Atomic layer deposition of 2D and 3D standards for synchrotron-based quantitative composition and structure analysis methods

Atomic layer deposition (ALD) is a scalable deposition technique known for producing uniform, conformal films of a wide range of compounds on nearly any substrate material. These traits make it an ideal deposition method for producing films to replace the National Institute of Standards and Technology (NIST) standards and create Standard Reference Materials (SRMs) on a wide range of relevant two-dimensional and three-dimensional substrates. The use of SRM from NIST for quantitative analysis of chemical composition using synchrotron based x-ray fluorescence (SR-XRF) and scanning transmission x-ray microscopy (STXM) is common. Such standards, however, can suffer from inhomogeneity in chemical composition and thickness and often require further calculations, based on sample mounting and detector geometry, to obtain quantitative results. These inhomogeneities negatively impact the reproducibility of the measurements and the quantitative measure itself. Utilizing Rutherford backscattering, x-ray reflectivity, quartz crystal microbalance, STXM, and SR-XRF, the authors show that ALD is capable of producing high quality standards that are homogenous over scales ranging from nanometers to 100s of micrometers.

Becker, Nicholas G.↗

Characterizing particle-based thermal storage performance using optical methods for use in next generation concentrating solar power plants

Concentrating Solar Power (CSP) generation is an attractive option for low-emission power generation; however, the high costs of thermal storage associated with concentrating solar create a large barrier for their use and adaptation into modern life. Lowering their operation costs, while maintaining high thermal storage and transfer performance is essential. Solid particle-based heat exchange systems can reduce CSP cost but are often less efficient. Efforts to increase their performance have led to use of binary size particle mixes. Presented is an optical-based thermal analysis technique used to measure near-wall thermal conductivity of particle beds essential in determining their heat exchanger efficiency. Modulated Photothermal Radiometry is used to make dynamic temperature measurements, allowing for the extraction of the most relevant thermal properties like thermal conductivity, specific heat, and effusivity. The system uses a modulated laser source causing a damped periodic heat flux, resulting in a frequency and thermal property dependent surface temperature, of which is measured using radiometry. Lock-In techniques are used to extrapolate the amplitude of the signal. Plotting the amplitude against the root angular frequency allows for effusivity measurement by ratio to a known sample. Using specific heat measurements from literature and density measurements, the thermal conductivity of the particle mixes can be calculated. The simplicity of MPTR to probe through the depth of the bed is ideal for use in CSP for dynamic thermal performance monitoring.

Corona, Javier↗

Pulmonary lobe segmentation based on ridge surface sampling and shape model fitting

Purpose: Performing lobe-based quantitative analysis of the lung in computed tomography (CT) scans can assist in efforts to better characterize complex diseases such as chronic obstructive pulmonary disease (COPD). While airways and vessels can help to indicate the location of lobe boundaries, segmentations of these structures are not always available, so methods to define the lobes in the absence of these structures are desirable. Methods: The authors present a fully automatic lung lobe segmentation algorithm that is effective in volumetric inspiratory and expiratory computed tomography (CT) datasets. The authors rely on ridge surface image features indicating fissure locations and a novel approach to modeling shape variation in the surfaces defining the lobe boundaries. The authors employ a particle system that efficiently samples ridge surfaces in the image domain and provides a set of candidate fissure locations based on the Hessian matrix. Following this, lobe boundary shape models generated from principal component analysis (PCA) are fit to the particles data to discriminate between fissure and nonfissure candidates. The resulting set of particle points are used to fit thin plate spline (TPS) interpolating surfaces to form the final boundaries between the lung lobes. Results: The authors tested algorithm performance on 50 inspiratory and 50 expiratory CT scans taken from the COPDGene study. Results indicate that the authors' algorithm performs comparably to pulmonologist-generated lung lobe segmentations and can produce good results in cases with accessory fissures, incomplete fissures, advanced emphysema, and low dose acquisition protocols. Dice scores indicate that only 29 out of 500 (5.85%) lobes showed Dice scores lower than 0.9. Two different approaches for evaluating lobe boundary surface discrepancies were applied and indicate that algorithm boundary identification is most accurate in the vicinity of fissures detectable on CT. Conclusions: The proposed algorithm is effective for lung lobe segmentation in absence of auxiliary structures such as vessels and airways. The most challenging cases are those with mostly incomplete, absent, or near-absent fissures and in cases with poorly revealed fissures due to high image noise. However, the authors observe good performance even in the majority of these cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prior-based artifact correction (PBAC) in computed tomography

