Energy spectrum of one-particle excitations in liquid dielectrics under high pressures and temperatures

The effect of pressure on the conductivity of molecular liquids (hydrogen, oxygen, and nitrogen) and alkali metals (cesium and rubidium) in the region of the experimentally observed dielectric-metal transition is investigated. It is shown that capture of free electrons by atoms or molecules (resulting in the formation of negative ions) is advantageous from the point of view of energy in liquids under moderately high pressures and temperatures. In spite of the fact that the ionization potential increases with density, the energy of an electron transition to the level of the negative ion decreases and, hence, the forbidden gap also decreases. For high densities, the level of negative ions is broadened and transformed into the conduction band. It is assumed that the exponential dependence of conductivity on density and temperature in the transition region is associated with transfer of quasi-free electrons located at the level of atomic negative ions. The spectrum of negative ions of hydrogen, oxygen, and cesium in the strongly compressed state is determined, and the forbidden gap calculated for these substances is found to be in good agreement with the results obtained for hydrogen and oxygen in single shock-wave experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization and CST Batch Contact Equilibrium Testing of Modified Tank 9H Process Supernate Samples in Support of TCCR

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with crystalline silicotitanate (CST) media to process radioactive waste solutions for the removal of ¹³⁷Cs. TCCR currently focuses on dissolving Savannah River Site (SRS) radioactive tank waste (primarily sodium saltcake solids) within Tank 10H followed by at-tank ion exchange column treatment. Two supernate batches from Tank 10H have been processed through the TCCR unit and processing of a third batch is expected soon. After processing of this supernate batch, plans are to replace the CST columns and process dissolved salt solution from Tank 9H through Tank 10H and then through the new CST columns installed in the TCCR unit. The new columns are expected to contain either a media similar to an archived CST batch (IE-911) or the R9120-B CST media used in the current TCCR columns (the two materials are fundamentally the same; just different specifications, product names, and preconditioning steps). Samples of Tank 9H dissolved saltcake were received at the Savannah River National Laboratory (SRNL) and characterized. The Tank 9H supernate contained a high sodium concentration (~9.6 M Na⁺) and will require dilution to near 6 M [Na⁺] prior to processing through the TCCR unit. The cesium concentration in Tank 9H is currently significantly higher than was observed with Tank 10H. Three dilutions of the Tank 9H supernate were conducted to mimic possible dilutions that could be conducted in the tank farm prior to TCCR processing using inhibited water, sodium hydroxide, and sodium nitrate solutions. Dilution #1 was prepared by diluting the Tank 9H supernate by a factor of 1.6 with inhibited water, Dilution #2 was prepared by diluting the Tank 9H supernate by a factor of 3.7 with a mixed sodium hydroxide/sodium nitrate diluent, and Dilution #3 was prepared by also diluting by a factor of 3.7 but with sodium hydroxide only. All three dilutions have similar Na⁺ concentrations (~6 M), but Dilutions #2 and #3 contain significantly less cesium. Major and key minor components of the diluted Tank 9H supernate samples are provided in Table ES-1. Batch contact equilibrium tests were conducted with the Tank 9H dilutions and the two different CST media batches being considered for use in the new TCCR columns. Results are summarized in Table ES-2 and compared to ZAM model predictions. The highest cesium distribution coefficient and percent removal were observed with Dilution #3. IE-911 CST (an archived CST media batch) was more effective at removing cesium than the more recently prepared R9120-B CST media, though both media samples removed >88% of the cesium and the differences may not be statistically different considering the overall uncertainty. Based on the results, maximum cesium loadings were calculated for each CST media type and Tank 9H dilution. In general, maximum cesium loadings from dilutions of this supernate batch are quite high (approaching 0.1 mmol total Cs⁺/g CST for Dilution #1). The highest calculated maximum ¹³⁷Cs loading for the Tank 9H dilutions using the ZAM model with input of the tank compositions and batch contact results was 207 Ci/kg CST (Dilution #1 with IE-911 CST). In all cases, higher maximum cesium loading values were predicted for IE-911 CST versus R9120-B, although the differences varied considerably between the dilutions. The maximum loading value for IE-911 CST with Tank 9H Dilution #1 was only 7% higher than the maximum loading for R9120-B. The maximum loading value for IE-911 CST with Dilution #3 was 24% higher than the maximum loading for R9120-B. Dilution #2 was intermediate between these values. Note that these maximum loading values are the theoretical calculated values, and actual operating conditions will cause differences. A CST binder dilution (correction) factor near 0.7 (relative to pure powder CST) was required for each batch contact test with IE-911 engineered CST using the three Tank 9H dilutions. Correction factors calculated for R9120-B CST ranged from 0.56 to 0.66 for the three dilutions. Following the batch contact tests, the CST samples were isolated from the Tank 9H solution, washed, dried, and digested in acid following established procedures. The analysis results are provided in Table ES-3. Total cesium loading values determined by CST digestion were similar to the calculated loading values based on solution analysis (Table ES-2) for all samples. In addition, the CST was observed to load calcium (R9120-B sample only), iron, strontium, lead, uranium, and plutonium after contact with the waste supernate, as has been observed previously.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ROBUSTNESS OF THE CSSX PROCESS TO FEED VARIATION: EFFICIENT CESIUM REMOVAL FROM THE HIGH POTASSIUM WASTES AT HANFORD

