Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “02 - PETROLEUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Crystal structure of M{sub 4}[(UO{sub 2}){sub 2}C{sub 2}O{sub 4}(SO{sub 4}){sub 2}(NCS){sub 2}] (M = K{sup +}, Rh{sup +}) and K{sub 4}[(UO{sub 2}){sub 2}C{sub 2}O{sub 4}(SeO{sub 4}){sub 2}(NCS){sub 2}]

Three heteroacidoligand uranyl complexes M{sub 4}[(UO{sub 2}){sub 2}C{sub 2}O{sub 4}(SO{sub 4}){sub 2}(NCS){sub 2}] (M = K{sup +} (I), Rb{sup +} (II)) and K{sub 4}[(UO{sub 2}){sub 2}C{sub 2}O{sub 4}(SeO{sub 4}){sub 2}(NCS){sub 2}] (III) have been synthesized and their crystal structure has been determined by X-ray diffraction analysis. The compounds I-III are isostructural and crystallized in the monoclinic system, sp. gr. P2{sub 1}/c, Z = 2, a = 11.5548(3) A, b = 7.0847(1) A, c = 13.5172(3) A, {beta} = 93.130(1){sup o}, V = 1104.90(4), R = 0.015 (I); a = 11.5854(9) A, b = 7.3841(6) A, c = 13.9072(9) A, {beta} = 95.754(3){sup o}, V = 1183.74(15), R = 0.0235 (II); a = 11.6715(3) A, b = 7.1418(2) A, c = 13.8546(1) A, {beta} = 93.539(1){sup o}, V = 1152.66(5), R = 0.0126 (III). Basic structural units of these crystals are [(UO{sub 2}){sub 2}C{sub 2}O{sub 4}(XO{sub 4}){sub 2}(NCS){sub 2}]{sup 4-} chains, which belong to the crystallochemical group A{sub 2}K{sup 02}B{sub 2}{sup 2}M{sub 2}{sup 1} (A = UO{sub 2}{sup 2+}, K{sup 02} = C{sub 2}O{sub 2-}{sup 4}, B{sup 2} = SO{sub 4}{sup 2-} or SeO{sub 4}{sup 2-}, M{sup 1} = NCS{sup -}) of uranyl complexes. Uranium-containing chains are connected into a 3D framework via a system of electrostatic interactions with potassium or rubidium cations from outer spheres.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis and structure of {l_brace}NH{sub 2}(C{sub 2}H{sub 5}){sub 2}{r_brace}{sub 2}[(UO{sub 2}){sub 2}(C{sub 2}O{sub 4})(CH{sub 3}COO){sub 4}] . 2H{sub 2}O

Single crystals of the compound {l_brace}NH{sub 2}(C{sub 2}H{sub 5}){sub 2}{r_brace}{sub 2}[(UO{sub 2}){sub 2}C{sub 2}O{sub 4}(CH{sub 3}COO){sub 4}] . 2H{sub 2}O (I) are synthesized, and their structure is investigated using X-ray diffraction. Compound I crystallizes in the monoclinic system with the unit cell parameters a = 9.210(2) A, b = 14.321(3) A, c = 12.659(3) A, {beta} = 105.465(13){sup o}, V = 1609.2(6) A{sup 3}, space group P2{sub 1}/c, Z = 2, and R = 0.0198. The structural units of crystals I are binuclear groups of the composition [(UO{sub 2}){sub 2}C{sub 2}O{sub 4}(CH{sub 3}COO){sub 4}]{sup 2-} with an island structure, which belong to the crystal-chemical group A{sub 2}K{sup 02}B{sub 4}{sup 01} (A = UO{sub 2}{sup 2+}, K{sup 02} = C{sub 2}O{sub 4}{sup 2-}, B{sup 01} = CH{sub 3}COO{sup -}) of the uranyl complexes, diethylammonium cations, and water molecules. The uranium-containing groups are joined into a three-dimensional framework through electrostatic interactions with diethylammonium cations and a system of hydrogen bonds, which are formed with the participation of the atoms involved in the composition of the water molecules, oxalate ions, acetate ions, and diethylammonium cations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis and structure of K{sub 2}[(UO{sub 2}){sub 4}(O){sub 2}(OH){sub 2}(C{sub 2}O{sub 4})(CH{sub 3}COO){sub 2}(H{sub 2}O){sub 2}].2H{sub 2}O

