Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM DYNAMICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

CEBAF Injector for K Long Beam Conditions

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab concurrently operates four experimental Halls with distinct bunch charge specifications and repetition rates. Numerous critical beam parameters within CEBAF are configured in the injector, some remaining unchanged throughout the accelerator. Consequently, the injector plays a crucial role in determining final beam characteristics, including bunch structure, beam sizes, bunch lengths, energy spread, and beam transmission. The Jefferson Lab KL experiment is scheduled to take place at CEBAF in Hall D, featuring a much lower bunch repetition rate of 7.80 MHz or 15.59 MHz, below the nominal values of 249.5 MHz or 499 MHz. Although the proposed average current of 5 ?A or 10 ?A is low compared to the maximum CEBAF cur- rent of approximately 180 ?A, the corresponding bunch charge is unusually high for CEBAF injector operation. This study focuses on the behavior of low-repetition-rate, high-bunch- charge (0.32 to 0.64 pC) beams in the CEBAF injector. We investigated the evolution and transmission of low-charge beams to space-charge dominated high-charge beams in the front end of the CEBAF injector for two configurations: the pre-existing CEBAF Phase 1 injector upgrade, operated at 130 kV, and the existing CEBAF Phase 2 injector upgrade, operated at 140 kV, 180 kV, and to be operated at 200 kV. The electron beam through the CEBAF injector is characterized using beam dynamics simulations and comparisons with the available measurements performed at 130 kV. Multi-objective genetic optimizations of the CEBAF injector were performed to determine the operating magnetic elements and RF settings for the evolution and transmission of low, moderate, and high charge beams in the CEBAF injector at 180 kV and 200 kV DC gun voltages. Subsequently, simulations at the same voltages were conducted to obtain the beam characteristics at the front end of the CEBAF injector. The laser spot size and laser pulse length at the cathode were varied to observe their effects on beam transmission in the injector at different voltages (130 kV, 180 kV, and 200 kV). Experimental studies at 130 kV, 140 kV, and 180 kV validate the simulations. Beam study measurements are carried out using EPICS tools, while optimizations and simulations are facilitated by General Particle Tracer. Based on the findings, optimal parameters for the upcoming Jefferson Lab KL experiment are proposed, utilizing a lower repetition rate and higher bunch charge

Pokharel, Sunil↗

RF transient analysis and stabilization of the phase and energy of the proposed PIP-II LINAC

Here, this paper describes a recent effort to develop and benchmark a simulation tool for the analysis of RF transients and their compensation in an H- linear accelerator. Existing tools in this area either focus on electron LINACs or lack fundamental details about the LLRF system that are necessary to provide realistic performance estimates. In our paper we begin with a discussion of our computational models followed by benchmarking with existing beam-dynamics codes and measured data. We then analyze the effect of RF transients and their compensation in the PIP-II LINAC, followed by an analysis of calibration errors and how a Newton’s Method based feedback scheme can be used to regulate the beam energy to within the specified limits.

43 PARTICLE ACCELERATORS↗

HOM mitigation for FCC-ee

In this work, high electron and positron currents (1.5 A) are planned to be used in the Future Circular electron-positron Collider (FCC-ee) with a goal to archive high luminosity of order of 2.3 10 36 cm -2 s -2 at the Z-production collision at the beam energy of 45.6 GeV. Coherent effects at the high-current machine impose certain limitations on the magnitude of the impedance of the machine. The potential well distortion due to inductive part of the impedance may give a large bunch lengthening. The microwave longitudinal and transverse instability set the total limit on the effective impedance. The multi bunch longitudinal and transverse mode-coupling can be more dangerous for the beam dynamics, but fortunately the feedback system can be used to damp these instabilities. An additional effect of the resonance part of the impedance is the HOM (Higher Order Modes) heating. It can happen not only in the RF cavities, but anywhere in the machine beam pipe where trapped mode or traveling waves absorb their power. Temperature raise due to HOM heating can be very high in the closed volumes without cooling. Very important the HOM heating is in the Interaction Region (IR), because it brings an additional background. The local heating in the IR can reach tens of kW of power. Some part of the electromagnetic waves, excited by the beam, with a frequency above the cutoff frequency will travel away from the IR and go down the beam pipe. The absorption of these waves can bring heating problems to other parts of the accelerator. A large energy loss of the beams in the interaction region can be a severe problem. The temperature of the IR chamber will go up and the vacuum will be spoiled. If the IR chamber has small gaps or hidden cavities (like in shielded bellows or valves), then electric sparks or arcing may cause additional vacuum spikes. Heating of nonevaporable getters (if they are will be used in the IR) may bring vacuum instability (the temperature can go above the recovery level). Lastly, all of these things can make the backgrounds much higher. One can find a description of these effects in publications. Impedance study for FCC-ee can be found in reference.

