Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “usability testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Postmortem and Antemortem Forensic Assessment of Pediatric Fracture Healing from Radiographs and Machine Learning Classification

A timeline of pediatric bone healing using fracture healing characteristics that can be assessed solely using radiographs would be practical for forensic casework, where the fracture event may precede death by days, months, or years. However, the dating of fractures from radiographs is difficult, imprecise, and lacks consensus, as only a few aspects of the healing process are visible on radiographs. Multiple studies in both the clinical and forensic literature have attempted to develop a usable scale to assess pediatric bone healing on radiographs using various healing characteristics. In contrast to the orthopedic definition, a fracture in forensic casework is only considered to be healed when the area around the fracture has been remodeled to the point that the fracture is difficult to detect on a radiograph or on the surface of the bone itself, a process that can take several years. We subjectively assessed visible characteristics of healing in radiograms of fractures occurring in 942 living children and adolescents. By dividing these assessments into learning and test (validation) sets, the accuracy of a newly proposed fracture healing scale was compared to a previous study. Two machine learning models were used to test predictions of the new scale. All three models produced similar estimates with substantial imprecision. Results corroborate the Malone model with an independent dataset and support the efficacy of using less complex models to estimate fracture age in children.

60 APPLIED LIFE SCIENCES↗

A Terminal Area Icing Remote Sensing System

NASA and the National Center for Atmospheric Research (NCAR) have developed an icing remote sensing technology that has demonstrated skill at detecting and classifying icing hazards in a vertical column above an instrumented ground station. This technology is now being extended to provide volumetric coverage surrounding an airport. With volumetric airport terminal area coverage, the resulting icing hazard information will be usable by aircrews, traffic control, and airline dispatch to make strategic and tactical decisions regarding routing when conditions are conducive to airframe icing. Building on the existing vertical pointing system, the new method for providing volumetric coverage will utilize cloud radar, microwave radiometry, and NEXRAD radar. This terminal area icing remote sensing system will use the data streams from these instruments to provide icing hazard classification along the defined approach paths into an airport. Strategies for comparison to in-situ instruments on aircraft and weather balloons for a planned NASA field test are discussed, as are possible future applications into the NextGen airspace system.

aircraft icing↗

Highly Integrated WBG Power Module for Next Generation Plug-In Vehicles

Current inverter technologies used in electric vehicles (EVs) are bulky, heavy, and expensive. The performance of the inverter is also limited by the traditional Si-based semiconductor and packaging technology. These constraints are responsible for extra weight and volume in the vehicle that reduces the driving range along with usable space within the vehicle. Moreover, operating temperature restrictions, and boundaries on the inverter location within the vehicle drastically reduces the inverter performance. Thus an improved inverter design is required for next generation electric vehicles. The objective of this project was to research, develop and demonstrate a highly integrated WBG power module targeting the next generation of plugin hybrid electric vehicles (PHEVs). This power module needed to be functionally and mechanically optimized for General Motors (GM) traction inverter architecture. General Motors was the prime contractor, led the project, and oversaw the design, build, and test of the integrated power module. Virginia Polytechnic Institute and State University (VT) performed modeling and simulation tasks as well as power module design support. Monolith Semiconductor, Inc provided SiC dies and consulted on devices for the inverter. Oak Ridge National Laboratory (ORNL) performed power module technology evaluations, design evaluations of interconnect options, and performed material analysis and cross-sectioning of die activities.

33 ADVANCED PROPULSION SYSTEMS↗

A Comparison of the AVS-9 and the Panoramic Night Vision Goggle During Rotorcraft Hover and Landing

The purpose of this flight test was to measure any differences in pilot-vehicle performance and pilot opinion between the use of the current generation AVS-9 Night Vision Goggle and one variant of the prototype Panoramic Night Vision Goggle (the PNV.GII). The PNVGII has more than double the horizontal field-of-view of the AVS-9, but reduced image quality. The flight path of the AH-1S helicopter was used as a measure of pilot-vehicle performance. Also recorded were subjective measures of flying qualities, physical reserves of the pilot, situational awareness, and display usability. Pilot comment and data indicate that the benefits of additional FOV with the PNVGIIs are to some extent negated by the reduced image quality of the PNVGIIs.

