Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vehicle electrification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Electrifying education: Exploring the electrification potential of U.S. School bus fleets

We analyze the operations of 270 diesel school buses across the United States to assess their electrification potential and evaluate the impact of various charging strategies on electricity demand. We find that school buses typically follow a two-route schedule on weekdays, featuring extended dwell times between morning and evening trips. Weekday trip distances average 25 miles, while weekend trips average 42 miles. Charging simulations indicate over 90% of the U.S. school bus fleet could be electrified using current technologies (300-mile range at 1.21 kWh/mile with 19.2-kW depot charging) without modifying existing operating patterns. Depot charging is a key enabler of school bus electrification, however, the strategic placement of charging stations at other locations (e.g., schools) can further increase electrification potential. Additionally, we find electric school bus charging to be highly flexible, with charge management capable of reducing peak charging loads at depots by up to 77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Battery anode design: From 1D nanostructure to 3D nanoarchitecture – Enabling next-generation energy storage technology

Recently, many studies have reported the efficacy of 1D silicon nanostructures as anode materials (mostly nanowires) due to their large surface to volume ratio which could be an advantage in terms of charging kinetics. Anode design is a crucial factor for the further development of lithium-ion battery (LIB) technology, especially in terms of achieving the high charging rate performance, as typically needed in electric vehicles (EV). 3D nanostructures have been identified as the key to dramatically enhanced charging rate of LIB, in addition to the change of materials (from carbon-based anode to silicon-based). However, existing fabrication methodologies for 3D nanostructures are inherently expensive – using advanced lithography techniques or other nanopatterning methodologies, as well as using additive manufacturing approaches. Electrospinning (as an integrated additive manufacturing methodology) may be used to produce low-cost 3D-printed fiber structures. Here, in the present study, we demonstrate the groundwork in this field of research in the past 3–4 years, which would allow the extension of this special additive manufacturing approach to reach nanoscale 3D-printed fiber structures more economically and with scalability for manufacturing. This would pave the way to achieve the order of magnitude increase in battery charging rate as needed to realize the vision of the electrification of mobility/transportation.

25 ENERGY STORAGE↗

Analyzing School Bus Electrification in Richmond, Virginia

School buses are an essential component of the transportation infrastructure, serving as a lifeline for students across the globe. However, the widespread use of diesel school buses has raised concerns about the health impact on millions of students exposed to harmful emissions daily. Recognizing this issue, school districts worldwide are urgently seeking cleaner energy alternatives. Electric school buses emerge as an environmentally friendly and sustainable option, fostering a healthier environment for both students and communities. However, school bus electrification faces the challenges of high upfront cost, cumbersome charging management, and constraints from power grids. To help school bus operators address those challenges, this study presents a data-driven analysis for school bus electrification. This study considered a real-world school bus system in Richmond, VA, and developed a mathematical programming model to analyze the system design, charging strategies, and charging load profiles for the electrification scenario. The study evaluated different charging strategies based on model outcomes, aiming to optimize efficiency and effectiveness. Ultimately, this research generated electric school bus charging demand profiles under various scenarios, shedding light on the feasibility and implications of transitioning to electric-powered school buses.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Charging and Subsequent Dissipation of a Rover Wheel in the Lunar Polar Regions

As a roving vehicle moves along the lunar surface, electric charge will build up through tribo-charging. This charge collected by the roving object will have a dissipative path to either the surface or the ambient plasma, depending upon which path is most conductive. At the lunar terminator region and into nightside regions, the surface is very cold and becomes a very poor conductor. leaving the plasma as the dominant remediating current for dissipation. However, within lunar craters, even plasma currents become substantially reduced which then greatly increases electric 'dissipation times, This work will involve the advancement of the stepping astronaut charge model, by considering the charging and plasma dissipation of a rolling rover wheel, The objective of this work is to determine the nature of charging and discharging for a rover wheel as it rolls along the cold, plasma-starved lunar polar regions. The rotating wheel accumulates charge via contact electrification (tribo-charging) with the lunar regolith. This tribo-charging is dependent on the composition of the objects in contact, with insulators and conductors charging differently. Given the environmental plasma in the region, we then determine the dissipation time for the wheel to bleed off its excess charge into the surrounding plasma. A model of the rover wheel rotating continuously over a surface regolith within a polar crater has been applied. The environmental plasma has been described previously. We define a new tribo-charging term specifically for the rotating system, with charge levels defined as a function of the wheel size, area in contact with the regolith, regolith particle size distribution, as well as the velocity at which the wheel is turning. We recognize that as charged dust accumulates and sticks to the wheel, this behaves effectively as a new current. Hence, the overall charging of the system should no longer vary linearly. and begin to show signs of saturation, We are devising a dust current term to model this charge-limiting effect, and will present the results in discussion.