This contribution finds the Caustic-Side Solvent Extraction (CSSX) process to be effective for the removal of cesium from the Hanford tank-waste supernatant solutions. The Hanford waste types are more challenging than those at the Savannah River Site (SRS) in that they contain significantly higher levels of potassium, the chief competing ion in the extraction of cesium. By use of a computerized CSSX thermodynamic model, it was calculated that the higher levels of potassium depress the cesium distribution ratio (D{sub Cs}), as validated to within {+-}11% by the measurement of D{sub Cs} values on various Hanford waste-simulant compositions. A simple analog model equation that can be readily applied in a spreadsheet for estimating the D{sub Cs} values for the varying waste compositions was developed and shown to yield nearly identical estimates as the computerized CSSX model. It is concluded from the batch distribution experiments, the physical-property measurements, the equilibrium modeling, the flowsheet calculations, and the contactor sizing that the CSSX process as currently formulated for cesium removal from alkaline salt waste at the SRS is capable of treating similar Hanford tank feeds, albeit with more stages. For the most challenging Hanford waste composition tested, 31 stages would be required to provide a cesium decontamination factor (DF) of 5000 and a concentration factor (CF) of 2. Commercial contacting equipment with rotor diameters of 10 in. for extraction and 5 in. for stripping should have the capacity to meet throughput requirements, but testing will be required to confirm that the needed efficiency and hydraulic performance are actually obtainable. Markedly improved flowsheet performance was calculated based on experimental distribution ratios determined for an improved solvent formulation employing the more soluble cesium extractant BEHBCalixC6 used with alternative scrub and strip solutions, respectively 0.1 M NaOH and 0.010 M boric acid. The improved solvent and flowsheet can meet minimum requirements (DF = 5000 and CF = 2) with 15 stages or more ambitious goals (DF = 40,000 and CF = 15) with 19 stages. Thus, a modular CSSX application for the Hanford waste seems readily obtainable with further short-term development.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Batch Contact Equilibrium Testing of Crystalline Silicotitanate (CST) Sieve Cuts in SRS Average Simulant and Examination of CST Samples Aged in Caustic and Simulant in Support of Tank Closure Cesium Removal 1A (TCCR-1A)

Batch contact testing to determine cesium equilibrium loading on Crystalline Silicotitanate ion exchange media in Savannah River Site Average Waste Simulant at 25 °C indicated that smaller diameter particles isolated by sieving pretreated CST media may load slightly higher (<10%) amounts of cesium, though the differences are within analytical uncertainty. In addition, ion exchange media sub-samples stored in 2-4 M NaOH and caustic simulant solutions for ~2.5 years were examined by optical microscopy and the 3 M NaOH sample was also analyzed to determine whether changes in the particle size distribution occurred during storage. No visual indications of particle attrition or agglomeration were observed for any sample. Particle size analysis indicated that a slight decrease occurred in the average particle diameter following contact with 3 M NaOH (541 µm average diameter versus 566 µm for the pretreated CST prior to contact). A small increase (from 0 to <0.5 wt. %) in the number of particles ranging from 271 and 322 µm was also observed for the CST sample contacted with 3 M NaOH relative to a sample of the original pretreated material. However, this small change could be due to sub-sampling differences or analytical uncertainty. It does not appear that small particles are formed to a significant degree during CST caustic contact or that small particles which do form (presumably from attrition of larger particles during pretreatment) load significantly more cesium than the bulk material. Minimal other negative consequences were observed associated with CST extended caustic or simulant contact, except for the tendency for more concentrated salt solutions to form some salt crystals which deposit on the media over time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Helicon plasma generator-assisted surface conversion ion source for the production of H{sup -} ion beams at the Los Alamos Neutron Science Center

