Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Development of Labview based data acquisition and multichannel analyzer software for radioactive particle tracking system

A DAQ (data acquisition) software called RPTv2.0 has been developed for Radioactive Particle Tracking System in Malaysian Nuclear Agency. RPTv2.0 that features scanning control GUI, data acquisition from 12-channel counter via RS-232 interface, and multichannel analyzer (MCA). This software is fully developed on National Instruments Labview 8.6 platform. Ludlum Model 4612 Counter is used to count the signals from the scintillation detectors while a host computer is used to send control parameters, acquire and display data, and compute results. Each detector channel consists of independent high voltage control, threshold or sensitivity value and window settings. The counter is configured with a host board and twelve slave boards. The host board collects the counts from each slave board and communicates with the computer via RS-232 data interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hardware-in-the-Loop Co-Simulation Based Validation of Power System Control Applications

Renewables are key enablers for the realization of a sustainable energy supply but grid operators and energy utilities have to mange their intermittent behavior and limited storage capabilities by ensuring the security of supply and power quality. Advanced control approaches, automation concepts, and communication technologies have the potential to address these challenges by providing new intelligent solutions and products. However, the validation of certain aspects of such smart grid systems, especially advanced control and automation concepts is still a challenge. The main aim of this work therefore is to introduce a hardware-in-the-loop co-simulation-based validation framework which allows the simulation of large-scale power networks and control solutions together with real-world components. The application of this concept to a selected voltage control example shows its applicability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Better welds for launch vehicles

The use and benefits of automated variable polarity plasma arc (VPPA) welding of Al joints are described. The entire welding system, including welding head manipulator, weld-wire feed, torch, and power supply are computer controlled. The importance of proper torch dynamics and the control of argon gas flow through the plasma orifice are discussed. The use of arc-voltage control, the improvements in system monitoring, and the reduction or elimination of electromagnetic interferences are examined. VPPA welding is applicable to joining Space Shuttle components, and an example of its use on an External Tank of the Shuttle is presented.

Schwinghamer, Robert J.↗

Controlling Gas-Flow Mass Ratios

Proposed system automatically controls proportions of gases flowing in supply lines. Conceived for control of oxidizer-to-fuel ratio in new gaseous-propellant rocket engines. Gas-flow control system measures temperatures and pressures at various points. From data, calculates control voltages for electronic pressure regulators for oxygen and hydrogen. System includes commercially available components. Applicable to control of mass ratios in such gaseous industrial processes as chemical-vapor depostion of semiconductor materials and in automotive engines operating on compressed natural gas.

Morris, Brian G.↗

Computer Control For Gas/Tungsten-Arc Welding

Prototype computer-based feedback control system developed for use in gas/tungsten arc welding. Beyond improving welding technician's moment-to-moment general control of welding process, control system designed to assist technician in selecting appropriate welding-process parameters, and provide better automatic voltage control. Modular for ease of reconfiguration and upgrading. Modularity also reflected in software. Includes rack-mounted computer, based on VME bus, containing Intel 80286 and 80386 processors.

Andersen, Kristinn↗

Ionic Liquid Gating Control of RKKY Interaction in FeCoB/Ru/FeCoB and (Pt/Co) 2 /Ru/(Co/Pt) 2 Multilayers.

To overcome the fundamental challenge of the weak natural response of antiferromagnetic materials under a magnetic field, voltage manipulation of antiferromagnetic interaction is developed to realize ultrafast, high-density, and power efficient antiferromagnetic spintronics. Here, we report a low voltage modulation of Ruderman–Kittel–Kasuya–Yosida (RKKY) interaction via ionic liquid gating in synthetic antiferromagnetic multilayers of FeCoB/Ru/FeCoB and (Pt/Co) 2 /Ru/(Co/Pt) 2 . At room temperature, the distinct voltage control of transition between antiferromagnetic and ferromagnetic ordering is realized and up to 80% of perpendicular magnetic moments manage to switch with a small-applied voltage bias of 2.5 V. We related this ionic liquid gating-induced RKKY interaction modification to the disturbance of itinerant electrons inside synthetic antiferromagnetic heterostructure and the corresponding change of its Fermi level. In conclusion, voltage tuning of RKKY interaction may enable the next generation of switchable spintronics between antiferromagnetic and ferromagnetic modes with both fundamental and practical perspectives.

