Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3-He detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Identifying Spectral Descriptors for Protonation in BaZr 0.8 Y 0.2 O 3-x with Electron Energy Loss Spectroscopy

Hydrogen economy is of paramount importance in the global transition to a sustainable, clean energy source that contributes to decarbonization efforts. In particular, the proton conducting proton ceramic fuel cells (PCFCs) play a crucial role in promoting hydrogen energy technology [1-5]. In a PCFC, the electrolyte is typically a solid oxide material that enables proton transport and can operate at temperatures lower than those of traditional oxygen ion conducting fuel cells [6]. The reduced operating temperature of PCFCs contributes to their durability, scalability, and efficiency [7,8]. BaZr 0.8 Y 0.2 O 3-x (BZY) is a promising proton conducting solid oxide electrolyte [9,10]. The emphasis on proton conductivity entails the importance of understanding proton content in the system. However, previous studies have largely relied on bulk techniques such as electrochemical impedance spectroscopy [7,11], Karl-Fischer titration [12,13], and thermogravimetric analysis [14] to obtain proton concentration. This is due to the small atomic size and light mass of hydrogen species making direct detection challenging. Bulk methods may be useful in estimating the proton content; however, it overlooks possible proton concentration gradient or segregation that may occur across or within a nanoparticle, especially when proton incorporation occurs nonuniformly through steam exposure on powder samples. In this paper, BZY is protonated at an estimated 0.15 mol of protons via steam exposure. Electron energy loss spectroscopy (EELS) with nanoscale spatial resolution is explored to identify proxy signals for proton detection using a JEOL ARM300 microscope operated at 300 kV with a Gatan GIF Continuum detector.

08 HYDROGEN↗

Theoretical light curve of a Type 2p supernova

The light curve and other observable diagnostics are presented for what should be a typical Type II 'plateau' supernova, the explosion of a 15 solar mass red supergiant. The calculations are carried out using a multi-frequency radiation transport code that includes opacity from all important mechanisms-bound-bound, bound-free, free-free, and electron scattering. It is found that the inclusion of opacity sources besides electron scattering increases the computed lenght of the plateau in the 15 solar mass model by approximately 30 days. Especially important is the ultraviolet cutoff caused by a thick forest of lines. Deposition and escape of gamma-rays from radioactive decay are also accurately simulated. We find that the presence of 0.06 solar mass of ejected Ni-56 extends the length of the plateau from approximately 100 days to approximately 140 dys. Because of the large hydrogen envleope and radius in this model, mixing does not appreciably alter the bolometric light curve, although it does change the gamma-ray light curve significantly. With 0.06 solar mass of ejected Ni-56, the unmixed (mixed) model peaks in escaping gamma-rays at 576 (466) days with gamma-ray luminosity of 3 x 10(exp 38) ergs/s. Except for the local group, the gamma-rays from an extragalactic 15 solar mass SNe IIp will be too faint to detect with any exsiting detectors. However, a Galactic SNe IIp would be quite bright and easily detectable.

Eastman, Ronald G.↗

RD53A: A large-scale prototype chip for the phase II upgrade in the serially powered HL-LHC pixel detectors

The phase II upgrade of the HL-LHC experiments within the LHC intends to deepen the studies of the Higgs boson and to allow the discovery of further particles by adding an integrated luminosity of about 4000 fb -1 over 10 years of operation. This upgrade would overwhelm the installed pixel detector readout chips with higher hit rates and radiation levels than ever before. To match these extreme requirements the RD53 collaboration, a joint effort between ATLAS and CMS, developed RD53A, a new generation pixel detector readout chip prototype manufactured in a 65 nm CMOS technology. It is half the size of the final pixel chips and designed to meet requirements in the face of 3 GHz/cm 2 hit rate after irradiation to 500 Mrad. The detector is able to use 50×50 μm 2 or 25×100 μm 2 pixels with high readout speed of up to 4 links per chip with 1.28 Gbit/s each. Shunt–LDO regulators integrated on the bottom of the chip provide the required voltages to the two power domains, analog and digital. These regulators enable serial powering of the pixel modules, which is the only feasible, radiation hard scheme to ensure acceptable power cable losses and to stay within the material budget for the future pixel detectors. Finally, an overview of the status and challenges of serial powering and the Shunt–LDO regulator development will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prelaunch Characterization and Performance of JPSS-3 VIIRS Reflective Solar Bands

