Two-Stage Variable Sample-Rate Conversion System

A two-stage variable sample-rate conversion (SRC) system has been pro posed as part of a digital signal-processing system in a digital com munication radio receiver that utilizes a variety of data rates. The proposed system would be used as an interface between (1) an analog- todigital converter used in the front end of the receiver to sample an intermediatefrequency signal at a fixed input rate and (2) digita lly implemented tracking loops in subsequent stages that operate at v arious sample rates that are generally lower than the input sample r ate. This Two-Stage System would be capable of converting from an input sample rate to a desired lower output sample rate that could be var iable and not necessarily a rational fraction of the input rate.

Tkacenko, Andre↗

Phosphate‐functionalized Zirconium Metal–Organic Frameworks for Enhancing Lithium–Sulfur Battery Cycling

Abstract Lithium–sulfur batteries are promising candidates for next‐generation energy storage devices due to their outstanding theoretical energy density. However, they suffer from low sulfur utilization and poor cyclability, greatly limiting their practical implementation. Herein, we adopted a phosphate‐functionalized zirconium metal–organic framework (Zr‐MOF) as a sulfur host. With their porous structure, remarkable electrochemical stability, and synthetic versatility, Zr‐MOFs present great potential in preventing soluble polysulfides from leaching. Phosphate groups were introduced to the framework post‐synthetically since they have shown a strong affinity towards lithium polysulfides and an ability to facilitate Li ion transport. The successful incorporation of phosphate in MOF‐808 was demonstrated by a series of techniques including infrared spectroscopy, solid‐state nuclear magnetic resonance spectroscopy, and X‐ray pair distribution function analysis. When employed in batteries, phosphate‐functionalized Zr‐MOF (MOF‐808‐PO4) exhibits significantly enhanced sulfur utilization and ion diffusion compared to the parent framework, leading to higher capacity and rate capability. The improved capacity retention and inhibited self‐discharge rate also demonstrate effective polysulfide encapsulation utilizing MOF‐808‐PO4. Furthermore, we explored their potential towards high‐density batteries by examining the cycling performance at various sulfur loadings. Our approach to correlate structure with function using hybrid inorganic–organic materials offers new chemical design strategies for advancing battery materials.

Liu, Bingqian↗

Reese Housing Power Project (Final Technical Report)

The Reese Housing Power Project is located on Tribal trust land in Colusa, CA and expands existing medium-voltage distribution to seven new households with the addition of medium-voltage cabling, step down transformers, smart meters, and street lighting for the new development. The Tribe utilized their existing Co-Generation power plant and micro grid to supply the new homes with highly reliable power with fewer interruptions and at a reduced rate compared with the local utility. The project gives the Tribe greater independence from traditional power sources and provides jobs for the community. The project reduces electric energy costs, increases Tribe self-reliance, and provides highly reliable electric power to seven tribal members’ homes. Construction of the project also provided jobs for the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Generators

When Enerpro, Inc. president, Frank J. Bourbeau, attempted to file a patent on a system for synchronizing a wind generator to the electric utility grid, he discovered Marshall Space Flight Center's Frank Nola's power factor controller. Bourbeau advanced the technology and received a NASA license and a patent for his Auto Synchronous Controller (ASC). The ASC reduces generator "inrush current," which occurs when large generators are abruptly brought on line. It controls voltage so the generator is smoothly connected to the utility grid when it reaches its synchronous speed, protecting the components from inrush current damage. Generator efficiency is also increased in light winds by applying lower than rated voltage. Wind energy is utilized to drive turbines to generate electricity for utility companies.

Source record↗

Data for Catalyst and Reactor Design Considerations for Selective Production of Acids by Oxidative Cleavage of Alkenes with H2O2

Oxidative cleavage of alkenes and unsaturated fatty acids with hydrogen peroxide gives an efficient and sustainable process to obtain mono- and di-acids for polymers and lubricants with fewer safety risks and less environmental impact than processes that utilize ozone or other inorganic oxidizers (e.g., permanganate, dichromate, etc.). Guided by insight into the mechanisms for competing reaction pathways (i.e., epoxidation of alkene on W–(η2-O2) complexes vs. H2O2 decomposition) and the apparent kinetics derived from kinetic experiments, here, we postulate that W-based heterogeneous catalysts can provide high performance and stable operations at low H2O2 concentrations. Semi-batch reactors with continuous introduction of H2O2 solutions offer the means to maintain low H2O2 concentrations while providing sufficient quantities of H2O2 to satisfy the reaction stoichiometry. We derived simple kinetic model equations for the epoxidation, ring-opening, oxidative cleavage, and oxidation steps and fit theses equations to batch experimental data to obtain kinetic parameters. This kinetic model describes the concentration profiles of reactant, oxidant, and products well as shown by agreement with experimental data. Further predictions of the optimal H2O2 feed rate for semi-batch operation utilized by the proposed rate expressions and the reactor design equations suggest that low H2O2 feed rate increases selectivity towards oxidative cleavage products and selective use of H2O2 for oxidative cleavage pathway. Comparisons of oxidative cleavage of 4-octene in batch and semi-batch reactors show that semi-batch reactors with optimized molar feed rates of H2O2 increased oxidative cleavage product selectivities (76% to 99%; with an increase in butyric acid selectivity from 1% to 55%) and H2O2 selectivity (3% to 30%). In addition, semi-batch reaction conditions used avoid H2O2-mediated dissolution of W-atoms from the catalyst. Analysis of these findings suggest that solid oxide catalysts will be effective for continuous oxidative cleavage reactions if deployed within fixed-bed reactors that allow for distributed introduction of reactants and therefore low in situ concentrations of H2O2.

