Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Base stations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

RELAP-7 Application and Enhancement for FLEX Strategies and ATF Behavior under Extended Loss of AC Power Conditions

This report summarizes the results of a three-year research project sponsored by the U.S. Department of Energy (DOE) Nuclear Energy University Program (NEUP) to enhance and apply the RELAP-7 code by adding and improving several important components (e.g., a mechanistic Reactor Core Isolation Cooling (RCIC) system model) for thermal hydraulic studies of LWRs under ELAP conditions and evaluating the time available for transition to portable FLEX equipment. The project team included University of Massachusetts–Lowell, The Ohio State University, Texas A&M University, Idaho National Laboratory and Oak Ridge National Laboratory. In the Fukushima accident, it was found that the RCIC system played a crucial role in delaying core meltdown by almost three days in Fukushima Daiichi Unit 2, because of self-regulated operation of the steam driven RCIC turbine-pump injection system. Steam flow in the convergent-divergent nozzles of the RCIC Terry turbine is two-phase non-equilibrium transonic flow with homogenous nucleation condensation. To more accurately predict the dynamic process and behavior of the transonic compressible steam flow, a one-dimensional transient two-phase analytical model is presented. A simplified four-fluid model was employed in the present work with the consideration of four separate fluid fields: vapor, liquid film, entrained droplets and condensed droplets. The mass, momentum and energy interactions between the fluids were considered and modeled. An extended seven-equation non-equilibrium critical flow model was developed to obtain the critical pressure and velocities of each phase at the nozzle throat. To predict the wetness in the divergent section, a mechanistic nucleation condensation model was integrated in the nozzle analysis model, considering the generation and consequent growth of droplets. The governing differential equations on a staggered grid were discretized using the second-order Lax-Wendroff scheme with a flux limiter, and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE) algorithm was employed to solve the discrete linear system. To demonstrate the predictability and reliability of the physical models and the numerical method proposed in the present work, three representative nozzles were modeled and simulated. The results show good agreement with the available experimental data, even for condensation shock. Then, the 1D nozzle model was employed to obtain nozzle flow tables of the Terry turbine nozzle for different working pressures which can cover the operation pressure range of the RCIC system. A mechanistic RCIC turbine-pump system model was developed and implemented in the system code TRACE to simulate dynamic responses of the RCIC system under Beyond Design Basis Accident (BDBA) conditions. The turbine-pump governing equations are based on the control volume approach of the angular momentum balance. The physics based mechanistic RCIC model was developed using the TRACE control system components (i.e., signal variables, control blocks, and tables), and incorporated into a TRACE boiling water reactor (BWR) model. The TRACE model in this report has a detailed nodalization of the reactor pressure vessel (RPV), and all of the major flow paths and system components, including the safety relief valves (SRVs) and the containment suppression pool and drywell. Based on the nozzle flow tables generated from the 1D nozzle model developed, the turbine drive torque can be calculated from table lookup. Since the detailed specifications of the RCIC pump are unavailable, the homologous curves for a Bingham pump were used in the current pump component. A station black-out (SBO) accident test problem was selected to demonstrate the TRACE RCIC model. The short-term SBO simulations were performed for two cladding materials: Zircaloy and FeCrAl, to demonstrate the effect of the accident tolerant fuel cladding on fuel heat-up under BDBA accident conditions. The wetwell plays a vital safety role in SBO and other BWR accident scenarios in that it can reduce containment pressure and supply additional core make-up water. The suppression pool temperature distribution has a very large impact on both RPV and containment pressure. Thus, another novel contribution of the project comes mainly from an improved, systems-level wetwell model which can capture buoyancy-induced thermal stratification effects due to steam injection and condensation. A two-zone stratified wetwell model has been implemented in RELAP-7 and some results from that model are presented. This wetwell model is capable of simulating thermal stratification due to a low steam mass injection rate. With a low mass flow rate, the model assumes that all the steam condenses within the pipe and the resulting plume can be approximated with a purely buoyant, heat-source driven model. The wetwell model developed with these assumptions is adequate to simulate slow transients such as extended SBO transients.