Jackson, T. L.↗

Electric Mobility Opportunities for Brooklyn Park, Minnesota

This report will support Brooklyn Park as it navigates changes in mobility technologies and approaches to best serve the transportation needs of its communities. The content details the advantages of electric mobility, reviews electric mobility options that meet diverse needs and constraints, and maps the benefits and limitations of these options in terms of available technologies, their uses, and incentives that aim to improve accessibility and affordability. Although personal EVs provide both individual and collective advantages to residents - from lowering the total cost of ownership over the lifetime of a vehicle to improving air quality in the surrounding environment by reducing tailpipe emissions - they may still be unaffordable and/or inaccessible to some households in Brooklyn Park. Therefore, this report provides an overview of other accessible and affordable electric mobility options, including electric carshares, e-micromobility (i.e., e-scooters, e-bikes), and on-demand services, as enabled by web-connected technologies and the proliferation of smartphones.

33 ADVANCED PROPULSION SYSTEMS↗

Diversifying the Materials and Technologies for the Future of Energy Storage

It is increasingly important to meet the growing global energy demand driven by factors such as population growth, electrification, and the rapid development of emerging economies, while minimizing the environmental harm caused by carbon dioxide emissions. Although fossil fuels remain an abundant and inexpensive energy source, there is a global consensus on the critical importance of addressing climate change and an increasing urgency to reduce carbon dioxide emissions without hindering economic growth. This challenge is particularly daunting due to the significant transformations required in electricity generation systems, transportation, and industrial processes. A significant portion of our energy still comes from burning fossil fuels, which poses harmful effects on the environment. Transitioning to renewable energy sources like solar and wind is essential, as these sources provide a low-carbon pathway for power generation and have become increasingly cost-competitive with fossil fuels. However, they face the inherent challenge of intermittency. Thus, energy storage systems (ESS) are essential not only to address this issue but also to accommodate the increasing adoption of electric vehicles (EVs). Lithium-ion batteries (LIBs) are still the predominant ESS used for these applications; however, they suffer from issues related to scarce and harmful resources, safety, and socio-economic impacts. This underscores the need for alternative energy storage systems beyond LIBs. Here, in this review, we discuss the diversification, repurposing, and recycling of ESS to meet the projected energy demand while minimizing environmental harm.

batteries↗

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of Hydrogen Fuel Cell Technology for Freight Rail Propulsion and Review of Relevant Industry Standards.

Alternatives to conventional diesel electric propulsion are currently of interest to rail operators. In the U.S., smaller railroads have implemented natural gas and other railroads are exploring hydrogen technology as a cleaner alternative to diesel. Diesel, battery, hydrogen fuel cell, or track electrification all have trade-offs for operations, economics, safety, and public acceptability. A framework to compare different technologies for specific applications is useful to optimize the desired results. Standards from the Association of American Railroads (AAR) and other industry best practices were reviewed for applicability with hydrogen fuel cell technology. Some technical gaps relate to the physical properties of hydrogen, such as embrittlement of metals, invisible flames, and low liquid temperatures. A reassessment of material selection, leak/flame detection, and thermal insulation methods is required. Hydrogen is less dense and diffuses more easily than natural gas, and liquid hydrogen is colder than liquefied natural gas. Different densities between natural gas and hydrogen require modifications to tank designs and flow rates. Leaked hydrogen will rise rather than pool on the ground like diesel, requiring a modification to the location of hydrogen tanks on rolling stock. Finally, the vibration and shock experienced in the rail environment is higher than light-duty vehicles and stationary applications for which current fuel cell technology has been developed, requiring a modification in tank design requirements and testing.

08 HYDROGEN↗

Integration Methods for High-Density Integrated Electric Drives (Final Technical Report)

The project goal was to research, design and fabricate high-power-density, high-performance SiC power electronic modules for motor drive inverters in electric vehicles (EVs) to enable the subsequent motor drive to achieve a power density of 100 kW/l. EVs use electric motors instead of internal combustion engines as the prime mover, and their core components are semiconductor-based power electronic modules. Efficient power electronic modules play a vital role in power conversion systems. The performance of power modules directly affects the energy efficiency and overall performance of electric vehicles. Therefore, it is particularly important to develop power modules with high power density and high electrical performance that will perform reliably under EV environmental conditions. To achieve these goals, advanced electronic packaging technologies are required. This report describes a 5-year effort to integrate key aspects surrounding the basic power devices into the module itself to increase power density. These include sensing and sensing readout circuits, gate driver circuits, and two-sided cooling solutions.

