Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure

A single-molecule three-dimensional (3D) structure is essential for understanding the thermal vibrations and dynamics as well as the conformational changes during the chemical reaction of macromolecules. Individual-particle electron tomography (IPET) is an approach for obtaining a snap-shot 3D structure of an individual macromolecule particle by aligning the tilt series of electron tomographic (ET) images of a targeted particle through a focused iterative 3D reconstruction method. The method can reduce the influence on the 3D reconstruction from large-scale image distortion and deformation. Due to the mechanical tilt limitation, 3D reconstruction often contains missing-wedge artifacts, presented as elongation and an anisotropic resolution. Here, we report a post-processing method to correct the missing-wedge artifact. This low-tilt tomographic reconstruction (LoTToR) method contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination.

97 MATHEMATICS AND COMPUTING↗

Detailed arsenic concentration profiles at Si/SiO{sub 2} interfaces

The pile-up of arsenic at the Si/SiO{sub 2} interface after As implantation and annealing was investigated by high resolution Z-contrast imaging, electron energy-loss spectroscopy (EELS), grazing incidence x-ray fluorescence spectroscopy (GI-XRF), secondary ion mass spectrometry, x-ray photoelectron spectroscopy, Rutherford backscattering spectrometry, as well as Hall mobility and four-point probe resistivity measurements. After properly taking into account their respective artifacts, the results of all methods are compatible with each other, with EELS and GI-XRF combined with etching providing similar spatial resolution on the nanometer scale for the dopant profile. The sheet concentration of the piled-up As at the interface was found to be {approx}1x10{sup 15} cm{sup -2} for an implanted dose of 1x10{sup 16} cm{sup -2} with a maximum concentration of {approx}10 at. %. The strain observed in the Z-contrast images also suggests a significant concentration of local distortions within 3 nm from the interface, which, however, do not seem to involve intrinsic point defects.

36 MATERIALS SCIENCE↗

LOW SCATTER, HIGH KILOVOLT, A-SI FLAT PANEL X-RAY DETECTOR

We have been using amorphous silicon (a-Si) flat panel detectors in high energy (>400 kV) cone beam computed tomography (CT) applications for a number of years. We have found that these detectors have a significant amount of internal scatter that degrades the accuracy of attenuation images. The scatter errors cause cupping and streaking artifacts that are practically indistinguishable from beam hardening artifacts. Residual artifacts remain after beam hardening correction and over correction increases noise in CT reconstructions. Another important limitation of existing detectors is that they have a high failure rate, especially when operating at megavolt x-ray energies even with a well collimated beam. Due to the limitations of the current detectors, we decided to design a detector specifically for high energies that has significantly reduced scatter. In collaboration with IMTEC, we have built a prototype amorphous silicon flat panel detector that has both improved imaging response and increased lifetime. LANL's contribution is the ''transparent panel concept''(patent pending), in which structures in the x-ray beam path are either eliminated or made as transparent to x-rays as practical (low atomic number and low areal density). This reduces scatter, makes attenuation measurements more accurate, improves the ability to make corrections for beam hardening, and increases signal to noise ratio in DR images and CT reconstructions. IMTEC's contribution is an improved shielding design that will increase the lifetime of the panel. Preliminary results showing the dramatic reduction in self scatter from the panel will be presented as well as the effect of this improvement on CT images.

36 MATERIALS SCIENCE↗

Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging

Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 {mu}m and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the Imaging and Medical Beamline at the Australian Synchrotron.Overcoming these challenges has permitted increasingly sophisticated imaging of animals with synchrotron X-rays, and we expect a bright future for these techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Beam Hardening Correction Method for a microCT Scanner Prototype

The radiographic projections acquired with a microCT were simulated and then corrected for beam hardening effects using the linearized signal to equivalent thickness (LSET) method. This procedure requires a calibration signal for each pixel obtained from a set of images with filters of increasing thickness. The projections are corrected by converting the signal to an equivalent thickness using interpolation over the calibration images. The method was validated using simulated projections of different phantoms. Two calibration sets were simulated using aluminum and water filters of thicknesses ranging from 0 to 5 mm and from 0 to 50 mm, respectively. A simulation of the phantoms' projections using a monoenergetic beam was also obtained to establish the relative intensity on the tomographic images when no cupping artifacts are present. Comparison between corrected and uncorrected tomographic images shows that the LSET method effectively corrects the cupping artifact. Streaking artifacts correction with the LSET method shows better results than with the traditional water correction method. Results are independent of the two calibration materials used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Scanning Geometry to Collect 3D-Geometry Data in Flat Samples