Szoboszlay, Zoltan↗

Detecting Process Equipment Failures Using Acoustic Data and Machine Learning

Nuclear power plant (NPP) process equipment such as fans, motors, valves, and pumps generate frequent or continuous noise, and deviations from the normal operational sounds made by this equipment can indicate potential issues. These deviations can be identified via automated acoustic anomaly detection, which involves using acoustic sensors (i.e., microphones) alongside detection algorithms to continuously monitor for changes in acoustic signatures. This task is made challenging by the substantial background noise that exists, such as operators opening and closing doors, manipulating valves, and conversing—in addition to typical plant noises. In collaboration with a nuclear power utility partner, this effort assessed the efficacy of acoustic anomaly detection when using a specific acoustic sensor that compresses data into a fixed set of features that are transferable over a standard Internet of Things communication protocol, thereby improving usability but potentially degrading detection performance. Two methods of performing automated acoustic anomaly detection were evaluated: one-class support vector machine (OC-SVM) and isolation forest (iForest). To enable the use of high-quality acoustic data encompassing both normal and anomalous conditions, the study utilized the publicly available Malfunctioning Industrial Machine Investigation and Inspection dataset, which includes real measured acoustic sensor data for a range of equipment types, model numbers, and signal-to-noise ratios (SNRs), along with a benchmark set of detection results. Using this dataset, the methods were tested and then compared against the benchmark results. The results indicated that although the specific acoustic sensor did not enable as rich a feature set extraction, the proposed methods with the limited feature set performed just as well. This provides solid justification for both the methods and the use of the proposed acoustic sensor.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Bench-Scale Electrolytic Dissolution of Quarter-Scale FCA Cans

In 2016, the Savannah River National Laboratory (SRNL) led, in support of and under sponsorship of the Department of Energy’s National Nuclear Security Administration (DOE/NNSA) Office of Material Management and Minimization (M3), the removal and transfer of the plutonium based Fast Critical Assembly (FCA) fuel from the Japan Atomic Energy Agency (JAEA) Tokai facility to the Savannah River Site (SRS). The team also included JAEA, multiple organizations in Savannah River Nuclear Solutions (SRNS), International Nuclear Services, and many other entities. The FCA fuel removal project completion was a key deliverable for M3 to the 2016 Nuclear Security Summit and constituted the largest inventory of weapons-usable plutonium removed under the nonproliferation program. The FCA materials consist of thousands of stainless steel (SS) clad plates and hundreds of SS clad rods. The FCA fuel elements were packaged in a carrier can and stored at SRS pending disposition of the fuel. Following an assessment of candidate disposition options, SRNS identified electrolytic dissolution (ED) as the most promising disposition option for the FCA plates and their preferred option was endorsed by DOE. This option entails electrochemically dissolving the entire FCA carrier can with fuel elements and was based on bench-scale laboratory testing and historical work on processing SS-clad and zirconium-clad uranium-based fuel in the H-Canyon electrolytic dissolver (last operated in 1980). The FCA plate consists of a plutonium-aluminum metal alloy core hermitically sealed in SS cladding.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application Reuse Library for Software, Requirements, and Guidelines

Better designs are needed for expert systems and other operations automation software, for more reliable, usable and effective human support. A prototype computer-aided Application Reuse Library shows feasibility of supporting concurrent development and improvement of advanced software by users, analysts, software developers, and human-computer interaction experts. Such a library expedites development of quality software, by providing working, documented examples, which support understanding, modification and reuse of requirements as well as code. It explicitly documents and implicitly embodies design guidelines, standards and conventions. The Application Reuse Library provides application modules with Demo-and-Tester elements. Developers and users can evaluate applicability of a library module and test modifications, by running it interactively. Sub-modules provide application code and displays and controls. The library supports software modification and reuse, by providing alternative versions of application and display functionality. Information about human support and display requirements is provided, so that modifications will conform to guidelines. The library supports entry of new application modules from developers throughout an organization. Example library modules include a timer, some buttons and special fonts, and a real-time data interface program. The library prototype is implemented in the object-oriented G2 environment for developing real-time expert systems.