42 ENGINEERING↗

Evaluating Scalograms for Seismic Event Denoising

Denoising contaminated seismic signals for later processing is a fundamental problem in seismic signals analysis. The most straightforward denoising approach, using spectral filtering, is not effective when noise and seismic signal occupy the same frequency range. Neural network approaches have shown success denoising local signal when trained on short-time Fourier transform spectrograms (Zhu et al 2018; Tibi et al 2021). Scalograms, a wavelet-based transform, achieved ~15% better reconstruction as measured by dynamic time warping on a seismic waveform test set than spectrograms, suggesting their use as an alternative for denoising. We train a deep neural network on a scalogram dataset derived from waveforms recorded by the University of Utah Seismograph Stations network. We find that initial results are no better than a spectrogram approach, with additional overhead imposed by the significantly larger size of scalograms. A robust exploration of neural network hyperparameters and network architecture was not performed, which could be done in follow on work.

58 GEOSCIENCES↗

Ubiquitous Traffic Volume Estimation through Machine-Learning Procedure

Traffic volume data is one of the most important metrics for accurate assessment of the performance of a transportation system. Quality volume data is required to effectively assess extent of delay and congestion, detect real-time perturbations to the network, and understand traffic patterns during major weather events. Traffic volume on freeways are typically collected through continuous count stations installed by state DOTs, while there is lack of traffic volume observability on off-freeway roads. The National Renewable Energy Laboratory (NREL), in Collaboration with the I-95 Corridor Coalition and the University of Maryland, extended its research into estimating volumes anywhere anytime from industry probe based data for off-freeway roads. NREL combined vehicle probe count data with several other data sets (speed, whether, roadway geometry, time-of-day, day-of-week, etc.) to estimate hourly volumes as well as AADTs. The research validated and demonstrated the machine learning model, namely XGBoost, using data collected from Pennsylvania, North Carolina, and Tennessee.

47 OTHER INSTRUMENTATION↗

Critical Minerals from Waste Streams in the Powder River Basin of Wyoming and Montana, USA

Background/Objectives. Critical minerals (CM) are essential for numerous industrial and defense applications, including green technologies that will help to meet carbon emission reduction goals. Many CM are currently mined and processed in countries that lack stringent environmental and labor regulations. Unconventional sources such as existing industrial waste streams could play a part in building an ethical CM supply chain. Additionally, waste streams created in the extraction and processing of CM could be used for other industrial or commercial purposes, thereby reducing waste and advancing a circular economy. Approach/Activities. The Department of Energy funded Powder River Basin (PRB) CORE-CM project is exploring all aspects of the carbon ore, rare earth element (REE), and CM value chain, including the potential for extraction of CM from industrial waste streams in the basin. Waste streams that have potential as CM feedstocks are being inventoried to assess the concentration of CM in each waste stream and to estimate volume and accessibility. Although basin-specific technologies for extraction of CM are still in development, waste streams that may be produced during these processes are being cataloged and mapped to potential secondary uses. Results/Lessons Learned. Initial studies of the CM potential of PRB coal ash show that this waste stream contains concentrations of greater than 300 ppm total REE (Bagdonas et al., 2022, Renewable and Sustainable Energy Reviews). Moreover, calcium-rich PRB coal ash is amenable to REE extraction (Taggart et al., 2016, Environmental Science and Technology). Wyoming coal is shipped to 28 states, meaning that coal ash produced at power stations across the US represents a potential widespread resource for the extraction of REE. In addition to coal mining and coal fired electricity generation, the PRB is home to other energy industries including oil and gas production, in-situ uranium mining, and bentonite mining. Historically, precious and base metal mining has taken place on the perimeter of the PRB. Waste streams from these industries are currently being evaluated for their CM potential. Assessing the CM resource potential of waste streams could contribute to the development of an ethical CM supply chain. Results from these studies can be replicated for other waste streams, increasing the likelihood of successful creation of circular economies.