The converter-type negative ion source currently employed at the Los Alamos Neutron Science Center (LANSCE) is based on cesium enhanced surface production of H{sup -} ion beams in a filament-driven discharge. In this kind of an ion source the extracted H{sup -} beam current is limited by the achievable plasma density which depends primarily on the electron emission current from the filaments. The emission current can be increased by increasing the filament temperature but, unfortunately, this leads not only to shorter filament lifetime but also to an increase in metal evaporation from the filament, which deposits on the H{sup -} converter surface and degrades its performance. Therefore, we have started an ion source development project focused on replacing these thermionic cathodes (filaments) of the converter source by a helicon plasma generator capable of producing high-density hydrogen plasmas with low electron energy. In our studies which have so far shown that the plasma density of the surface conversion source can be increased significantly by exciting a helicon wave in the plasma, and we expect to improve the performance of the surface converter H{sup -} ion source in terms of beam brightness and time between services. The design of this new source and preliminary results are presented, along with a discussion of physical processes relevant for H{sup -} ion beam production with this novel design. Ultimately, we perceive this approach as an interim step towards our long-term goal, combining a helicon plasma generator with an SNS-type main discharge chamber, which will allow us to individually optimize the plasma properties of the plasma cathode (helicon) and H{sup -} production (main discharge) in order to further improve the brightness of extracted H{sup -} ion beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long pulse production of high current D{sup -} ion beams in the JT-60 negative ion source

The first long pulse production of high power D{sup -} ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D{sup -} ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D{sup -} ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D{sup -} ion beams of 12.5 and 9.8 A were produced at 340 keV with cesium seeding at a rate of {approx}14 {mu}g/s into the ion sources. The pulse duration of these D{sup -} ion beams was extended step by step, and then was successfully extended up to 18 s without degradation of the negative ion production. The D{sup -} ion beams were neutralized to yield 3.6 MW D{sup 0} beams by a gas cell, and then injected into the JT-60 U plasma. Further, a slight reduction of D{sup -} ion beam power allowed the longer injection duration of 21 s at a D{sup 0} beam power of 3.2 MW. The success in the long pulse production of a high power D{sup -} ion beam shows that negative ion beams can be produced during a few tens of seconds without degradations of negative ion production and the voltage holding in a large Cs-seeded negative ion source.

43 PARTICLE ACCELERATORS↗

Time evolution of negative ion profile in a large cesiated negative ion source applicable to fusion reactors

To understand the physics of the cesium (Cs) recycling in the large Cs-seeded negative ion sources relevant to ITER and JT-60SA with ion extraction area of 45-60 cm × 110-120 cm, the time evolution of the negative ion profile was precisely measured in JT-60SA where the ion extraction area is longitudinally segmented into 5. The Cs was seeded from the oven at 180 °C to the ion source. After 1 g of Cs input, surface production of the negative ions appeared only in the central segment where a Cs nozzle was located. Up to 2 g of Cs, the negative ion profile was longitudinally expanded over full ion extraction area. The measured time evolution of the negative ion profile has the similar tendency of distribution of the Cs atoms that is calculated. From the results, it is suggested that Cs atom distribution is correlated with the formation of the negative ion profile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Caustic-Side Solvent-Extraction Modeling for Hanford Interim Pretreatment System

