Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSION RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Autoignition of cyclohexane at low-to-intermediate temperatures: Rapid compression machine experiments and improved comprehensive chemical kinetic model

Cycloalkanes are an important class of hydrocarbons found in conventional and alternative transportation fuels. Being one of the simplest practical cycloalkanes, cyclohexane is often used as a surrogate in studies to understand the oxidation, ignition, and sooting characteristics of cycloalkanes more broadly. Although cyclohexane has been extensively studied, very limited datasets for cyclohexane oxidation at low-to-intermediate temperatures are available in the literature. Moreover, the literature autoignition data from rapid compression machines (RCMs) did not provide information on volume histories or experimental heat transfer characteristics which can significantly impact model predictions, thereby hindering the detailed validation of chemical kinetic models. It has also been observed that the cyclohexane kinetic models developed so far are not able to predict the literature data across a wide range of operating and mixture conditions. Hence, further studies are recommended to understand and improve model predictions for cyclohexane oxidation. In this study, RCM experiments were conducted using cyclohexane/air mixtures at varying compressed pressures (P C =15, 20, and 30 bar), equivalence ratios (ϕ=0.5, 1.0, and 2.0), and compressed temperatures (T C =670–960 K). The current RCM results of cyclohexane were found to complement well with the literature data, with the first-stage IDTs at high pressures and volume histories at all test conditions being first reported for better development and validation of chemical kinetic models. Additionally, a detailed chemical kinetic model for the cyclohexane oxidation has been developed and validated using both newly acquired experimental IDTs in this study and literature experimental studies (IDTs in RCMs and STs, species profiles in jet-stirred reactors, and laminar burning velocities). Unlike literature models, the proposed model was observed to provide an overall better prediction for experimental results over a wide range of conditions. Chemical kinetic analysis of the developed model was further conducted to identify the reaction pathways controlling the autoignition of cyclohexane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practicality of magnetic compression for plasma density control

Here, plasma densification through magnetic compression has been suggested for time-resolved control of the wave properties in plasma-based accelerators [P. F. Schmit and N. J. Fisch, Phys. Rev. Lett. 109, 255003 (2012)]. Using particle in cell simulations with real mass ratio, the practicality of large magnetic compression on timescales shorter than the ion gyro-period is investigated. For compression times shorter than the transit time of a compressional Alfven wave across the plasma slab, results show the formation of two counter-propagating shock waves, leading to a highly non-uniform plasma density profile. Furthermore, the plasma slab displays large hydromagnetic like oscillations after the driving field has reached steady state. Peak compression is obtained when the two shocks collide in the mid-plane. At this instant, very large plasma heating is observed, and the plasmaβ is estimated to be about 1. Although these results point out a densification mechanism quite different and more complex than initially envisioned, these features still might be advantageous in particle accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental measurements of soot formation in fuel-rich homogeneous mixtures using an optical rapid compression machine

Advanced combustion strategies are necessary for the use of more environmentally sustainable fuels than traditional diesel. Alcohol fuels and alcohol/gasoline blends are of particular interest as they are readily available in the marketplace. Heavy-duty engines typically use compression ignited, conventional diesel mixing controlled combustion. Mixing controlled combustion features a non-premixed diffusion flame with a wide range of local equivalence ratios, leading to potentially high rates of soot formation. This work studies the sooting behavior of iso-octane and ethanol as a function of equivalence ratio. Measurements are carried out in a rapid compression machine (RCM) and are reported for pre-ignition conditions of 10–30 bar and temperatures of 650–800 K. Theoretical equilibrium and bulk gas temperatures are calculated for both fuels. These data are used to identify the critical equivalence ratio, the lowest equivalence ratio where soot is detected with a single-pass laser extinction diagnostic. The critical equivalence ratio for iso-octane varies between 1.82 and 1.77 for compressed pressures of 10 and 20 bar, respectively. Ethanol, sometimes considered sootless, had a critical equivalence ratio between 2.37 and 2.12 for compressed pressures of 20 and 30 bar, respectively. When characterizing soot formation by oxygenated equivalence ratio, the critical equivalence ratios for ethanol approach those of iso-octane. This suggests the oxygenated nature of alcohol fuels reduces sooting tendency, but other factors such as fuel molecular structure and morphology may play a role. It was observed that ethanol will form soot at equivalence ratios only slightly higher than iso-octane, which could have implications in mixing controlled combustion. It was seen for both fuels that soot formation is pressure sensitive, with the critical equivalence ratio being inversely proportional to compressed pressure and the rate of soot formation. Future work will investigate the sooting behavior of gasoline/ethanol blends.