Single crystals of the compound K{sub 2}[(UO{sub 2}){sub 4}(O){sub 2}(OH){sub 2}(C{sub 2}O{sub 4})(CH{sub 3}COO){sub 2}(H{sub 2}O){sub 2}].2H{sub 2}O (I) are synthesized, and their structure is investigated using X-ray diffraction. Crystals of compound I belong to the triclinic system with the unit cell parameters a = 7.6777(6) A, b = 7.9149(7) A, c = 10.8729(9) A, {alpha} = 72.379(2){sup o}, {beta} = 86.430(3){sup o}, {gamma} = 87.635(2){sup o}, V = 628.33(9) A{sup 3}, space group P1-bar, Z = 1, and R{sub 1} = 0.0323. The main structural units of the crystals are [(UO{sub 2}){sub 4}(O){sub 2}(OH){sub 2}(C{sub 2}O{sub 4})(CH{sub 3}COO){sub 2}(H{sub 2}O){sub 2}]{sup 2-} chains, which belong to the crystal-chemical group A{sub 4}M{sub 2}{sup 3}M{sub 2}{sup 2}K{sup 02}B{sub 2}{sup 01}M{sub 2}{sup 1} (A = UO{sub 2}{sup 2+}, M{sup 3} = O{sup 2-}, M{sup 2} = OH{sup -}, K{sup 02} = C{sub 2}O{sub 4}{sup 2-}, B{sup 01} = CH{sub 3}COO{sup -}, M{sup 1} = H{sub 2}O) of the uranyl complexes. The chains are formed by linking the centrosymmetric tetramers of the composition (UO{sub 2}){sub 4}(O){sub 2}(OH){sub 2}(CH{sub 3}COO){sub 2}(H{sub 2}O){sub 2} via tetradentate bridging oxalate ions. The uranium-containing groups are joined into a three-dimensional framework through the electrostatic interaction with potassium cations and a system of hydrogen bonds, which are formed with the participation of atoms involved in the composition of the water molecules, hydroxide ions, and uranyl ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis and an X-ray diffraction study of Rb{sub 2}[(UO{sub 2}){sub 2}(C{sub 2}O{sub 4}){sub 3}]

The synthesis and X-ray diffraction study of compound Rb{sub 2}[(UO{sub 2}){sub 2}(C{sub 2}O{sub 4}){sub 3}], which crystallizes in the monoclinic crystal system, are performed. The unit cell parameters are as follows: a = 7.9996(6) A, b = 8.8259(8) A, c = 11.3220(7) A, {beta} = 105.394(2){sup o}, and V = 770.7(1) A{sup 3}; space group P2{sub 1}/n, Z = 2, and R{sub 1} = 0.0271. [(UO{sub 2}){sub 2}(C{sub 2}O{sub 4}){sub 3}]{sup 2-} layers belonging to the AK{sub 0.5}{sup 02}T{sup 11} crystal chemical group of uranyl complexes (A = UO{sub 2}{sup 2+}, K{sup 02} = C{sub 2}O{sub 4}{sup 2-}, and T{sup 11} = C{sub 2}O{sub 4}{sup 2-}) are uranium-containing structural units of the crystals. The layers are connected with outer-sphere rubidium cations by electrostatic interactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crystal structure and IR spectroscopic study of (CN{sub 3}H{sub 6}){sub 2}[(UO{sub 2}){sub 2}(C{sub 2}O{sub 4})(CH{sub 3}COO){sub 4}]

Compound (CN{sub 3}H{sub 6}){sub 2}[(UO{sub 2}){sub 2}(C{sub 2}O{sub 4})(CH{sub 3}COO){sub 4}] is synthesized and characterized by IR spectroscopy and single-crystal X-ray diffraction [a = 8.5264(2) A, b = 13.8438(4) A, c = 10.7284(2) A, {beta} = 103.543(1) Degree-Sign , space group P2{sub 1}/n, Z = 2, and R = 0.0258]. The main structural units of the crystals are binuclear [(UO{sub 2}){sub 2}C{sub 2}O{sub 4}(CH{sub 3}COO){sub 4}]{sup 2-} groups, which belong to the A{sub 2}K{sup 02}B{sub 4}{sup 01} crystal chemical group of uranyl complexes (A = UO{sub 2}{sup 2+}, K{sup 02} = C{sub 2}O{sub 4}{sup 2-}, and B{sup 01} = CH{sub 3}COO{sup -}). The coordination polyhedron of the uranium atom is the UO{sub 8} hexagonal bipyramid with the oxygen atoms of the uranyl ion at the axial positions. Uranium-containing groups and guanidinium cations are connected by electrostatic interactions and by the hydrogen bond system, which involves hydrogen atoms of guanidinium cations and oxygen atoms of oxalate and acetate anions. The results of the spectroscopic study of the compound agree with the X-ray diffraction data.