Catalysis↗

Catalyst and reactor design considerations for selective production of acids by oxidative cleavage of alkenes and unsaturated fatty acids with H 2 O 2

Oxidative cleavage of alkenes and unsaturated fatty acids with hydrogen peroxide gives an efficient and sustainable process to obtain mono- and di-acids for polymers and lubricants with fewer safety risks and less environmental impact than processes that utilize ozone or other inorganic oxidizers (e.g., permanganate, dichromate, etc.). Guided by insight into the mechanisms for competing reaction pathways (i.e., epoxidation of alkene on W–(η 2 -O 2 ) complexes vs. H 2 O 2 decomposition) and the apparent kinetics derived from kinetic experiments, here, we postulate that W-based heterogeneous catalysts can provide high performance and stable operations at low H 2 O 2 concentrations. Semi-batch reactors with continuous introduction of H 2 O 2 solutions offer the means to maintain low H 2 O 2 concentrations while providing sufficient quantities of H 2 O 2 to satisfy the reaction stoichiometry. We derived simple kinetic model equations for the epoxidation, ring-opening, oxidative cleavage, and oxidation steps and fit theses equations to batch experimental data to obtain kinetic parameters. Furthermore, this kinetic model describes the concentration profiles of reactant, oxidant, and products well as shown by agreement with experimental data. Further predictions of the optimal H 2 O 2 feed rate for semi-batch operation utilized by the proposed rate expressions and the reactor design equations suggest that low H 2 O 2 feed rate increases selectivity towards oxidative cleavage products and selective use of H 2 O 2 for oxidative cleavage pathway. Comparisons of oxidative cleavage of 4-octene in batch and semi-batch reactors show that semibatch reactors with optimized molar feed rates of H 2 O 2 increased oxidative cleavage product selectivities (76% to 99%; with an increase in butyric acid selectivity from 1% to 55%) and H 2 O 2 selectivity (3% to 30%). In addition, semibatch reaction conditions used avoid H 2 O 2 -mediated dissolution of W-atoms from the catalyst. Analysis of these findings suggest that solid oxide catalysts will be effective for continuous oxidative cleavage reactions if deployed within fixed-bed reactors that allow for distributed introduction of reactants and therefore low in situ concentrations of H 2 O 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Valuation and cost reduction of behind-the-meter hydrogen production in Hawaii

A 250kW hydrogen electrolysis facility was recently installed at the Natural Energy Laboratory of Hawaii Authority's (NELHA's) campus. This facility that will begin operation in 2020 to produce hydrogen for fuel cell buses on the island to demonstrate of the application of hydrogen to decarbonize transportation. Given the size of the electrolysis station, it has the potential to significantly increase electricity costs for the campus, which is subject to energy and peak demand charges from the local utility. In this paper, we analyze the cost of hydrogen production at NELHA given the rate structure options available from the utility. Production costs are estimated using optimal versus constant scheduling of the facility to meet the buses’ demand. A model of the electrolysis station is used to capture changes in production efficiency over the power range in the optimization routine. The effects of combining the station and campus load versus standalone operation and increasing solar generation are also explored. The analyses surrounding this scenario show the importance of multiple factors on the potential profitability of hydrogen production in behind-the-meter applications and show trends that could have implications for other similar installations.