Purpose: Image quality in computed tomography (CT) often suffers from artifacts which may reduce the diagnostic value of the image. In many cases, these artifacts result from missing or corrupt regions in the projection data, e.g., in the case of metal, truncation, and limited angle artifacts. The authors propose a generalized correction method for different kinds of artifacts resulting from missing or corrupt data by making use of available prior knowledge to perform data completion. Methods: The proposed prior-based artifact correction (PBAC) method requires prior knowledge in form of a planning CT of the same patient or in form of a CT scan of a different patient showing the same body region. In both cases, the prior image is registered to the patient image using a deformable transformation. The registered prior is forward projected and data completion of the patient projections is performed using smooth sinogram inpainting. The obtained projection data are used to reconstruct the corrected image. Results: The authors investigate metal and truncation artifacts in patient data sets acquired with a clinical CT and limited angle artifacts in an anthropomorphic head phantom data set acquired with a gantry-based flat detector CT device. In all cases, the corrected images obtained by PBAC are nearly artifact-free. Compared to conventional correction methods, PBAC achieves better artifact suppression while preserving the patient-specific anatomy at the same time. Further, the authors show that prominent anatomical details in the prior image seem to have only minor impact on the correction result. Conclusions: The results show that PBAC has the potential to effectively correct for metal, truncation, and limited angle artifacts if adequate prior data are available. Since the proposed method makes use of a generalized algorithm, PBAC may also be applicable to other artifacts resulting from missing or corrupt data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for{sup 103}Pd and highest for {sup 131}Cs, except for the tumor where the average dose is highest for {sup 103}Pd and lowest for {sup 131}Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-519: Is Geometry Based Setup Sufficient for All of the Head and Neck Treatment Cases?: A Feasibility Study Towards the Dose Based Setup

Purpose: This study compares the geometric-based setup (GBS) which is currently used in the clinic to a novel concept of dose-based setup (DBS) of head and neck (H&N) patients using cone beam CT (CBCT) of the day; and evaluates the clinical advantages. Methods: Ten H&N patients who underwent re-simulation and re-plan due to noticeable anatomic changes during the course of the treatments were retrospectively reviewed on dosimetric changes in the assumption of no plan modification was performed. RayStation planning system (RaySearch Laboratories AB, Sweden) was used to match (ROI fusion module) between prescribed isodoseline (IDL) in the CBCT imported along with ROIs from re-planned CT and the IDL of original plan (Dose-based setup: DBS). Then, the CBCT plan based on daily setup using the GBS (previously used for a patient) and the DBS CBCT plan recalculated in RayStation compared against the original CT-sim plan. Results: Most of patients’ tumor coverage and OAR doses got generally worsen when the CBCT plans were compared with original CT-sim plan with GBS. However, when DBS intervened, the OAR dose and tumor coverage was better than the GBS. For example, one of patients’ daily average doses of right parotid and oral cavity increased to 26% and 36%, respectively from the original plan to the GBS planning. However, it only increased by 13% and 24%, respectively with DBS. GTV D95 coverage also decreased by 16% with GBS, but only 2% decreased with DBS. Conclusion: DBS method is superior to GBS to prevent any abrupt dose changes to OARs as well as PTV/CTV or GTV at least for some H&N cases. Since it is not known when the DBS is beneficial to the GBS, a system which enables the on-line DBS may be helpful for better treatment of H&N.

60 APPLIED LIFE SCIENCES↗

WE-H-207A-07: Image-Based Versus Atlas-Based Internal Dosimetry

Purpose: Monte Carlo (MC) simulation is known as the gold standard method for internal dosimetry. It requires radionuclide distribution from PET or SPECT and body structure from CT for accurate dose calculation. The manual or semi-automatic segmentation of organs from CT images is a major obstacle. The aim of this study is to compare the dosimetry results based on patient’s own CT and a digital humanoid phantom as an atlas with pre-specified organs. Methods: SPECT-CT images of a 50 year old woman who underwent bone pain palliation with Samarium-153 EDTMP for osseous metastases from breast cancer were used. The anatomical date and attenuation map were extracted from SPECT/CT and three XCAT digital phantoms with different BMIs (i.e. matched (38.8) and unmatched (35.5 and 36.7) with patient’s BMI that was 38.3). Segmentation of patient’s organs in CT image was performed using itk-SNAP software. GATE MC Simulator was used for dose calculation. Specific absorbed fractions (SAFs) and S-values were calculated for the segmented organs. Results: The differences between SAFs and S-values are high using different anatomical data and range from −13% to 39% for SAF values and −109% to 79% for S-values in different organs. In the spine, the clinically important target organ for Samarium Therapy, the differences in the S-values and SAF values are higher between XCAT phantom and CT when the phantom with identical BMI is employed (53.8% relative difference in S-value and 26.8% difference in SAF). However, the whole body dose values were the same between the calculations based on the CT and XCAT with different BMIs. Conclusion: The results indicated that atlas-based dosimetry using XCAT phantom even with matched BMI for patient leads to considerable errors as compared to image-based dosimetry that uses the patient’s own CT Patient-specific dosimetry using CT image is essential for accurate results.

