Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage prediction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

AI-Enabled Operations at Fermi Complex: Multivariate Time Series Prediction for Outage Prediction and Diagnosis

The Main Control Room of the Fermilab accelerator complex continuously gathers extensive time-series data from thousands of sensors monitoring the beam. However, unplanned events such as trips or voltage fluctuations often result in beam outages, causing operational downtime. This downtime not only consumes operator effort in diagnosing and addressing the issue but also leads to unnecessary energy consumption by idle machines awaiting beam restoration. The current threshold-based alarm system is reactive and faces challenges including frequent false alarms and inconsistent outage-cause labeling. To address these limitations, we propose an AI-enabled framework that leverages predictive analytics and automated labeling. Using data from $2,703$ Linac devices and $80$ operator-labeled outages, we evaluate state-of-the-art deep learning architectures, including recurrent, attention-based, and linear models, for beam outage prediction. Additionally, we assess a Random Forest-based labeling system for providing consistent, confidence-scored outage annotations. Our findings highlight the strengths and weaknesses of these architectures for beam outage prediction and identify critical gaps that must be addressed to fully harness AI for transitioning downtime handling from reactive to predictive, ultimately reducing downtime and improving decision-making in accelerator management.

Jain, Milan [PNL, Richland] (ORCID:000000021676111↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electromagnetic Radiation in the Plasma Environment Around the Shuttle

As part of the SAMPIE (The Solar Array Module Plasma Interaction Experiment) program, the Langmuir probe (LP) was employed to measure plasma characteristics during the flight STS-62. The whole set of data could be divided into two parts: (1) low frequency sweeps to determine voltage-current characteristics and to find electron temperature and number density; (2) high frequency turbulence (HFT dwells) data caused by electromagnetic noise around the shuttle. The broadband noise was observed at frequencies 250-20,000 Hz. Measurements were performed in ram conditions; thus, it seems reasonable to believe that the influence of spacecraft operations on plasma parameters was minimized. The average spectrum of fluctuations is in agreement with theoretical predictions. According to purposes of SAMPIE, the samples of solar cells were placed in the cargo bay of the shuttle, and high negative bias voltages were applied to them to initiate arcing between these cells and surrounding plasma. The arcing onset was registered by special counters, and data were obtained that included the amplitudes of current, duration of each arc, and the number of arcs per one experiment. The LP data were analyzed for two different situations: with arcing and without arcing. Electrostatic noise spectra for both situations and theoretical explanation of the observed features are presented in this report.

Vayner, Boris V.↗

Space Weather, Geomagnetic Disturbances and Impact on the High-Voltage Transmission Systems

Geomagnetically induced currents (GIC) affecting the performance of high-voltage power transmission systems are one of the most significant hazards space weather poses on the operability of critical US infrastructure. The severity of the threat was emphasized, for example, in two recent reports: the National Research Council (NRC) report "Severe Space Weather Events--Understanding Societal and Economic Impacts: A Workshop Report" and the North American Electric Reliability Corporation (NERC) report "HighImpact, Low-Frequency Event Risk to the North American Bulk Power System." The NRC and NERC reports demonstrated the important national security dimension of space weather and GIC and called for comprehensive actions to forecast and mitigate the hazard. In this paper we will give a brief overview of space weather storms and accompanying geomagnetic storm events that lead to GIC. We will also review the fundamental principles of how GIC can impact the power transmission systems. Space weather has been a subject of great scientific advances that have changed the wonder of the past to a quantitative field of physics with true predictive power of today. NASA's Solar Shield system aimed at forecasting of GIC in the North American high-voltage power transmission system can be considered as one of the ultimate fruits of those advances. We will review the fundamental principles of the Solar Shield system and provide our view of the way forward in the science of GIC.

Pullkkinen, A.↗

Hydration Mechanisms in Nanoparticle Interaction and Surface Energetics

Work on the project advanced molecular level understanding, prediction and control of nanoscale hydration in salt solutions under electric stimuli or ionic patterning. Permeation of nanoporous electrodes at preset voltage underlies the function of ultracapacitors. Transitory regulation of wetting in nanoporous media by electric field spans an array of applications in materials, energy storage, and separation sciences. The physically related modulation of nanoparticle solubility by surface charges can significantly extend the range of the nanomaterial applications, improve processing techniques, and potentially alleviate environmental concerns. Pore/solution equilibria, and activated kinetics of liquid gating by nanoconfined electrolytes are challenging problems at the forefront of experimental and theoretical research. Addressing these problems from a molecular perspective required the development of state-of-the-art simulation algorithms in statistical mechanics to capture complex processes in open systems under electric control. Parallel studies of wetting and dispersibility of polar and ionizing particles aim to uncover predictive relations between electrowetting, chemical functionalization, and geometry of nanomaterial particles. By nonequilibrium dynamic modeling, we elucidated electrolyte flow in nanochanels and associated electrokinetic energy conversion. Research on the program provided training opportunities for the next generation of scientists in computational chemistry. Insights, and methods from the project implicate broad segment of researchers in energy and nanosciences, materials and surface chemistry.