Malin, Jane T.↗

Static and Turn-on Switching Characteristics of 4H-Silicon Carbide SITs to 200 deg C

Test results are presented for normally-off 4H-SiC Static Induction Transistors (SITs) intended for power switching and are among the first normally-off such devices realized in SiC. At zero gate bias, the gate p-n junction depletion layers extend far enough into the conduction channel to cut off the channel. Application of forward gate bias narrows the depletion regions, opening up the channel to conduction by majority carriers. In the present devices, narrow vertical channels get pinched by depletion regions from opposite sides. Since the material is SiC, the devices are usable at temperatures above 150 C. Static curve and pulse mode switching observations were done at selected temperatures up to 200 C on a device with average static characteristics from a batch of similar devices. Gate and drain currents were limited to about 400 mA and 3.5 A, respectively. The drain voltage was limited to roughly 300 V, which is conservative for this 600 V rated device. At 23 C, 1 kW, or even more, could be pulse mode switched in 65 ns (10 to 90 percent) into a 100 load. But at 200 C, the switching capability is greatly reduced in large part by the excessive gate current required. Severe collapse of the saturated drain-to-source current was observed at 200 C. The relation of this property to channel mobility is reviewed.

Niedra, Janis M.↗

9.3 Microns: Toward a Next-Generation CO2 Laser for Particle Accelerators

We present realistic theoretical predictions of the performance of the next-generation long-wave infrared (LWIR) laser for advanced particle acceleration research at the Accelerator Test Facility (ATF) of Brookhaven National Laboratory. Two upgrades are planned for the present ATF CO2 laser, which currently produces up to 5 TW peak power in 2 ps pulses at 9.2 μm. For the first upgrade, the deployment of a ten-millijoule solid-state seed laser at 9.3 μm will reduce the pulse duration 4 times, to 500 fs, and increase the peak power to 15 TW. The second upgrade will be the implementation of the postcompression of this pulse. This will reduce the pulse duration to three optical cycles (100 fs) and increase the usable peak power to 25 TW.

43 PARTICLE ACCELERATORS↗

Data reduction software for LORAN-C flight test evaluation

A set of programs designed to be run on an IBM 370/158 computer to read the recorded time differences from the tape produced by the LORAN data collection system, convert them to latitude/longitude and produce various plotting input files are described. The programs were written so they may be tailored easily to meet the demands of a particular data reduction job. The tape reader program is written in 370 assembler language and the remaining programs are written in standard IBM FORTRAN-IV language. The tape reader program is dependent upon the recording format used by the data collection system and on the I/O macros used at the computing facility. The other programs are generally device-independent, although the plotting routines are dependent upon the plotting method used. The data reduction programs convert the recorded data to a more readily usable form; convert the time difference (TD) numbers to latitude/longitude (lat/long), to format a printed listing of the TDs, lat/long, reference times, and other information derived from the data, and produce data files which may be used for subsequent plotting.

Fischer, J. P.↗

Experimental landings in a spoiler-equipped light aircraft.