The Joint Polar Satellite System 3 (JPSS-3) Visible Infrared Imaging Radiometer Suite (VIIRS) instrument is the fourth in a series (S-NPP VIIRS launched in October 2011, JPSS-1 VIIRS launched in November 2017, and JPSS-2 VIIRS currently undergoing spacecraft integration) of highly advanced polar-orbiting environmental satellites. JPSS-3 VIIRS underwent a comprehensive sensor-level Thermal Vacuum (TV) testing at the Raytheon Technologies El Segundo facility in the fall of 2020. While the test program provided characterization for many spatial, spectral, and radiometric aspects of the VIIRS sensor performance, this paper focuses on the radiometric performance of the 14 reflective solar bands (RSB) that cover the wavelength range from 0.41 to 2.3 μm. Key calibration parameters, such as the instrument gain, signal-to-noise ratio (SNR), dynamic range and radiometric uniformity, were derived in a TV environment for both the primary and redundant electronics at three instrument temperature plateaus: cold, nominal, and hot. This paper shows that all the JPSS-3 VIIRS RSB detectors have been well characterized, with the key performance metrics being comparable to those of the previous VIIRS instruments. Comparison of radiometric performance to sensor requirements, as well as a summary of key sensor testing and performance issues, will also be presented.

JPSS-3↗

Infrared spectroscopy of comets

An observational search for cometary parent molecules using infrared spectroscopy was conducted in the 1 to 5 micron region. The investigation involved two different observing programs, one at moderate spectral resolution and one at fairly high resolution. The lower resolution was used to study cometary spectra in the vicinity of 3.5 micron at wavelength/change in wavelength is approximately or equal to 10(exp 3). Comets P/Brorsen-Metcalf (1989o), Okazaki-Levy-Rudenko (1989r), and Austin (1990c1) were observed with the Cryogenic Spectrometer (CRSP) at Kitt Peak. The detector incorporated an InSb array with 58 spatial elements, each 2.7 min on the sky, and 62 spectral channels per spatial element. An, as yet, unidentified feature was detected at approximately 3.52 micron in Comet Austin (on 1990 May 4, 5, and 6). The feature is possibly present in P/Brorsen-Metcalf (observed on 1989 August 23 and 25), as well. Comet Okazaki-Levy-Rudenko exhibited continuum emission only in this spectral region at the time of the observations (1989 November 14 and 16). The data are presented, and the relationship between the 3.52 micron feature and cometary activity (e.g., water production rate, visibility of the 3.4 micron emission feature) are discussed. The high resolution program probed comet Austin in the 4.8 micron region. These observations were used to search for emission lines comprising the (1-0) vibration-rotation band of the ground electronic state of CO. Retrieval of the lines allows a probe of the population distribution of levels J' = 1 through 4 of the excited (v' = 1) vibrational state within the ground electronic state of CO. Knowledge of this distribution can be used to constrain the rotational temperature. Preliminary analysis suggests the P3 line was present UT May 16 at roughly the 5 sigma level. Results concerning the existence of other lines, and physical conditions inferred therefrom are discussed.

Disanti, Michael A.↗

Dynamic-quenching of a single-photon avalanche photodetector using an adaptive resistive switch

One of the most common approaches for quenching single-photon avalanche diodes is to use a passive resistor in series with it. A drawback of this approach has been the limited recovery speed of the single-photon avalanche diodes. High resistance is needed to quench the avalanche, leading to slower recharging of the single-photon avalanche diodes depletion capacitor. We address this issue by replacing a fixed quenching resistor with a bias-dependent adaptive resistive switch. Reversible generation of metallic conduction enables switching between low and high resistance states under unipolar bias. As an example, using a Pt/Al 2 O 3 /Ag resistor with a commercial silicon single-photon avalanche diodes, we demonstrate avalanche pulse widths as small as ~30 ns, 10× smaller than a passively quenched approach, thus significantly improving the single-photon avalanche diodes frequency response. The experimental results are consistent with a model where the adaptive resistor dynamically changes its resistance during discharging and recharging the single-photon avalanche diodes.