36 MATERIALS SCIENCE↗

Effect of irradiation with gamma-ray photons on the charge-transport mechanism in n-CdS/p-CdTe heterostructures

Effect of irradiation with {gamma}-ray photons on the mechanism of charge transport in an n-CdS/p-CdTe heterostructure is considered. It is shown that the forward current-voltage characteristic of an n-CdS/p-CdTe heterostructure before and after irradiation is described by two exponential dependences: I = I{sub 01}exp(qV/C{sub 01}kT) and I = I{sub 02}exp(qV/C{sub 02}kT). It is found that, in the first portion of the current-voltage characteristic, the current is limited by thermoelectronic emission while, in the second portion, the current is limited by recombination of nonequilibrium charge carriers in the electrically neutral portion of a CdTe{sub 1-x}S{sub x} alloy at the n-CdS/p-CdTe heteroboundary. Anomalous dose dependences of parameters of the n-CdS/p-CdTe heterosystem are attributed to a variation in the degree of compensation of local centers at the CdS-CdTe{sub 1-x}S{sub x} interface and in the CdTe{sub 1-x}S{sub x} layers in relation to the dose of irradiation with {gamma}-ray photons.

36 MATERIALS SCIENCE↗

Cycle-to-cycle variability in spark-assisted compression ignition engines near optimal mean combustion phasing

Stoichiometric spark-assisted compression ignition (SACI) combustion with exhaust gas recirculation (EGR) dilution has demonstrated higher part-load thermal efficiencies compared to spark-ignited engines, while maintaining ultra-low tailpipe emissions. However, SACI is often characterized by high cyclic variability in heat release or torque output, which poses a challenge to its implementation in light-duty vehicles. This paper presents an experimental investigation of cyclic variability in stoichiometric SACI combustion under EGR-dilute conditions, while maintaining mean combustion phasing (θ 50 ) near optimal timing for thermal efficiency. The present work focuses on SACI conditions where the flame-based heat release fraction is between approximately 10% and 40% of the overall heat release, and therefore contributes significantly to the combustion process. For the SACI conditions examined, the variability in θ 50 was driven by variability in autoignition timing, which in turn correlated with the start of measurable heat release (θ 02 ). High variability in θ 50 caused unstable work output due to very late combustion with poor or no end-gas autoignition. The use of a high ignition energy dual-coil offset ignition system had negligible impact in reducing θ 50 variability. Analysis of experimental data from close to 1000 operating conditions showed that the magnitude of θ 50 variability correlates with the flame-based heat release fraction ([Formula: see text]), for a large range of intake pressures, spark timings and exhaust gas recirculation levels. For the SACI conditions examined, combustion phasing variability was largely determined by flame-based combustion and particularly the initial flame formation (θ IGN-02 ), and minimally by the end-gas autoignition heat release. The analysis also demonstrated that θ 50 variability is amplified as the contribution of the flame to the overall heat release increases.

Engineering↗

A bespoke model of Arctic river basins based on hillslope delineation: Model Archive

This dataset is a model archive of the paper A bespoke model of Arctic river basins based on hillslope delineation (in prep), which introduces a watershed decomposition and parameterization method for large scale permafrost hydrology simulation. With this dataset, this study aims to address the research question: whether a computationally efficient hillslope-based modeling framework can reliably simulate discharge at Arctic river-basin scales. This dataset contains model input and output data for five modeling scenarios at a study site located in the Sagavanirktok River basin. The five modeling scenarios include three modeling cases under temperate conditions using full 3D, decomposed 3D, and decomposed 2D modeling strategies; and two modeling cases under actual Arctic conditions with permafrost using full 3D and decomposed 2D modeling strategies. Simulations were performed using the Advanced Terrestrial Simulator (ATS, v1.6 for three temperate scenarios and v1.5 for two Arctic scenarios), a physics-rich integrated surface–subsurface hydrologic model with cryo-hydrology features. For the three temperate models, simulations were conducted for the period of 10/01/1993 - 09/30/2002; and for the two Arctic models, simulations were conducted for the period of 01/01/1994 - 12/31/2002. To facilitate reproducibility of simulations, all datasets are organized hierarchically. The dataset contains: (1) Mesh files (.exo) for full 3D model, decomposed 3D models, and decomposed 2D models, located in huc/190604020802_gauge15906000/mesh/. Mesh files can be visualized through Paraview or read by Python. (2) Climate forcings (.h5) for full 3D model and decomposed 3D/2D models are located in huc/190604020802_gauge15906000/daymet_onePiece/, and huc/190604020802_gauge15906000/vp_pr_revised_daymet_1980_2006_with_wind/ separately. Accessible by Python. (3) Raw measured gage discharge (.csv) from USGS, located in huc/190604020802_gauge15906000/gaged_basin15906000_discharge_usgs/. Accessible by Python. (4) Delineated subdomain raster (.tif) and shape files (.shp), and the final parameterized results (.npy) for decomposed models, located in huc/190604020802_gauge15906000/data_preprocessed-meshing. Accessible by Python. (5) Temperate models are located in nonpermaf_huc190604020802_gauge15906000/, which includes three cases: decomposed 2D models (inside model_0*-hillslope_*), decomposed 3D models (inside model_1*-subcatchment_*), and full 3D model (inside model_2*-onepiece_*). Two step spin-up results (checkpoint_final.h5) are located in model_*1-*_spinup_steadystate and model_*2-*_spinup_cycle, separately, which are used to initialize real transient models. The input files (.xml) and output results (.dat) of the real transient models are located in model_*3-*_transient/. Especially, for two example hillslope models (ID=-11 and 11), additional h5py files are included in model_03-hillslope_transient/hillslope-11/, model_03-hillslope_transient/hillslope11, model_13-subcatchment_transient/subcatchment-11/, model_13-subcatchment_transient/subcatchment/11, respectively, which are used to plot the saturation figure (Figure 5) in the manuscript. Accessible by Python. (6) Arctic models are located in huc190604020802_gauge15906000/, which includes two cases: decomposed 2D models (inside model_04-hillslope_transient), and full 3D model (inside model_05-onepiece_transient_mannp1_ra). Three step spin-up results (checkpoint_final.h5) are located in model_01-column_freezeup/, model_02-column_spinup/, model_03-hillslope_spinup/, respectively, which are used to initialize real 2D transient hillslope models. The input files (.xml) and output results (.dat) of transient 2D hillslope models are located in model_04-hillslope_transient/. The input files (.xml) and output results (.dat) of the full 3D transient model is located in model_05-onepiece_transient_mannp1_ra/. The full 3D transient model is initialized by model_02-column_spinup/. Accessible by Python. (7) The MOSART routed discharge results (.csv) under Arctic conditions is located in huc190604020802_gauge15906000/MOSART/. Accessible by Python. (8) All Python codes (.py) used to parameterize full 3D model to decomposed 2D models are located in script/. These codes fit with watershed workflow (a watershed delineation tool) v1.4 under the branch gaob/v1.4 from https://github.com/gaobhub/watershed-workflow.git.