42 ENGINEERING↗

Optical emission spectroscopy and imaging of low-pressure N2 plasmas generated by intense fast-pulsed electron beams

An optical emission spectroscopic (OES) and imaging characterization is conducted on N2 plasmas generated by a 100 keV fast-pulsed electron beam. The electron beams are injected into an N2 gas filled volume with a current of 4.5 kA (300 A/cm2) and a 100 ns pulse width. The characterization is conducted at the pressures, 1 Torr and 0.1 Torr, corresponding to two distinct regimes that exhibit significantly different plasma dynamics. Beam impact ionization is shown to be a primary mechanism for producing low temperature plasmas at 1 Torr during beam output. After beam termination, ionization by an inductive electric field becomes the primary mechanism for plasma formation later in time for both pressures. OES and plasma imaging are used in this work as a diagnostic tool to track the distribution of electronic, vibrational, and rotational state transitions and ionized species. This is achieved with the use of a multi-resolution suite of spectrometers capable of acquiring time-resolved spectra. Vibrational and rotational bands of the N2 second positive system (C3Πu→B3Πg) and the N2+ first negative system (B2Σu+→X2Σg+) are identified in both regimes as well as N+ states exclusively in the lower pressure regime. Vibrational and rotational spectra are shown to track the evolution of the time-varying plasma current. Plasma imaging also reveals spatially nonuniform plasma emission at 0.1 Torr. A few hundred shots are recorded to fully characterize the emissions, and results are shown to be highly reproducible (≤±1% with 2σ confidence).

Kaiser, E. R. (ORCID:0000000336493938)↗

Numerical Analysis of High-Order Modes in SRF Resonators for Particle Accelerators

Over the past decades, superconducting technology has rapidly evolved towards high accelerating gradients and low surface resistance, making it possible to operate particle accelerators with high average beam currents and large duty factors. However, RF losses due to coherent excitation of the HOM become the limiting factor for these regimes. Unlike the cavity operating mode, which is tuned separately, the HOM parameters can significantly vary from one cavity to another due to finite mechanical tolerances during the manufacturing process. Thus, it is of utmost importance to know the HOM parameter spread in advance in order to predict unexpected cryogenic losses, overheating of beam line components and maintain stable beam dynamics. In this paper, we present a method for generating cavity geometry with an arbitrary spread of mechanical imperfections and numerically evaluating HOM statistics. Knowing the spread of HOM parameters, we calculated the probability of resonant HOM losses in SRF accelerating cavities used in CW beam current machines such as the PIP-II and LCLS-II linacs, as well as for the SRF crab-cavity for the ILC project. Finally, we present experimental results of HOM spectra measurements in hundreds of 1.3 GHz cavities installed in LCLS-II cryomodules. Studying the effects of HOM excitation results in specifications of the SRF cavity and cryomodule and can significantly impact the efficiency and reliability of the machine operation.

Lunin, Andrei [Fermilab] (ORCID:0000000290096792)↗

Extreme radiation emission regime for electron beams in strong focusing ion channels and undulators

A fundamental comparison between a magnetic undulator and an ion channel, or betatron, radiation from relativistic electrons is presented. While conventional theories nominally range from the undulator (𝐾 <1) to the wiggler (𝐾 >1) regime, they are only applicable for sufficiently large Lorentz factors (𝛾 0 ≫𝐾). They therefore do not account for high 𝐾/𝛾 0 cases, for which we show that particle trajectories and radiation characteristics strongly deviate from the linear predictions in both magnetic undulators and ion channels. This problem arises from the fundamental differences between a magnetostatically and electrostatically induced oscillation. A reformulation of both the ion channel betatron wavelength and amplitude, as well as the same parameters in a magnetic undulator, permits us to compare cases with equivalent oscillation period and amplitude in the two different scenarios. The notable differences in spectral features of the two radiation mechanisms can then be addressed via numerical simulations of single particle as well as full beam dynamics. Additionally, we identify and quantify a novel transverse orbit precession effect in ion channels for particles with initial angular momentum relative to the device axis. This effect, which is significant in cases of strong transverse kinetic energy oscillations, alters both the radiation divergence and the beam emittance. In this paper, we present this new theoretical framework and compare its results with numerical simulation applied to realizable experimental tests of such radiation sources.