02 PETROLEUM↗

A Sustainable and Environmentally Friendly Concrete for Structural Applications

The purpose of this study is to utilize waste products—precipitated calcium carbonate (PCC) and upcycled recycled concrete aggregate (upcycled RCA or UCA)—in civil works projects. To do so, tests must be performed to determine the engineering properties of the materials in which PCC and UCA are sequestered. PCC is a fine to coarse grain waste product generated during the production of sugar from sugar beets. UCA is produced from demolished and returned concrete by the extraction of primarily calcium and alkalinity. The study also includes the use of both PCC and UCA in the same concrete mix design. The test results on PCC alone show that the optimum content to achieve a minimum 28 MPa (4000 psi) compressive strength is 25% and 30%. The corresponding compressive strength of mixes in which conventional aggregate was replaced by UCA is about 48 MPa (7000 psi) to 55 MPa (8000 psi) at the same water: cement ratio (0.44) by weight. The compressive strength of concrete with 25% to 30% cement replaced by PCC and varying aggregates replaced with UCA ranges from 19.3 to 40 MPa (2800 to 5800 psi). Other tests on PCC and UCA include tensile strength of 2 to 3 MPa (293 to 423 psi) and flexural strength of 1.3 to 1.9 MPa (183 to 279 psi). Analytical techniques such as X-ray diffraction (XRD), energy-dispersive X-ray spectrometry (EDX), and scanning electron microscopy (SEM) were used to identify the constituent elements and chemical compounds present in PCC, including calcium carbonate and silica. Based on the test results, the composition of PCC by weight indicates 45.9% calcium, 39.4% oxygen, and 9.2% carbon. Based on the results of this study, we can expect to reduce carbon emissions in the production of cement and aggregates, as well as utilize waste products in the civil engineering field.

42 ENGINEERING↗

Development of an MEMS ultrasonic microphone array system and its application to compressed wavefield imaging of concrete

Abstract Although contactless ultrasonic wavefield imaging shows potential for effective nondestructive inspection of various engineering materials, it has been rarely applied to concrete materials owing to technical challenges including low signal-to-noise ratio (SNR) caused by inherent heterogeneity of concrete. This paper presents development of a multi-channel MEMS ultrasonic microphone array system and its application to compressed wavefield imaging of concrete materials. The developed multi-channel MEMS ultrasonic microphone array system contains eight MEMS ultrasonic microphone elements and a signal conditioning circuit that enables measurements of ultrasonic signals with high SNR. A compressed sensing approach, based on the multiple measurement vector (MMV) concept, is applied to reconstruct a full dense ultrasonic wavefield data from sparsely sampled ultrasonic wavefield data. Experiments are carried out on a laboratory concrete sample to verify the performance of the developed MEMS microphone array system and proposed compressed sensing approach and then large-scale concrete samples to demonstrate practical application. The experimental results demonstrate that the developed MEMS microphone array system provides high-quality (SNR > 20 dB) ultrasonic data collected from concrete elements; furthermore, the proposed compressed sensing approach provides accurate reconstruction of dense wavefield data, as determined by peak signal-to-noise ratio (PSNR), from sparsely measured wavefield data with compression ratios up to 85% and PSNR above 25 dB in data collected form realistic large-scale concrete samples. By combining the MEMS array system and compressed sensing approach, the total ultrasonic data acquisition time needed to produce dense wavefield data can be significantly reduced.

Instruments & Instrumentation↗

Hybrid continuum–molecular modelling of multiscale internal gas flows

We develop and apply an efficient multiscale method for simulating a large class of low-speed internal rarefied gas flows. The method is an extension of the hybrid atomistic–continuum approach proposed by Borg et al. (2013) [28] for the simulation of micro/nano flows of high-aspect ratio. The major new extensions are: (1) incorporation of fluid compressibility; (2) implementation using the direct simulation Monte Carlo (DSMC) method for dilute rarefied gas flows, and (3) application to a broader range of geometries, including periodic, non-periodic, pressure-driven, gravity-driven and shear-driven internal flows. The multiscale method is applied to micro-scale gas flows through a periodic converging–diverging channel (driven by an external acceleration) and a non-periodic channel with a bend (driven by a pressure difference), as well as the flow between two eccentric cylinders (with the inner rotating relative to the outer). In all these cases there exists a wide variation of Knudsen number within the geometries, as well as substantial compressibility despite the Mach number being very low. For validation purposes, our multiscale simulation results are compared to those obtained from full-scale DSMC simulations: very close agreement is obtained in all cases for all flow variables considered. Our multiscale simulation is an order of magnitude more computationally efficient than the full-scale DSMC for the first and second test cases, and two orders of magnitude more efficient for the third case.