EARTH SCIENCE > CRYOSPHERE↗

Closure Report for Corrective Action Unit 544: Cellars, Mud Pits, and Oil Spills, Nevada National Security Site, Nevada, Revision 0 with ROTC 1

This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 544: Cellars, Mud Pits, and Oil Spills, Nevada National Security Site, Nevada. This CR complies with the requirements of the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. The corrective action sites (CASs) within CAU 544 are located within Areas 2, 7, 9, 10, 12, 19, and 20 of the Nevada National Security Site. Corrective Action Unit 544 comprises the following CASs: • 02-37-08, Cellar & Mud Pit • 02-37-09, Cellar & Mud Pit • 07-09-01, Mud Pit • 09-09-46, U-9itsx20 PS #1A Mud Pit • 10-09-01, Mud Pit • 12-09-03, Mud Pit • 19-09-01, Mud Pits (2) • 19-09-03, Mud Pit • 19-09-04, Mud Pit • 19-25-01, Oil Spill • 19-99-06, Waste Spill • 20-09-01, Mud Pits (2) • 20-09-02, Mud Pit • 20-09-03, Mud Pit • 20-09-04, Mud Pits (2) • 20-09-06, Mud Pit • 20-09-07, Mud Pit • 20-09-10, Mud Pit • 20-25-04, Oil Spills • 20-25-05, Oil Spills The purpose of this CR is to provide documentation supporting the completed corrective actions and data confirming that the closure objectives for CASs within CAU 544 were met. To achieve this, the following actions were performed: • Review the current site conditions, including the concentration and extent of contamination. • Implement any corrective actions necessary to protect human health and the environment. • Properly dispose of corrective action and investigation wastes. • Document Notice of Completion and closure of CAU 544 issued by the Nevada Division of Environmental Protection.

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 547: Miscellaneous Contaminated Waste Sites, Nevada National Security Site, Nevada, Revision 0