This report presents the results of a flight test program to determine the effects on landings of wide variations in approach path angle and approach airspeed for different kinds of piloting technique. Over 400 landings were made at approach speeds from 60 to 120 mph and approach path angles from 3 to 18 deg. Several variations of pilot technique involving different operations of the throttle/spoiler control were investigated. It is shown that very large ranges of airspeed and approach path angle can be accommodated with rather moderate penalties in landing distance and difficulty. With the spoiler-equipped aircraft, the best approach speeds are considerably higher than would be usable without spoilers, and approach path angles can be used which are far beyond those normally possible without spoilers.

Seckel, E.↗

Launch vehicle effluent measurements during the August 20, 1977, Titan 3 launch at Air Force Eastern Test Range

Airborne effluent measurements within the launch cloud and visible and infrared measurements of cloud physical behavior are discussed. Airborne effluent measurements include concentrations of HCl, Cl2, NO, NOX, and particulates as a function of time during each sampling pass through the exhaust cloud. The particle size distribution was measured for each pass through the cloud. Mass concentration as a function of particle diameter was measured over the size range of 0.05- to 25 micron diameter, and particle number density was measured as a function of diameter over a size range of 0.5 to 7.5 micron. Effluent concentrations in the cloud ranged from about 30 ppm several minutes after launch to about 1 to 2 ppm at 100 minutes. Maximum Cl2 concentrations were about 40 to 55 ppb and by 20 minutes were less than 1.0 ppb. A tabulated listing of the airborne data is given in the appendix. Usable cloud imaging data were limited to the first 16 minutes after launch.

Woods, D. C.↗

A Quantum Dot Nanobiosensor for Rapid Detection of Botulinum Neurotoxin Serotype E

Botulinum neurotoxins (BoNTs) are potent toxins produced by Clostridium bacteria that are responsible for the illness botulism and are listed as bioterrorism agents. BoNT serotype E (BoNT/E) is one of four BoNT serotypes that cause human botulism and is the second most frequent cause of foodborne botulism. Rapid detection and discrimination of BoNT serotypes implicated in human disease are critical for ensuring timely treatment of patients and identifying sources of toxins, but there have been few reported detection methods for BoNT/E and even fewer methods usable for BoNT serotyping. We report a nanobiosensor based on Forster resonance energy transfer (FRET) between semiconductor nanocrystals (quantum dots, QDs) and dark quencher-labeled peptide probes to detect biologically active BoNT/E in aqueous media. The peptide probes contain a specific cleavage site for active BoNT/E. QD photoluminescence, which changes intensity due to FRET when the peptide probe is cleaved, was used to indicate toxin presence and quantity. The detection of a BoNT/E light chain (LcE) and holotoxin was observed within 3 h. The limits of detection were 0.02 and 2 ng/mL for LcE and holotoxin, respectively. The nanobiosensor shows good specificity toward the target in tests with nontarget BoNT serotypes. The high sensitivity, simple operation, short detection time, and ability to be used in parallel with probes developed for other BoNT serotypes indicate that the nanobiosensor will be useful for rapid BoNT/E detection and serotype discrimination in food analysis.

botulinum neurotoxin E↗

Development of the NACA slot-lip aileron

An investigation of the undesirable delayed action, or lag, of the spoiler-type lateral control device led to the development of the NACA slot-lip aileron. The tests were made in the 7- by 10-foot wind tunnel with a 4- by 8-foot wing hinged at the tunnel jet boundary and taken of the motion of the control device under test and of the resulting wing motion. First, the lag, as affected by the fore-and-aft location of retractable ailerons or spoilers was determined. The lag was found to increase regularly as the spoiler was moved from the rear of the wing toward the front. Then a combination of spoilers and fixed slot was developed that, with the spoiler retracting into the forward part of the slot, reduced the time lag to a negligible value. In addition, an arrangement was developed using a hinged aileron-type flap as the upper portion, or lip, of a slot through the wing. This arrangement appears to be usable as a form of lateral control device that shows promise of giving improved control and stability at the high angles of attack through stall, with negligible lag, low control forces, and relatively simple construction.

