Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Clinical Application of a New Indwelling Catheter with a Side-Hole and Spirally Arranged Shape-Memory Alloy for Hepatic Arterial Infusion Chemotherapy

A new indwelling catheter, G-spiral (GSP), was developed for hepatic arterial infusion chemotherapy (HAIC) by way of an implanted catheter-port system (CPS). Here we evaluated its physical properties and the outcomes of its clinical use. The GSP vessel-fixing power and its ability to follow a guidewire were determined with a vascular in vitro model, and Student t test was used to determine statistical significance (P < 0.05). A retrospective analysis was performed to evaluate the technical success rate and to identify the clinical complications associated with radiologic CPS implantation with GSP in 65 patients with unresectable hepatic tumors. The mean vessel-fixing power of the GSP (14.4 g) significantly differed from that of a GSP with a cut shape-memory alloy (3.3 g). The mean resistance to following the guidewire displayed by the GSP (88.5 g) was significantly less than that for a 5F W-spiral (106.3 g) or 4F Cobra-type angiographic catheter (117.8 g). The CPS was placed successfully in 64 of 65 cases (98.5%). Hepatic artery occlusion was observed in one case. Occlusion, cracking, and infection of CPS were observed in one, two, and one case, respectively. The GSP is a highly useful indwelling catheter that can be used for HAIC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standard of Practice for the Interventional Management of Isolated Iliac Artery Aneurysms

Isolated iliac artery aneurysms are uncommon, comprising less than 2% of all abdominal aneurysmal disease. Although they have a fairly innocuous natural history, when they have attained a large size they carry a significant risk of rupture. Rupture is associated with significant morbidity and mortality. Therefore, an early diagnosis and treatment are crucial. Over the last decade, interventional treatment options have become established alternatives to open surgical repair. These guidelines aim to review the pathogenesis, natural history, and presentation of isolated iliac artery aneurysms including a description of imaging and interventional treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aneurysm of an Anomalous Systemic Artery Supplying the Normal Basal Segments of the Left Lower Lobe: Endovascular Treatment with the Amplatzer Vascular Plug II and Coils

An anomalous systemic artery originating from the descending thoracic aorta supplying the normal basal segments of the lower lobe of the left lung without sequestration is a rare congenital anomaly. The published surgical treatments include lobectomy, segmentectomy, anastomosis, and ligation. In addition, endovascular treatment with coils has been reported. A second-generation occluder, the Amplatzer Vascular Plug II (AVP II), has a central plug and two occlusion disks and a finer, more densely woven nitinol wire, thus enabling faster embolization. This published case is the first successful occlusion of an aneurysm of an anomalous systemic artery with the AVP II and fibered coils, with 10 months of follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Standard Pushable Coils with Fibered Interlock Detachable Coils

The purpose of this study was compare embolization of the gastroduodenal artery (GDA) using standard pushable coils with the Interlock detachable coil (IDC), a novel fibered mechanically detachable long microcoil, in patients scheduled for selective internal radiotherapy (SIRT). Fifty patients (31 male and 19 female; median age 66.6 {+-} 8.1 years) were prospectively randomized for embolization using either standard coils or IDCs. Procedure time, radiation dose, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography were recorded. The procedures differed significantly in time (14:32 {+-} 5:56 min for standard coils vs. 2:13 {+-} 1:04 min for IDCs; p < 0.001); radiation dose for coil deployment (2479 {+-} 1237 cGycm Superscript-Two for standard coils vs. 275 {+-} 268 cGycm Superscript-Two for IDCs; p < 0.001); and vessel occlusion (17:18 {+-} 6:39 min for standard coils vs. 11:19 {+-} 7:54 min for IDCs; p = 0.002). A mean of 6.2 {+-} 1.8 coils (n = 27) were used in the standard coil group, and 1.3 {+-} 0.9 coils (p < 0.0001) were used in the IDC group (n = 23) because additional pushable coils were required to achieve GDA occlusion in 4 patients. In 2 patients, the IDC could not be deployed through a Soft-VU catheter. One standard coil dislodged in the hepatic artery and was retrieved. Vessel reperfusion was noted in only 1 patient in the standard coil group. Controlled embolization of the GDA with fibered IDCs was achieved more rapidly than with pushable coils. However, vessel occlusion may not be obtained using a single device only, and the use of sharply angled guiding catheters hampered coil pushability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Reintervention After Endovascular Repair of Isolated Iliac Artery Aneurysm

