Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

HydraGNN_Predictive_GFM_2026 - Ensemble of predictive graph foundation models for atomistic materials modeling

This release contains data and parameters of HydraGNN-based graph foundation models trained as a result of the work published in the pre-print "Exascale Multi-Task Graph Foundation Models for Imbalanced, Multi-Fidelity Atomistic Data" by M. Lupo Pasini et al. (https://arxiv.org/abs/2604.15380). We jointly train on 16 open first-principles datasets (544+ million structures covering 85+ elements) using a multi-task architecture with per-dataset heads and a scalable ADIOS2/DDStore data pipeline. On Frontier, we execute six large-scale DeepHyper hyperparameter optimization campaigns in FP64 and promote the top-performing message-passing models to sustained 2,048-node training, yielding a PaiNN-based lead model. The version of HydraGNN used to generate the outputs provided in this release is HydraGNN v5.0 (https://github.com/ORNL/HydraGNN/releases/tag/v5.0) The list of datasets used for the training of the graph foundation model is the following: 1) Alexandria [1] 2) ANI1x [2] 3) MPTrj [3] 4) Open Catalyst 2020 (OC20) [4] 5) Open Catalyst 2022 (OC22) [5] 6) Open Catalyst 2025 (OC25) [6] 7) Open Direct ir Capture 2023 (ODAC23) [7] 8) Open Materials 2024 (OMat24) [8] 9) Open Molecules 2025 (OMol25) [9] 10) OMol25-neutral (subset of OMol25 that contains only molecules with zero total charge) 11) OMol25-non-neutral (subset of OMol25 that contains only molecules with non-zero total charge) 12) Open Polymers 2026 (OPoly2026) [10] 13) Nabla2DFT [11] 14) QCML [12] 15) QM7X [reference 13] 16) transition1x [14] Dataset references: [1] J. Schmidt et al., “A dataset of 175k stable and metastable materials calculated with the PBEsol and SCAN functionals,” Scientific Data, vol. 9, p. 64, 2022. [2] J. S. Smith et al., “The ANI-1ccx and ANI-1x data sets, coupled-cluster and density functional theory properties for molecules,” Scientific Data, vol. 7, p. 134, 2020. [Online]. Available: https: //www.nature.com/articles/s41597-020-0473-z [3] A. Jain et al., “Commentary: The Materials Project: A materials genome approach to accelerating materials innovation,” APL Materials, vol. 1, no. 1, p. 011002, 07 2013. [Online]. Available: https://doi.org/10.1063/1.4812323 [4] L. Chanussot et al., “Open catalyst 2020 (oc20) dataset and community challenges,” ACS Catalysis, vol. 11, no. 10, pp. 6059–6072, 2021. [Online]. Available: https://doi.org/10.1021/acscatal.0c04525 [5] K. Tran et al., “Open catalyst 2022 (oc22) dataset and challenges for oxidation electrocatalysts,” ACS Catalysis, vol. 13, no. 5, pp. 3066–3084, 2023. [Online]. Available: https://doi.org/10.1021/acscatal.2c05426 [6] S. J. Sahoo et al., “The open catalyst 2025 (oc25) dataset and models for solid-liquid interfaces,” arXiv preprint arXiv:2509.17862, 2025. [Online]. Available: https://arxiv.org/abs/2509.17862 [7] A. Sriram et al., “The open DAC 2023 dataset and challenges for sorbent discovery in direct air capture,” ACS Central Science, vol. 10, no. 5, pp. 923–941, 2024. [8] L. Barroso-Luque et al., “Open materials 2024 (omat24) inorganic materials dataset and models,” 2024. [Online]. Available: https://arxiv.org/abs/2410.12771 [9] D. S. Levine et al., “The open molecules 2025 (OMol25) dataset, evaluations, and models,” 2025. [Online]. Available: https://arxiv.org/abs/2505.08762 [10] D. S. Levine et al., The open polymers 2026 (OPoly26) dataset and evaluations,” arXiv preprint arXiv:2512.23117, 2025. [Online]. Available: https://arxiv.org/abs/2512.23117 [11] K. Khrabrov et al., “Nabla2dft: A universal quantum chemistry dataset of drug-like molecules and a benchmark for neural network potentials,” in NeurIPS 2024 Datasets and Benchmarks Track, 2024. [Online]. Available: https://openreview.net/forum?id=ElUrNM9U8c [12] S. Ganscha et al., “The QCML dataset, quantum chemistry reference data from 33.5M DFT and 14.7B semi-empirical calculations,” Scientific Data, vol. 12, p. 406, 2025. [13] J. Hoja et al., “QM7-X, a comprehensive dataset of quantum-mechanical properties spanning the chemical space of small organic molecules,” Scientific Data, vol. 8, p. 43, 2021. [Online]. Available: https://www.nature.com/articles/s41597-021-00812-2 [14] M. Schreiner et al., “Transition1x - a dataset for building generalizable reactive machine learning potentials,” Scientific Data, vol. 9, p. 779, 2022. The folder "datasets_ADIOS2_format" contains the set of pre-processed datasets in Adaptable I/O System (ADIOS) format (https://www.exascaleproject.org/research-project/adios/) that have been used for the development and training of GFMs in this work. The "datasets_ADIOS2_format" directory contains 2 sub-directories, one for the version "v1" of the datasets and one for the version "v2" of the datasets. The version "v1" of the datasets provides values of the total energy as they are extracted from the original data as it was released by the respective institutions. The version "v2" of the datasets provides values of the energy that have been realigned. The realignment was performed by training a linear regression model that predicts the total energy as a function of the chemical composition of the atomistic structure, and then subtract such prediction from the original value of the total energy. Both folders "v1" and "v2" contain 16 sub-directories, each corresponding to an ADIOS2-formatted dataset The folder "DeepHyper-results" contains the configurational files and model's parameters for all the 186 HPO trials that were successfully completed by the scalable hyperparameter optimization (HPO) runs on Frontier. The content of the folder "DeepHyper-results" I structured as follows: 1) task-list.txt: list of mpnn name, jobid, and deephyper task id 2) gfm_${MPNN}_${JOBID}_0.${TASKID}: run directory with checkpoint files 3) gfm_${MPNN}: deephyper summary directory (*.csv) for each specific MPNN type 4) deephyper-experiment-${JOBID}: output and error logs for each job The file "deephyper-sorted.csv" contains the details of each HydraGNN model built and tested by HPO, obtained by merging the (*.csv) filed from each HPO run executed. Out of all the HPO trials, we selected 10 to continue the training of the respective HydraGNN models. Due to limited computational budget available in the LRN070 allocation we could not complete the training till convergence for all these 10 selected models. The folder "models" contains multiple sub-folders, one per each HydraGNN model trained. Each model sub-folder contains the parameters of each HydraGNN model, with multiple checkpoint-restarts. The list of sub-folders are as follows: 1) multidataset_hpo-BEST1-fp64 2) multidataset_hpo-BEST2-fp64 3) multidataset_hpo-BEST3-fp64 4) multidataset_hpo-BEST4-fp64 5) multidataset_hpo-BEST5-fp64 6) multidataset_hpo-BEST6-fp64 7) multidataset_hpo-BEST7-fp64 8) multidataset_hpo-BEST8-fp64 9) multidataset_hpo-BEST9-fp64 10) multidataset_hpo-BEST10-fp64 Within each one of these folders, additional auxiliary log files are provided with descriptions about how the training proceeded. The lead PaiNN-model is contained inside "multidataset_hpo-BEST6-fp64". The file "mlp_branch_weights" contains the parameters of the multi-layer perceptron (MLP) used to reconcile the predictions of the 16 output decoding heads of the HydragNN architectures. The MLP takes in input the chemical composition of the atomistic structure and predicts averaging weights to linearly mix the predictions of each output decoding head toward consolidating them into a single one. The folder "1.1billion-structure-inference" contains 1.1 billion atomistic structures randomly generated. Each structures is associated with energy and forces predicted with the lead-PaiNN model combined with the MLP model for reconciliation of the multi-branch predictions generated by the 16 output decoding heads. The folder "1.1billion-structure-inference" contains 9,300 (*.tar.gz) subdirectories, one per Frontier compute node used to execute the inference at exascale. Once uncompressed, each (*.tar.gz) subdirectory contains an ADIOS2 (*.bp) file container, where each atomistic structure is stored as a PyTorch-Geometric Data object. The file "export_dataset_environment_variables.sh" contains the environment variables that need to be set before running the HydraGNN code to reproduce the results provided in this dataset release. The code that can be used to load the ADIOS2 files, load HydraGNN models, and run inference is available at: https://github.com/ORNL/HydraGNN/releases/tag/v5.0

