Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A Sequential Model Predictive and Deep Reinforcement Learning-Based Controller for Distribution System Outage Mitigation under Hurricane Events

This paper proposes a proactive outage mitigation framework for power distribution networks to withstand hurricane-induced disruptions. It leverages Model Predictive Control (MPC) to identify safe lines for proactive switching during hurricanes, minimizing the risk of cascading failures and voltage violations. The switching strategies optimized by MPC are sequentially integrated with a Deep Reinforcement Learning agent using the Advantage Actor-Critic algorithm, enabling dynamic line switching to maximize connected buses and minimize voltage violations in real time. Using a probabilistic hurricane model, the framework predicts line failures and adapts to varying conditions to enhance grid resilience. Simulations on the IEEE 123-bus system demonstrate its effectiveness in maintaining high connectivity and minimizing disruptions. Real-time testing with an RTDS confirms the practicality and reliability of the proposed approach.

Selim, Alaa [University of Connecticut]↗

Lightning Pin Injection Testing on MOSFETS

Lightning transients were pin-injected into metal-oxide-semiconductor field-effect transistors (MOSFETs) to induce fault modes. This report documents the test process and results, and provides a basis for subsequent lightning tests. MOSFETs may be present in DC-DC power supplies and electromechanical actuator circuits that may be used on board aircraft. Results show that unprotected MOSFET Gates are susceptible to failure, even when installed in systems in well-shielded and partial-shielded locations. MOSFET Drains and Sources are significantly less susceptible. Device impedance decreased (current increased) after every failure. Such a failure mode may lead to cascading failures, as the damaged MOSFET may allow excessive current to flow through other circuitry. Preliminary assessments on a MOSFET subjected to 20-stroke pin-injection testing demonstrate that Breakdown Voltage, Leakage Current and Threshold Voltage characteristics show damage, while the device continues to meet manufacturer performance specifications. The purpose of this research is to develop validated tools, technologies, and techniques for automated detection, diagnosis and prognosis that enable mitigation of adverse events during flight, such as from lightning transients; and to understand the interplay between lightning-induced surges and aging (i.e. humidity, vibration thermal stress, etc.) on component degradation.

Ely, Jay J.↗

Capacity contributions of Southern Oregon offshore wind to the Pacific Northwest and California

Variable renewable energy generation poses unique capacity challenges, which increasingly depend on weather events at varying timescales. Facilitated by transmission planning, geographic and technological diversity of the generation fleet may provide a mitigation to capacity shortfalls. In this work, offshore wind (OSW) energy is sited in the areas off the West Coast between Coos Bay, Oregon, and Crescent City, California. Three generation and transmission scenarios are modeled within the Western Interconnection: (i) 3.4 gigawatts (GW) of installed OSW capacity connected to Southern Oregon through a High Voltage Alternating Current (HVAC) Radial Topology in 2030; (ii) 12.9 GW of installed OSW capacity connected to Washington, Oregon, and California through a High Voltage Direct Current (HVDC) Radial Topology post-2030, and (iii) the same 12.9 GW connected to the same locations through a Multi-terminal DC (MTDC) Backbone Topology post-2030. Zonal dispatch simulations assuming coincident wind, solar, and hydropower production and loads over 18 meteorological years, accounting for temperature-dependent equipment derating and forced outages, serve as inputs to the Associated System Capacity Contribution (ASCC) methodology. The capacity credit is 33%, 25% and 34% for the 2030 HVAC Radial Topology, 2030+ HVDC Radial Topology, and 2030+ MTDC Backbone Topology, respectively. Transmission design is shown to mitigate the typical erosion of marginal capacity contribution as more OSW is developed, underscoring the opportunity for grid modernization while decarbonizing the generation mix.

17 WIND ENERGY↗

Impedance Analysis and PHIL Demonstration of Reactive Power Oscillations in a Wind Power Plant Using a 4-MW Wind Turbine

This paper presents impedance-based analysis, mitigation, and power-hardware-in-the-loop (PHIL) demonstration of reactive power oscillations in a wind power plant using a 4-MW Type III wind turbine drivetrain. Because such low-frequency oscillations result from interactions among slower control loops of wind turbines regulating phasor quantities—active and reactive power output of the wind turbine and the magnitude of voltages at the point of interconnection (POI)—a new type of admittance is defined in terms of phasor quantities for their analysis. The so-called power-domain admittance of a wind turbine is defined as the transfer function from the frequency and magnitude of voltages at the POI to the active and reactive power output of the turbine. The power-domain admittance responses of the 4-MW wind turbine are measured using a 7-MVA grid simulator to identify the source of the reactive power oscillations. Power-domain impedance analysis and PHIL experiments are performed to explain how a resonant mode manifests as turbine-to-turbine and plant-to-grid reactive power oscillations. It is discovered that weaker grids exhibiting high inductive impedance mitigate oscillations in the reactive power output of wind power plants; however, a higher grid impedance does not help in damping turbine-to-turbine reactive power oscillations. This paper presents a simple droop-based solution to eliminate both turbine-to-turbine and plant-to-grid reactive power oscillations.