The purpose of this work is to examine the applicability of the Caustic-Side Solvent Extraction (CSSX) process for the removal of cesium from Hanford tank-waste supernatant solutions in support of the Hanford Interim Pretreatment System (IPS). The Hanford waste types are more challenging than those at the Savannah River Site (SRS) in that they contain significantly higher levels of potassium, the chief competing ion in the extraction of cesium. It was confirmed by use of the CSSX model that the higher levels of potassium depress the cesium distribution ratio (DCs), as validated by measurement of DCs values for four of eight specified Hanford waste-simulant compositions. The model predictions were good to an apparent standard error of ±11%. It is concluded from batch distribution experiments, physical-property measurements, equilibrium modeling, flowsheet calculations, and contactor sizing that the CSSX process as currently employed for cesium removal from alkaline salt waste at the SRS is capable of treating similar Hanford tank feeds. For the most challenging waste composition, 41 stages would be required to provide a cesium decontamination factor (DF) of 5000 and a concentration factor (CF) of 5. Commercial contacting equipment with rotor diameters of 10 in. for extraction and 5 in. for stripping should have the capacity to meet throughput requirements, but testing will be required to confirm that the needed efficiency and hydraulic performance are actually obtainable. Markedly improved flowsheet performance was calculated for a new solvent formulation employing the more soluble cesium extractant BEHBCalixC6 used with alternative scrub and strip solutions, respectively 0.1 M NaOH and 10 mM boric acid. The improved system can meet minimum requirements (DF = 5000 and CF = 5) with 17 stages or more ambitious goals (DF = 40,000 and CF = 15) with 19 stages. Potential benefits of further research and development are identified that would lead to reduced costs, greater adaptability of the process to DOE alkaline salt wastes, and greater readiness for implementation. Such benefits accrue from optimal sizing of centrifugal contactors for application of the CSSX process for the IPS; more accurate modeling of cesium extraction with greater flexibility and applicability to a variety of feeds and flowsheet conditions; and further improving and optimizing the alternative CSSX solvent and scrub/strip system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crystalline Silicotitanate (CST) Ion Exchange Media Performance Evaluations in SRS Average Supernate Simulant and Tank 10H Waste Solution to Support TCCR

Savannah River Remediation (SRR) is deploying an “at-tank” ion exchange process to remove radioactive cesium from waste supernate which is referred to as the Tank Closure Cesium Removal (TCCR) system utilizing Crystalline Silicotitanate (CST) media. After being loaded with cesium, but before flushed and dried and sent to Interim Safe Storage (ISS), it is anticipated that the TCCR ion exchange columns will be taken off-line (stagnant) with the CST media still immersed in supernate. The currently designed columns include no active cooling system during processing (although no rmal process fluid flow through the column during operations provides significant cooling) or during off-line conditions and temperature increases are expected in the stagnant, loaded, and liquid-filled columns due to decay heat from the radionuclides absorbed to the CST. As a result, modification of the Tank 10H supernate composition has been considered through the addition of either NaOH or KOH reagents to decrease cesium loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs- 137. The TCCR project is currently focused on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently prepared CST media batches (9120-B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spectroscopic observations of beam and source plasma light and testing Cs-deposition monitor in the large area negative ion source for LHD-NBI

In the large area negative ion source for the LHD negative-ion-(H{sup -})-based neutral beam system, (I) we used the spectrometer to measure caesium lines in the source plasma during beam shots. (II) With Doppler-shifted measurements, the H{sub {alpha}} line at three different locations along the beam as well as the spectrum profile for cases of different plasma grid areas. (III) Caesium deposition monitor with a high speed shutter was tested to measure the weight of the deposited Cs layer. In the observation, cleaner spectra of Doppler-shifted H{sub {alpha}} line with only a small level of background light were obtained at a new observation port which viewed the blueshifted light in the drift region after the accelerator of a LHD ion source. Both the amounts of Cs I (852 nm, neutral Cs{sup 0}) and Cs II (522 nm, Cs{sup +}) in the source plasma light rose sharply when beam acceleration began, and continued rising during a 10 s pulse. It was thought that this was because the cesium was evaporated/sputtered from the source back plate by the back-streaming positive ions. Cs deposition rate to the crystal sensor measured by adjusting the shutter open time was evaluated to be 2.9 nanograms/s cm{sup 2} for preliminary testing. More neutral Cs tended to be evolved in the source after arc discharge. Much Cs could be consumed in a high rate-pulsed operation (such as LHD source)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status of the ELISE test facility