Frazzitta, Andrea [University of Rome “La Sapienza↗

A New 2.5 MeV Injector and Beam Test Facility for the Spallation Neutron Source

The U.S. Spallation Neutron Source (SNS) now operates with 1.2 MW of beam power on target with the near-term goal of delivering 1.4 MW and a longer-term goal of delivering >2 MW to support a planned second target station. Presently, H- beam pulses (50-60 mA, 1 ms, 60 Hz) from an RF-driven, Cs-enhanced, multi-cusp ion source are first accelerated to 2.5 MeV by a Radio Frequency Quadrupole (RFQ) accelerator, injected into a ~1 GeV linac, compressed to <1μs in an accumulator ring and ultimately delivered to a liquid mercury target for pulsed neutron production. In recent years concerns about the RFQ performance has motivated the procurement of a new RFQ and the creation of a Beam Test Facility (BTF) to allow off-line testing. The purpose of the BTF is to first validate performance of the new RFQ before installing it in place of the existing RFQ and later to serve as a stand-alone 2.5 MeV research accelerator employing the original SNS RFQ. After validating the new RFQ with respect to energy, emittance and transmission, the initial applications of the BTF will be to conduct 6D beam dynamic studies, develop & demonstrate ion sources capable of meeting the current and future requirements of the SNS, and contribute to neutron moderator development. This report provides a facility update, description of the BTF ion source systems as well as a discussion of the first LEBT and RFQ beam current measurements performed at the BTF.REFERENCES

Welton, Robert F.↗

Demonstration of a 1-D Submillimeter-Wave Phased Array with MEMS Phase Shifters

At submillimeter-wave frequencies, due to the nonavailability of low-loss phase shifters, electronic antenna beam scanning is difficult to realize. Traditionally, power-hungry and bulky motors are used to mechanically scan the antenna beam. At lower-frequencies, phased array antennas are most commonly used where low-loss phase shifters are used with the array elements to accomplish beam steering. However, development of similar phased array antennas at submillimeter-waves has been challenging. Recently, we have developed a low-loss microelectromechanical systems (MEMS) based phased shifter in the 500-750 GHz band. In this work, we present a submillimeter-wave phased array antenna system with a cavity-backed double slot antenna architecture using the MEMS-based phase shifters. To demonstrate the concept, we developed two arrays: first one is a 8×1 linear antenna array with a fixed waveguide feeding network that achieved ±20◦ beam scanning, 18 dB directivity, and less than 1 dB scan loss over the design frequency of 500–570 GHz. The second one is a 4 × 1 linear antenna array with integrated MEMS-based phase shifters on each array element, achieving 15 dB directivity and capable of dynamic beam scanning over a range of ±9 ◦ . All the plots presented are simulated results since the parts are currently being fabricated. We hope to have access to our assembly and measurement facilities over the next few months and present measured performances at the conference.

Chattopadhyay, G.↗

Rotation of X-ray polarization in the glitches of a silicon crystal monochromator

EXAFS studies on dilute samples are usually carried out by collecting the fluorescence yield using a large-area multi-element detector. This method is susceptible to the `glitches' produced by all single-crystal monochromators. Glitches are sharp dips or spikes in the diffracted intensity at specific crystal orientations. If incorrectly compensated, they degrade the spectroscopic data. Normalization of the fluorescence signal by the incident flux alone is sometimes insufficient to compensate for the glitches. Measurements performed at the state-of-the-art wiggler beamline I20-scanning at Diamond Light Source have shown that the glitches alter the spatial distribution of the sample's quasi-elastic X-ray scattering. Because glitches result from additional Bragg reflections, multiple-beam dynamical diffraction theory is necessary to understand their effects. Here, the glitches of the Si(111) four-bounce monochromator of I20-scanning just above the Ni K edge are associated with their Bragg reflections. A fitting procedure that treats coherent and Compton scattering is developed and applied to a sample of an extremely dilute (100 micromolal) aqueous solution of Ni(NO 3 ) 2 . The depolarization of the wiggler X-ray beam out of the electron orbit is modeled. The fits achieve good agreement with the sample's quasi-elastic scattering with just a few parameters. The X-ray polarization is rotated up to ±4.3° within the glitches, as predicted by dynamical diffraction. These results will help users normalize EXAFS data at glitches.