33 ADVANCED PROPULSION SYSTEMS↗

An On-Demand Electric Transit Case Study of New Rochelle, New York

Here, this article characterizes the performance and ridership patterns of an on-demand transit (ODT) service utilizing lightweight electric vehicles (EVs) in New Rochelle, New York. Ridership sociodemographics, travel patterns (both temporal and spatiotemporal), and energy use from the service were explored using travel and survey data from September 2019 through December 2023. The ODT service was found to be used more by women (nearly 60%) and younger demographics (>65% under the age of 42), with peak use in the middle of the day and a grocery store as a top origin and destination. The service was utilized primarily for short trips (86% under 2 mi), with approximately one-third of riders using the ODT service to connect to a train or bus. The costs associated with fueling/charging were compared for different types of fleet vehicles, and the small, right-sized EVs were found to have annual charging costs that were roughly half of the refueling costs for conventional hybrid vans, and 24 times lower than a fleet of diesel buses. Evaluating the vehicle fleet and mapping current socio-spatial travel demand can inform system performance, guide service area development, and support future planning such as expansion to nearby communities and transit hubs. The findings in this case study suggest that on-demand electric transit may be a significant and growing space for advancing highly valued public mobility services. Public transport interventions that consider right-sized, electric, on-demand vehicles can help improve mobility access and reduce energy use and refueling costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

LA100 Equity Strategies. Chapter 12: Distribution Grid Upgrades for Equitable Resilience and Solar, Storage, and Electric Vehicle Access

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. As Los Angeles transitions toward clean energy, existing distribution grid infrastructure will need to be updated and expanded to support reliable service during routine operations, enable interconnection with distributed energy resources and electrified loads, and provide access to energy-related services during disasters. This chapter focuses on equity in distribution grid upgrades, reliability, and resilience in Los Angeles. Specifically, NREL performed grid upgrade and resilience analyses using a detailed model of the distribution grid and income-differentiated household load profiles, electric vehicle (EV) adoption patterns, distributed solar adoption, and grid reliability to explore two key questions to inform how the City of Los Angeles can ensure a resilient and reliable distribution grid for all communities during the clean energy transition: Where can distribution system upgrades can be prioritized to enable equitable access to, and adoption of, clean energy technologies and how can Los Angeles provide equitable, resilient access to electricity-related services (e.g., health care, food) during disaster events like earthquakes and flooding? The electric distribution system is the "last mile" of the grid, linking the multistate bulk power system with customers; new loads, including EVs; and distributed energy resources, such as customer and community solar and storage. This analysis focuses on the 4.8-kilovolt (kV) system, including service transformers that represent the utility-side of the grid connection for most residential customers. Chapter 17 looks at the customer-side of the grid connection with a focus on electric panel upgrade needs. The transition toward clean energy can put additional stress on the distribution system from distributed energy resources and electrification - especially EVs and increased use of electricity for heating, cooling, cooking, and hot water. This stress, measured here as the number of equipment overloads and voltage violations, correlates strongly to grid reliability and therefore is used as a proxy for understanding additional upgrades needed and to help ensure equitable access to electrification and distributed energy resources. NREL also conducted community resilience analysis to examine customer-level access to both electricity and a larger range of services, such as hospitals and grocery stores during a disaster. This analysis explicitly considers equity to understand differences in current resilience and resilience strategies to effectively improve critical services access for all Angelenos. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