36 MATERIALS SCIENCE↗

Technologies for providing secure emergency power control of high voltage direct current transmission system

Technologies for providing secure emergency power control of a high voltage direct current transmission (HVDC) system include a controller. The controller includes circuitry configured to receive status data indicative of a present physical status of a power system. The circuitry is also configured to obtain an emergency power control command triggered by a remote source. The emergency power control command is to be executed by an HVDC transmission system of the power system. Further, the circuitry is configured to determine, as a function of the status data, whether the emergency power control command is consistent with the present physical status of the power system and block, in response to a determination that the emergency power control command is not consistent with the present physical status of the power system, execution of the emergency power control command by the HVDC transmission system.

Pan, Jiuping↗

Asymmetric Nafion-Coated Nanopore Electrode Arrays as Redox-Cycling-Based Electrochemical Diodes

Inspired by the functioning of cellular ion channels, pore-based structures with nanoscale openings, have been fabricated and integrated into ionic circuits, e.g. ionic diodes and transistors, for signal processing and detection. In these systems, the nonlinear current responses arise either because asymmetric nanopore geometries break the symmetry of the ion distribution, creating unequal surface charge across the nanopore, or by coupling unidirectional electron transfer within a nanopore electrode. Here, we develop a high-performance redox cycling-based electrochemical diode by coating an asymmetric ion-exchange membrane, i.e. Nafion, on the top surface of a nanopore electrode array (Nafion@NEA), in which each pore in the array exhibits one or more annular electrodes. Nafion@NEAs exhibit highly sensitive and charge-selective electroanalytical measurements due to efficient redox cycling reaction, the permselectivity of Nafion, and strong confinement of redox species in the nanopore array. In addition, the top electrode of dual electrode Nafion@NEAs can serve as a voltage-controlled switch to gate ion transport within the nanopore. Thus, Nafion@NEAs can be operated as a diode by switching voltages applied to the top and bottom electrodes of the NEA, leading to a large rectification ratio, fast response times, and simplified circuitry without the need for external electrodes. Here by taking advantage of closely spaced and individually addressable electrodes, the redox cycling electrochemical diode has the potential for application to large-scale production and electrochemically-controlled circuit operations which go well beyond conventional electronic diodes or transistors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multichannel VCO needs only one reference

Frequency stabilizing circuit controls output of multichannel microwave oscillator using passband filters and selector logic to eliminate need for separate crystal diode voltage controlled oscillator (VCO).

Masson, R. K.↗

A dual-amplifier hot-wire anemometer

The conceptual design of a dual-amplifier constant-temperature hot-wire anemometer is described. This hot-wire anemometer consists of three basic independent modules: a Wheatstone bridge in which the hot wire is one of its arms, an error-correction amplifier, and a voltage-controlled current source. The last two modules constitute the feedback network of this hot-wire anemometer. Thus the output voltage across the wire is a true function of the instantaneous changes in the wire resistance induced by the cooling effect of the flow. The dual-amplifier is capable of reaching relatively high frequency response through adequate selection of its active elements. Suitable gain of the error-correction amplifier and proper choice of the transfer function of the current source has yielded a frequency bandwidth up to 200 kHz.