Phillips, Erin↗

Investigating the influence of latent lifestyles on productive travels: Insights into designing autonomous transit system

As a special case of multitasking, travel-based multitasking typically refers to conducting a set of in-vehicle activities while traveling. Travel-based multitasking has an indisputable influence on offering a pleasant travel experience to transit users during their rides, given that they can use their travel time to perform desirable activities and gain benefits in various form. For instance, the in-activities could help the rider free up time from his/her schedule for the day (i.e., a worthwhile use of travel time). In this study, we investigate how the worthwhileness of a travel-based multitasking could be under the influence of: (1) the transit user’s lifestyle, and (2) socio-demographics, and (3) the characteristics of the transit trip. Towards this, we conducted an intercept survey focusing on the transit trips in the Chicago metropolitan area and analyzed it using latent class modeling approach. Per the results, two classes of transit users could be identified: (1) worthwhileness seekers, productively travelers and (2) leisure seekers, occasional worthwhile travelers. The results also suggest travel time, waiting time and walking distance to the transit station, and the set of in-vehicle activities as significant predictors of worthwhile use of travel time. Finally, the findings provide insights to policymakers for improving public transit systems in the current form, as well as designing an autonomous mobility system as the future form of public transit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Architectural Survey of the REECo Maintenance Compound, Area 6, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to install a 26.45-mile-long 138-kilovolt (kV) transmission line on the Nevada National Security Site (NNSS) in Nye County, Nevada. This new transmission line will upgrade the electrical transmission system and provide reliable power between Mercury Switching Station in Area 23 and the U1a Facility in Area 1. The proposed upgrade to the power transmission system constitutes an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. A portion of this new transmission line will cross the western perimeter of the Reynolds Electrical and Engineering Company (REECo) Maintenance Compound located in Area 6 of the NNSS. This compound with its trade shops, storage sheds, and yards served as a general construction facility that supported nuclear testing activities on the NNSS from 1967 to 1992. Although three architectural resources in the compound have previously been recorded and evaluated for the National Register of Historic Places (NRHP), other resources within it have not, nor has the compound been recorded and evaluated as a potential district. The State Historic Preservation Officer (SHPO) concurred with NNSA/NFO’s determination that the unevaluated REECo Maintenance Compound will be adversely affected by the proposed undertaking (Reed 2021). The NNSA/NFO, in consultation with the SHPO, then developed the Memorandum of Agreement DE-GM58-22NA25553 between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Installation of a 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility and the Removal of the Historic 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility in Areas 1, 3, 5, 6, and 23 of the Nevada National Security Site, Nye County, hereafter referred to as the MOA. This architectural survey report was prepared in accordance with MOA Stipulation III.B. It describes the origins, history, layout, and functions of the REECo Maintenance Compound during the Cold War and identifies contributing and noncontributing resources. The report defines a district boundary based on archival research and the field survey and concludes with an appendix that presents digital color images of the compound with descriptions and a map key showing image viewpoints and directions. Although none of the architectural resources are recommended individually eligible, the district evaluation concludes the REECo Maintenance Compound is eligible as a historic district for listing in the NRHP under the Secretary of the Interior’s Significance Criteria A and C at the local level. The historic district retains all seven aspects of integrity and conveys its significance under the abovementioned criteria.