08 HYDROGEN↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic and operational investigation of CO 2 sequestration through enhanced oil recovery in unconventional reservoirs in Colorado, USA

The ongoing CCUS commercial projects are highly relied on the support of government incentives due to massive capital investment. Here, this study analyzes the economics of carbon capture utilization and sequestration (CCUS) projects, shows a state-wide CCUS deployment exercise, followed by simulation results of enhanced oil recovery (EOR) based CO 2 storage in unconventional reservoirs. The comprehensive economic analysis of capture, transportation, sequestration costs, enhanced 45Q tax credits, and EOR revenue implies the practicality of CO 2 -EOR to offset the high CCUS costs. With the economics understanding, we study the top CO 2 sources, existing CO 2 pipelines, and sequestration sinks in the state of Colorado, USA. This paper next presents results from EOR simulation in one section of the unconventional Denver-Julesburg (DJ) Basin Niobrara and Codell reservoirs. The simulation model is based on a geological static model, incorporated with hydraulic fracture stimulation, history matched to production, and calibrated to the microseismic and time-lapse surface seismic data. The CO 2 -EOR simulation results show that oil production can be increased and more CO 2 stored with: a longer primary production period; the presence of a shut-in period; higher injection rates; and multi-well injectors. The modeling results show that about 7–10 Mscf of CO 2 will be stored when recovering 1 stb of EOR oil. By adding the enhanced oil revenue and the carbon credits together, it is estimated that the most economic case can generate $\$13$ MM when oil price is assumed to be $\$80$/stb, and the EOR oil revenue is 3.4 times greater than that generated from 45Q incentives. It corresponds to the scenario that a five-year primary production is followed by CO 2 injection into four wells with the sequence of injection (4 MMscf/day for 6 months), shut-in (6 months) and production (12 months). The best practices in this study will provide valuable insights for similar CCUS projects in other unconventional fields. Furthermore, this study defines a term named “Carbon Neutrality Index (CNI)” by comparing the amount of CO 2 stored with that burned by EOR oil. The CNI value of 0 indicates the enhanced oil is carbon neutral; a negative CNI value implies there is a net reduction in carbon emission. The 4-year huff-n-puff (HnP) simulation leads to a positive CNI value, indicating that the EOR oil generated in this process is not carbon neutral yet.

03 NATURAL GAS↗

Bias and spread in EVT performance tests.

Performance tests (error probability measurements) of communications systems characterized by low bit rates and high reliability requirements frequently utilize classical extreme value theory (EVT) to avoid the excessive test times encountered with bit error rate (BER) tests. If the underlying noise is Gaussian or perturbed Gaussian, the EVT error estimates have either excessive bias or excessive variance if an insufficient number of test samples is used. EVT is examined to explain the cause of this bias and spread. Experimental verification is made by testing a known Gaussian source, and procedures that minimize these effects are described. It seems apparent that even under the best of conditions the EVT test results are not particularly better than those of BER tests.

Smith, J. G.↗

Learning-based CO 2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation

There have been increasing concerns over the air quality inside buildings as high levels of bio-effluents can cause nausea, dizziness, headaches, and fatigue to the people working in those spaces. First published in 2004 as Standard 62.1, ASHRAE Standard 62.2-2019 requires highly occupied spaces to implement heating, ventilation, and air conditioning (HVAC) that can dilute contaminants produced by occupants. In this regard, occupant-centric ventilation control has been regarded as an effective practice to maintain a satisfactory indoor air quality (IAQ) when dealing with highly variable occupancy environments. However, few established models in current literature and practice consider dynamic occupancy behavior and adaptive IAQ control. To address this gap, a dynamic indoor CO2 model is constructed using machine learning algorithms to forecast CO2concentrations across a range of forecasting horizons. Herein, we tuned and compared six state-of-the-algorithms—including Support Vector Machine, Ada Boost, Random Forest, Gradient Boosting, Logistic Regression, and Multilayer Perceptron. The algorithms’ performances are validated using CO 2 and historical meteorological data collected from a campus classroom with a variable occupancy rate. Simulation results showed that Multilayer Perceptron can strongly predict the volatile CO 2 behavior and also outperforms other algorithms in terms of accuracy. Furthermore, a control strategy capable of modeling and detecting dynamic patterns of CO 2 level is utilized to modulate the ventilation rate in real-time and also reduce the energy consumption. The proposed controller reduced the HVAC fan’s energy consumption by 51.4% and provide ventilation as needed per the ASHRAE standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating Oxidation of Carbon Surfaces by Atomic Oxygen Coupled with a Finite Rate Oxidation Model

Oxidation is a prominent factor in degradation of carbon based ablative materials at high temperatures, resulting in mass loss and material recession through chemical and mechanical erosion. In this paper, a finite rate carbon oxidation model coupled with surface recession is implemented in the Porous Ablation and Thermal Response (Panther) software to investigate carbon oxidation by atomic oxygen over a range of temperatures and pressures. Panther is utilized to investigate the finite rate oxidation model proposed by Swaminathan-Gopalan et al. at conditions of higher pressure and flux relative to the experiments it was built on.

