characterization techniques. We present a technology for real-time decoding of pulse pile-up events. It is a model-based signal-processing algorithm able to accurately characterize the number, time-of-arrival and energy of all events in the detector output. Even in the presence of severe multi-pulse pile-up, the composite events are decoded and the energy and time-of-arrival recovered. The technology has been evaluated using a range of detectors, sources and count rates. An exceptional improvement over traditional pulse processing techniques is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Efficiency Thermoelectric Single-Photon Detector Based on Lanthanum and Cerium Hexaborides

A design for a high-efficiency single-photon detector based on lanthanum and cerium hexaborides, which operates from the infrared to ultraviolet spectral ranges, is suggested. The results of computer simulations of heat transfer in the sensitive element of the detector upon the absorption of photons with energies of 0.5–4.13 eV are presented. To attain a high efficiency of the system of photon detection in the wavelength range from near infrared to ultraviolet, lanthanum hexaboride is proposed as the absorber and heat-sink material in the sensitive element. It is shown that a sensitive element of both single- and three-layer design made entirely of hexaborides will possess a gigahertz counting rate and a detection efficiency exceeding 90%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-G-IeP4-12: Performance of In-111 Coincident Gamma-Ray Counting: A Monte Carlo Simulation

Purpose: The decay of In-111 results in a non-isotropic gamma-ray cascade, which is normally imaged using a gamma camera. Creating images with a gamma camera using coincident gamma-rays from In-111 has not been previously studied. Our objective was to explore the feasibility of imaging this cascade as coincidence events and to determine the optimal timing resolution and source activity using Monte Carlo simulations. Methods: GEANT4 was used to simulate the decay of the In-111 nucleus and to model the gamma camera. Each photon emission was assigned a timestamp, and the time delay and angular separation for the second gamma-ray in the cascade was consistent with the known intermediate state half-life of 85ns. The gamma-rays are transported through a model of a Siemens dual head Symbia “S” gamma camera with a 5/8-inch thick crystal and medium energy collimators. A true coincident event was defined as a single 171keV gamma-ray followed by a single 245keV gamma-ray within a specified time window (or vice versa). Several source activities (ranging from 10uCi to 5mCi) with and without incorporation of background counts were then simulated. Each simulation was analyzed using varying time windows to assess random events. The noise equivalent count rate (NECR) was computed based on the number of true and random counts for each combination of activity and time window. No scatter events were assumed since sources were simulated in air. Results: As expected, increasing the timing window increased the total number of observed coincidences albeit at the expense of true coincidences. A timing window range of 200–500ns maximizes the NECR at clinically-used source activities. The background rate did not significantly alter the maximum NECR. Conclusion: This work suggests coincident measurements of In-111 gamma-ray decay can be performed with commercial gamma cameras at clinically-relevant activities. Work is ongoing to assess useful clinical applications.

60 APPLIED LIFE SCIENCES↗

The advancement of a technique using principal component analysis for the non-intrusive depth profiling of radioactive contamination

A non-intrusive technique using principal component analysis, to infer the depth of the fission fragment caesium-137, when it is buried under silica sand has been described. Using energy variances within different {gamma}-ray spectra, a complete depth model was produced for a single caesium-137 source buried under 1 mm depths ranging between 5-50 mm. This was achieved using a cadmium telluride detector and a bespoke phantom. In this paper we describe the advancement of the technique by further validating it using blind tests for applications outside of the laboratory, where not only the depth (z) but also the surface (x, y) location of {gamma}-ray emitting contamination is often poorly characterised. At present the technique has been tested at the point of maximum activity above the entrained {gamma}-ray emitting source (where the optimal x, y location is known). This is not usually practical in poorly characterized environments where the detector cannot be conveniently placed at such an optimal location to begin with and scanning at multiple points around the region of interest is often required. Using a uniform scanning time, the point of maximum intensity can be located by sampling in terms of total count rate, and converging on this optimal point of maximum intensity. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of a Loop for Fission Gas Release and Monitoring at the PULSTAR Reactor

Modern nuclear fuel performance analysis tools aim at establishing a predictive approach for examining macroscopic fuel behavior due to fuel gaseous swelling and the associated pellet cladding mechanical interaction (PCMI). In general, the macroscopic behavior is highly sensitive to understanding microscopically driven phenomena, which in this case is the release of fission gas (i.e., Kr and Xe) from the fuel. Previous studies identified the uncertainties associated with the intra-granular fission gas diffusion coefficient as most limiting for the accuracy of fission gas release calculations. In particular, it was concluded that, in order to improve fission gas release as well as gaseous swelling predictions using fuel performance codes, a better characterization of the diffusion coefficient is needed. This work explores the implementation of an on-line fission gas release and measurement loop at the North Carolina State University (NCSU) PULSTAR reactor. A unique characteristic of this loop is the ability to control the temperature of the fuel samples during irradiation to establish a more accurate correlation between the irradiation conditions and an observable such as the intragranular gas diffusion coefficient. Analysis was performed of an 'in-pile' fission gas release experiment that is currently under implementation at the NCSU PULSTAR reactor. Using MCNP6 calculations and COMSOL simulations the fission rate density and temperature distributions in UO{sub 2} microspheres were estimated. To explore the feasibility of detecting fission gas isotopes, estimates of R/B for {sup 138}Xe were obtained using the equivalent sphere model and combined with MCNP6 predicted B estimates to obtain R. Assuming detection in a typical gamma-ray spectrometry HPGe system, it was conclude that reasonable count rates will be achieved to allow extraction of release information. At this stage, accurate assessment is underway of the performance of various loop components to set the final design criteria in support of loop fabrication. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solenoid System for PRISM and COMET

An experiment of searching for coherent neutrino-less conversion of muons to electron conversion in muonic atom, {mu}{sup -}+N(A,Z){yields}e{sup -}+N(A,Z), is powerful probe for new physics phenomena beyond the Standard Model. We offer the experiment at a sensitivity of B({mu}{sup -}N{yields}e{sup -}N)<10{sup -16} with muon beamline consisting of high-field pion capture solenoids, curved solenoids to select beam momenta, and a curved solenoid spectrometer to detect {mu}{sup -}-e{sup -} conversion with low-counting-rate conditions. Design of superconducting solenoid magnets of pion capture and transport beam line has been studied and is described in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