The purpose of this CADD/CAP is to present the corrective action alternatives (CAAs) evaluated for CAU 547, provide justification for selection of the recommended alternative, and describe the plan for implementing the selected alternative. Corrective Action Unit 547 consists of the following three corrective action sites (CASs): (1) CAS 02-37-02, Gas Sampling Assembly; (2) CAS 03-99-19, Gas Sampling Assembly; and(3) CAS 09-99-06, Gas Sampling Assembly. The gas sampling assemblies consist of inactive process piping, equipment, and instrumentation that were left in place after completion of underground safety experiments. The purpose of these safety experiments was to confirm that a nuclear explosion would not occur in the case of an accidental detonation of the high-explosive component of the device. The gas sampling assemblies allowed for the direct sampling of the gases and particulates produced by the safety experiments. Corrective Action Site 02-37-02 is located in Area 2 of the Nevada National Security Site (NNSS) and is associated with the Mullet safety experiment conducted in emplacement borehole U2ag on October 17, 1963. Corrective Action Site 03-99-19 is located in Area 3 of the NNSS and is associated with the Tejon safety experiment conducted in emplacement borehole U3cg on May 17, 1963. Corrective Action Site 09-99-06 is located in Area 9 of the NNSS and is associated with the Player safety experiment conducted in emplacement borehole U9cc on August 27, 1964. The CAU 547 CASs were investigated in accordance with the data quality objectives (DQOs) developed by representatives of the Nevada Division of Environmental Protection (NDEP) and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for CAU 547. Existing radiological survey data and historical knowledge of the CASs were sufficient to meet the DQOs and evaluate CAAs without additional investigation. As a result, further investigation of the CAU 547 CASs was not required. The following CAAs were identified for the gas sampling assemblies: (1) clean closure, (2) closure in place, (3) modified closure in place, (4) no further action (with administrative controls), and (5) no further action. Based on the CAAs evaluation, the recommended corrective action for the three CASs in CAU 547 is closure in place. This corrective action will involve construction of a soil cover on top of the gas sampling assembly components and establishment of use restrictions at each site. The closure in place alternative was selected as the best and most appropriate corrective action for the CASs at CAU 547 based on the following factors: (1) Provides long-term protection of human health and the environment; (2) Minimizes short-term risk to site workers in implementing corrective action; (3) Is easily implemented using existing technology; (4) Complies with regulatory requirements; (5) Fulfills FFACO requirements for site closure; (6) Does not generate transuranic waste requiring offsite disposal; (7) Is consistent with anticipated future land use of the areas (i.e., testing and support activities); and (8) Is consistent with other NNSS site closures where contamination was left in place.

54 ENVIRONMENTAL SCIENCES↗

Laser Cladding Applied to the Construction of PFC's with Integral Tritium Diffusion Barriers (Final Report)

This report summarizes progress during the performance period of 02 February 2013 through 02 December 2013 for contract number DE-SC0009685. During this period Nanohmics Inc., in partnership with Dr. Y. C. Shin of Purdue Universities’ Mechanical Engineering Department, have successfully developed a design and a process for constructing PFC tiles suitable for incorporation in fusion reactors. The tiles consist of an ODS steel substrate with tungsten cladding, an integral SiC tritium diffusion barrier layer and a top cap of tungsten. The close match of the coefficient of linear expansion (CTE) between the tungsten and the SiC layer allow high temperature operation without layer delamination of cracking. Furthermore, similar samples constructed by Nanohmics were tested at MIT’s Plasma Science Fusion Center and demonstrated the SiC layer to be an excellent barrier for hydrogen isotope diffusion. The cladding process for applying tungsten to the ODS substrate is unique and provides a quick means of joining complex ODS structures to tungsten layers.

Laser Cladding Applied to the Construction of PFC'↗

CPAP Ventilators Needed for Rapid Response to COVID-19 by Modification of CPAP Equipment

Early on in the COVID-19 pandemic, potential ventilator shortages were a critical issue identified by national health care providers. Capacity modeling at the time suggested patient demand may exceed ventilator supply. Thus, the challenge became finding an urgent interim solution to meet health care needs. Our initial hypothesis was that CPAP technology could be modified to provide similar functionality to a ventilator, relieving demand and allowing physicians to decide which patients need high end machines, ultimately saving lives. In conjunction with medical experts and pulmonologists, we were able to identify three key thrusts associated with this research problem: (1) modification of CPAP technology to allow for 02 input that would be capable of providing ventilation; (2) development of an alarming function that would provide real-time audible alarms to alert medical personnel to critical conditions, which would be used inline with CPAP technology; and (3) a method of sterilizing expiratory air from such a system in order to protect medical personnel from biohazard, since CPAPs vent to the atmosphere. We were unable to realize results for thrust 1 (CPAP modification for 02); we identified potential safety issues associated with utilizing medical grade oxygen with a common CPAP device. In order to characterize and mitigate these issues, we would need to partner closely with a device manufacturer; such a partnership could not be achieved in the timeframe needed for this rapid response work. However, we determined that some medical grade BiPAP devices do not need this modification and that the significant progress on thrusts 2 and 3 would be sufficient to buy down risk of a massive ventilator shortage. Our team built a prototype alarm system that can be utilized with any assistive respiratory device to alert on all key conditions identified by medical personnel (high pressure, low pressure, apnea, loss of power, low battery). Finally, our team made significant progress in the rapid prototyping and demonstration of an inline UV air purifier device. The device is cost efficient and can be manufactured at scale with both commercially available and additively manufactured parts. Initial tests with SARS-CoV-2 analog bacteriophage MS2 show 99% efficacy at reducing bioburden. Following a successful demonstration of the prototype device with medical personnel, we were able to obtain follow-on (non-LDRD) funding to provide additional device characterization, validation, and production in order to respond to an immediate regional need.