3D integration through silicon technology of integrated circuits challenges non-destructive testing methods. 3D x-ray methods are the techniques of choice to localize defects in interconnects. The development of high-power x-ray sources enabled the use of x-ray microscopy in laboratory tools. Those devices are able to resolve features down to 40 nm in an acceptable measurement time. However, the field of view is very limited to 16 {mu}m in high-resolution mode and to 65 {mu}m in large-field-of-view mode. To record tomography data, the size of the samples must not exceed the field of view to circumvent specific artifacts. Semiconductor samples usually do not fulfill the condition mentioned above since they have the shape of flat sheets. Therefore limited-angle tomography is typically used. The missing angles cause typical capping artifacts and poor signal-to-noise ratio. We present a modified scanning geometry that overcomes some of the artifacts and yields a better image quality. The geometry and potential applications are presented in comparison to the traditional limited-angle tomography.

07 ISOTOPE AND RADIATION SOURCES↗

Anisotropic elliptical dichroism and influence of imperfection of circular polarization upon anisotropic circular dichroism

In spite of the importance of anisotropic circular dichroism, in practice, it is difficult to get rid of the artifacts that arise from the imperfection of the circular polarization. Undesirable linear dichroism, interference of two orthogonal polarization states, and linear birefringence prevent us from making accurate measurements. We propose a theoretical method for evaluating the contributions of the first two, which are thought to be the main artifacts when specimens are not thick enough. Using the time-dependent perturbation theory and taking into account the direction of light propagation toward an orientationally fixed molecule, we formulated the transition probability of systems perturbed by arbitrarily polarized light and the absorption difference associated with two kinds of polarized light. We also formulated, as an extension of the dissymmetry factor of circular dichroism, a newly defined dissymmetry factor associated with two arbitrary polarization states. Furthermore, we considered a mixed-state of photon ensemble in which polarization states distribute at a certain width around a certain average. Although the purity of polarization and ellipticity does not correspond immediately, by considering the mixed state it is possible to treat them consistently. We used quantum statistical mechanics to describe the absorption difference for two kinds of photon ensembles and applied the consequent formula to examine the reported experimental results of single-molecule chiroptical responses under discussion in the recent past. The artifacts are theoretically suggested to be sensitive to the incident direction of elliptically polarized light and to the oriented systems, the ellipticity, and the orientation of ellipse. The mixed state has little, if any, effect when the polarization state distribution is narrow.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of dynamic specimen shape evolution on the atom probe tomography results of doped epitaxial oxide multilayers: Comparison of experiment and simulation

The experimental atom probe tomography (APT) results from two different specimen orientations (top-down and sideways) of a high oxygen ion conducting Samaria-doped-ceria/Scandia-stabilized-zirconia multilayer thin film solid oxide fuel cell electrolyte was compared with level-set method based field evaporation simulations for the same specimen orientations. This experiment-simulation comparison explains the dynamic specimen shape evolution and ion trajectory aberrations that can induce density artifacts in final reconstruction, leading to inaccurate estimation of interfacial intermixing. This study highlights the importance of comparing experimental results with field evaporation simulations when using APT to study oxide heterostructure interfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advances in x-ray framing cameras at the National Ignition Facility to improve quantitative precision in x-ray imaging

We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement for gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. Furthermore, we have developed a device that can be added to the framing camera head to prevent these artifacts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ideal conductor/dielectric model (ICDM): A generalized technique to correct for finite-size effects in molecular simulations of hindered ion transport

Molecular simulations serve as indispensable tools for investigating the kinetics and elucidating the mechanism of hindered ion transport across nanoporous membranes. In particular, recent advancements in advanced sampling techniques have made it possible to access translocation timescales spanning several orders of magnitude. In our prior study [Shoemaker et al., J. Chem. Theory Comput. 18, 7142 (2022)], we identified significant finite size artifacts in simulations of pressure-driven hindered ion transport through nanoporous graphitic membranes. We introduced the ideal conductor model, which effectively corrects for such artifacts by assuming the feed to be an ideal conductor. In the present work, we introduce the ideal conductor dielectric model (Icdm), a generalization of our earlier model, which accounts for the dielectric properties of both the membrane and the filtrate. Using the Icdm model substantially enhances the agreement among corrected free energy profiles obtained from systems of varying sizes, with notable improvements observed in regions proximate to the pore exit. Moreover, the model has the capability to consider secondary ion passage events, including the transport of a co-ion subsequent to the traversal of a counter-ion, a feature that is absent in our original model. We also investigate the sensitivity of the new model to various implementation details. The Icdm model offers a universally applicable framework for addressing finite size artifacts in molecular simulations of ion transport. It stands as a significant advancement in our quest to use molecular simulations to comprehensively understand and manipulate ion transport processes through nanoporous membranes.