The objective of this study was to identify factors predicting the need for reintervention after endovascular repair of isolated iliac artery aneurysm (IIAA). We reviewed prospectively collected database records of all patients who underwent endovascular repair of IIAA between 1999 and 2008. Detailed assessment of the aneurysms was performed using computed tomography angiography (CTA). Follow-up protocol included CTA at 3 months. If this showed no complication, then annual duplex scan was arranged. Multivariate analysis and analysis of patient survival and freedom from reintervention were performed using Kaplan-Meier life tables. Forty IIAAs (median diameter 44 mm) in 38 patients were treated (all men; median age 75 years), and median follow-up was 27 months. Endovascular repair of IIAA was required in 14 of 40 aneurysms (35%). The rate of type I endoleak was significantly higher with proximal landing zone (PLZ) diameter >30 mm in the aorta or >24 mm in the common iliac artery or distal landing zone (DLZ) diameter >24 mm (P = 0.03, 0.03, and 0.0014, respectively). Reintervention rate (RR) increased significantly with increased diameter or decreased length of PLZ; increased DLZ diameter; and endovascular IIAA repair (P = 0.005, 0.005, 0.02, and 0.02 respectively); however, RR was not significantly affected by length of PLZ or DLZ. Freedom-from-reintervention was 97, 93, and 86% at 12, 24, and 108 months. There was no in-hospital or aneurysm-related mortality. Endovascular IIAA repair is a safe treatment option. Proper patient selection is essential to decrease the RR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iatrogenic Aortic Dissection During Left Subclavian Artery Stenting: Immediate Detection by Calcium Sign Under Fluoroscope

Calcified aorta with acute iatrogenic aortic dissection is a potential but rarely reported complication of subclavian or innominate artery intervention. We report a patient who developed aortic dissection during stenting for left subclavian artery. A newly developed 'calcium sign,' signifying displacement of the intimal calcification from the outer soft-tissue margin and which is traditionally recognized on chest radiograph, was detected by real-time fluoroscopy and served as the diagnostic clue. Type B aortic dissection was further confirmed by chest computed tomography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cryoplasty Versus Conventional Balloon Angioplasty of the Femoropopliteal Artery in Diabetic Patients: Long-Term Results from a Prospective Randomized Single-Center Controlled Trial

The purpose of this study was to investigate the immediate and long-term results of cryoplasty versus conventional balloon angioplasty in the femoropopliteal artery of diabetic patients. Fifty diabetic patients (41 men, mean age 68 years) were randomized to cryoplasty (group CRYO; 24 patients with 31 lesions) or conventional balloon angioplasty (group COBA; 26 patients with 34 lesions) of the femoropopliteal artery. Technical success was defined as <30% residual stenosis without any adjunctive stenting. Primary end points included technical success, primary patency, binary in-lesion restenosis (>50%), and freedom from target lesion recanalization. Cox proportional hazards regression analysis was performed to adjust for confounding factors of heterogeneity. In total, 61.3% (19 of 31) in group CRYO and 52.9% (18 of 34) in group COBA were de novo lesions. More than 70% of the lesions were Transatlantic Inter-Society Consensus (TASC) B and C in both groups, and 41.4% of the patients in group CRYO and 38.7% in group COBA suffered from critical limb ischemia. Immediate technical success rate was 58.0% in group CRYO versus 64.0% in group COBA (p = 0.29). According to 3-year Kaplan-Meier estimates, there were no significant differences with regard to patient survival (86.8% in group CRYO vs. 87.0% in group COBA, p = 0.54) and limb salvage (95.8 vs. 92.1% in groups CRYO and COBA, respectively, p = 0.60). There was a nonsignificant trend of increased binary restenosis in group CRYO (hazard ratio [HR] 1.3; 95% CI 0.6-2.6, p = 0.45). Primary patency was significantly lower in group CRYO compared with group COBA (HR 2.2; 95% CI 1.1-4.3, p = 0.02). Significantly more repeat intervention events because of recurrent symptoms were required in group CRYO (HR 2.5; 95% CI 1.2-5.3, p = 0.01). Cryoplasty was associated with lower primary patency and more clinically driven repeat procedures after long-term follow-up compared with conventional balloon angioplasty.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superior Mesenteric Artery Embolism Treated with Percutaneous Mechanical Thrombectomy