Why Regional and Long-Haul Trucks are Primed for Electrification Now

Zero emission freight trucks are needed to both improve public health and reduce global greenhouse gas emissions but at the same time are generally believed to be uneconomical. However, recent dramatic declines in battery prices and improvement in their energy density have created opportunities for battery-electric trucking today that were seldom anticipated just a few years ago. At the current global average battery pack price of $135 per kilowatt-hour (kWh) (realizable when procured at scale), a Class 8 electric truck with 375-mile range and operated 300 miles per day when compared to a diesel truck offers about 13% lower total cost of ownership (TCO) per mile, about 3-year payback and net present savings of about US $200,000 over a 15-year lifetime. This is achieved with only a 3% reduction in payload capacity. Even this small penalty can be reversed cost-effectively through light-weighting, in any case, only matters for a small fraction of trucks which regularly utilize their maximum payload. Electric trucks appear poised to also meet the performance demands for a large share of regional and long-haul trucking today. The estimated average distance traveled between 30- minute driver breaks is 150 miles and 190 miles for regional-haul and long-haul trucks respectively in the US. Thirty minutes of charging using 500 kW or mega-Watt scale fastchargers would add sufficient range without impairing operations and economics of freight movement. However, as with almost any clean technology, higher upfront capital costs of both vehicles and charging infrastructure are major barriers when electric trucking is in its infancy. Without strong policy support, coordinated investments in both vehicle manufacturing and fuel infrastructure will not be forthcoming on the scale needed to harness the true potential of battery electric trucks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Policy implications of net-zero emissions: A multi-model analysis of United States emissions and energy system impacts

Many countries, subnational jurisdictions, and companies are setting net-zero emissions goals; however, questions remain about strategies to reach these targets, policy measures, technology gaps, and economic impacts. Here, we investigate the potential policy implications of reaching economy-wide net-zero CO 2 emissions across the United States by 2050 using results from a multi-model comparison with 14 energy-economic models. Model results suggest that achieving net-zero CO 2 targets depends on policies that accelerate deployment of zero- and low-emitting technologies that have seen rapid cost reductions in recent years (including wind, solar, battery storage, and electric vehicles) as well as relatively nascent options (including carbon capture and storage, advanced biofuels, low-carbon hydrogen, advanced nuclear, and long-duration energy storage). While net-zero policies are likely to lower fossil fuel consumption, including considerable coal and petroleum reductions, achieving net-zero emissions does not necessarily mean phasing out all fossil fuels. Model results indicate that the Inflation Reduction Act’s energy and climate provisions amplify near-term decarbonization but that net-zero policies have larger impacts on long-run outcomes. Stringent climate policy can have large fiscal impacts on tax revenue and government spending—revenues from carbon pricing and subsidies for carbon removal range from 0.1 % to 3.7 % of GDP in 2050 across models. Each dollar per metric ton carbon price leads to a 0.06 % to 0.31 % reduction in economy-wide CO 2 emissions relative to a reference scenario with current policies. Spending on energy across the economy decreases relative to today for many models under reference and net-zero policies, especially as a share of GDP, due primarily to end-use electrification and energy efficiency.

54 ENVIRONMENTAL SCIENCES↗

Weather Sensitive High Spatio-Temporal Resolution Transportation Electric Load Profiles For Multiple Decarbonization Pathways

Electrification of transport compounded with climate change will transform hourly load profiles and their response to weather. We present a novel approach to generating hourly electric load profiles that considers charging strategies and evolving sensitivity to temperature. The approach consists of downscaling annual state-scale sectoral load projections from the multisectoral Global Change Analysis Model (GCAM) into hourly electric load profiles leveraging high resolution climate and population datasets. Profiles are developed and evaluated at the Balancing Authority scale, with a 5-year increment until 2050 over the Western U.S. Interconnect for multiple decarbonization pathways and climate scenarios. The datasets are readily available for production cost model analysis. Our open source approach is transferable to other regions.

Decarbonization, tranportation, Electric vehicle c↗

I-80 Mid-America Clean Fuels Corridor: Deployment Plan Report

The I-80 Mid-America Clean Fuels Corridor, which spans I-80 from Fort Lee, New Jersey, to Council Bluffs, Iowa, was designated an Alternative Fuels Corridor (AFC) in Round 1 of the Alternative Fuels Corridor program administered by the U.S. Department of Transportation’s (DOT’s) Federal Highway Administration (FHWA). Originally called the “I-80 Mid-America Alternative Fuels Corridor,” it is now named the “I-80 Mid-America Clean Fuels Corridor.” As of Round 6 AFC designation, parts of the corridor have sufficient direct current fast charging (DCFC) stations to be designated Electric Vehicle (EV)-Ready and sufficient compressed natural gas (CNG) fueling stations to be designated CNG-Ready. However, much of the corridor’s approximately 1,240 miles (mi) are not yet EV- or CNG-Ready. This includes about 1,130 mi that are designated EV-Pending and 700 mi that are designated CNG-Pending. This report presents a plan to develop EV charging and CNG fueling infrastructure sufficient to convert the entire length of the corridor to EV-Ready and CNG-Ready. Specific sites are not identified for future infrastructure. Rather, priority exits are identified, and information, analysis, and additional steps are recommended to support further refinement of these locations, as well as additional outreach and deployment efforts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Electric Aircraft Thermal Management: Now, New Visions and Future Concepts and Formulation