Chemistry↗

A full-sky, high-resolution atlas of galactic 12 μm dust emission with WISE

We describe our custom processing of the entire Wide-field Infrared Survey Explorer (WISE) 12 μm imaging data set, and present a high-resolution, full-sky map of diffuse Galactic dust emission that is free of compact sources and other contaminating artifacts. The principal distinctions between our resulting co-added images and the WISE Atlas stacks are our removal of compact sources, including their associated electronic and optical artifacts, and our preservation of spatial modes larger than 1.°5. We provide access to the resulting full-sky map via a set of 430 12.°5 × 12.°5 mosaics. These stacks have been smoothed to 15'' resolution and are accompanied by corresponding coverage maps, artifact images, and bit-masks for point sources, resolved compact sources, and other defects. When combined appropriately with other mid-infrared and far-infrared data sets, we expect our WISE 12 μm co-adds to form the basis for a full-sky dust extinction map with angular resolution several times better than Schlegel et al.

79 ASTRONOMY AND ASTROPHYSICS↗

Archaeometallurgy using synchrotron radiation: a review

Archaeometallurgy is an important field of study which allows us to assess the quality and value of ancient metal artifacts and better understand the ancient cultures that made them. Scientific investigation of ancient metal artifacts is often necessary due to their lack of well-documented histories. One important requirement of analytical techniques is that they be non-destructive, since many of these artifacts are unique and irreplaceable. Most synchrotron radiation (SR) techniques meet this requirement. In this review, the characteristics, capabilities, and advantages and disadvantages of current and future SR facilities are discussed. I examine the application of SR techniques such as x-ray imaging (radiography/microscopy and tomography), x-ray diffraction, x-ray fluorescence, x-ray spectroscopy, Fourier transform infrared spectroscopy, and lastly combined SR techniques to the field of archaeometallurgy. Previous case studies using these various SR techniques are discussed and potential future SR techniques are addressed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ERSAP: Toward Better NP Data-Stream Analytics With Flow-Based Programming

This paper presents an reactive, actor-model and FBP paradigm based framework that we develop to design data-stream processing applications for HEP and NP. This framework encourages a functional decomposition of the overall data processing application into small mono-functional artifacts. Artifacts that are easy to understand, develop, deploy and debug. The fact that these artifacts (actors) are programmatically independent they can be scaled and optimized independently, which is impossible to do for components of the monolithic application. One of the important advantages of this approach is fault tolerance where independent actors can come and go on the data-stream without forcing the entire application to crash. Furthermore, it also makes it is easy to locate the faulty actor in the data pipeline. Due the fact that the actors are loosely coupled, and that the data (inevitably) carries the context, they can run on heterogeneous environments, utilizing different accelerators. This paper describes the main design concepts of the framework and presents a ?proof of concept? application design and deployment results obtain processing on-beam calorimeter streaming data.

Gyurjyan, V.↗

Practical considerations in using a binary pseudorandom array for instrument transfer function calibration

Binary pseudo-random array (BPRA) artifacts are useful devices for calibrating the instrument transfer function (ITF) of interferometric microscopes and other optical and non-optical surface and wavefront measurement instruments. The intrinsic white noise character of the power spectral density function of the artifact simplifies the deconvolution of the ITF from the measured power spectral density (PSD). However, resampling of the BPRA intrinsic artifact features with the measurement tool's specific sampling pattern modifies the white noise character of the intrinsic spectrum and needs to be accounted for in the ITF-based data deconvolution process. We have developed an analytic solution to the spectrum of a resampled one- and two- dimensional BPRA. The resultant nominal PSD function is a simple twoparameter cosine function with a period equal to the resampled pixel width. A transfer function model for interferometric microscopes that incorporates this function, along with an ITF that includes aliasing effects and variable numerical aperture (NA), wavelength, and obscuration factor, is used to fit to the BPRA PSDs measured by an interference microscope for a range of objective and zoom lens magnification combinations.