138 kV↗

Seismic Array Analysis Using Fiber-Optic Distributed Acoustic Sensing on Small Local and Regional Earthquakes

We examined the feasibility of using fiber-optic Distributed Acoustic Sensing (DAS) as an alternative to a traditional seismic array. Seismic arrays are used routinely globally to measure waveform propagation parameters and signal features including back-azimuth (BAZ) and apparent horizontal velocity through the process of beamforming or frequency-wavenumber (f-k) array analysis with the assumption that the signals travel across the array as a plane-wave. These measurements are useful for identifying signal detections as teleseismic, regional, or local distance seismic phases based on their velocities traveling across the array (e.g., Rost and Thomas, 2001). Signal enhancement is the main benefit of array processesing through the stacking of multiple channels as a phased array. This enhancement increases as the square root of the number of channels relative to a single seismic station (e.g., Rost and Thomas, 2001), which is a factor of 3 from a typical nine-channel array. DAS provides the potential of stacking waveforms from 100’s to 1000’s of channels. However, DAS is a novel technology designed for geophysical exploration and therefore has some limitations which we will explore. We started with the dataset from the PoroTomo project because of its unique experimental layout of colocated geophone array and DAS deployment so the two recording technologies can be compared side-by-side.

58 GEOSCIENCES↗

Daily grass reference evapotranspiration with Meteosat Second Generation shortwave radiation and reference ET products

Here we assess the accuracy of estimating daily grass reference evapotranspiration (PM-ET o ) using daily shortwave radiation (R s ) and reference evapotranspiration (ET REF ) products provided by the Meteosat Second Generation (MSG) geostationary satellite delivered by the Satellite Applications Facility on Land Surface Analysis (LSA-SAF) framework. The accuracy of using reanalysis ERA5 shortwave radiation data (R s ERA5 ) provided by the European Center for Medium-Range Weather Forecasts (ECMWF) is also evaluated. The assessments were performed using observed weather variables at 37 weather stations distributed across continental Portugal, where climate conditions range from semi-arid to humid, and 12 weather stations located in Azores islands, characterized by humid, windy and often cloudy conditions. This study&#x27;s use of data from a variety of climate conditions contributed to a unique and innovative assessment of the usability of LSA-SAF and ERA5 products for ET o estimation. The first assessment focused on comparing LSA-SAF estimates of R s (R s LSA-SAF ) against ground stations (R s ground ). The results showed a good matching between the two R s data sets for continental Portugal but a tendency for R s LSA-SAF to under-estimate R s ground in the cloudy islands of Azores. ET o values computed using R s LSA-SAF data and observed temperature, humidity and wind speed (ET o LSA-SAF ) were then compared with PM-ET o estimates with ground-based data, which were used as benchmark; input data of temperature and humidity needed for PM-ET o were quality checked for surface aridity effects. It was observed that ET o LSA-SAF is strongly correlated with PM-ET o (R 2 > 0.97) for most locations in continental Portugal, with regression coefficient of a linear regression forced to the origin ranging between 0.95 and 1.05, mean root mean square error (RMSE) of 0.13 mm d –1 , and Nash and Sutcliff efficiency of modeling (EF) above 0.95. For most Azores locations, ET o LSA-SAF over-estimated PM-ET o . This is likely a consequence of the high spatio-temporal heterogeneity of weather conditions that occur in these oceanic islands together with the different footprints of satellite (averaged over the pixel) and station observations. Reanalysis ERA5 shortwave radiation data presented similar behavior to the LSA-SAF products, however with slightly lower accuracy. The daily LSA-SAF ET REF product (ET REF LSA-SAF ) was assessed and results have shown a good accuracy of this product, with acceptable RMSE and high EF values, for continental Portugal but a low accuracy for the Azores islands. A simplified bias correction approach was shown to improve both ET o derived from the LSA-SAF products, namely for Azores stations, which seem to be representative of smaller areas. The use of the FAO-PM temperature approach (PMT) was also assessed using the R s LSA-SAF and R s ERA5 data, which showed a superiority of the LSA-SAF product for ET o estimations (ET o PMT LSA-SAF ). No significant differences (p < 0.05) were observed in terms of the median value of the RMSE when adopting ET o PMT and ET REF LSA-SAF . Differently, results showed that using the R s LSA-SAF in the PMT approach (ET o PMT LSA-SAF ) produces significantly better RMSE results than ET o PMT and ET REF LSA-SAF . Overall, the performed assessment allows concluding that the use of R s LSA-SAF, and to a lesser extent the use of the R s ERA5 , highly improves the accuracy of computation of ET o when R s observations are not available, including when only temperature data are accessible. The use of the ET REF LSA-SAF product is a good alternative when observed weather data are not available.