36 MATERIALS SCIENCE↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase I Conceptual Study)

The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and the proposed system is an improvement over alternate low carbon dispatchable power options. Our demonstration will include 54 MWh of hydrogen storage. CO 2 capture inherent to the CHG process can capture 90% of the CO 2 (with upgrades to >98%) in a commercial system (~300 MWth) for sequestration or other uses. The hydrogen will be utilized in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with the existing Southern Company fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load. However, H 2 production is relatively constant by storing H 2 , and revenues are improved by arbitrage between use of low-cost off-peak variable electricity generation or use of stored H 2 under peak demand. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via system requirements review with the whole team. These requirements were then incorporated into/iterated with our Heat & Mass Balance models and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Our system generates power at 17.4% lower cost than other low carbon approaches for the H 2 generation, H 2 compression and storage, carbon sequestration, and HRSG added electricity production for a large-scale duct-fired system. Our team recommends completing the Phase II Pre-FEED study for the proposed system as the next step for the project and its tasks will achieve the overall objective and be ready to launch the FEED. The Pre-FEED tasks include updating the requirements, Concept of Operations, plant scope/process description, component modeling, system modeling, performance estimates, emission estimates, block flow diagrams, fluid/process conditions (PFD), utility usage, and facility sizing/definition. The approach will be to complete these updates in a greater level of detail for the selected site. The approach for developing the EIV is to use the updated results, including model outputs, for carbon dioxide and waste streams.

03 NATURAL GAS↗

HFIR Activity Workbook Generator (HAWK) User Guide

The HFIR Activity WorkbooK generator (HAWK) is a Python code that automates and streamlines the activity calculation of samples after irradiation in the High Flux Isotope Reactor (HFIR). HAWK’s results provide estimates of the activity and nuclide inventory of irradiated specimens before they are moved to hot cell facilities, where they undergo post-irradiation examination. The samples’ activity results guide the packing of shipping containers and inform the accountable inventories for the hot cell facilities. The toolkit was originally developed by Charles Daily, a former R&D staff member at Oak Ridge National Laboratory (ORNL). As of May 2025, HAWK is developed by the Radiation Transport & HPC Methods Group (Nuclear Energy and Fuel Cycle Division) at ORNL. Figure 1 presents HAWK’s workflow. To use HAWK, users need to: 1. Develop an Excel input workbook (i.e., XLSX extension) containing data from the experiment’s materials, irradiation history (cycles), and irradiation positions. 2. Make minor edits to an existing template JSON file (i.e., auxiliary_data.JSON) and to the Python driver. The driver sets the necessary environment variables, defines the material compositions, and ultimately calls HAWK. Once configured, HAWK runs the Oak Ridge Isotope Generation code (ORIGEN) to calculate the masses, activities, and heat load at the end of irradiation for each isotope in the specimen. ORIGEN is part of SCALE, ORNL’s in-house computational tool for performing nuclear safety and design calculations. Following this step, HAWK postprocesses the results and generates three output workbooks summarizing the activity calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Characterizing Output Bottlenecks of a Production Supercomputer: Analysis and Implications

This article studies the I/O write behaviors of the Titan supercomputer and its Lustre parallel file stores under production load. The results can inform the design, deployment, and configuration of file systems along with the design of I/O software in the application, operating system, and adaptive I/O libraries.We propose a statistical benchmarking methodology to measure write performance across I/O configurations, hardware settings, and system conditions. Moreover, we introduce two relative measures to quantify the write-performance behaviors of hardware components under production load. In addition to designing experiments and benchmarking on Titan, we verify the experimental results on one real application and one real application I/O kernel, XGC and HACC IO, respectively. These two are representative and widely used to address the typical I/O behaviors of applications.In summary, we find that Titan’s I/O system is variable across the machine at fine time scales. This variability has two major implications. First, stragglers lessen the benefit of coupled I/O parallelism (striping). Peak median output bandwidths are obtained with parallel writes to many independent files, with no striping or write sharing of files across clients (compute nodes). I/O parallelism is most effective when the application—or its I/O libraries—distributes the I/O load so that each target stores files for multiple clients and each client writes files on multiple targets in a balanced way with minimal contention. Second, our results suggest that the potential benefit of dynamic adaptation is limited. In particular, it is not fruitful to attempt to identify “good locations” in the machine or in the file system: component performance is driven by transient load conditions and past performance is not a useful predictor of future performance. For example, we do not observe diurnal load patterns that are predictable.