A case of acute superior mesenteric artery embolism treated with percutaneous thrombus aspiration is described. A 63-year-old man with chronic atrial fibrillation was admitted to the hospital with progressive abdominal pain. Computed tomography angiography revealed an occlusion of the distal part of the superior mesenteric artery. The patient was effectively treated using transaxillary percutaneous mechanical thrombectomy using a 6F Aspirex thrombectomy catheter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean {+-} SD age 67 {+-} 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70-100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of the Amplatzer Vascular Plug in Splenic Artery Embolization: A Comparison Study with Conventional Coil Technique

Purpose: To retrospectively evaluate the role of the Amplatzer Vascular Plug (AVP) in proximal splenic artery embolization (SAE) compared with coils. Materials and Methods: Forty patients had proximal SAE performed with AVP(s) or coils as the primary embolic agent for splenic artery steal syndrome (n = 23), trauma (n = 5), portal hypertension (n = 5), bleeding due to pancreatic pathology (n = 4), and pre-splenectomy (n = 3). Comparisons were made of occlusion and procedure time, cost, and radiation dose. Results: Eighteen proximal SAE procedures were successfully performed with AVP. Twenty-two procedures were performed with coils, including one failed AVP attempt, which was completed with coils. Precise deployment without migration was achieved in all 18 AVP cases. Seven of 22 (31.8%) coil procedures had distal migration without consequence. There was no statistically significant difference in mean occlusion time (24.4 min for AVP vs. 31.5 min for coils, P = 0.13), procedure time (43.7 min for AVP vs. 53.8 min for coils, P = 0.16), or cost ($1474.13 for AVP vs. $1722.51 for coils, P = 0.69). There was significant difference in radiation dose (842 mGy for AVP vs. 1,309 mGy for coils, P = 0.04). Fourteen of the 18 (78%) AVP devices required additional embolic material. Conclusions: AVP with additional embolic agents is a useful alternative for proximal SAE because of precise deployment, resistance to migration, and radiation reduction. AVP use may be limited by vessel tortuosity. The occlusion time, procedure time, and cost were reduced but this was not statistically significant due to the need for additional embolic material.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Midterm Results of Uterine Artery Embolization Using Narrow-Size Calibrated Embozene Microspheres