The test facility ELISE, equipped with a large radio frequency (RF) driven ion source (1×0.9 m2) of half the size of the ion source for the ITER neutral beam injection (NBI) system, is operational since beginning of 2013. The first experimental campaign was dedicated to a thorough qualification of the test facility and its diagnostic tools at low RF power (80 kW in total, i.e. 20 kW per driver) in volume operation, i.e. operation without cesium, where the negative hydrogen ion production is done in the plasma volume only. This paper reports on the main results of the second and third experimental campaigns, where Cs was inserted in the ion source for an enhancement of the negative ion production by the surface process. The second experimental campaign was done still with low RF power, both for hydrogen and deuterium, with pulse lengths of up to 500 s. The results of this campaign are rather encouraging, especially in hydrogen, where large current densities with respect to the low RF power could be achieved at a ratio of co-extracted electrons to extracted ions of 0.5-0.6 at the relevant source pressure of 0.3 Pa. Similar large extracted ion currents could be achieved also in deuterium, but with larger amounts of co-extracted electrons. The required ratio of co-extracted electrons to extracted ions of one could be achieved only in short pulses. The third experimental campaign aimed then for approaching the required ITER NBI parameters with respect to the ion and electron extracted currents, both for hydrogen and deuterium, by increasing the RF power with short pulses, i.e. beam-on times of up to 10 s and RF-on time up to 20 s. Current densities near the ITER NBI requirements could be achieved in hydrogen at a ratio of co-extracted electrons to extracted ions of 0.5-0.6 at the relevant source pressure of 0.3 Pa. As it was the case for the low RF operation, the required filter field was significantly lower than expected from the experience with the small prototype RF source. Similar large extracted ion currents could be achieved also in deuterium, but with larger amounts of co-extracted electrons; the main problem in deuterium operation are the non-stable currents of the co-extracted electrons, most probably caused by the high dynamic of the Cs redistribution in the system. The reasons for this larger instability are still under investigation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status of Plasma Electron Hose Instability Studies in FACET

In the FACET plasma-wakefield acceleration experiment a dense 23 GeV electron beam will interact with lithium and cesium plasmas, leading to plasma ion-channel formation. The interaction between the electron beam and the plasma sheath-electrons may lead to a fast growing electron hose instability. By using optics dispersion knobs to induce a controlled z-x tilt along the beam entering the plasma, we investigate the transverse behavior of the beam in the plasma as function of the tilt. We seek to quantify limits on the instability in order to further explore potential limitations on future plasma wakefield accelerators due to the electron hose instability. The FACET plasma-wakefield experiment at SLAC will study beam driven plasma wakefield acceleration. A dense 23 GeV electron beam will interact with lithium or cesium plasma, leading to plasma ion-channel formation. The interaction between the electron beam and the plasma sheath-electrons drives the electron hose instability, as first studied by Whittum. While Ref. [2] indicates the possibility of a large instability growth rate for typical beam and plasma parameters, other studies including have shown that several physical effects may mitigate the hosing growth rate substantially. So far there has been no quantitative benchmarking of experimentally observed hosing in previous experiments. At FACET we aim to perform such benchmarking by for example inducing a controlled z-x tilt along the beamentering the plasma, and observing the transverse behavior of the beam in the plasma as function. The long-term objective of these studies is to quantify potential limitations on future plasma wakefield accelerators due to the electron hose instability.