97 MATHEMATICS AND COMPUTING↗

A study of laser induced ignition of methane–air mixtures inside a Rapid Compression Machine

We present herein a fundamental study of laser ignition of methane/air mixtures at temperatures and pressures representative of an internal combustion engine. An Nd:YAG laser operating at λ = 1064 nm was used to ignite methane/air mixtures at equivalence ratios of 0.4 ≤ Φ ≤ 1 in a Rapid Compression Machine (RCM). Experiments were conducted to study the lean limit, minimum spark energy (MSE), and minimum ignition energy (MIE). The results show that laser ignition exhibits a stochastic behavior which must be interpreted statistically. A 90% probability of occurrence was used to evaluate the MSE and MIE, which resulted in MSE 90 =2.3 mJ and MIE 90 =7.2 mJ at an equivalence ratio Φ = 0.4 at compressed pressure and temperature of P comp = 29 bar and T comp = 750 K, respectively. The lean limit was characterized based on the fraction of chemical energy converted into thermal energy, which was determined by calculating the apparent rate of heat release as derived from RCM high speed pressure data. A lean limit for 90% chemical energy conversion was found to correspond to an equivalence ratio of 0.47 (T comp = 782 K). Schlieren photography was employed as a diagnostics tool to visualize the flame initiation and propagation inside the RCM.

42 ENGINEERING↗

Effect of Curing Environment on the Performance Properties of Saltstone - 13335

At the Savannah River Site (SRS), the low level radioactive waste (LLW) salt solution is immobilized as a cementitious waste form known as Saltstone. Depending on the Saltstone formulation, disposal unit size, environmental conditions and pour schedule, the waste form temperature, due to exothermic hydration reactions, can gradually increase by 30 deg. C to 50 deg. C above the starting temperature. Previous studies at Savannah River National Laboratory (SRNL) have shown that curing temperature has a negative impact on the hydraulic conductivity and other performance properties of Saltstone; specifically, these studies have shown that curing at elevated temperatures results in faster hydraulic conductivities than what is modeled in the Saltstone Performance Assessment (PA). SRNL is currently testing the performance of laboratory prepared Saltstone cured under controlled conditions (i.e. controlling relative humidity). The PA assumes that the Saltstone remains saturated; therefore, some samples are being kept completely saturated while others have a surface exposed to a high humidity environment. The formulation of these samples has been varied to continue studying the impact of processing parameters on the performance properties of Saltstone. The final water to premix (w/p) ratio of the Saltstone formulation does affect the density, porosity, and compressive strength of the cured Saltstone. The Saltstone formulations with 0.59 w/p ratios and lower had higher densities, lower porosities, and higher compressive strength than samples formulated at a higher w/p ratio. There is a general trend that the samples formulated at high w/p ratios (0.67 and higher) have the lowest density, highest porosity and lowest strength. However, for hydraulic conductivity, the curing environment had a greater effect on the results than the formulation. Therefore, the impact of elevated temperature is not as detrimental to the performance of the waste form as originally concluded, provided the curing environment is controlled and the waste form is not dried out. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thickness-dependent optical properties in compressively strained BiFeO{sub 3}/LaAlO{sub 3} films grown by pulsed laser deposition

Graphical abstract: - Highlights: • BFO with various thicknesses was grown on LAO substrates by pulsed laser deposition. • The structure and compressive strains were clarified via Raman scattering. • The charge transfer excitation was blue shifted with increasing compressive strain. • The compressive strain affects the distortion of Fe{sup 3+} local environment and O 2p states. - Abstract: Bismuth ferrite (BiFeO{sub 3}) films with various thicknesses were epitaxially grown on LaAlO{sub 3} substrates by pulsed laser deposition. The X-ray diffraction and Raman scattering spectra reveal that the films were highly (11{sup ¯}1) oriented with the single phase. With increasing the thickness, the compressive strain decreases and the strain ratios between the film and bulk crystal are evaluated to be 1.75, 1.57, and 1. Moreover, the compressive strain induces band gap shrinkage from 2.7 to 2.65 eV, while the charge transfer transition energy increases from 3.5 to 4.1 eV. It could be due to the shift of O 2p states and the variation of local Fe{sup 3+} crystal field.