74 ATOMIC AND MOLECULAR PHYSICS↗

Townsend coefficients for electron scattering over dielectric surfaces

A method for describing the probability of initiating flashover discharges across dielectric surfaces is presented in which a transport coefficient for electron multiplication similar to the Townsend coefficient used for gas discharges is defined. The coefficient is a function of the scaling parameter (charge released from the cathode)/(cathode-anode separation) and is also a measure of the growth of the sheath on the dielectric surface resulting from electron scattering. Results are discussed as to when the source of seed electrons does not necessarily depend upon field emission at the cathode-vacuum-dielectric triple point. For these conditions, there is a different functional dependence of flashover probability on voltage and geometry than when field emission provides the seed electrons. As a result, criteria previously used to predict flashover discharges may not apply.

Peck, Timothy L.↗

Flight motor set 360L007 (STS-33R)

Flight motor set 360L007 was launched as part of NASA space shuttle mission STS-33R. As with all previous redesigned solid rocket motor launches, overall motor performance was excellent. There were no debris concerns for either motor. Both motors exhibited unbonds on one factory joint weatherseal. All ballistics contract end item specification parameters were verified, with the exception of ignition interval and rise rates. Ignition interval and rise rates could not be verified due to the elimination of developmental flight instrumentation from fourth flight and subsequent, but the low sample rate data that were available showed nominal propulsion performance. All ballistic and mass property parameters closely matched the predicted values and were well within the required contract end item specification levels that could be assessed. All 108 Ground Environment Instrumentation (GEI) measurements performed properly throughout the prelaunch phase. Evaluation of the GEI measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria thermal violations occurred. All joint heaters operated normally, but a high voltage reading was noted on the left hand aft heater, which was immediately determined to be a voltage sensor error and not a heater anomaly due to no current increase. Postflight inspection again verified superior performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints.

Garecht, Diane↗

Solar Power System Options for the Radiation and Technology Demonstration Spacecraft

The Radiation and Technology Demonstration (RTD) Mission has the primary objective of demonstrating high-power (10 kilowatts) electric thruster technologies in Earth orbit. This paper discusses the conceptual design of the RTD spacecraft photovoltaic (PV) power system and mission performance analyses. These power system studies assessed multiple options for PV arrays, battery technologies and bus voltage levels. To quantify performance attributes of these power system options, a dedicated Fortran code was developed to predict power system performance and estimate system mass. The low-thrust mission trajectory was analyzed and important Earth orbital environments were modeled. Baseline power system design options are recommended on the basis of performance, mass and risk/complexity. Important findings from parametric studies are discussed and the resulting impacts to the spacecraft design and cost.

Kerslake, Thomas W.↗

2-D Modeling of Nanoscale MOSFETs: Non-Equilibrium Green's Function Approach

We have developed physical approximations and computer code capable of realistically simulating 2-D nanoscale transistors, using the non-equilibrium Green's function (NEGF) method. This is the most accurate full quantum model yet applied to 2-D device simulation. Open boundary conditions and oxide tunneling are treated on an equal footing. Electrons in the ellipsoids of the conduction band are treated within the anisotropic effective mass approximation. Electron-electron interaction is treated within Hartree approximation by solving NEGF and Poisson equations self-consistently. For the calculations presented here, parallelization is performed by distributing the solution of NEGF equations to various processors, energy wise. We present simulation of the "benchmark" MIT 25nm and 90nm MOSFETs and compare our results to those from the drift-diffusion simulator and the quantum-corrected results available. In the 25nm MOSFET, the channel length is less than ten times the electron wavelength, and the electron scattering time is comparable to its transit time. Our main results are: (1) Simulated drain subthreshold current characteristics are shown, where the potential profiles are calculated self-consistently by the corresponding simulation methods. The current predicted by our quantum simulation has smaller subthreshold slope of the Vg dependence which results in higher threshold voltage. (2) When gate oxide thickness is less than 2 nm, gate oxide leakage is a primary factor which determines off-current of a MOSFET (3) Using our 2-D NEGF simulator, we found several ways to drastically decrease oxide leakage current without compromising drive current. (4) Quantum mechanically calculated electron density is much smaller than the background doping density in the poly silicon gate region near oxide interface. This creates an additional effective gate voltage. Different ways to. include this effect approximately will be discussed.