43 PARTICLE ACCELERATORS↗

HEAT TRANSFER ANALYSIS FOR ION-EXCHANGE COLUMN SYSTEM

Models have been developed to simulate the thermal characteristics of Crystalline Silicotitanate (CST) ion exchange media fully loaded with radioactive cesium in a column configuration and distributed within a waste storage tank. This work was conducted to support the Small Column Ion Exchange (SCIX) program which is focused on processing dissolved, high-sodium salt waste for the removal of specific radionuclides (including Cs-137, Sr-90, and actinides) within a High Level Waste (HLW) storage tank at the Savannah River Site. The SCIX design includes CST columns inserted and supported in the tank top risers for cesium removal. Temperature distributions and maximum temperatures across the column were calculated with a focus on process upset conditions. A two-dimensional computational modeling approach for the in-column ion-exchange domain was taken to include conservative, bounding estimates for key parameters such that the results would provide the maximum centerline temperatures achievable under the design configurations using a feed composition known to promote high cesium loading on CST. The current full-scale design for the CST column includes one central cooling pipe and four outer cooling tubes. Most calculations assumed that the fluid within the column was stagnant (i.e. no buoyancy-induced flow) for a conservative estimate. A primary objective of these calculations was to estimate temperature distributions across packed CST beds immersed in waste supernate or filled with dry air under various accident scenarios. Accident scenarios evaluated included loss of salt solution flow through the bed, inadvertent column drainage, and loss of active cooling in the column. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature.

42 ENGINEERING↗

Structural differences of metal biphenylenebisphosphonate with change in the alkali metal

A series of monovalent biphenylenebisphosphonates have been prepared using hydrothermal synthesis resulting in a composition M[HO{sub 3}PC{sub 12}H{sub 8}PO{sub 3}H{sub 2}] where M=Li{sup +}, Na{sup +}, K{sup +}, Rb{sup +}, and Cs{sup +}. Three of the original four phosphonic acid protons are retained, making the compounds Broensted acids. A synthesis using microwave irradiation results in a new compound, Na{sub 2}(HO{sub 3}PC{sub 12}H{sub 8}PO{sub 3}H), where only two protons are retained. Two structural types were found for the three-dimensional compounds where one type has a continuous inorganic layer. In the other structural type, the inorganic layer is formed by hydrogen bonding between neighboring chains. These structural variations arise as the coordination number changes from 4 for lithium to 8 for cesium without change in composition. The dense packing of the biphenylenebisphosphonate restricts the access to the protons, thus these compounds cannot be used as Broensted acid catalysts. Alternatively, addition of N,N-dimethylformamide to the reaction mixture results in inclusion of ammonium ions in the cavities. - Graphical abstract: Two of five metal biphenylenebisphosphonate structures (lithium (a) and cesium (b)) are presented. Each compound is a potential Bronsted acid catalyst, where three of the original four protons are retained from the biphenylenebisphosphonic acid. Highlights: Black-Right-Pointing-Pointer Alkali phosphonates are Broensted acids with the retention of three protons per alkali cation. Black-Right-Pointing-Pointer These compounds are thermally stable to approximately 300 Degree-Sign C. Black-Right-Pointing-Pointer A new structure was formed from the in situ synthesis with dimethylformamide as a reactant. Black-Right-Pointing-Pointer With lack of access to the protons the alkali phosphonates cannot function as a Bronsted acid catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RESORCINOL-FORMALDEHYDE ION EXCHANGE RESIN CHEMISTRY FOR HIGH LEVEL WASTE TREATMENT

A principal goal at the Savannah River Site is to safely dispose of the large volume of liquid nuclear waste held in many storage tanks. In-tank ion exchange technology is being considered for cesium removal using a polymer resin made of resorcinol formaldehyde that has been engineered into microspheres. The waste under study is generally lower in potassium and organic components than Hanford waste; therefore, the resin performance was evaluated with actual dissolved salt waste. The ion exchange performance and resin chemistry results are discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of useful ion yield for Si in GaN by secondary ion mass spectrometry

The optimum detection levels that can be achieved by a secondary ion mass spectrometer are dependent on how efficiently a particular species of interest can be ionized and detected. One can determine in advance whether the analysis of a particular ion in the sample is possible, if the useful ion yield is known. The useful ion yield depends on the element, instrument transmission, the analytical conditions, the sample matrix, etc. The value of the useful ion yield for a species can diverge from one instrument type to another due to its different transmission and ionization probabilities. However, the same tendencies in the results may be expected for all types of instruments. In this paper, the authors present a quantitative secondary ion mass spectrometry analysis of the useful ion yield for the silicon dopant species in a gallium nitride matrix grown by metal organic chemical vapor deposition. Positively ionized cesium was used as the primary ion beam, and its energy was varied in the range from 0.5 to 5 kV. A quadrupole mass analyzer was utilized to collect secondary ion species of interest. The analysis results can be used to determine the primary beam energies for optimal Si sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