42 ENGINEERING↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 578: Miscellaneous Inactive Sites Nevada National Security Site, Nevada, (Rev. 0)

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 578, Miscellaneous Inactive Sites, identified in the Federal Facility Agreement and Consent Order (FFACO). CAU 578 comprises the following 11 corrective action sites (CASs) located in Areas 2, 3, 4, 6, 7, 12, and 23 of the Nevada National Security Site: • 02-26-01, Lead (Concrete Box w/Lining) • 02-26-07, Gun Turret w/Lead in Barrel • 03-16-01, U-3auS Disposal Site • 04-26-02, Lead on Instrument Bunker • 06-99-07, Sump • 07-99-01, Miscellaneous Debris • 12-02-11, UST-P-2 • 12-06-01, Muckpile • 12-06-04, Muckpile • 23-12-01, Boiler (2) • 23-99-04, Salvage Yard This plan provides the methodology for field activities needed to gather the necessary information for closing each CAS. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 578 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible recommendation that no further corrective action is necessary. This will be presented in a closure report that will be prepared and submitted to the Nevada Division of Environmental Protection (NDEP) for review and approval.

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Decision Document/Closure Report for Corrective Action Unit 545: Dumps, Waste Disposal Sites, and Buried Radioactive Materials Nevada Test Site, Nevada, Revision 0, with ROTC 1

This Corrective Action Decision Document (CADD)/Closure Report (CR) has been prepared for Corrective Action Unit (CAU) 545, Dumps, Waste Disposal Sites, and Buried Radioactive Materials, in Areas 2, 3, 9, and 20 of the Nevada Test Site, Nevada, in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management (1996, as amended February 2008). Corrective Action Unit 545 is comprised of the following eight Corrective Action Sites (CASs): • 02-09-01, Mud Disposal Area • 03-08-03, Mud Disposal Site • 03-17-01, Waste Consolidation Site 3B • 03-23-02, Waste Disposal Site • 03-23-05, Europium Disposal Site • 03-99-14, Radioactive Material Disposal Area • 09-23-02, U-9y Drilling Mud Disposal Crater • 20-19-01, Waste Disposal Site While all eight CASs are addressed in this CADD/CR, sufficient information was available for the following three CASs; therefore, a field investigation was not conducted at these sites: • For CAS 03-08-03, though the potential for subsidence of the craters was judged to be extremely unlikely, the data quality objective (DQO) meeting participants agreed that sufficient information existed about disposal and releases at the site and that a corrective action of close in place with a use restriction is recommended. Sampling in the craters was not considered necessary. • For CAS 03-23-02, there were no potential releases of hazardous or radioactive contaminants identified. Therefore, the Corrective Action Investigation Plan for CAU 545 concluded that: “Sufficient information exists to conclude that this CAS does not exist as originally identified. Therefore, there is no environmental concern associated with CAS 03-23-02.” This CAS is closed with no further action. • For CAS 03-23-05, existing information about the two buried sources and lead pig was considered to be sufficient, and safety concerns existed about the stability of the crater component. Therefore, a corrective action of close in place with a use restriction is recommended, and sampling at the site was not considered necessary. The purpose of this CADD/CR is to provide justification and documentation to support the recommendation for closure of CAU 545 with no further corrective action. To achieve this, corrective action investigation (CAI) activities were performed from August 20 through November 02, 2007, as set forth in the CAU 545 Corrective Action Investigation Plan. The purpose of the CAI was to fulfill the following data needs as defined during the DQO process: • Determine whether contaminants of concern (COCs) are present. • If COCs are present, determine their nature and extent. • Provide sufficient information and data to complete appropriate corrective actions. The CAU 545 dataset from the investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the quality and acceptability of the dataset for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against final action levels established in this CADD/CR. The results of the CAI identified no COCs at the five CASs investigated in CAU 545. As a best management practice, repair of the fence enclosing CAS 03-08-03 has been completed. Therefore, the DOE, National Nuclear Security Administration Nevada Site Office provides the following recommendations: • Close in place COCs at CASs 03-08-03 and 03-23-05 with use restrictions. • No further corrective action for CAU 545. • No Corrective Action Plan. • Corrective Action Unit 545 should be moved from Appendix III to Appendix IV of the Federal Facility Agreement and Consent Order. • A Notice of Completion to the DOE, National Nuclear Security Administration Nevada Site Office is requested from the Nevada Division of Environmental Protection for closure of CAU 545.