97 MATHEMATICS AND COMPUTING↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing Distribution System Resilience: A First-Order Meta-RL Algorithm for Critical Load Restoration

The increasing frequency of extreme events and the integration of distributed energy resources (DERs) into modern grids have elevated the need for resilient and efficient critical load restoration strategies in distribution systems. However, the stochastic nature of renewable DERs, limited energy resource availability and the intricate nonlinearities inherent in complex grid control problem make the problem challenging. Although reinforcement learning (RL) and warm-start RL methods have shown promising results, their performance often falls short in rapidly adapting to new, unseen situations and typically requires exhaustive problem-specific tuning. To address these gaps, we propose a First-Order Meta-based RL (FOM-RL) algorithm within an online framework for adaptive and robust critical load restoration. By harnessing local DERs as the enabling technology, FOM-RL allows the RL agent to swiftly adapt to new unseen scenarios by leveraging previously acquired knowledge of different tasks. Experimental results provide evidence that proposed algorithm learns more efficiently and showcases generalization capabilities across diverse set of operational scenarios. Moreover, a rigorous theoretical analysis yields a tight sublinear regret bound, sensitive to temporal variability, with a task-averaged optimality gap bounded by O(VM+D*/(Tsquare root(M))). These results suggest that optimality improves with task similarity and an increased number of tasks M, reaffirming the efficacy and scalability of the proposed approach in addressing the complexities of critical load restoration in distribution systems.

complexity theory↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Intensive and extensive margins of the peak load: Measuring adaptation with mixed frequency panel data

In this work we investigate the response of daily electricity peak load to daily maximum temperatures across states in Europe and India. We propose a method that decomposes short- from medium/long-run effects, retains the high frequency nature of the load-weather covariation and treats economic growth as a modulating factor. By simultaneously exploiting variation in unexpected daily weather anomalies and decade-long climatic changes in each location we decompose transitory - intensive margin - adjustments from permanent - extensive margin - adjustments. We find that the shocks over the long-run differ substantially from the short-run dynamics. Furthermore, we find evidence that per capita income modulates the adjustments over the short- and long-run. We project that in response to climate change around 2050 the peak load may increase by up to 20%-30% in Southern Europe and in several states in India, depending on the degree of warming and the evolution of socio-economic conditions. Even with a limited scope to two world regions, we identify that the structure of the economy and differences in future income growth matter in shaping the adaptation to climate change. Our decomposition allows to identify how future weather anomalies can further amplify the relative increase associated to the shift in the climate norm. Assuming that the interannual variability of maximum temperatures follows the distribution observed in the past, we find a doubling of the impacts of climate change during the summer in Europe. Uncertainty around the distribution of future weather anomalies may lead to further unexpected peak load amplifications. Our results have important policy implications for power systems’ generation capacity, transmission and storage, as we show that the challenges to accommodate the peak load in days with extreme temperatures may substantially increase already around mid-century.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Role of Regional Connections in Planning for Future Power System Operations Under Climate Extremes

Identifying the sensitivity of future power systems to climate extremes must consider the concurrent effects of changing climate and evolving power systems. We investigated the sensitivity of a Western U.S. power system to isolated and combined heat and drought when it has low (5%) and moderate (31%) variable renewable energy shares, representing historic and future systems. We used an electricity operational model combined with a model of historically extreme drought (for hydropower and freshwater-reliant thermoelectric generators) over the Western U.S. and a synthetic, regionally extreme heat event in Southern California (for thermoelectric generators and electricity load). We found that the drought has the highest impact on summertime production cost (+10% to +12%), while temperature-based deratings have minimal effect (at most +1%). The Southern California heat wave scenario impacting load increases summertime regional net imports to Southern California by 10-14%, while the drought decreases them by 6-12%. Combined heat and drought conditions have a moderate effect on imports to Southern California (-2%) in the historic system and a stronger effect (+8%) in the future system. Southern California dependence on other regions decreases in the summertime with the moderate increase in variable renewable energy (-34% imports), but hourly peak regional imports are maintained under those infrastructure changes. By combining synthetic and historically driven conditions to test two infrastructures, we consolidate the importance of considering compounded heat wave and drought in planning studies and suggest that region-to-region energy transfers during peak periods are key to optimal operations under climate extremes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning reference governor for cycle-to-cycle combustion control with misfire avoidance in spark-ignition engines at high exhaust gas recirculation–diluted conditions