Sutter, John P.↗

RECENT RESULTS AND OPPORTUNITIES AT THE IOTA FACILITY

The Integrable Optics Test Accelerator (IOTA) was recently commissioned as part of the Fermilab Accelerator Science and Technology (FAST) facility. The IOTA ring was briefly operated with electrons at 47 MeV followed by a 6-months run with 100 MeV electrons. The main goal of the first runwas to study beam dynamics in the integrable lattices with elliptical nonlinear magnets and in the quasi-integrable case with profiled octupole channel. The flexibility of the IOTA ring allowed a wide range of complementary studies, such as experiments with a single electron; studies of fluctuations in undulator radiation and operation with low emittance beams. Over the next year the proton injector will be installed and two runs carried out. One run will be dedicated to the refinement of nonlinear experiments and another will be dedicated to the proof-of-principle demonstration of Optical Stochastic Cooling.

43 PARTICLE ACCELERATORS↗

Load responsive multilayer insulation performance testing

Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

42 ENGINEERING↗

High Performance Computing Modeling Advances Accelerator Science for High-Energy Physics

The development and optimization of particle accelerators are essential for advancing our understanding of the properties of matter, energy, space, and time. Particle accelerators are complex devices whose behavior involves many physical effects on multiple scales. Therefore, advanced computational tools utilizing high-performance computing are essential for accurately modeling them. In the past decade, the US Department of Energy's SciDAC program has produced accelerator-modeling tools that have been employed to tackle some of the most difficult accelerator science problems. The authors discuss the Synergia framework and its applications to high-intensity particle accelerator physics. Synergia is an accelerator simulation package capable of handling the entire spectrum of beam dynamics simulations. Our authors present Synergia's design principles and its performance on HPC platforms.

43 PARTICLE ACCELERATORS↗

STATUS OF THE JLEIC ION COLLIDER RING DESIGN

We present an update on the lattice design and beam dynamics study of the ion collider ring of JLEIC (Jefferson Lab Electron Ion Collider). The collider ring consists of two 261.7 degree arcs connected by two straight sections crossing each other. One of the straights houses an interaction region (IR) and is shaped to make a 50 mrad crossing angle with the electron beam at the interaction point (IP) to meet physics requirements. The forward acceptance requirements downstream of the IP in the ion direction lead to an asymmetric IR lattice design. The detector solenoid effects and the multipole fields of the IR magnets further complicate this picture. In this paper, compensation of the detector solenoid effects is considered together with orbit correction and multipole effects. We also study local compensation of the magnet multipoles using dedicated multipole correctors. And an optimization of the betatron tunes is also presented.

Wei, Guohui↗

Development of a pepper-pot emittance meter for diagnostics of low-energy multiply charged heavy ion beams extracted from an ECR ion source

Several fluorescent materials were tested for use in the imaging screen of a pepper-pot emittance meter that is suitable for investigating the beam dynamics of multiply charged heavy ions extracted from an ECR ion source. SiO{sub 2} (quartz), KBr, Eu-doped CaF{sub 2}, and Tl-doped CsI crystals were first irradiated with 6.52-keV protons to determine the effects of radiation damage on their fluorescence emission properties. For such a low-energy proton beam, only the quartz was found to be a suitable fluorescent material, since the other materials suffered a decay in fluorescence intensity with irradiation time. Subsequently, quartz was irradiated with heavy {sup 12}C{sup 4+}, {sup 16}O{sup 4+}, and {sup 40}Ar{sup 11+} ions, but it was found that the fluorescence intensity decreased too rapidly to measure the emittance of these heavy-ion beams. These results suggest that a different energy loss mechanism occurs for heavier ions and for protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