42 ENGINEERING↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The exit-wave power-cepstrum transform for scanning nanobeam electron diffraction: robust strain mapping at subnanometer resolution and subpicometer precision

Scanning nanobeam electron diffraction (NBED) with fast pixelated detectors is a valuable technique for rapid, spatially resolved mapping of lattice structure over a wide range of length scales. However, intensity variations caused by dynamical diffraction and sample mistilts can hinder the measurement of diffracted disk centers as necessary for quantification. Robust data processing techniques are needed to provide accurate and precise measurements for complex samples and non-ideal conditions. Here we present an approach to address these challenges using a transform, called the exit wave power cepstrum (EWPC), inspired by cepstral analysis in audio signal processing. The EWPC transforms NBED patterns into real-space patterns with sharp peaks corresponding to inter-atomic spacings. We describe a simple analytical model for interpretation of these patterns that cleanly decouples lattice information from the intensity variations in NBED patterns caused by tilt and thickness. With tracking the inter-atomic spacing peaks in EWPC patterns, strain mapping is demonstrated for two practical applications: mapping of ferroelectric domains in epitaxially strained PbTiO 3 films and mapping of strain profiles in arbitrarily oriented core-shell Pt-Co nanoparticle fuel-cell catalysts. The EWPC transform enables lattice structure measurement at sub-pm precision and sub-nm resolution that is robust to small sample mistilts and random orientations.

42 ENGINEERING↗

Solution epitaxy of polarization-gradient ferroelectric oxide films with colossal photovoltaic current

Solution growth of single-crystal ferroelectric oxide films has long been pursued for the low-cost development of high-performance electronic and optoelectronic devices. However, the established principles of vapor-phase epitaxy cannot be directly applied to solution epitaxy, as the interactions between the substrates and the grown materials in solution are quite different. Here, we report the successful epitaxy of single-domain ferroelectric oxide films on Nb-doped SrTiO 3 single-crystal substrates by solution reaction at a low temperature of ~200 o C. The epitaxy is mainly driven by an electronic polarization screening effect at the interface between the substrates and the as-grown ferroelectric oxide films, which is realized by the electrons from the doped substrates. Atomic-level characterization reveals a nontrivial polarization gradient throughout the films in a long range up to ~500 nm because of a possible structural transition from the monoclinic phase to the tetragonal phase. This polarization gradient generates an extremely high photovoltaic short-circuit current density of ~2.153 mA/cm 2 and open-circuit voltage of ~1.15 V under 375 nm light illumination with power intensity of 500 mW/cm 2 , corresponding to the highest photoresponsivity of ~4.306×10 -3 A/W among all known ferroelectrics. Our results establish a general low-temperature solution route to produce single-crystal gradient films of ferroelectric oxides and thus open the avenue for their broad applications in self-powered photo-detectors, photovoltaic and optoelectronic devices.

36 MATERIALS SCIENCE↗

Avalanche photodiode photon counting receivers for space-borne lidars

Avalanche photodiodes (APD) are studied for uses as photon counting detectors in spaceborne lidars. Non-breakdown APD photon counters, in which the APD's are biased below the breakdown point, are shown to outperform: (1) conventional APD photon counters biased above the breakdown point; (2) conventional APD photon counters biased above the breakdown point; and (3) APD's in analog mode when the received optical signal is extremely weak. Non-breakdown APD photon counters were shown experimentally to achieve an effective photon counting quantum efficiency of 5.0 percent at lambda = 820 nm with a dead time of 15 ns and a dark count rate of 7000/s which agreed with the theoretically predicted values. The interarrival times of the counts followed an exponential distribution and the counting statistics appeared to follow a Poisson distribution with no after pulsing. It is predicted that the effective photon counting quantum efficiency can be improved to 18.7 percent at lambda = 820 nm and 1.46 percent at lambda = 1060 nm with a dead time of a few nanoseconds by using more advanced commercially available electronic components.