54 ENVIRONMENTAL SCIENCES↗

Effects of 9.5 Years of Whole-Soil Warming on the Fatty Acid and n-Alkanes Composition in Bulk Soil and Density Fractions at Blodgett Experimental Forest, California, USA

Original data of molecular data (fatty acids and n-alkanes) including concentrations and calculated molecular proxies in a whole-soil warming experiment at the Blodgett Forest Research Station after 9.5 years of warming. The study site has a Mediterranean climate with annual average temperature of 12.5 ℃ and annual average precipitation of 1774 mm. The study site is characterized by a mesic Ultic Alfisol formed from granitic parent material, corresponding to a Dystric Cambisol under the World Reference Base for Soil Resources (WRB) classification system. Experimental warming is applied throughout the soil profile to a depth of 1 m using vertically embedded heating cables that raise soil temperature by 4 °C relative to ambient conditions. Soil samples were collected on 1 May 2023, after the experiment had been operating continuously for about 9.5 years since its initiation in January 2014.The data has been processed from raw data and cross-validated by other peers. The dataset includes: - Bulk_Fattyacid_9.5-year_Soil_Warming_Blodgett, California, USA: fatty acid concentrations and proxies including Carbon Preference Index (CPI) and Average Chain Length (ACL) of bulk soil organic carbon; - Fractions_Fattyacid_9.5-year_Soil_Warming_Blodgett, California, USA: fatty acid concentrations and proxies including CPI and ACL of free particulate organic matter (fPOM) and mineral-associated organic matter (MAOM); - Bulk_Alkanes_9.5-year_Soil_Warming_Blodgett, California, USA: n-alkanes concentrations and proxies including CPI and ACL of bulk soil organic carbon; - Fractions_Alkanes_9.5-year_Soil_Warming_Blodgett, California, USA: n-alkanes concentrations and proxies including CPI and ACL of fPOM and MAOM; - n-Alkanes_All_Monomer_Concentration_9.5-year_Soil_Warming_Blodgett, California, USA: concentration of all the n-alkane monomers identified and integrated for bulk soil, fPOM and MAOM; - Fattyacid_All_Monomer_Concentration_9.5-year_Soil_Warming_Blodgett, California, USA: concentration of all the fatty acid monomers including diacids identified and integrated for bulk soil, fPOM, and MAOM. All data are provided in CSV format and can be viewed using Microsoft Excel. We specifically look at fatty acids (FA) and n-alkanes in bulk soil, fPOM and MAOM and calculated molecular proxies such as CPI and ACL to understand the source of oragnic carbon (with ACL) and degree of decomposition (CPI) of each soil fraction. Due to lack of long-chain fatty acids (carbon number ⩾ 20), microorganism-derived organic carbon is characterized by shorter ACL in comparison to plant-derived organic carbon. Fresh SOC is characterized by even-over-odd dominance for fatty acids and odd-over-even dominance for n-alkanes. Therefore, CPI indicates whether soil organic carbon (SOC) represents fresh input (CPI > 10) or is strongly decomposed (close to 1). The research questions should be then, after 9.5-year warming: 1. whether the relative contribution between microorganism-derived and plant-derived SOC in each soil fraction? 2. whether fPOM became more decomposed whereas MAOM remained relatively persistent in each soil fraction across the soil depth?