54 ENVIRONMENTAL SCIENCES↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 544: Cellars, Mud Pits, and Oil Spills, Nevada Test Site, Nevada, Revision 0

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 544, Cellars, Mud Pits, and Oil Spills, identified in the Federal Facility Agreement and Consent Order (FFACO). Corrective Action Unit 544 comprises the following 20 corrective action sites (CASs) located in Areas 2, 7, 9, 10, 12, 19, and 20 of the Nevada Test Site (NTS): • 02-37-08, Cellar & Mud Pit • 02-37-09, Cellar & Mud Pit • 07-09-01, Mud Pit • 09-09-46, U-9itsx20 PS #1A Mud Pit • 10-09-01, Mud Pit • 12-09-03, Mud Pit • 19-09-01, Mud Pits (2) • 19-09-03, Mud Pit • 19-09-04, Mud Pit • 19-25-01, Oil Spill • 19-99-06, Waste Spill • 20-09-01, Mud Pits (2) • 20-09-02, Mud Pit • 20-09-03, Mud Pit • 20-09-04, Mud Pits (2) • 20-09-06, Mud Pit • 20-09-07, Mud Pit • 20-09-10, Mud Pit • 20-25-04, Oil Spills • 20-25-05, Oil Spills This plan provides the methodology for field activities needed to gather the necessary information for closing each CAS. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 544 using the SAFER process. Using the approach approved for previous mud pit investigations (CAUs 530–535), 14 mud pits have been identified that • are either a single mud pit or a system of mud pits, • are not located in a radiologically posted area, and • have no evident biasing factors based on visual inspections. These 14 mud pits are recommended for no further action (NFA), and further field investigations will not be conducted. For the sites that do not meet the previously approved closure criteria, additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible recommendation for closure of the remaining CASs in CAU 544. This will be presented in a closure report (CR) that will be prepared and submitted to the Nevada Division of Environmental Protection (NDEP) for review and approval. The sites will be investigated based on the data quality objectives (DQOs) developed on April 27, 2010, by representatives of NDEP and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO). The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for each CAS in CAU 544. The DQO process developed for this CAU identified the following expected closure options: (1) investigation and confirmation that no contamination exists above the final action levels (FALs) leading to an NFA declaration, (2) characterization of the nature and extent of contamination leading to closure in place with use restrictions, (3) clean closure by remediation and verification, (4) closure in place with use restrictions with no investigation if CASs are in crater areas that have been determined to be unsafe to enter, or (5) NFA if the mud pit CAS meets the criteria established during the CAUs 530–535 SAFER investigation. The following summarizes the SAFER activities that will support the closure of CAU 544: • Perform visual inspection of all CASs. • Perform site preparation activities (e.g., utilities clearances, construction of temporary site exclusion zones). • Removal of easily managed, nonhazardous, and nonradioactive debris, including vegetation (e.g., tumbleweeds), at various CASs that interfere with sampling, if required to inspect soil surface or collect soil sample. • Collect environmental samples from designated target populations (e.g., mud pits, cellars, stained soil) to confirm or disprove the presence of contaminants of concern (COCs) as necessary to supplement existing information. • If no COCs are present at a CAS, establish NFA as the corrective action. • If COCs exist, collect environmental samples from designated target populations (e.g., clean soil adjacent to contaminated soil) and submit for laboratory analyses to define the extent of COC contamination. • If a COC is present at a CAS, either - Establish clean closure as the corrective action. The material to be remediated will be removed, disposed of as waste, and verification samples will be collected from remaining soil, or - Establish closure in place as the corrective action and implement the appropriate use restrictions. • Confirm the preferred closure option is sufficient to protect human health and the environment.

01 COAL, LIGNITE, AND PEAT↗

OBSERVATION OF MAGNETIC RECONNECTION AT A 3D NULL POINT ASSOCIATED WITH A SOLAR ERUPTION

Magnetic null has long been recognized as a special structure serving as a preferential site for magnetic reconnection (MR). However, the direct observational study of MR at null-points is largely lacking. Here, we show the observations of MR around a magnetic null associated with an eruption that resulted in an M1.7 flare and a coronal mass ejection. The Geostationary Operational Environmental Satellites X-ray profile of the flare exhibited two peaks at ∼02:23 UT and ∼02:40 UT on 2012 November 8, respectively. Based on the imaging observations, we find that the first and also primary X-ray peak was originated from MR in the current sheet (CS) underneath the erupting magnetic flux rope (MFR). On the other hand, the second and also weaker X-ray peak was caused by MR around a null point located above the pre-eruption MFR. The interaction of the null point and the erupting MFR can be described as a two-step process. During the first step, the erupting and fast expanding MFR passed through the null point, resulting in a significant displacement of the magnetic field surrounding the null. During the second step, the displaced magnetic field started to move back, resulting in a converging inflow and subsequently the MR around the null. The null-point reconnection is a different process from the current sheet reconnection in this flare; the latter is the cause of the main peak of the flare, while the former is the cause of the secondary peak of the flare and the conspicuous high-lying cusp structure.