The global fuel consumption by commercial airlines has increased each year since 2009 and is predicted to reach an all-time high of 97 billion gallons in 2019. There is also an environmental impact from this: CO2 emissions from commercial passenger and freight operations totaled 918 Mt in 2018 (ICCT, 2019), or around 2.5% of global energy-related CO2 emissions. Passenger transport accounted for 81% of the total. Emissions from aviation have grown 32% over the past five years. Coupled with this aspect, there is a continuous and growing need to satisfy ever-growing electrical power needs on commercial and military aircraft. All the armed services (Army, Navy, and Air Force) are continuously trying to enhance UAV (unmanned aerial vehicle) endurance and range across a broad fleet of different aircraft. The commercial Boeing 787 requires about 1.2MWe and that is expected to grow. Current technologies used to supply increased on-board electrical power are generally: 1) “burn more fuel and convert through on-board generators” and 2) use additional heavy (i.e., weight-inefficient) and sometimes unsafe battery systems on-board the aircraft. The aircraft industry is seeking new, innovative ways to satisfy this increasing power demand. One as-yet-untapped power source is the enormous amount of “waste” thermal energy flowing out the jet engine exhaust; some estimates in smaller “by-pass” flow jet engines is several hundreds of kilowatts (e.g., Pratt & Whitney Canada PW545B turbofan). This quantity is much higher in large jet engines associated with commercial aircraft. This large waste thermal energy manifests itself in large temperature differences within the by-pass-flow engine exhaust system relative to outside ambient conditions, because of the actual by-pass engine design configuration. There is strong need to develop thermal technologies and systems that could harness and convert at least a portion of this thermal energy into useful electrical energy to satisfy growing on-board electrical needs. In addition, there is a strong desire within the aircraft and engine manufacturing community to reduce the “carbon footprint” of the industry though reduced fuel usage worldwide. NASA has a robust aircraft electrification program to meet these desires and support industry in its aircraft electrification objectives. This program is integrating thermoacoustic systems, advanced lightweight heat exchanger technology, and advanced heat pipe technology to capture and transport large amounts of engine waste thermal energy for on-board power conversion, advanced heat-pump cooling, and exergy enhancement (i.e., temperature lift). Advanced lightweight heat exchangers are envisioned to capture engine exhaust thermal energy at approximately 673 K and deliver it to efficient thermoacoustic power conversion systems operating at temperature ratios (Thot/Tcold) > 1.6. Advanced heat pipe systems are envisioned to transport thermal energy from low temperature sources, through thermoacoustic heat pumps, to high temperature needs such as wing anti-icing, fuel pre-heating, and combustion air pre-heating. The paper will discuss the current state-of-the-art, objectives, system design architecture, and remaining technical challenges in system formulation within the NASA aircraft electrification program.

Dyson, Rodger↗

Dataset of U.S. School Bus Depots

A large body of public health literature describes how undesirable or dangerous facilities, such as truck depots and industrial plants, located in or near communities can lead to health harms. Research also describes the high levels of traffic-related air and noise pollution that is linked to health harms and may be disproportionately distributed near many schools. Therefore, a primary use case for this dataset is to analyze the location of school bus depots and to create an evidence base that would better enable the work of community members, advocates, and other stakeholders toward improving air quality and public health. Other possible uses for this school bus depot dataset include electricity grid planning and reliability, given recent momentum toward school bus electrification. This dataset was created using an object-based approach with remote sensing data. The primary source of aerial imagery was the National Agriculture Imagery Program (NAIP) dataset. NAIP imagery was analyzed to locate individual school buses based on their color and size, and then classified clusters of school buses as potential depots, which were then verified visually. The resulting dataset contains 11,309 depots across the 48 contiguous U.S. states and Washington, D.C. Fifty-one percent (5,730 depots) are at schools, defined as being 350 meters or less from the nearest school. The accuracy of the dataset was assessed by comparing it with independent reference datasets containing 506 depots from the records of two school transportation companies. We found good agreement, with an omission error rate of 15.2% (77 depots). This dataset represents one of the only remote sensing projects to conduct object detection using data at the sub-meter to 1-meter resolution for a continental-scale application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