Sun, Xiaoli↗

Performance Testing of TRL4-6 LISA Laser System

The Laser Interferometer Space Antenna (LISA) is an ESA-led future mission to measure gravitational waves from astronomical sources in space. LISA has been adopted as a formal mission by ESA in January 2024, and is expected to become a formal project at NASA within 2024. The laser system (LS), which includes four laser heads (LH) each containing a laser optical module (LOM) and laser electronics module (LEM), a frequency reference system (FRS, optical frequency reference) and four power monitor detectors (PMON), is one of the three U.S. contributions to LISA from NASA. The Lasers and Electro-Optics Branch at NASA GSFC has been developing and managing the design of the LISA LS. Currently, the TRL (technology readiness level) of the NASA LISA laser system is transitioning from 4 to 6. TRL 4/5 LISA LOM was sent to ESA in early 2023 and has undergone optical performance testing. [1] By late summer of 2024, NASA plans to deliver the TRL 6 LOM to ESA for performance evaluation. Since the delivery of the TRL4/5 LOM to ESA, we have taken steps to advance the TRL of the overall LS and have also started end-to-end system level testing involving other subsystems. They include 1) optical performance test of TRL6 LOM and TRL 5 LEM under thermal cycling, 2) end-to-end test of the laser head (LH) and the GSE (ground support equipment) FRS, driven by TRL 4 FRS electronics (FRS-E) provided by Ball Aerospace, 3) end-to-end test of the laser head (LH) with the GSE phase meter system (PMS) provided by Albert Einstein Institute, and 4) optical performance test of the LH with the PMON subsystem developed by NASA. The FRS, PMS, and PMON provide necessary frequency stability, relative phase stability between lasers, and output power stability, respectively. Since they are all vital for the sensitive laser interferometry performed in LISA, it is necessary to perform these system level testing by combining the LH and other subsystems, and to prove the optical performance at an early stage during the LS development. Our recent work has successfully demonstrated the intra-connectivity of the LS, as well as critical external interface with the PMS to meet the LISA’s performance requirements. In this talk, we will report on the latest status of the LH testing and system level test. We will also discuss the paths to bring each subsystem to TRL6+ and plans for future system level testing.

LISA↗

A Hot-electron Direct Detector for Radioastronomy

A new approach is proposed to improve the sensitivity of direct-detection bolometers. The idea is to adjust a speed of the thermal relaxation of hot-electrons in a nanometer size normal metal or superconductive transition edge bolometer by controlling the elastic electron mean free path. If the bolometer contacts are made of a superconductor with high critical temperature then the thermal diffusion into the contacts is absent because of the Andreev's reflection and the electron-phonon relaxation is the only mechanism for heat removal. The relaxation rate should behave as 7(exp 4)l at subkelvin temperatures (l is the electron elastic mean free path) and can be reduced by factor of 10 - 100 by decreasing l. Then an antenna- or waveguide-coupled bolometer with a time constant approx. 10(exp -3) to 10(exp -5) S at T approx. = 0.1 - 0.3 K will exhibit photon-noise limited performance in millimeter and subn-millimeter range. The bolometer will have a figure-of-merit NEk square root of tau approx. = 10(exp -22) 10(exp -21) W/Hz at 100 mK which is 10(exp 3) times smaller than that of a state-of-the-art bolometer. This will allow for a tremendous increase in speed which will have a significant impact for observational mapping applications. Alternatively, the bolometer could operate at higher temperature with still superior sensitivity This research was performed by the Center for Space Microelectronics Technology, JPL, California Institute of Technology, under the contract for NASA.

Karasik, B. S.↗

OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. A preliminary estimate of the decay timescale for one detector is that a drop of 0.1-0.2% occurs over a ten day period, indicating that relatively infrequent cal lamp exposures can mitigate the behavior to extremely low levels.

Collins, Nick↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracking 3-D body motion for docking and robot control

An advanced method of tracking three-dimensional motion of bodies has been developed. This system has the potential to dynamically characterize machine and other structural motion, even in the presence of structural flexibility, thus facilitating closed loop structural motion control. The system's operation is based on the concept that the intersection of three planes defines a point. Three rotating planes of laser light, fixed and moving photovoltaic diode targets, and a pipe-lined architecture of analog and digital electronics are used to locate multiple targets whose number is only limited by available computer memory. Data collection rates are a function of the laser scan rotation speed and are currently selectable up to 480 Hz. The tested performance on a preliminary prototype designed for 0.1 in accuracy (for tracking human motion) at a 480 Hz data rate includes a worst case resolution of 0.8 mm (0.03 inches), a repeatability of plus or minus 0.635 mm (plus or minus 0.025 inches), and an absolute accuracy of plus or minus 2.0 mm (plus or minus 0.08 inches) within an eight cubic meter volume with all results applicable at the 95 percent level of confidence along each coordinate region. The full six degrees of freedom of a body can be computed by attaching three or more target detectors to the body of interest.