Carbon↗

Assessment of Mechanical Draft Cooling Tower Thermal Emissions from Visual Images of Plumes

Using a one-dimensional code, we computed the power (enthalpy discharge rate) of a twelve-cell mechanical draft cooling tower (MDCT) using over two hundred visible condensed water vapor plume volume measurements derived from images, weather data, and tower operating conditions. The plume images were simultaneously captured by multiple stationary digital cameras surrounding the cooling tower. An analysis technique combining structure from motion (SfM), a neural-network-based image segmentation algorithm, and space carving was used to quantify the volumes. Afterwards, the power output was computed using novel techniques in the one-dimensional code that included cooling tower exhaust plume adjacency effects implemented with a modified version of the entrainment function, weather data averaged from eleven stations, and fan operations at the times when plume volumes were measured. The model was then compared with the averaged observed power output, and it validated well with an average error ranging from 6 to 12%, depending on the meteorological data used in the simulations. This methodology can possibly determine power plant fuel consumption rates by applying visible imagery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observations of Mantle Seismic Anisotropy Using Array Techniques: Shear-Wave Splitting of Beamformed SmKS Phases

Shear-wave splitting measurements are commonly used to resolve seismic anisotropy in both the upper and lowermost mantle. Typically, such techniques are applied to SmKS phases that have reflected (m-1) times off the underside of the core-mantle boundary before being recorded. Practical constraints for shear-wave splitting studies include the limited number of suitable phases as well as the large fraction of available data discarded because of poor signal-to-noise ratios (SNRs) or large measurement uncertainties. Array techniques such as beamforming are commonly used in observational seismology to enhance SNRs, but have not been applied before to improve SmKS signal strength and coherency for shear wave splitting studies. Here, we investigate how a beamforming methodology, based on slowness and backazimuth vespagrams to determine the most coherent incoming wave direction, can improve shear-wave splitting measurement confidence intervals. Through the analysis of real and synthetic seismograms, we show that (a) the splitting measurements obtained from the beamformed seismograms (beams) reflect an average of the single-station splitting parameters that contribute to the beam; (b) the beams have (on average) more than twice as large SNRs than the single-station seismograms that contribute to the beam; (c) the increased SNRs allow the reliable measurement of shear wave splitting parameters from beams down to average single-station SNRs of 1.3. Beamforming may thus be helpful to more reliably measure splitting due to upper mantle anisotropy. Moreover, here we show that beamforming holds potential to greatly improve detection of lowermost mantle anisotropy by demonstrating differential SKS–SKKS splitting analysis using beamformed USArray data.

54 ENVIRONMENTAL SCIENCES↗

On the measurement of S diff splitting caused by lowermost mantle anisotropy

Seismic anisotropy has been detected at many depths of the Earth, including its upper layers, the lowermost mantle and the inner core. While upper mantle seismic anisotropy is relatively straightforward to resolve, lowermost mantle anisotropy has proven to be more complicated to measure. Due to their long, horizontal ray paths along the core–mantle boundary (CMB), S waves diffracted along the CMB (S diff ) are potentially strongly influenced by lowermost mantle anisotropy. S diff waves can be recorded over a large epicentral distance range and thus sample the lowermost mantle everywhere around the globe. S diff therefore represents a promising phase for studying lowermost mantle anisotropy; however, previous studies have pointed out some difficulties with the interpretation of differential SH diff –SV diff traveltimes in terms of seismic anisotropy. Here, we provide a new, comprehensive assessment of the usability of S diff waves to infer lowermost mantle anisotropy. Using both axisymmetric and fully 3-D global wavefield simulations, we show that there are cases in which S diff can reliably detect and characterize deep mantle anisotropy when measuring traditional splitting parameters (as opposed to differential traveltimes). First, we analyze isotropic effects on S diff polarizations, including the influence of realistic velocity structure (such as 3-D velocity heterogeneity and ultra-low velocity zones), the character of the lowermost mantle velocity gradient, mantle attenuation structure, and Earth’s Coriolis force. Secondly, we evaluate effects of seismic anisotropy in both the upper and the lowermost mantle on SH diff waves. In particular, we investigate how SH diff waves are split by seismic anisotropy in the upper mantle near the source and how this anisotropic signature propagates to the receiver for a variety of lowermost mantle models. We demonstrate that, in particular and predictable cases, anisotropy leads to S diff splitting that can be clearly distinguished from other waveform effects. Here, these results enable us to lay out a strategy for the analysis of S diff splitting due to anisotropy at the base of the mantle, which includes steps to help avoid potential pitfalls, with attention paid to the initial polarization of S diff and the influence of source-side anisotropy. We demonstrate our S diff splitting method using three earthquakes that occurred beneath the Celebes Sea, measured at many transportable array stations at a suitable epicentral distance. We resolve consistent and well-constrained S diff splitting parameters due to lowermost mantle anisotropy beneath the northeastern Pacific Ocean.