Kirmanoglu, Kaan K.↗

A digitally implemented communications experiment utilizing the communications technology satellite, Hermes

Developments which will reduce the costs associated with the distribution of satellite services are considered with emphasis on digital communication link implementation. A digitally implemented communications experiment (DICE) which demonstrates the flexibility and efficiency of digital transmission of television video and audio, telephone voice, and high-bit-rate data is described. The utilization of the DICE system in a full duplex teleconferencing mode is addressed. Demonstration teleconferencing results obtained during the conduct of two sessions of the 7th AIAA Communication Satellite Systems Conference are discussed. Finally, the results of link characterization tests conducted to determine (1) relationships between the Hermes channel 1 EIRP and DICE model performance and (2) channel spacing criteria for acceptable multichannel operation, are presented.

Jackson, H. D.↗

Residual thermal and moisture influences on the strain energy release rate analysis of local delaminations from matrix cracks

An analysis utilizing laminated plate theory is developed to calculate the strain energy release rate associated with local delaminations originating at off-axis, single ply, matrix cracks in laminates subjected to uniaxial loads. The analysis includes the contribution of residual thermal and moisture stresses to the strain energy released. Examples are calculated for the strain energy release rate associated with local delaminations originating at 90 degrees and angle-ply (non-90 degrees) matrix ply cracks in glass epoxy and graphite epoxy laminates. The solution developed may be used to assess the relative contribution of mechanical, residual thermal, and moisture stresses on the strain energy release rate for local delamination for a variety of layups and materials.

Obrien, T. K.↗

High-Rate Strong-Signal Quantum Cryptography

Several quantum cryptosystems utilizing different kinds of nonclassical lights, which can accommodate high intensity fields and high data rate, are described. However, they are all sensitive to loss and both the high rate and the strong-signal character rapidly disappear. A squeezed light homodyne detection scheme is proposed which, with present-day technology, leads to more than two orders of magnitude data rate improvement over other current experimental systems for moderate loss.

Yuen, Horace P.↗

Co-transport of water and p-xylene through carbon molecular sieve membranes

Carbon molecular sieve (CMS) materials are a potential candidate for scalable and high-performance reverse osmosis membranes due to their impressive chemical and thermal stabilities. Moreover, they have the potential to enable impressive rejections of small neutral solutes from water based on their known ability to separate small organic molecules. CMS has been extensively examined for gas and organic solvent separations, but the transport of organic and aqueous mixtures through CMS microstructures is poorly understood. In this work, we investigated the sorption, diffusion, and permeation behavior of organic compounds and water in poly(vinylidene fluoride)(PVDF)-derived CMS (PVDF-CMS). Experimental observations of diffusion, sorption, and permeation shows how the properties of penetrants such as polarity and molecular size affect the transport rates and selectivity. These basic transport and sorption parameters are utilized in sorption-diffusion models to permeation rates of water-organic mixtures in CMS membranes. The transport of water and p-xylene in CMS was experimentally confirmed to follow the sorption-diffusion mechanism. The sorption-diffusion model ideal permselectivity indicates that the CMS is p-xylene selective over water. Water/p-xylene mixture permeation experiments revealed an increased selectivity of p-xylene over water, thus providing tentative evidence for a competitive sorption-selective separation mechanism. Furthermore, this work suggests that CMS membranes exhibit organic-permeable separation properties in water/organic separations. The results presented here highlight the potential for the removal of dilute organics in water via CMS pervaporation membranes.

02 PETROLEUM↗

Frequency modulation television analysis: Threshold impulse analysis

A computer program is developed to calculate the FM threshold impulse rates as a function of the carrier-to-noise ratio for a specified FM system. The system parameters and a vector of 1024 integers, representing the probability density of the modulating voltage, are required as input parameters. The computer program is utilized to calculate threshold impulse rates for twenty-four sets of measured probability data supplied by NASA and for sinusoidal and Gaussian modulating waveforms. As a result of the analysis several conclusions are drawn: (1) The use of preemphasis in an FM television system improves the threshold by reducing the impulse rate. (2) Sinusoidal modulation produces a total impulse rate which is a practical upper bound for the impulse rates of TV signals providing the same peak deviations. (3) As the moment of the FM spectrum about the center frequency of the predetection filter increases, the impulse rate tends to increase. (4) A spectrum having an expected frequency above (below) the center frequency of the predetection filter produces a higher negative (positive) than positive (negative) impulse rate.

Hodge, W. H.↗

Nickel-hydrogen battery state of charge during low rate trickle charging

The NASA AXAF-I program requires high battery state of charge at launch. Traditional approaches to providing high state of charge, during prelaunch operations, require significant battery cooling. The use of active cooling, in the AXAF-I prelaunch environment, was considered and proved to be difficult to implement and very expensive. Accordingly alternate approaches were considered. An approach utilizing adiabatic charging and low rate trickle charge, was investigated and proved successful.

Lurie, C.↗