Cycle-to-cycle feedback control is employed to achieve optimal combustion phasing while maintaining high levels of exhaust gas recirculation by adjusting the spark advance and the exhaust gas recirculation valve position. The control development is based on a control-oriented model that captures the effects of throttle position, exhaust gas recirculation valve position, and spark timing on the combustion phasing. Under the assumption that in-cylinder pressure information is available, an adaptive extended Kalman filter approach is used to estimate the exhaust gas recirculation rate into the intake manifold based on combustion phasing measurements. The estimation algorithm is adaptive since the cycle-to-cycle combustion variability (output covariance) is not known a priori and changes with operating conditions. A linear quadratic regulator controller is designed to maintain optimal combustion phasing while maximizing exhaust gas recirculation levels during load transients coming from throttle tip-in and tip-out commands from the driver. During throttle tip-outs, however, a combination of a high exhaust gas recirculation rate and an overly advanced spark, product of the dynamic response of the system, generates a sequence of misfire events. In this work, an explicit reference governor is used as an add-on scheme to the closed-loop system in order to avoid the violation of the misfire limit. The reference governor is enhanced with model-free learning which enables it to avoid misfires after a learning phase. Experimental results are reported which illustrate the potential of the proposed control strategy for achieving an optimal combustion process during highly diluted conditions for improving fuel efficiency.

42 ENGINEERING↗

Reducing the computational burden of a microgrid energy management system

As renewable technology advances and decreases in cost, microgrids are becoming an appealing means of distributed generation both for isolated communities and integrated with existing electrical grid systems. Due to their small size, however, microgrids may have financial limitations which preclude them from using commercial software to optimize control of their assets. Open-source optimization solvers are a viable alternative, but increase computation time. This work expands on a rolling horizon optimization framework for economic dispatch within an existing residential microgrid located in Hoover, Alabama. The microgrid has an open-source solver requirement and a need for quick solution time on a rolling horizon as opposed to a day-ahead commitment. We present a method of reducing integer variables by relaxation which completes two goals: reduction in computation time for real-time operations, and reduction in daily operational cost for the microgrid. Seasonal data for load and photovoltaic (PV) power was also collected from the microgrid to facilitate simulation testing. Computation time was successfully reduced using multiple variations of the relaxation method, while obtaining solution quality with operational cost similar to or better than the original model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing thermal comfort and participation in residential demand flexibility programs

Residential space-conditioning-based demand flexibility (DF) has become an increasingly sought-after method for demand-side load management to enhance grid reliability and facilitate integration of renewable energy generation. However, predicting the effectiveness and flexibility of residential DF resources is challenging due to the variability in household energy use behaviors. Current estimates show that only 50 % of projected savings from DF resources are actualized due to regulatory, technological, and social barriers. From a household perspective, concerns over thermal comfort during space conditioning-based DF events significantly impact participation decisions. Currently, there is a very limited understanding of how thermal comfort during space-conditioning-based DF events in real-world settings impacts household energy use behaviors and, consequently, the success of DF programs in achieving targeted savings. This paper proposes a method to comprehensively assess the thermal comfort implications of DF strategies and presents results of their impacts on DF event participation decisions and demand savings. Here, the proposed method was applied to a heat pump DF field study in Cordova, Alaska. The study’s key findings are: 1) DF event setpoint offsets that maintain indoor operative temperatures between 18 to 22 °C (65 to 71°F) may be preferred in Cordova, Alaska; 2) Household-level thermal comfort is more sensitive to the duration of the DF event than to the degree of temperature offset from baseline conditions; 3) The delayed impact of changes in indoor operative temperature in response to setpoint offsets, both during and after a DF event, influences occupants’ thermal comfort perceptions and willingness to persistently participate in events. The findings from application of the proposed method can help inform future larger-scale occupant-centric DF programs as it can capture information not readily available through utility and device-level energy use data. Thus, it can supplement these sources and help program administrators develop occupant-centric DF strategies, enabling more accurate predictions of participation rates and savings estimates for space-conditioning-based DF programs.