36 MATERIALS SCIENCE↗

A Rapid Compression Machine Study of 2-Phenylethanol Autoignition at Low-To-Intermediate Temperatures

To meet the increasing anti-knocking quality demand of boosted spark-ignition engines, fuel additives are considered an effective approach to tailor fuel properties for satisfying the performance requirements. Thus, screening/developing bio-derived fuel additives that are best-suited for advanced spark-ignition engines has become a significant task. 2-Phenylethanol (2-PE) is an attractive candidate that features high research octane number, high octane sensitivity, low vapor pressure, and high energy density. Recognizing that the low temperature autoignition chemistry of 2-PE is not well understood and the need for fundamental experimental data at engine-relevant conditions, rapid compression machine (RCM) experiments are therefore conducted herein to measure ignition delay times (IDTs) of 2-PE in air over a wide range of conditions to fill this fundamental void. These newly acquired IDT data at low-to-intermediated temperatures, equivalence ratios of 0.35–1.5, and compressed pressures of 10–40 bar are then used to validate the 2-PE model developed by Shankar et al. (2017). It is found that this literature model greatly overpredicts the current RCM data. The comparison of experimental and simulated results also provides insights into 2-PE autoignition behaviors at varying conditions. Further chemical kinetic analyses demonstrate that the absence of the O2-addition pathway of β-R. radical in the 2-PE model of Shankar et al. (2017) could account for the model discrepancies observed at low-to-intermediated temperatures.

Fang, Ruozhou (ORCID:0000000348315100)↗

Characterization of coal extracts and their performances as binder for new carbon-based structural units

Coal production and usage have been declining in the past decade due to the transition to renewable energies, environmental regulations to reduce environmental pollution due to direct coal combustion from coal-fired power stations, and administrative policies. This downturn has created tremendous challenges for the coal industry, and many states rely on revenue from coal mining. Developing new valorization routes with high coal demand is essential and using coal-derived materials to make engineered products does offer an eco-friendly, attractive, and value-added use. This paper presents a brief introduction to the extraction process to derive coal deposits, extracts, and residuals (CDERs) and a comprehensive characterization analysis to determine the suitability of CDERs as binders to produce an innovative construction material named the carbon-based structural unit (CSU). CDERs are used to prepare the CSU with or without using mesophase pitch (MP) as binders and selected CDERs are heat-treated and pressure-heat-treated to improve their binding capabilities. The performances of the CSU specimens are evaluated based on compressive strength, density, and thermal conductivity. The CSU specimens mixed with distilled residue (DR) to pyrolysis char (PC) ratio of 1:2 achieve a compressive strength of 54.85 MPa, which is higher than the compressive strength of 30 MPa of normal concrete. The CSU specimens with deposit (De) and tetralin insoluble (TI) require the addition of MP to obtain compressive strengths greater than 30 MPa. Furthermore, these CSU specimens possess a relatively low density of about 1 g/cm 3 and low thermal conductivity of less than 0.25 W/m.K.

36 MATERIALS SCIENCE↗

Autoignition of n-decane under elevated pressure and low-to-intermediate temperature conditions

An experimental investigation of the autoignition for various n-decane/oxidizer mixtures is conducted using a rapid compression machine, in the range of equivalence ratios of {phi}=0.5-2.2, dilution molar ratios of N{sub 2}/(O{sub 2} + N{sub 2}) = 0.79-0.95, compressed gas pressures of P{sub C}=7-30 bar, and compressed gas temperatures of T{sub C}=635-770 K. The current experiments span a temperature range not fully investigated in previous autoignition studies on n-decane. Two-stage ignition, characteristic of large hydrocarbons, is observed over the entire range of conditions investigated, as demonstrated in the plots of raw experimental pressure traces. In addition, experimental results reveal the sensitivity of the first-stage and total ignition delays to variations in fuel and oxygen mole fractions, pressure, and temperature. Predictability of two kinetic mechanisms is compared against the present data. Discrepancies are noted and discussed, which are of direct relevance for further improvement of kinetic models of n-decane at conditions of elevated pressures and low-to-intermediate temperatures. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low Cost, High Efficiency, Ultra-Low NOx ARICE Solution Using HCCI Combustion