17 WIND ENERGY↗

Mechanistic Insights into the Surface Instabilities of TiNb 2 O 7, a High‐Power Li‐Ion Anode

TiNb 2 O 7 (TNO) is a promising Li-ion battery anode for high-power applications, such as implantable medical devices and heavy-duty equipment. Hailed as being safe due to its elevated operating potential near 1.6 V, TNO has long been assumed to be highly stable in the carbonate-based electrolytes used in Li-ion batteries. Herein, all mechanisms occurring at the surface of both TNO and Nd-doped TNO are identified, and both materials in fact show significant gassing. CO 2 is even released at open circuit conditions, demonstrating the poor chemical stability of the material in the electrolyte even prior to battery operation. Such extreme instability is a critical safety concern. In addition, it was found that Ti dissolves from the surface of TNO particles at low voltage (below 1.4 V vs Li), and in fact deposits on the counter electrode. Ti further inside TNO particles then diffuses to the Ti-poor surface during discharge. Partial carbon-coating as a mitigating measure has also been tested and found to exacerbate these processes. The findings identify novel reactions occurring within TNO, and clearly highlight the need to stabilize the surfaces of TNO in order to prevent such aggressive deterioration at the surface of the particles.

25 ENERGY STORAGE↗

Layout and performance of HPK prototype LGAD sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology, will cover the pseudo-rapidity region of 2.4 < |n| < 4.0 with two end caps on each side and a total area of 6.4 m 2 . The timing performance can be improved by implanting an internal gain layer that can produce signals with a fast rising edge. It significantly improves the signal-to-noise ratio. The required average timing resolution per track for a minimum ionizing particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1MeV neutron-equivalent fluence up to 2.5 10 15 n eq /cm 2 including a safety factor of 1.5 before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-ups at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

47 OTHER INSTRUMENTATION↗

A Computational Framework for Identifiability and Ill-Conditioning Analysis of Lithium-Ion Battery Models

The lack of informative experimental data and the complexity of first-principles battery models make the recovery of kinetic, transport, and thermodynamic parameters complicated. We present a computational framework that combines sensitivity, singular value, and Monte Carlo analysis to explore how different sources of experimental data affect parameter structural ill conditioning and identifiability. Our study is conducted on a modified version of the Doyle-Fuller-Newman model. We demonstrate that the use of voltage discharge curves only enables the identification of a small parameter subset, regardless of the number of experiments considered. Furthermore, we show that the inclusion of a single electrolyte concentration measurement significantly aids identifiability and mitigates ill-conditioning.

25 ENERGY STORAGE↗

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Improving Durability of Fuel Cells with Platinum-rich Alloy Cathode Catalysts

Pt 3 Co-alloy based nanoparticle catalysts are very active for oxygen reduction reaction (ORR) thereby enabling high performance of proton exchange membrane fuel cells (PEMFC) for automotive propulsion. However, these catalyst materials degrade due to a combination of electrochemical surface area (ECSA) loss and dissolution of cobalt-alloying element from the nanoparticles. Dissolution of cobalt has a two-fold impact on the durability of fuel cells—i) a loss in the low-current density kinetic region due to a decrease in specific activity and ii) a loss in the high-current density transport region due to Co 2+ contamination of the ionomer phase. Cobalt dissolution-contamination needs to be mitigated as it limits fuel cell performance and lifetime for heavy-duty automotive applications. In this article, we study the use of PtCo-alloy catalysts with Pt-rich compositions using catalyst-specific accelerated stress test measurement in membrane electrode assemblies to decrease the amount of dissolved Co and mitigate its subsequent contamination effects. We demonstrate Pt 5 Co and Pt 7 Co compositions to enable significant improvements in durability (∼50 mV and ∼100 mV with respect to Pt 3 Co after 30,000 voltage cycles) with a minor but acceptable compromise in the initial specific activity of the catalyst.