Donath, M.↗

Heterogeneity of Bulk Oxygen Isotopic Compositions in Anhydrous Interplanetary Dust Particles

Introduction: Anhydrous interplanetary dust particles are one of the least altered ancient solar systemmaterials. Their bulk chemical compositions match those of CI chondrites within a factor of 2-3, except for carbonwhich is enriched in both anhydrous and hydrated IDPs by ~4x CI [1]. Hydrous IDPs often show 16O-poor isotopiccompositions, likely due to the interaction with isotopically heavy H2O [2]. Anhydrous IDPs are interpreted tooriginate from comets from the outer solar system [3]. Oxygen isotopic data for these materials is scarce, but resultspoint to a wider range of compositions [4]. This heterogeneity might be a result of mixing between a 16O-rich and a16O-poor reservoir formed via self-shielding and photodissociation of CO [5]. Here, we report bulk oxygen isotopiccompositions of three anhydrous IDPs in context of their mineralogical composition and discuss possible origins ofisotopic heterogeneity. Experimental: Bulk chemical composition and mineralogy of 70 nm thin ultramicrotomed sections of threeanhydrous IDPs (L2099A7, L2099A8, and L2071AB1) were analyzed using a Thermo Scientific Titan Themis G360-300 TEM equipped with a four-quadrant energy-dispersive X-ray detector (Super-X G2) at University ofMünster. Bulk oxygen isotopic compositions were measured using a NanoSIMS 50 at the Max-Planck-Institut fürChemie in Mainz. A focused Cs+ ion beam (~1 pA, ~100 nm) was rastered over a field of view varying from 5 x 5 to6 x 6 μm2, depending on particle size for 15 layers. Negative secondary ions of 16O, 17O, 18O, 12C14N, and 28Si werecollected on electron multipliers. The 16OH contribution to the 17O peak was 1-2 ‰. As a standard, a matrix regionof meteorite CR2 Queen Alexandra Range (QUE) 99177 was used, whose oxygen isotopic composition wasmeasured by [6]. Results and Discussion: Particles A7 and A8 are both fine-grained, consisting mostly of small, 100 nm-sizedequilibrated aggregates (EA). Both particles exhibit discontinuous magnetite rims with thicknesses up to 50 nm inA7 and 100 nm in A8 on the outsides. In Particle AB1, the upper part of the particle consists of a few EAs, while thelower part contains lots of small GEMS grains with 100-200 nm diameter clustered together. Magnetite rims arenearly absent, the rare rims reaching maximum 20 nm thickness, indicating that AB1 is of more primitive naturethan the other two IDPs [1]. Furthermore, it contains several diffuse GEMS-like areas, identified by an amorphoussilicate groundmass with small nano-inclusions of Fe,Ni-metal and Fe-sulfides. All three particles are subsolar forall major element/Si ratios. Mean S/Si of particles A7 and A8 is 0.046 and 0.048, respectively, while it is an order ofmagnitude higher in AB1 (0.184). This reflects the higher degree of thermal alteration in A7 and A8, resulting in theloss of volatile S and oxidation of Fe-sulfides and FeNi-metal to magnetite as present in particle rims. A8 is rather16O-poor with δ17OSMOW = 7.8 ± 3.4 ‰ and δ18OSMOW = 9.5 ± 3.1 ‰ (1σ), followed by A7 with δ17OSMOW = − 0.8 ±4.6 ‰ and δ18OSMOW = −2.2 ± 3.4 ‰. In contrast to that, AB1 has the most 16O-rich bulk composition with δ17OSMOW= −24.2 ± 5.4 ‰ and δ18OSMOW = −25.3 ± 3.6 ‰. All investigated IDPs plot slightly above the CCAM line aspreviously reported for other anhydrous IDPs [4], maybe due to a contribution from circumstellar dust from AGBstars enriched in 17O [7]. The 16O-rich composition of AB1 is similar to the most 16O-rich anhydrous IDP U2015D21measured by [8] which is dominated by GEMS [9] and the GEMS-rich IDP GM4-2 reported by [10]. Nevertheless,it is unlikely that GEMS are the carrier for the 16O-rich composition of AB1 because most GEMS have O isotopiccompositions indistinguishable from terrestrial values, although errors on these analyses are large [11]. The isotopicheterogeneity is best explained by contribution of grains from different regions in the protoplanetary disk, samplingdifferent O isotope reservoirs, created by self-shielding and photodissociation of CO. This process resulted in 16O-rich CO gas and 16O-poor H2O that froze as ice-mantles onto dust grains [12]. Alternatively, the higher degree ofheating in A7 and A8 could have influenced isotopic fractionation, because higher δ17,18O values are reported fromthe regions of the atmosphere where small particles are heated and oxidized, as observed for the thermal alteration ofcosmic spherules [13]. Acknowledgements: We would like to thank NASA Astromaterials Acquisition & Curation Office for providing IDPsamples and DFG for funding this project (VO1816/5-1)