This report documents the development of a Homogeneous Charge Compression Ignition engine for the Advanced Reciprocating Internal Combustion Engine Program of the California Energy Commission. The goal of this research project was to develop and demonstrate a homogeneous charge compression ignition internal combustion engine for stationary power generation applications meeting the advanced reciprocating internal combustion engine program efficiency and emissions goals, primarily the development of a 200 kilowatt engine operating at 45 percent efficiency with 0.015 grams/brake horse power hour nitrogen oxide emissions. While this project did not attain this goal, innovative solutions were developed to many of the technical barriers that prevent homogeneous charge compression ignition from being a practical combustion system for the stationary power generation marketplace. The project focused on converting a Caterpillar 6-cylinder engine model 3406 natural gas generator set to operate in natural gas homogeneous charge compression ignition mode. A key challenge of homogeneous charge compression ignition is control of combustion. A novel system for control of the engine was developed based on thermal management, where recovered heat from the engine exhaust was used to control intake air temperature. Controlling intake air temperature allows control of the timing of the homogeneous charge compression ignition combustion process, and a specially designed dual intake manifold system allowed for control of the engine on a cylinder-by-cylinder basis. Control of fuel-air ratio is another significant technical issue in homogeneous charge compression ignition combustion, and is especially difficult with natural gas fuelled engines. A novel approach to fuel-air ratio control was developed by modifying a conventional natural gas carburetor and coupling it with an electronic pressure regulator, allowing for precise control of fuel-air ratio. Startup is challenging for homogeneous charge compression ignition engines, most strategies proposed involve starting the engine in conventional operation (i.e., spark-ignition), then transition to homogeneous charge compression ignition once the engine is started. The transition approach invites hazards, because the spark-ignition operating regime (fuel- air ratio) is not compatible with homogeneous charge compression ignition operating regime. An approach has been developed to start the engine directly in homogeneous charge compression ignition mode, avoiding operation in regimes that could be potentially hazardous. The technical accomplishments of this project lay the groundwork for future development of practical homogeneous charge compression ignition engines.

03 NATURAL GAS↗

Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner

Purpose: Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and detector during the scan would result in unacceptable loss of primary radiation. However, in the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis, the tube and detector rotate around a common axis, thereby maintaining a fixed tube-detector alignment. This C-arm geometry raises the possibility of using a 2D (cellular) focused antiscatter grid. The purpose of this study is to assess change in image quality when using an antiscatter grid in the DBT portion of a DMT scan under conditions of fixed radiation dose. Methods: Two 2D focused prototype grids with 80 cm focal length were tested, one stack-laminated from copper (Cu) and one cast from a tungsten-polymer (W-poly). They were reciprocated using a motion scheme designed to maximize transmission of primary x-ray photons. Grid-in and grid-out scatter-to-primary ratios (SPRs) were measured for rectangular blocks of material simulating 30%, 50%, and 70% glandular tissue compositions. For assessment of changes in image quality through the addition of a grid, the Computerized Imaging Reference Systems, Inc., phantom Model 011A containing a set of 1 cm thick blocks simulating a range of glandular/adipose ratios from 0/100 to 100/0 was used. To simulate 6.5 and 8.5 cm thick compressed breasts, 1 cm thick slices of PMMA were added to the Model 011A phantom. DBT images were obtained with and without the grid, with exposure parameters fixed for a given compressed thickness. Signal-difference-to-noise ratios (SDNRs), contrast, and voxel value-based attenuation coefficients (μ) were measured for all blocks from reconstructed phantom images. Results: For 4, 6, and 8 cm tissue-equivalent block phantom thicknesses, the inclusion of the W-poly grid reduced the SPR by factors of 5, 6, and 5.8, respectively. For the same thicknesses, the copper grid reduced the SPR by factors of 3.9, 4.5, and 4.9. For the 011A phantom, the W-poly grid raised the SDNR of the 70/30 block from 0.8, −0.32, and −0.72 to 0.9, 0.76, and 0.062 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. It raised the SDNR of the 100/0 block from 3.78, 1.95, and 1.0 to 3.79, 3.67, and 3.25 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. Inclusion of the W-poly grid improved the accuracy of image-based μ values for all block compositions. However, smearing of attenuation across slices due to limited angular sampling decreases the sensitivity of voxel values to changing composition compared to theoretical μ values. Conclusions: Under conditions of fixed radiation dose to the breast, use of a 2D focused grid increased contrast, SDNR, and accuracy of estimated attenuation for mass-simulating block compositions in all phantom thicknesses tested, with the degree of improvement depending upon material composition. A 2D antiscatter grid can be usefully incorporated in DBT systems that employ fully isocentric tube-detector rotation.

60 APPLIED LIFE SCIENCES↗