60 APPLIED LIFE SCIENCES↗

Outstanding radiation resistance of tungsten-based high-entropy alloys

A body-centered cubic W-based refractory high entropy alloy with outstanding radiation resistance has been developed. The alloy was grown as thin films showing a bimodal grain size distribution in the nanocrystalline and ultrafine regimes and a unique 4-nm lamella-like structure revealed by atom probe tomography (APT). Transmission electron microscopy (TEM) and x-ray diffraction show certain black spots appearing after thermal annealing at elevated temperatures. TEM and APT analysis correlated the black spots with second-phase particles rich in Cr and V. No sign of irradiation-created dislocation loops, even after 8 dpa, was observed. Furthermore, nanomechanical testing shows a large hardness of 14 GPa in the as-deposited samples, with near negligible irradiation hardening. Theoretical modeling combining ab initio and Monte Carlo techniques predicts the formation of Cr- and V-rich second-phase particles and points at equal mobilities of point defects as the origin of the exceptional radiation tolerance.

36 MATERIALS SCIENCE↗

Optimization-Based Approach for Joint X-Ray Fluorescence and Transmission Tomographic Inversion

Fluorescence tomographic reconstruction, based on the detection of photons coming from fluorescent emission, can be used for revealing the internal elemental composition of a sample. On the other hand, conventional X-ray transmission tomography can be used for reconstructing the spatial distribution of the absorption coefficient inside a sample. In this work, we integrate both X-ray fluorescence and X-ray transmission data modalities and formulate a nonlinear optimization-based approach for reconstruction of the elemental composition of a given object. This model provides a simultaneous reconstruction of both the quantitative spatial distribution of all elements and the absorption effect in the sample. Mathematically speaking, we show that compared with the single-modality inversion (i.e., the X-ray transmission or fluorescence alone), the joint inversion provides a better-posed problem, which implies a better recovery. Therefore, the challenges in X-ray fluorescence tomography arising mainly from the effects of self-absorption in the sample are partially mitigated. The use of this technique is demonstrated on the reconstruction of several synthetic samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Audience Based View of Publication Impact

With increasing pressure to demonstrate a return on investment, scienti c user facilities and government funded research projects must strive to demonstrate positive impact of their research on oth- ers. Historically, citation counts and journal impact factor have been widely used as a single quantitative measure of impact. However, with the expansion of various modes of communication, citation counts no longer hold as much merit as a single measure of impact. This work seeks to expand on citation counts by considering the audience to which a publication draws attention. Based on commu- nication mode, there are various audiences that may be "impacted" but those audiences are not fully captured by citation count. Conse- quently, we propose that impact measures for publications should be oriented around the audience with quanti able measures based on the various communication modes.

Patton, Robert↗

Attention-based Aspect Reasoning for Knowledge Base Question Answering on Clinical Notes

Question Answering (QA) in clinical notes has gained a lot of attention in the past few years. Existing machine reading comprehension approaches in clinical domain can only handle questions about a single block of clinical texts and fail to retrieve information about different patients and clinical notes. To handle more complex questions, we aim at creating knowledge base from clinical notes to link different patients and clinical notes, and performing knowledge base question answering (KBQA). Based on the expert annotations in n2c2, we first created the ClinicalKBQA dataset that includes 8,952 QA pairs and covers questions about seven medical topics through 322 question templates. Then, we proposed an attention-based aspect reasoning (AAR) method for KBQA and investigated the impact of different aspects of answers (e.g., entity, type, path, and context) for prediction. The AAR method achieves better performance due to the well-designed encoder and attention mechanism. In the experiments, we find that both aspects, type and path, enable the model to identify answers satisfying the general conditions and produce lower precision and higher recall. On the other hand, the aspects, entity and context, limit the answers by node-specific information and lead to higher precision and lower recall.

Wang, Ping↗

Automating Embedded Analysis Capabilities and Managing Software Complexity in Multiphysics Simulation, Part I: Template-Based Generic Programming

An approach for incorporating embedded simulation and analysis capabilities in complex simulation codes through template-based generic programming is presented. This approach relies on templating and operator overloading within the C++ language to transform a given calculation into one that can compute a variety of additional quantities that are necessary for many state-of-the-art simulation and analysis algorithms. An approach for incorporating these ideas into complex simulation codes through general graph-based assembly is also presented. These ideas have been implemented within a set of packages in the Trilinos framework and are demonstrated on a simple problem from chemical engineering.