54 ENVIRONMENTAL SCIENCES↗

Data Analysis of the 2020 Central Idaho Mainshock-Aftershock Sequence

In an effort to inform the Senior Seismic Hazard Analysis Committee for the Idaho National Laboratory, we provide an improved aftershock catalog related to the March 31, 2020, Mw6.5 Stanley, Idaho earthquake from picks related to a temporary network of two real-time and 15 non-telemetered seismometers within the epicentral area. From the permanent and temporary (XP) real-time network, the USGS cataloged 1,946 aftershocks between April 1, 2020 and October 31, 2020. To improve aftershock location and magnitudes, we manually picked arrival times of P and S waves from off-line stations in the XP temporary network, generated a new crustal velocity model, and independently relocated each event using the HypoDD double-difference earthquake algorithm. We created our new velocity model from existing broadband and active source seismic campaign data that were acquired near the epicentral region prior to the 2020 earthquake. We compare arrival time differences, epicentral locations and depths between aftershocks recorded with the two catalogs. We find the addition of local stations provides tighter aftershock clustering that suggests an improved aftershock locations. To detect lower magnitude events, we employed deep learning. Our method solves common problems associated with detecting many events that have a low signal-to-noise ratio. From the machine learning database, we detected more than 74,000 aftershocks. Based on the number of identified earthquakes and Gutenberg-Richter relationships derived from the USGS catalog, we estimate that we have reduced the completion magnitude for the Stanley earthquake sequence to below M1 using this machine learning approach. We located each aftershock with our new velocity model. Our new velocity model and picks suggests aftershocks occurred mostly at shallower depths than assessed in the USGS catalog. These aftershocks align along two linear trends that suggest the activation of two unnamed primary faults.

58 GEOSCIENCES↗

Electrochemical Acid Sequestration to Ease Ocean Acidification (EASE-OA) - CRADA 600 (Abstract)

The PNNL team will coordinate logistics involved with setting up the field trial on the PNNL Sequim campus in collaboration with Ebb Carbon. Facilities on the PNNL Sequim campus are capable of pumping raw or filtered seawater from Sequim Bay at a rate ~45,000 L hr -1 , which can accommodate the 4000 L hr -1 requirement of the 200 ton CO2 yr-1 Ebb Carbon marine carbon dioxide removal (mCDR) system. The primary tasks for the PNNL team are 1) laying out appropriate indoor and outdoor spaces for installing the Ebb Carbon’s mCDR system, 2) facilitating Ebb Carbon’s access to the PNNL’s seawater intake on the PNNL Sequim campus, 3) conducting mesocosm experiments within the PNNL Sequim campus laboratories to test how the brine and base discharged from the Ebb Carbon system affect marine life, and 4) facilitating Ebb Carbon access to the PNNL Sequim installation site and aiding in maintenance as needed. In addition to these tasks, the PNNL team will provide surface water quality data (e.g., salinity, temperature, pH, dissolved O2) from a monitoring station located on the pier to contextualize starting conditions of the seawater used in the mCDR process. Finally, the PNNL team will also consult with Ebb Carbon on strategies for improving overall system performance and next steps for further scaling and/or monitoring the effectiveness of the mCDR system.