Purpose: To evaluate safety and efficacy of uterine artery embolization using narrow-size-range polyphosphazene-coated hydrogel microspheres (Embozene, CeloNova Biosciences, Newnan, GA). Methods: Between May 2006 and September 2008, a total of 121 consecutive patients (mean {+-} SD age 42.1 {+-} 5.4 years, range 30.5-51.5 years) were enrolled onto this single-center study. The primary study endpoint was safety as assessed by the society of interventional radiology (SIR) classification. The secondary endpoint was efficacy, which was based on a 1-year magnetic resonance imaging study and relief of symptoms documented by the Medical Outcomes Study 36-Item Short-Form Health Survey questionnaire over a 2-year interval. Results: The mean {+-} SD diameter of the dominant fibroid was 6.4 {+-} 2.6 (range, 2.9-13.9) cm and the mean volume 137.2 {+-} 245.1 (range, 5.3-1184) ml. Most patients had multiple fibroids with 11% more than 10. A total of 240 of 242 interventions were completed as planned, a technical success rate of 99.2%. According to the SIR classification, one type A, eight type C, and one type D complication occurred. Total devascularization was noted in 96% (116 of 121) of dominant fibroids. Volume decrease was 4% at 2 weeks, 52% (P < 0.001) at 3 months, 78% (P < 0.001) at 6 months, and 91% at 12 months (P < 0.001). The latter difference was statistically significant (P = 0.007). A total of 92% had improved hypermenorrhea at 1 year and 94% at 2 years. Dysmenorrhea was improved in 96% at 1 year and in 95% at 2 years. The overall health status score was 60.4 {+-} 26.2 points at baseline and 96.9 {+-} 3.8 after 1 year (P = 0.0019).ConclusionUterine artery embolization with Embozene microspheres is a safe procedure. Its efficacy is demonstrated by high fibroid devascularization and volume reduction rates and significant improvements of clinical symptoms and quality-of-life scores during follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-Expanding Nitinol Renal Artery Stents: Comparison of Safety and Efficacy of Bare Versus Polyzene-F Nanocoated Stents in a Porcine Model

Objective: To investigate the safety and efficacy of a Polyzene-F nanocoat on new low-profile self-expandable nitinol stents in minipig renal arteries. Materials and Methods: Ten bare nitinol stents (BNS) and 10 stents coated with a 50 nm-thin Polyzene-F coating were randomly implanted into renal arteries of 10 minipigs (4- and 12-week follow-up, 5 animals/group). Thrombogenicity, on-stent surface endothelialization, vessel wall injury, late in-stent stenosis, and peristrut vessel wall inflammation were determined by quantitative angiography and postmortem histomorphometry. Results: In 6 of 10 BNS, >50% stenosis was found, but no stenosis was found in stents with a nanothin Polyzene-F coating. Histomorphometry showed a statistically significant (p < 0.05) different average maximum luminal loss of 55.16% {+-} 8.43% at 12 weeks in BNS versus 39.77% {+-} 7.41% in stents with a nanothin Polyzene-F coating. Stents with a nanothin Polyzene-F coating had a significantly (p < 0.05) lower inflammation score after 12 weeks, 1.31 {+-} 1.17 versus 2.17 {+-} 0.85 in BNS. The results for vessel wall injury (0.6 {+-} 0.58 for Polyzene-F-coated stents; 0.72 {+-} 0.98 for BNS) and re-endothelialization, (1.16 {+-} 0.43 and 1.23 {+-} 0.54, respectively) were not statistically significant at 12-week follow-up. No thrombus deposition was observed on the stents at either follow-up time point. Conclusion: Nitinol stents with a nanothin Polyzene-F coating successfully decreased in-stent stenosis and vessel wall inflammation compared with BNS. Endothelialization and vessel wall injury were found to be equal. These studies warrant long-term pig studies ({>=}120 days) because 12 weeks may not be sufficient time for complete healing; thereafter, human studies may be warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemoembolization for Hepatocellular Carcinoma Supplied Exclusively by the Hepatic Falciform Artery

Purpose: The purpose of this study was to describe imaging appearances of hepatocellular carcinoma (HCC) supplied exclusively by the hepatic falciform artery (HFA) and safety of chemoembolization via the HFA. Methods: During the past 6 years, we have performed chemoembolization for the treatment of 12 patients with HCCs supplied exclusively by the HFA. Computed tomography (CT) scans, digital subtraction angiograms, and medical records were retrospectively reviewed by consensus. Results: Tumors were located in Couinaud segments IV (n = 7) and III (n = 5) and in subcapsular areas around the falciform ligaments. Tumor size ranged from 1.0 to 1.8 cm (mean, 1.3 cm; median, 1.3 cm). HFAs originated from A4 (n = 7), A3 (n = 4), and the left hepatic artery near the umbilical point (n = 1). All tumors were supplied exclusively by the HFA. Prophylactic embolization of the distal HFA before chemoembolization was performed using gelatin sponge particles in only one patient, and selective chemoembolization via the HFA was achieved in all patients. One patient suffered from a skin rash after chemoembolization and recovered after conservative management. Individual responses of tumors supplied exclusively by the HFA were complete response (n = 8), partial response (n = 1), and stable disease (n = 2) at the first follow-up enhanced CT scan. Conclusions: The HFA can supply HCC located in subcapsular areas around the falciform ligament, and the tumors can be safely chemoembolized without significant complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of In-Stent Occlusion: New Technique for Recanalization of Long Superficial Femoral Artery Occlusion (Direct Stent Puncture Technique)