79 ASTRONOMY AND ASTROPHYSICS↗

COMBLE-ISLAS water isotopes in precipitation (COMBLEISLASISO)

During the measurement period, precipitation was sampled on daily to sub-daily basis with a sampling kit consiting of a clear plastic box (60x40x40 cm) mounted to a ground structure. Daily sampling lasted from 22 Feb to 24 Mar 2020. At a fixed time of day (10 UTC), samples were collected and the sampling box cleaned for the next sample. Additionally, during intense observations periods (IOPs) announced by ISLAS, ARMS scientists increased sampling frequency to sub-daily sampling. During the campaign period, 2 IOPs were conducted, with in total 12 samples taken. IOP1 lasted from 27 Feb 10 to 02 Mar 2020, and IOP2 lasted from 12 Mar to 14 Mar 2020. Solid precipitation in the box was then melted, transferred to an 8 ml glass vial, sealed and shipped to FARLAB (University of Bergen, Norway) for stable water isotope analysis. Measured stable isotope composition of precipitation samples will be related to conditions at other sampling locations, and at the evaporation site to inform about conservation of water isotope quantities. In the period from 22 Feb to 24 Mar, 23 daily samples were collected at 10 UTC for stable water isotope analysis. During the entire sampling period, a high variability of precipitation phase was encountered. Most samples were recovered in the form of graupel/snow (12 samples), as rain (7 samples), and the remaining samples fell as graupel, snow, rain or frozen rain. Precipitation amounts varied between <1 mm (26 Feb) and 140 mm (25 Feb) within the sampling box. Furthermore, higher-resolution sampling was conducted during 2 intense observation periods (IOPs). During IOP1, lasting from 27 Feb 10 UTC to 02 Mar 10 UTC, 7 samples were collected, all of them as solid phase precipitation. IOP2 lasted from 12 Mar 10 UTC to 14 Mar 09 UTC, and 5 samples (all as graupel/snow) were collected. Samples were processed according to FARLAB standard measurement procedures. In short, samples were transferred to 1.5 ml glass vials with rubber/PTFE septa (part #548-0907, VWR, USA). An autosampler (A0325, Picarro Inc) transferred ca. 2&micro;l per injection into a high-precision vapourizer (A0211, Picarro Inc, USA) heated to 110&deg;C. After blending with dry N2 (< 5 ppm H2O) the gas mixture was directed into the measurement cavity of a Cavity-Ring Down Spectrometer (L2140-i, Picarro Inc) for about 7 min with a typical water concentration of 20 000 ppm. Memory effects were reduced by two times measuring a vapour mixture at a mixing ratio of 50 000 ppm, obtained from 2 injections of 2 &micro;l for 5 min at the beginning of each new sample vial. Thereafter, another 6 injections of 2 &micro;l per sample were measured individually as described above, and averages of the last 5 injections were used for further processing. Three standards were measured at the beginning and end of each batch, including a drift standard DI2 (&delta;D: -50.72&plusmn;0.73 permil, &delta;18O: -7.63&plusmn;0.10 permil), and for calibration the laboratory standards GLW (&delta;D: -307.79&plusmn;0.75 permil, &delta;18O: -40.02&plusmn;0.07 permil) and EVAP2 (&delta;D: 9.52&plusmn;0.65 permil, &delta;18O: 1.81&plusmn;0.13 permil). A detailed calibration report is included with the final uploaded data set.

54 ENVIRONMENTAL SCIENCES↗

Development and pilot line production of lithium doped silicon solar cells

The work performed over the period of September 1971 to August 1972 to develop production processes for fabrication of lithium doped P/N cells is described. The BCl3 diffusion without 02 was selected as the optimum diffusion process for fabrication of lithium doped cells. An 8-2-7 (warm up - deposition - drive-in time in minutes) diffusion schedule at 1055 C was used for the first two lots (300 cells each) delivered to JPL. Cell efficiencies ranged from 11.0 to 13.7% based on an AMO of 135.3 mW/sq cm. These high efficiencies were obtained using from 10 to 40 cells per boron diffusion; increasing the quantity beyond 40 resulted in lower outputs. At this point, the emphasis was placed on investigation of a BCl3 with 02 diffusion. Through evaluation of the effects of diffusion time and temperature, gas flow rates, and desposition plus drive-in vs. continuous deposition and no drive-in cycles, diffusion parameters were determined which produced short circuit currents of 136 + or - 4 mA for ten cells spaced along 12 in. of the diffusion boat. The quantity was increased to 60, 100, and 150 cell diffusions with no more variation in cell short circuit current than observed with 10 cells.

Payne, P. A.↗