54 ENVIRONMENTAL SCIENCES↗

The AMACStar ASIC for the HL-LHC ATLAS ITk Strip detector: design, verification, testing, and quality assurance

For the high-luminosity upgrade to the LHC (HL-LHC), the ATLAS detector at CERN requires an all-new inner detector, the Inner Tracker (ITk). The ITk Strip subdetector is made up of silicon modules, which include three types of radiation-hard ASICs. One of these is the Autonomous Monitor and Control (AMAC). The AMAC is manufactured by Global Foundries using 130 nm CMOS8RF DM technology and is approximately 3 by 5 mm in size. This ASIC autonomously monitors the temperatures, voltages, and currents in the module components while controlling critical values in order to prevent these quantities from reaching dangerous levels. The final design, AMACStar, was verified, tested, and ensured to perform all necessary functions. A quality control procedure using an in-house probe station set-up was developed in order to ensure that every individual chip on each wafer of AMACStars required by the ITk Strip project met performance requirements. The average per wafer yield of usable AMACStars is 92.33%, exceeding the design-specific 90% yield estimated for project costing. This estimate was based on actual yields for similar designs in this process.

Analogue electronic circuits↗

IAEA ITC28 Project Report. 28th International Training Course on the Physical Protection of Nuclear Materials and Nuclear Facilities

Sandia National Laboratories (SNL) has hosted the International Training Course on the Physical Protection of Nuclear Materials and Nuclear Facilities since 1978. This course is the flagship training course of the International Atomic Energy Agency (IAEA). On behalf of the National Nuclear Security Administration (NNSA), SNL manages, develops, and coordinates all course materials, and works closely with the IAEA to arrange all logistical details for the course. ITC-28 incorporated several new approaches based on feedback and experience with ITC-27 and earlier versions of the course. For ITC-28, an addition to the Integrated Security Facility (ISF) at SNL was a mock reactor hall with a mock reactor pool. Other facilities at the ISF include a mock processing facility, material receiving area, and central alarm station. The physical protection system at the ISF—an area that formerly housed Category I nuclear material—provides many opportunities for hands-on, real world training in the design and evaluation of a physical protection system (PPS). This document provides a brief description of ITC-28, including a summary of lessons learned and key recommendations for future development efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits

There are concerns about the effects of High-Altitude Electromagnetic Pulses (HEMP) on the electric power grid. Activities to date tested and analyzed vulnerability of digital protective relays (DPRs) used in power substations, but the effect of HEMP on the greater substation environment is not well known. This work establishes a method of testing the vulnerability of circuit breaker control and protective relay circuits to the radiated E1 pulse associated with HEMP based on coupling to the cables in a substation yard. Two DPRs from Schweitzer Engineering Laboratories, Inc. were independently tested. The test setup also included a typical cable in a substation yard with return plane to emulate the ground grid and other ground conductors near the yard cable, cabinetry housing the installed DPRs, station battery and battery charger, terminal block elements, and a breaker simulator to emulate a substation yard configuration. The DPRs were powered from the station battery and the transformer inputs energized with a three-phase source to maintain typical operating conditions during the tests. Vulnerability testing consisted of a conducted E1 pulse injected into the center of the yard cable of the DPR circuits. Current measurements on the yard cable and DPR inputs indicated significant attenuation of the conducted pulse arriving at the control house equipment from the emulated substation yard. This reduction was quantified with respect to the equivalent open-circuit voltage on the yard cable. No equipment damage or undesired operation occurred on the tested circuits for values below 180 kV, which is significantly higher than the anticipated coupling to a substation yard cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