Svizhenko, Alexei↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Boost of the Bio-memristor Performance for Artificial Electronic Synapses by Surface Reconstruction

Biomaterial-based memristors (bio-memristors) are often adopted to emulate biological synapse functions and applied to construct neural computing networks in brain-inspired chip systems. However, the randomness of conductive filament formation in bio-memristors inhibits their switching performance by causing the dispersion of the device-switching parameters. In this case, a facile porous silk fibroin (p-SF) memristor was obtained through a protein surface reconstruction strategy, in which the size of the hole can be adjusted by the density of hybrid nanoseeds. Here, the porous SF memristors exhibit greatly enhanced electrical characteristics, including uniform I-V cycles, centralized distribution of the switching voltages, and both high and low resistances, compared to devices without pores. The results of three-dimensional (3D) simulations based on classical density functional theory (cDFT) suggest that the reconstructed pores in the SF layers guide the formation and fracture of Ag filaments under an electric field and enhance the overall conductivity by separating Ag + ion and electron diffusion pathways. Ag + ions are predicted to preferentially diffuse through pores, whereas electrons diffuse through the SF network. Interestingly, the device conductance can be bidirectionally modulated gradually by positive and negative voltages, can faithfully simulate short-term and long-term plasticity, and can even realize the triplet-spike-timing-dependent plasticity (triplet-STDP) rule, which can be used for pattern recognition in biological systems. The simulation results reveal that a memristor network of this type has an accuracy of ~95.78% in memory learning and the capability of pattern learning. This work provides a facile technology route to improve the performance of bionic-material memristors.

36 MATERIALS SCIENCE↗

WEST L-mode record long pulses guided by predictions using Integrated Modeling

A new record was set on the WEST Tokamak, designed to operate long duration plasmas in a tungsten (W) environment, with an injected energy of 1.15 GJ and a plasma duration 364s. Scenario development was supported by integrated modeling using the High Fidelity Plasma Simulator (HFPS), the European IMAS-coupled version of JETTO/JINTRAC, which integrates physics-driven modules into a unified framework. In particular, a reduced model for Lower-Hybrid heating and Current-Drive (LHCD) and the quasi-linear turbulent transport model TGLF are crucial for long pulses predictions up to the Last Closed Flux Surface (LCFS). Using this workflow, a 100 s reference discharge was modeled and plasma kinetic profiles and loop voltage were quantitatively well matched. In preparation for the recent long duration experiments, non-inductive current-drive actuators (I P , n e , P LHCD ) were varied to determine the operational domain going towards fully non-inductive discharges. In particular, decreasing the plasma current is shown to ease the access to such conditions, with a careful monitoring of (n e , P LHCD ) to avoid machine limitations. In addition, post-prediction experiments conducted within the investigated parameter range validated the predicted dependencies and were shown to be in quantitative agreement. Exploratory work on the use of ECCD for MHD stability purpose is also introduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measured current drainage through holes in various dielectrics up to 2 kilovolts in a dilute plasma

The electron current drained from a plasma through approximately 0.05 cm diameter holes in eight possible space applicable dielectrics placed on a probe biased at voltages up to 2000 V dc have been determined both theoretically and experimentally. The dielectrics tested were Parylene C and N, Teflon FEP type C, Teflon TFE, Nomex, quartz 7940 Corning Glass, Mylar A, and Kapton H polymide film. A Laplace field was used to predict an upper limit for the drainage current. The measured current was less than the computed current for quartz, Teflon FEP, and the 0.0123 cm thick sample of Parylene N for all voltages tested. The drainage current through the other dielectrics became equal to or greater than the computed current at a voltage below 2000 V. The magnitudes of the currents were between 0.1 and 10 microamperes for most of the dielectrics.

Grier, N. T.↗

HiPEP Ion Optics System Evaluation Using Gridlets

Experimental measurements are presented for sub-scale ion optics systems comprised of 7 and 19 aperture pairs with geometrical features that are similar to the HiPEP ion optics system. Effects of hole diameter and grid-to-grid spacing are presented as functions of applied voltage and beamlet current. Recommendations are made for the beamlet current range where the ion optics system can be safely operated without experiencing direct impingement of high energy ions on the accelerator grid surface. Measurements are also presented of the accelerator grid voltage where beam plasma electrons backstream through the ion optics system. Results of numerical simulations obtained with the ffx code are compared to both the impingement limit and backstreaming measurements. An emphasis is placed on identifying differences between measurements and simulation predictions to highlight areas where more research is needed. Relatively large effects are observed in simulations when the discharge chamber plasma properties and ion optics geometry are varied. Parameters investigated using simulations include the applied voltages, grid spacing, hole-to-hole spacing, doubles-to-singles ratio, plasma potential, and electron temperature; and estimates are provided for the sensitivity of impingement limits on these parameters.