Pawlowski, Roger P.↗

AmeriFlux BASE Flux/Met Data QA/QC and Processing (AMF-BASE-QAQC) v1.0.0

The AmeriFlux BASE Flux/Met Data QA/QC and Processing (AMF-BASE-QAQC) code provides tools to review and prepare continuous flux/met data submitted to the AmeriFlux Management Project for publication as the AmeriFlux BASE data product. The code provides 3 core functionalities: Format QA/QC assesses submitted data files for compliance with the required submission format; Data QA/QC assesses the data quality; BASE Publish prepares the data for publication.

Christianson, Danielle↗

Science-Based Acceleration of the Full Value Stream for Metal Additive Manufacturing: Expedited Powder Development and Additive Manufacturing Deployment in the Areas of Ni-Base Superalloy and Custom Alloy Powders for AM (Final Report)

The overall Science-based Acceleration of the Full Value Stream for Metal Additive Manufacturing (AM): Expedited Powder Development and Additive Manufacturing Deployment (“X-P4AM”) project objective is to drastically reduce the time-to-market barriers for new additive alloys of interest in automotive and aerospace applications, through computational alloy design with rapid screening and down- selection via synthesis of candidate alloys with rapid solidification. The project will also refine the technology in high pressure gas atomization to improve the production of commercial quantities of selected powders with high powder yields and enhanced powder quality. Production of modified nickel-based superalloys and a Ni-containing alloy based on a high entropy composition, enhanced powder production methods, and optimized AM build parameterization provided critical steps in widespread adoption of AM technology for aerospace applications, in this case. The individual backgrounds and capabilities of the Parties are ideally suited to the successful execution of this work. The included work enhanced the Contractors’ AM capabilities, a core competency of the Contractors, and develop a close working relationship with the Participant in the area of nickel-based powder superalloys and custom alloys and their end use.

36 MATERIALS SCIENCE↗

Science-Based Acceleration of the Full Value Stream for Metal Additive Manufacturing: Expedited Powder Development and Additive Manufacturing Deployment in the Areas of Ni-Base Superalloy and Custom Alloy Powders for AM

The overall Science-based Acceleration of the Full Value Stream for Metal Additive Manufacturing (AM): Expedited Powder Development and Additive Manufacturing Deployment (“X-P4AM”) project objective is to drastically reduce the time-to-market barriers for new additive alloys of interest in automotive and aerospace applications, through computational alloy design with rapid screening and down- selection via synthesis of candidate alloys with rapid solidification. The project will also refine the technology in high pressure gas atomization to improve the production of commercial quantities of selected powders with high powder yields and enhanced powder quality. Production of modified nickel-based superalloys and a Ni-containing alloy based on a high entropy composition, enhanced powder production methods, and optimized AM build parameterization provided critical steps in widespread adoption of AM technology for aerospace applications, in this case. The individual backgrounds and capabilities of the Parties are ideally suited to the successful execution of this work. The included work enhanced the Contractors’ AM capabilities, a core competency of the Contractors, and develop a close working relationship with the Participant in the areas of nickel-based powder superalloys and custom alloys and their end use.

36 MATERIALS SCIENCE↗

Science-Based Acceleration of the Full Value Stream for Metal Additive Manufacturing: Expedited Powder Development and Additive Manufacturing Deployment in the Areas of Ni-Base Superalloy and Custom Alloy Powders for AM

The overall Science-based Acceleration of the Full Value Stream for Metal Additive Manufacturing (AM): Expedited Powder Development and Additive Manufacturing Deployment (“X-P4AM”) project objective is to drastically reduce the time-to-market barriers for new additive alloys of interest in automotive and aerospace applications, through computational alloy design with rapid screening and down- selection via synthesis of candidate alloys with rapid solidification. The project will also refine the technology in high pressure gas atomization to improve the production of commercial quantities of selected powders with high powder yields and enhanced powder quality. Production of modified nickel-based superalloys and a Ni-containing alloy based on a high entropy composition, enhanced powder production methods, and optimized AM build parameterization provided critical steps in widespread adoption of AM technology for aerospace applications, in this case. The individual backgrounds and capabilities of the Parties are ideally suited to the successful execution of this work. The included work enhanced the Contractors’ AM capabilities, a core competency of the Contractors, and develop a close working relationship with the Participant in the areas of nickel-based powder superalloys and custom alloys and their end use.

36 MATERIALS SCIENCE↗