B Schulz↗

EPR Imaging at a Few Megahertz Using SQUID Detectors

An apparatus being developed for electron paramagnetic resonance (EPR) imaging operates in the resonance-frequency range of about 1 to 2 MHz well below the microwave frequencies used in conventional EPR. Until now, in order to obtain sufficient signal-to-noise radios (SNRs) in conventional EPR, it has been necessary to place both detectors and objects to be imaged inside resonant microwave cavities. EPR imaging has much in common with magnetic resonance imaging (MRI), which is described briefly in the immediately preceding article. In EPR imaging as in MRI, one applies a magnetic pulse to make magnetic moments (in this case, of electrons) precess in an applied magnetic field having a known gradient. The magnetic moments precess at a resonance frequency proportional to the strength of the local magnetic field. One detects the decaying resonance-frequency magnetic- field component associated with the precession. Position is encoded by use of the known relationship between the resonance frequency and the position dependence of the magnetic field. EPR imaging has recently been recognized as an important tool for non-invasive, in vivo imaging of free radicals and reduction/oxidization metabolism. However, for in vivo EPR imaging of humans and large animals, the conventional approach is not suitable because (1) it is difficult to design and construct resonant cavities large enough and having the required shapes; (2) motion, including respiration and heartbeat, can alter the resonance frequency; and (3) most microwave energy is absorbed in the first few centimeters of tissue depth, thereby potentially endangering the subject and making it impossible to obtain adequate signal strength for imaging at greater depth. To obtain greater penetration depth, prevent injury to the subject, and avoid the difficulties associated with resonant cavities, it is necessary to use lower resonance frequencies. An additional advantage of using lower resonance frequencies is that one can use weaker applied magnetic fields: For example, for a resonance frequency of 1.4 MHz, one needs a magnetic flux density of 0.5 Gauss approximately the flux density of the natural magnetic field of the Earth.

Hahn, Inseob↗

Simulation studies related to the particle identification by the forward and backward RICH detectors at Electron Ion Collider

The Electron-Ion collider (EIC) will be the ultimate facility to study the dynamics played by colored quarks and gluons in the phenomenology of nucleons and nuclei, described by Quantum Chromodynamics. The physics programs will greatly rely on efficient particle identification (PID) in both the forward and the backward regions. The forward and the backward RICHes of the EIC have to be able to cover wide acceptance and momentum ranges; in the forward region a dual radiator RICH (dRICH) is foreseen and in the backward region a proximity-focusing RICH can be foreseen to be employed. The geometry and the performance studies of the dRICH have been performed as prescribed in the EIC Yellow Report using the ATHENA software framework. Furthermore, this part of our work reports the effort following the call for EIC detector proposal and the studies related to the forward and the backward RICH performance. In the forward region, the dRICH performance showed a pion- kaon separation from around 1 GeV/c to 50 GeV/c at a three sigma level; the proximity focusing RICH (pfRICH) foreseen for the backward region can reach three sigma separation up to 3 GeV/c for e/$π$ and up to 10 GeV/c for $π$/K mass hypotheses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