08 HYDROGEN↗

Technical Note: An investigation of polarity effects for wide-angle free-air chambers

Purpose: Wide-angle free-air chambers (WAFACs) are used as primary standard measurement devices for establishing the air-kerma strength of low-energy, low-dose rate brachytherapy seeds. The National Research Council of Canada (NRC) is commissioning a primary standard wide-angle free-air chamber (NRC WAFAC) to serve the calibration needs of Canadian clients. The University of Wisconsin has developed a similar variable-aperture free-air chamber (UW VAFAC) to be used as a research tool. As part of the NRC commissioning, measurements were carried out for both polarities of the applied bias voltage and the resulting effects were observed to be very large. Similar effects were identified with the UW VAFAC. The authors describe the measurements carried out to determine the underlying causes of the polarity effect and the approach used to eliminate it. Methods: The NRC WAFAC is based on the WAFAC design developed at the National Institute of Standards and Technology in the USA. Charge measurements for {sup 125}I and {sup 241}Am sources were carried out for both negative and positive polarities on the NRC WAFAC and UW VAFAC. Two aperture sizes were also investigated with the UW VAFAC. In addition, measurements on the NRC WAFAC were carried out with a small bias between the collecting electrode and the shield foil at the downstream end of the chamber. To mitigate all of the polarity effects, the downstream surface of the collecting electrode was covered with a thin layer of graphite on both the NRC and UW chambers. Results: Both chamber designs showed a difference of more than 30 % between the charge collected with positive and negative bias voltages for the smallest electrode separation. It was shown for the NRC WAFAC that charge could be collected in the small gap downstream of the collecting volume by applying a voltage between the shield foil and the collecting electrode, even though an insulating foil (Mylar or polyimide film) separated the conducting surface from the small gap region. The unwanted additional current was shown to be proportional to the size of the aperture for the UW VAFAC. The extra ionization produced in the small gap region was eliminated for both chambers by covering the insulating side of the collecting electrode with a grounded conducting layer. Conclusions: The small gap region downstream of the collecting electrode in the NRC WAFAC and UW VAFAC can serve as an unwanted source of ion current. It is concluded that a residual electric field in the small gap region may lead to ion transport and to charge being trapped on the surface of the foil. The foil then acts as a capacitor with an equal charge, but of opposite sign, being attracted to the conducting surface. Covering the back of the collecting electrode surface with a grounded conducting layer eliminated the polarity effect.

61 RADIATION PROTECTION AND DOSIMETRY↗

Seismic Resilience of Large Power Transformer Bushings & Non-SF6 Industrial Base Scan Review

Large (high voltage) power transformers (LPT), and more specifically, their bushings, are known to be susceptible to seismic failure. With bushing failure, a transformer will have to be replaced, which has a considerable lead time, adding to the power outage duration. Cost-efficient, proven solutions are not currently available to mitigate this risk, which can persist for the more than 30-year life of a particular transformer. This work will focus on developing and demonstrating a hardware solution to address seismic vulnerabilities and reduce outage risks from LPT failure. Sulfur Hexafluoride (SF6) is a specialty gas with excellent electrical insulation properties which has been used extensively in the power industry. This gas is unfortunately also one of the most potent greenhouse gases known to humanity. A 2014 report by the Intergovernmental Panel on Climate Change found that SF6 has a global warming potential (GWP) 23,000 times higher than Carbon Dioxide, and has the highest GWP of all gases assessed (Myhre 2013). SF6 is almost exclusively man-made and is produced for use as an insulator in high voltage electrical equipment. This makes the production and use of SF6 one of the leading sources of anthropogenic climate change. To fully eliminate the environmental impacts of SF6, alternative technology is needed. The ideal replacement would be a technology that can fulfil the same role as SF6, at the same cost or cheaper, but without adverse environmental effects. Currently, no technology fits this description, however several promising technologies have begun to enter the market. An industry scan was performed to assess the state of industry adoption and manufacturing capability for SF6-free alternative technologies for use at the high-voltage level, and the primary barriers to broader adoption.

10 SYNTHETIC FUELS↗

New Synthesis Strategies to Improve Co-Free LiNi0.5Mn0.5O2 Cathodes: Early Transition Metal d0 Dopants and Manganese Pyrophosphate Coating

In this work, we report solution-based doping and coating strategies to improve the electrochemical performance of the Co-free layered oxide cathode LiNi0.5Mn0.5O2 (LNMO). Small amounts of d0 dopants (e.g., Mo6+and Ti4+, 0.5-1 at. %) increase the cathode’s specific capacity, cycling stability, and rate capability. More specifically, a Mo-doped cathode with the nominal composition LiNi0.495Mn0.495Mo0.01O2 achieves a high reversible capacity of 180 mAh/g at 20 mA/g with good retention at higher rates (e.g., 120 mAh/g at 100 mA/g). Effects of 1 at.% Mo dopant on the cathode structure were studied using a suite of characterization tools including X-ray diffraction (XRD), Raman spectroscopy, and transmission electron microscopy (TEM). These measurements demonstrate that Mo6+ reduces Li+/Ni2+cation mixing and mitigates undesirable phase transformations near the cathode surface during cycling. This work also reports the use of an inorganic Mn2P2O7 coating which enhances cycling stability, presumably through formation of a stable cathode electrolyte interphase (CEI) layer. Overall, the synthesis approaches reported herein are quite general and can potentially be expanded to other high voltage LIB cathodes.