Willliams, John D.↗

Data-driven search for promising intercalating ions and layered materials for metal-ion batteries

The rise in demand for lithium-ion batteries has led to a large-scale search for electrode materials and intercalating ion species to meet the demands of next-generation energy technologies. Recent efforts largely focus on searching for cathodes that can accommodate large amounts of intercalating ions, but similar work on anodes is relatively limited. This study utilizes machine learning methods to find alternative two-dimensional (2D) materials and intercalating ions beyond Li for metal-ion batteries with high-power efficiencies. The approach first uses density functional theory (DFT) calculations to estimate the theoretical capacities and voltages of various metal ions on 2D materials. The DFT-generated data also provide insights into the local structural accommodation upon ion intercalation on various 2D materials. Significant changes to the lattice can result in irreversible changes to the bonding environments in the anode material, resulting in poor cycling stability. Next, this study develops a binding energy and structural accommodation-based classification model to screen anode materials for next-generation batteries. The classification model selects intercalating ions and 2D material pairs suitable for batteries based on the calculated voltage and volumetric changes in the 2D material upon intercalation. Finally, this study builds a regression model to accurately predict the binding energies of the various intercalating ions on 2D materials. The approach highlights the importance of different elemental and structural features for classification and regression tasks. In conclusion, the insights gained from this study on the role of involved features, such as electronegativities of the constituent ions and the presence of unfilled electronic levels, will help to streamline further studies towards the search for future layered battery materials.

36 MATERIALS SCIENCE↗

Electro-Optical Characterization of Arsenic-Doped CdSeTe and CdTe Solar Cell Absorbers Doped in-situ During Close Space Sublimation

Most contemporary device models predict that an acceptor concentration of at least 10^16 cm^-3 is required to reach an open circuit voltage of 1 V in polycrystalline CdTe-based solar cells. While copper has traditionally been used as the de facto p-type dopant in polycrystalline cadmium telluride (CdTe) and cadmium selenide telluride (CdSeTe), reaching high acceptor concentrations has proved to be challenging in such devices due to significant dopant compensation. The acceptor concentration in copper-doped CdTe and CdSeTe typically ranges from 10^13 to 10^15 cm^-3 and routinely exhibit low external radiative efficiencies below 0.01%, limiting their implied voltage (i.e., quasi-Fermi level splitting) to approximately 900 mV. As an alternative to copper, this work explores the use of arsenic as a p-type dopant for CdTe and CdSeTe. Using a novel technique in which a thin layer of arsenic-containing material is deposited and used as a reservoir for arsenic to diffuse into a front layer of previously undoped material, this contribution demonstrates that high external radiative efficiencies are achievable, a direct result of combined high acceptor concentrations and long minority-carrier lifetimes in the absorber. This leads to improved implied voltages, and indicates that As-doping represents a promising pathway towards improving the external voltage of CdSeTe/CdTe solar cells.

cadmium telluride↗

Initial comparison of SSPM ground test results and flight data to NASCAP simulations

The satellite surface potential monitor (SSPM) has been developed for the P78-2 SCATHA (Spacecraft Charging At The High Altitudes) satellite to determine the response of selected spacecraft materials to charged-particle environmental fluxes. Since the monitor infers total surface voltages from a single point on the interior side of insulators, a ground simulation program was undertaken to develop analytical techniques to model the monitors and to obtain an experimental calibration of the relationship between the flight measurement techniques and actual measurements. The experimental testing was conducted using monoenergetic electron beams irradiating samples in the dark. An analytical computer model was developed in the NASCAP (NASA Charging Analyzer Program) code. The analytical model material properties for Kapton that controlled backscatter and secondary yield were adjusted to obtain a single set of values that produced reasonable fits for both voltages and currents. The analytical techniques developed in the ground technology investigation have been applied to space flight conditions. Predictions were compared with limited flight data. The agreement is very good indicating that the technique, and NASCAP, can be used to predict spacecraft material charging behavior. Details of the testing, the analytical modelling technique and flight data comparisons are presented.

Stevens, N. J.↗

Design concepts for a high-impedance narrow-band 42 GHz power TWT using a fundamental/forward ladder-based circuit

A low-cost, narrowband, millimeter wave space communications TWT design was studied. Cold test interaction structure scale models were investigated and analyses were undertaken to predict the electrical and thermal response of the hypothetical 200 W TWT at 42 GHz and 21 kV beam voltage. An intentionally narrow instantaneous bandwidth (1%, with the possibility of electronic tuning of the center frequency over several percent) was sought with a highly dispersive, high impedance "forward wave' interaction structure based on a ladder (for economy in fabrication) and nonspace harmonic interaction, for a high gain rate and a short, economically focused tube. The "TunneLadder' interaction structure devised combines ladder properties with accommodation for a pencil beam. Except for the impedance and bandwidth, there is much in common with the millimeter wave helix TWTs which provided the ideal of diamond support rods. The benefits of these are enhanced in the TunneLadder case because of spatial separation of beam interception and RF current heating.

Karp, A.↗