Takacs, PZ↗

Binary pseudo-random array (BPRA) for inspection and calibration for cylindrical wavefront interferometry

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. However, surface topography measurements are instrument dependent, and without the knowledge of how the instrument performs under the practical usage conditions, the measured data contain some degree of uncertainty. Binary Pseudo Random Array (BPRA) “white noise” artifact are effective and useful for characterizing the Instrument Transfer Function (ITF) of surface topography metrology tools and wavefront measurement instrument. BPRA artifact contains features with all spatial frequencies in the instrument bandpass with equal weight. As a result, power spectral density of the patterns has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range. The application examples include electron microscopes, x-ray microscopes, interferometric microscopes, and large field-of-view Fizeau Interferometers. Furthermore, we will introduce the application of BPRA method to characterizing the ITF of Cylindrical Wavefront Interferometry (CWI), by developing the BPRA artifact which matches the radius of curvature of the cylindrical wavefront. The data acquisition and analysis procedures for different applications of the ITF calibration technique developed are also discussed.

Munechika, K↗

Region-of-interest image reconstruction in circular cone-beam microCT

Cone-beam microcomputed tomography (microCT) is one of the most popular choices for small animal imaging which is becoming an important tool for studying animal models with transplanted diseases. Region-of-interest (ROI) imaging techniques in CT, which can reconstruct an ROI image from the projection data set of the ROI, can be used not only for reducing imaging-radiation exposure to the subject and scatters to the detector but also for potentially increasing spatial resolution of the reconstructed images. Increasing spatial resolution in microCT images can facilitate improved accuracy in many assessment tasks. A method proposed previously for increasing CT image spatial resolution entails the exploitation of the geometric magnification in cone-beam CT. Due to finite detector size, however, this method can lead to data truncation for a large geometric magnification. The Feldkamp-Davis-Kress (FDK) algorithm yields images with artifacts when truncated data are used, whereas the recently developed backprojection filtration (BPF) algorithm is capable of reconstructing ROI images without truncation artifacts from truncated cone-beam data. We apply the BPF algorithm to reconstructing ROI images from truncated data of three different objects acquired by our circular cone-beam microCT system. Reconstructed images by use of the FDK and BPF algorithms from both truncated and nontruncated cone-beam data are compared. The results of the experimental studies demonstrate that, from certain truncated data, the BPF algorithm can reconstruct ROI images with quality comparable to that reconstructed from nontruncated data. In contrast, the FDK algorithm yields ROI images with truncation artifacts. Therefore, an implication of the studies is that, when truncated data are acquired with a configuration of a large geometric magnification, the BPF algorithm can be used for effective enhancement of the spatial resolution of a ROI image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving accuracy of electron density measurement in the presence of metallic implants using orthovoltage computed tomography

The goal of this study was to evaluate the improvement in electron density measurement and metal artifact reduction using orthovoltage computed tomography (OVCT) imaging compared with conventional kilovoltage CT (KVCT). For this study, a bench-top system was constructed with adjustable x-ray tube voltage up to 320 kVp. A commercial tissue-characterization phantom loaded with inserts of various human tissue substitutes was imaged using 125 kVp (KVCT) and 320 kVp (OVCT) x rays. Stoichiometric calibration was performed for both KVCT and OVCT imaging using the Schneider method. The metal inserts--titanium rods and aluminum rods--were used to study the impact of metal artifacts on the electron-density measurements both inside and outside the metal inserts. It was found that the relationships between Hounsfield units and relative electron densities (to water) were more predictable for OVCT than KVCT. Unlike KVCT, the stoichiometric calibration for OVCT was insensitive to the use of tissue substitutes for direct electron density calibration. OVCT was found to significantly reduce metal streak artifacts. Errors in electron-density measurements within uniform tissue substitutes were reduced from 42% (maximum) and 18% (root-mean-square) in KVCT to 12% and 2% in OVCT, respectively. Improvements were also observed inside the metal implants. For the detectors optimized for KVCT, the imaging dose is almost doubled for OVCT for the image quality comparable to KVCT. OVCT may be a good option for high-precision radiotherapy treatment planning, especially for patients with metal implants and especially for charged particle therapy, such as proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration

Purpose: lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. Methods and Materials: 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Results: Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods <0.5 mm for all directions) for the tumor region. From visual assessment, the registration was good for the clearly visible features (e.g., tumor and diaphragm). The shape of the tumor, with respect to that of the BH CT scan, was better represented by the MidP reconstructions than any of the 4D CT frames (including MidV; reduction of 'shape differences' was 66%). The MidP scans contained about one-third the noise of individual 4D CT scan frames. Conclusions: We implemented an accurate method to estimate the motion of structures in a 4D CT scan. Subsequently, a novel method to create a midposition CT scan (time-weighted average of the anatomy) for treatment planning with reduced noise and artifacts was introduced. Tumor shape and position in the MidP CT scan represents that of the BH CT scan better than MidV CT scan and, therefore, was found to be appropriate for treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