In-stent reocclusion is a frequent complication of endovascular treatment and stenting, especially in the superficial femoral artery. Neointimal hyperplasia is the main cause of this problem, but in many cases, it occurs as a result of the presence of stent strut fractures. The two treatment options are endovascular and surgical intervention. The effectiveness of endovascular interventions in patients with critical limb ischemia has been well established, but in some cases, crossing the occluded stent is difficult. We describe a new technique to recanalize long in-stent superficial femoral artery occlusions characterized by direct stent puncture, followed by retrograde-antegrade recanalization after antegrade failures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Entrapment of the StarClose Vascular Closure System After Attempted Common Femoral Artery Deployment

A complication of the StarClose Vascular Closure System (Abbott, Des Plaines, IL) after a transarterial hepatic chemoembolization is described. After attempted clip deployment, the entire device became lodged in the tissues overlying the common femoral artery and could not be removed percutaneously. Successful removal of the device required surgical cutdown for removal and arterial repair. Entrapment of the StarClose vascular closure deployment system is a potentially serious complication that has been reported in the Manufacturer and User Facility Device Experience database, but has not been recognized in the literature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Flow Control Technique Using Diluted Epinephrine in the N-butyl-2-cyanoacrylate Embolization of Visceral Artery Pseudoaneurysms Secondary to Chronic Pancreatitis

Although n-butyl-2-cyanoacrylate (NBCA) has been used as an effective liquid embolization material, its indication for pseudoaneurysms has seemingly been limited because of the technical difficulties of using NBCA, such as reflux to the parent artery and causing significant infarction. Thus, considerable skill in using NBCA or a device to control blood flow during its polymerization is required to achieve embolization without severe complications. We report our new technique for controlling blood flow using diluted epinephrine in transcatheter arterial NBCA embolization of five pseudoaneurysms in four cases secondary to hemosuccus pancreaticus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the Quality of Information Obtained About Uterine Artery Embolization From the Internet

Purpose: The Internet is widely used by patients to source health care-related information. We sought to analyse the quality of information available on the Internet about uterine artery embolization (UAE). Materials and Methods: We searched three major search engines for the phrase 'uterine artery embolization' and compiled the top 50 results from each engine. After excluding repeated sites, scientific articles, and links to documents, the remaining 50 sites were assessed using the LIDA instrument, which scores sites across the domains of accessibility, usability, and reliability. The Fleisch reading ease score (FRES) was calculated for each of the sites. Finally, we checked the country of origin and the presence of certification by the Health On the Net Foundation (HONcode) as well as their effect on LIDA and FRES scores.ResultsThe following mean scores were obtained: accessibility 48/60 (80%), usability 42/54 (77%), reliability 20/51 (39%), total LIDA 110/165 (67%), and FRES 42/100 (42%). Nine sites had HONcode certification, and this was associated with significantly greater (p < 0.05) reliability and total LIDA and FRES scores. When comparing sites between United Kingdom and United States, there was marked variation in the quality of results obtained when searching for information on UAE (p < 0.05). Conclusion: In general, sites were well designed and easy to use. However, many scored poorly on the reliability of their information either because they were produced in a non-evidence-based way or because they lacking currency. It is important that patients are guided to reputable, location-specific sources of information online, especially because prominent search engine rank does not guarantee reliability of information.

62 RADIOLOGY AND NUCLEAR MEDICINE↗