Sadeh, W. Z.↗

Imbalance Mechanism and Balanced Control of Capacitor Voltage for a Hybrid Modular Multilevel Converter

Due to different charging and discharging characteristics of full-bridge submodules and half-bridge submodules in hybrid modular multilevel converters (MMC), capacitor voltage imbalance will occur under boosted ac voltage or reduced dc voltage conditions. To address this issue, the mechanism of capacitor voltage imbalance is carefully studied, with three main factors-modulation index, power angle, and hybridization ratio-summarized and their effect on capacitor voltage imbalance analyzed. Further, a control strategy based on fundamental frequency reactive circulating current injection is proposed to keep the capacitor voltage balanced in the hybrid MMC. The amplitude and phase angle of the injected circulating current are calculated and their influence on the energy fluctuation in the submodules' capacitors and the semiconductors' current stress is explored. Lastly, experimental results under boosted ac voltage and reduced dc voltage conditions demonstrate the feasibility and validity of the proposed scheme.

42 ENGINEERING↗

Material‐Driven Neuronal Oscillators and Filters via Active Reactance in CC‐NDR and VC‐NDR Electro‐Thermal Memristors

The continued scaling of artificial intelligence and telecommunications hardware is increasingly constrained by the power, bandwidth, and area limitations of transistor-based circuits. Neuromorphic processor units, analog oscillators, and active inductors and capacitors rely on complex multi-transistor architectures restricting material choices and incurring energy and footprint overhead. Here, we show that active reactance in electro-thermal memristors provides an intrinsic, material driven route to neuronal oscillator dynamics and signal processing. Using a physics-based compact modeling framework, we bridge negative differential resistance (NDR) and bias-tunable reactance, which underlies spiking dynamics in electro-thermal memristors. Memristors with negative temperature coefficients of resistance (TCR) manifest current-controlled (CC-) NDR and act as active inductors, thus generating spiking above a critical circuit capacitance; whereas memristors with positive TCR manifest voltage-controlled (VC-) NDR and active capacitance, leading to spiking above a critical inductance. By creating a compact model for La 0.7 Ca 0.3 MnO 3 as a representative VC-NDR material and comparing it with LaCoO 3 manifesting CC-NDR, we explain the physical origins of their distinct current-voltage characteristics, reactive phase shifts and consequent spiking behaviors. Finally, we demonstrate tunable filtering enabled by the active reactance of electro-thermal memristors, establishing them as a compact hardware platform for neuronal oscillator functionality and integrated filtering beyond conventional CMOS.

active reactance↗

Controlling a Four-Quadrant Brushless Three-Phase dc Motor

Control circuit commutates windings of brushless, three-phase, permanent-magnet motor operating from power supply. With single analog command voltage, controller makes motor accelerate, drive steadily, or brake regeneratively, in clockwise or counterclockwise direction. Controller well suited for use with energy-storage flywheels, actuators for aircraft-control surfaces, cranes, industrial robots, and other electromechanical systems requiring bidirectional control or sudden stopping and reversal.

Nola, F. J.↗

A 1.2-V 6-GHz Dual-Path Charge-Pump PLL Frequency Synthesizer for Quantum Control and Readout in CMOS 65-nm Process

This paper presents a low jitter dual-path chargepump phase locked loop (PLL) synthesizer in a CMOS 65-nm process for quantum readout applications. The PLL incorporates a programmable dual chargepump and a loop filter with both proportional and integral paths that can be driven independently providing flexible control of the loop bandwidth to achieve low jitter performance. The design is implemented at 300 K and critical blocks like voltage-controlled oscillator (VCO) and chargepump (CP) are analyzed at 77 K based on the characterized results. The LC-VCO is realized with the class-C NMOS only architecture with 5-bit coarse control and quadrature signals are generated with poly phase filter. The VCO is designed with the tuning range of 1 GHz around the center frequency of 6 GHz with Phase Noise of -123 dBc/Hz and -132 dBc/Hz at 1MHz offset at 300 K and 77 K temperature. The simulated PLL rms jitter is 125 fs at 6 GHz with a power consumption of 8 mW at the 1.2 V power supply.