Weick, Fred E↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

The NASA Space Radiation Laboratory

The Space Radiation Element (SRE) of the Human Research Program (HRP) aims to establish a robust biospecimen and tissue sharing collection (BTSC) to improve sample collection, tracking, access, distribution, and usability to maximize scientific return with intention. Future missions to the Moon, Mars, and beyond will require the appropriate characterization and mitigation of the many of the health risks associated with cosmic radiation exposure. An ongoing partnership between the National Aeronautics and Space Agency (NASA) and the Office of Science for the U.S. Department of Energy (DOE) has established the NASA Space Radiation Laboratory (NSRL) at the DOE Brookhaven National Laboratory (BNL) to create a space radiation ground-analog. NSRL provides the capability to use simulated space radiation with high energy ion beams for assessment of biological outcomes relevant space radiation risks as well as electronics testing for avionics safety. Current NSRL irradiation capabilities include a variety of exposure variables available for experimental needs: - Up to approximately 10 Gy/min dose-rates with a 20 × 20 cm 2 beam area. - Down to several hundred particles within a 60 × 60 cm 2 beam area. - Dose fractionation across multiple days is also possible. - For most radiobiology experiments the exposure structure, referred to as “spills”, has a 4 second repetition time where ions are extracted uniformly during a 0.3-0.4 second spill, followed by a ~3.6 second recovery time when the beam is off. - Both single or mixed-beam field irradiations are possible including a full 33-beam GCRSim and 6-beam SimGCRSim. Biological experiment capabilities: Two labs for Cell/tissue culture procedures can be conducted in two lab spaces with a separate lab available for sample processing that contains two chemical fume hoods. Sixteen fully equipped cell culture laboratories are available in the NSRL’s Long Term Support area in the Medical Building. The current vivarium configuration can support approximately 8,000 rodents/year for animal-based experiments. The NSRL area animal husbandry system includes five caging racks with 48 spaces in each coupled to a ventilation/filtration system in largest room, and two smaller rooms with conventional caging systems. Schedule: The NSRL is nominally open for experiment scheduling during three runs per year; Spring (March – May), Summer (May - June), and Fall (Sept – Nov). NASA funding is not required for biological and electronic testing experiments at the NSRL.

Jason M Weeks↗

Tissue-mimicking phantoms for performance evaluation of photoacoustic microscopy systems

Phantom-based performance test methods are critically needed to support development and clinical translation of emerging photoacoustic microscopy (PAM) devices. While phantoms have been recently developed for macroscopic photoacoustic imaging systems, there is an unmet need for well-characterized tissue-mimicking materials (TMMs) and phantoms suitable for evaluating PAM systems. Our objective was to develop and characterize a suitable dermis-mimicking TMM based on polyacrylamide hydrogels and demonstrate its utility for constructing image quality phantoms. TMM formulations were optically characterized over 400–1100 nm using integrating sphere spectrophotometry and acoustically characterized using a pulse through-transmission method over 8–24 MHz with highly confident extrapolation throughout the usable band of the PAM system. This TMM was used to construct a spatial resolution phantom containing gold nanoparticle point targets and a penetration depth phantom containing slanted tungsten filaments and blood-filled tubes. These phantoms were used to characterize performance of a custom-built PAM system. The TMM was found to be broadly tunable and specific formulations were identified to mimic human dermis at an optical wavelength of 570 nm and acoustic frequencies of 10–50 MHz. Imaging results showed that tungsten filaments yielded 1.1–4.2 times greater apparent maximum imaging depth than blood-filled tubes, which may overestimate real-world performance for vascular imaging applications. Nanoparticles were detectable only to depths of 120–200 µm, which may be due to the relatively weaker absorption of single nanoparticles vs. larger targets containing high concentration of hemoglobin. The developed TMMs and phantoms are useful tools to support PAM device characterization and optimization, streamline regulatory decision-making, and accelerate clinical translation.

Hsu, Hsun-Chia↗