Demand side management↗

3-D Geologic Controls of Hydrothermal Fluid Flow at Brady geothermal field, Nevada, USA

In many hydrothermal systems, fracture permeability along faults provides pathways for groundwater to transport heat from depth. Faulting generates a range of deformation styles that cross-cut heterogeneous geology, resulting in complex patterns of permeability, porosity, and hydraulic conductivity. Vertical connectivity (a throughgoing network of permeable areas that allows advection of heat from depth to the shallow subsurface) is rare and is confined to relatively small volumes that have highly variable spatial distribution. This local compartmentalization of connectivity represents a significant challenge to understanding hydrothermal circulation and for exploring, developing, and managing hydrothermal resources. Here, we present an evaluation of the geologic characteristics that control this compartmentalization in hydrothermal systems through 3-D analysis of the Brady geothermal field in western Nevada. A published 3-D geologic map of the Brady area is used as a basis to develop structural and geological variables that are hypothesized to control or effect permeability or connectivity. The 3-D distribution of these variables is compared to the distribution of productive and non-productive fluid flow intervals along production wells and non-productive wells via principal component analysis (PCA). This comparison elucidates which geologic and structural variables are most closely associated with productive fluid flow intervals. Results indicate that production intervals at Brady are located: (1) within or near to known and stress-loaded macro-scale faults, and (2) in areas of high fault and fracture density.

58 GEOSCIENCES↗

Multimodal Nanoscale Mapping of Local Structure and CO 2 Adsorption in Metal–Organic Frameworks

Diamine functionalization of the metal−organic framework Mg 2 (dobpdc) (dobpdc 4− = 4,4′-dioxidobiphenyl-3,3′-dicarboxylate) significantly enhances its selectivity for CO 2 capture from flue gases and air. The structure and CO 2 capacity of such materials are typically assessed using bulk techniques that rely on averaging signal over large ensembles of unit cells, obscuring local heterogeneities, such as variations in CO 2 occupancy across individual nanocrystals. To resolve this limitation, we demonstrate a multimodal, nanoscale characterization of Mg 2 (dobpdc) appended with 1,3-diaminopropane. By employing recently developed characterization techniques at progressively smaller length scales, we uncover insights from correspondingly smaller populations of unit cells. First, we use parallel-beam 3D electron diffraction (3D ED) to identify a prominent expansion in lattice parameters upon desorption of CO 2 , as observed at the level of single nanocrystals. Second, we use convergent-probe 4D scanning transmission electron microscopy (4D-STEM) to quantify associated differences in lattice strain as a function of gas loading and diamine appending. These measurements sample small subvolumes within individual nanocrystals. Finally, we apply infrared scattering scanning near-field optical microscopy (IR s- SNOM) to confirm variable CO 2 chemisorption across adsorption sites at the surface of single nanocrystals. This multimodal, multiscale approach allows us to map heterogeneity within individual nanocrystals. Collectively, these findings emphasize the importance of local, nanoscale characterization of metal−organic frameworks in revealing previously unresolvable features that impact their performance.

Karstens, Sarah L. [University of California, Berk↗

The Hidden Flexibility of the Natural Gas Network for Electric Power Operations: A Case Study of a Near-Miss Winter Event

The U.S. power sector has become increasingly reliant on gas pipeline networks to deliver fuel to natural gas power plants. In addition to supplying relatively low-cost fuel, gas networks offer generators flexibility in their operations through the ability to deliver fuel when needed by using gas storage facilities or linepack if the gas network is at an operating point below its design capacity. However, disruptions or stress events on the gas network - like those occurring in the Northeast and Texas in recent years - can result in limitations on gas availability to generators at times when generation is in short supply. Here we examine a period of stress that occurred in the winter of 2022 in the Western United States. Using data on the region's natural gas pipeline network and electric generators, we build an integrated gas and electric model that closely replicates the actual dispatch of the period. We then evaluate the implications of removing flexibility employed by the gas network operator, which during that period curtailed scheduled gas deliveries to other parties to increase deliveries to natural gas power plants, which requested more gas than initially forecasted. We find that without the flexibility supplied by the gas network operator, there would have been curtailment of gas generation due to gas offtake constraints, requiring the power system operator to redispatch relying on more expensive generation or to potentially shed load. A sensitivity exploring a wind drought further exacerbates the strain, illustrating the potential challenge of managing gas and grid interactions as systems move to higher shares of variable renewable electricity. Based on this example, we discuss potential coordination strategies between the two system operators to ensure that the power system can successfully utilize and rely on the flexibility offered by natural gas networks.

03 NATURAL GAS↗