47 OTHER INSTRUMENTATION↗

Trans-oceanic Remote Power Hardware-in-the-Loop: Multi-site Hardware, Integrated Controller, and Electric Network Co-simulation

Electric system operators are increasingly concerned with the potential system-wide impacts of the large-scale integration of distributed energy resources (DERs) including voltage control, protection coordination, and equipment wear. This prompts a need for new simulation techniques that can simultaneously capture all the components of these large integrated smart grid systems. This paper describes a novel platform that combines three emerging research areas: power systems co-simulation, power hardware in the loop (PHIL) simulation, and lab-lab links. The platform is distributed, real-time capable, allows for easy internet-based connection from geographically-dispersed participants, and is software platform agnostic. We demonstrate its utility by studying real-time PHIL co-simulation of coordinated solar PV firming control of two inverters connected in multiple electric distribution network models, prototypical of U.S. and Australian systems. Here, the novel trans-pacific closed-loop system simulation was conducted in real-time using a power network simulator and physical PV/battery inverter at power at the National Renewable Energy Laboratory in Golden, CO, USA and a physical PV inverter at power at the Commonwealth Scientific and Industrial Research Organisation's Energy Centre in Newcastle, NSW, Australia. This capability enables smart grid researchers throughout the world to leverage their unique simulation capabilities for multi-site collaborations that can effectively simulate and validate emerging smart grid technology solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

X-Band, 17-Watt Solid-State Power Amplifier

An advanced solid-state power amplifier that can generate an output power of as much as 17 W at a design operating frequency of 8.4 GHz has been designed and constructed as a smaller, lighter, less expensive alternative to traveling-wave-tube X-band amplifiers and to prior solid-state X-band power amplifiers of equivalent output power. This amplifier comprises a monolithic microwave integrated circuit (MMIC) amplifier module and a power-converter module integrated into a compact package (see Figure 1). The amplifier module contains an input variable-gain amplifier (VGA), an intermediate driver stage, a final power stage, and input and output power monitors (see Figure 2). The VGA and the driver amplifier are 0.5-m GaAs-based metal semiconductor field-effect transistors (MESFETs). The final power stage contains four parallel high-efficiency, GaAs-based pseudomorphic high-electron-mobility transistors (PHEMTs). The gain of the VGA is voltage-variable over a range of 10 to 24 dB. To provide for temperature compensation of the overall amplifier gain, the gain-control voltage is generated by an operational-amplifier circuit that includes a resistor/thermistor temperature-sensing network. The driver amplifier provides a gain of 14 dB to an output power of 27 dBm to drive the four parallel output PHEMTs, each of which is nominally capable of putting out as much as 5 W. The driver output is sent to the input terminals of the four parallel PHEMTs through microstrip power dividers; the outputs of these PHEMTs are combined by microstrip power combiners (which are similar to the microstrip power dividers) to obtain the final output power of 17 W.

Mittskus, Anthony↗

DATA-DRIVEN ALGORITHMS FOR DISTRIBUTION SYSTEM OPERATION AND CONTROL

Transactive energy systems are an alternative solution for the problems that distribution system operators face due to an increase in the use of distributed energy resources(DERs) and resulting much required scalability in managing active distribution system. To meet the reliability, sustainability and security requirement, ecient management and control of DERs including distributed generators, energy storage systems, and demand response is necessary. DERs can provide services such as reactive power compensation, voltage control, energy balancing, peak load reduction. These edge resources can also be used for system restoration after the extreme events within regulatory bound and enabling resiliency of the electric grid. While there are numbers of related work focused on solving these problems, availability of additional data resources has not been utilized to its potential to enable the reliable, sustainable and resilient electric grid. In order to address these challenges, data-driven algorithms have been proposed in this dissertation, including a) Volt/Var control, b) activity aware demand response and c) estimation of behind the meter distributed energy resources. Results indicate satisfactory performance of the developed algorithms.

ZHANG, YUE↗