Co-free cathodes, d0 cation, pyrophosphate coating↗

Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission

Offshore wind is expected to be a major player in the global efforts toward decarbonization, leading to exceptional changes in modern power systems. Understanding the impacts and capabilities of the relatively new and uniquely positioned assets in grids with high integration levels of inverter-based resources, however, is lacking, raising concerns about grid reliability, stability, power quality, and resilience, with the absence of updated grid codes to guide the massive deployment of offshore wind. To help fill the gap, this paper presents an overview of the state-of-the-art technologies of offshore wind power grid integration. First, the paper investigates the most current grid requirements for wind power plant integration, based on a harmonized European Network of Transmission System Operators (ENTSO-E) framework and notable international standards, and it illuminates future directions. The paper discusses the wind turbine and wind power plant control strategies, and new control approaches, such as grid-forming control, are presented in detail. The paper reviews recent research on the ancillary services that offshore wind power plants can potentially provide, which, when harmonized, will not only comply with regulations but also improve the value of the asset. The paper explores topics of wind power plant harmonics, reviewing the latest standards in detail and outlining mitigation methods. The paper also presents stability analysis methods for wind power plants, with discussions centered on validity and computational efficiency. Finally, the paper discusses wind power plant transmission solutions, with a focus on high-voltage direct-current topologies and controls.

17 WIND ENERGY↗

The use of a high-order MEMS deformable mirror in the Gemini Planet Imager

We briefly review the development history of the Gemini Planet Imager's 4K Boston Micromachines MEMS deformable mirror. We discuss essential calibration steps and algorithms to control the MEMS with nanometer precision, including voltage-phase calibration and influence function characterization. We discuss the integration of the MEMS into GPI's Adaptive Optics system at Lawrence Livermore and present experimental results of 1.5 kHz closed-loop control. We detail mitigation strategies in the coronagraph to reduce the impact of abnormal actuators on final image contrast.

79 ASTRONOMY AND ASTROPHYSICS↗

High Voltage Modeling and Testing of Transformer, Line Interface Devices, and Bulk System Components Under Electromagnetic Pulse, Geomagnetic Disturbance, and other Abnormal Transients

This project aims at quantitatively analyzing possible knowledge gaps related to the risk of Electromagnetic Pulse (EMP) impact on high-voltage, power transformers (transmission-class), that represent the most critical power grid assets. In relation to the electric infrastructure, some past studies indicate that the grid is overall fairly robust and resilient against most EMP threats. This assessment stems, in part, from estimates of the peak voltage that can be induced on a transmission power line for a nominal EMP fast-transient, compared with the typically very high basic insulation level that is featured by the high-voltage infrastructure. The project provides additional insight toward a more comprehensive risk evaluation of the grid EMP and Geomagnetic Disturbances (GMD) vulnerabilities. This work is aligned with the U.S. Dept. of Energy current research thrust in support of the development of a highly secure and resilient power infrastructure. Project milestones have been devised to address the fundamental technical issues in support of protection of large power transformer against EMP threats. More specifically, this project included parallel research tasks focused on the following topics: analysis of EMP-induced, fast-transient, current and voltages on a variety of power line configurations and EMP impact scenarios, detailed characterization of EMP damage potential due to the voltage surge, from the impact on the power line, to the transformer windings, GMD and EMP slow transients and impact from harmonics generation and reactive power flow on a complex grid layout, and identification of risk mitigation paths, with emphasis on GIC damage prevention for large power transformers, and on impact protection options from a grid stability perspective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA GRC and MSFC Space-Plasma Arc Testing Procedures

Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. Discussed herein are neutral gas conditions, plasma densities and uniformity, vacuum chamber sizes, sample sizes and Debye lengths, biasing samples versus self-generated voltages, floating samples versus grounded samples, test electrical conditions, arc detection, preventing sustained discharges during testing, real samples versus idealized samples, validity of LEO tests for GEO samples, extracting arc threshold information from arc rate versus voltage tests, snapover, current collection, and glows at positive sample bias, Kapton pyrolysis, thresholds for trigger arcs, sustained arcs, dielectric breakdown and Paschen discharge, tether arcing and testing in very dense plasmas (i.e. thruster plumes), arc mitigation strategies, charging mitigation strategies, models, and analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

Ferguson, Dale C.↗

Extension of Cable Electrical Assessment Techniques to Detect and Discriminate Radiation Aging on Cable Insulation Systems (Abstract)

The purpose of this study of the electrical responses of gamma radiation aged low voltage nuclear cables is to advance tools to determine cable condition (extent of damage) and identify degradation location along the cable length. The developed technology will provide nuclear plant operators with the options to focus cable repair, mitigation, or replacement efforts locally and avoid wholesale cable replacement.

42 ENGINEERING↗