Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transmissive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Denoising atomic resolution 4D scanning transmission electron microscopy data with tensor singular value decomposition

Tensor singular value decomposition (SVD) is a method to find a low-dimensional representation of data with meaningful structure in three or more dimensions. Here, tensor SVD has been applied to denoise atomic-resolution 4D scanning transmission electron microscopy (4D STEM) data. On data simulated from a SrTiO 3 [100] perfect crystal and a Si [110] edge dislocation, tensor SVD achieved an average peak signal-to-noise ratio (PSNR) of ~40 dB, which matches or exceeds the performance of other denoising methods, with processing times at least 100 times shorter. On experimental data from SrTiO 3 [100] and LiZnSb [11 2 ¯ 0]/GaSb [110] samples, tensor SVD denoises multiple GB 4D STEM data sets in ten minutes on a typical personal computer. Denoising with tensor SVD improves both convergent beam electron diffraction patterns and virtual-aperture annular dark field images.

36 MATERIALS SCIENCE↗

Identification and correction of temporal and spatial distortions in scanning transmission electron microscopy

Scanning transmission electron microscopy (STEM) has become the technique of choice for quantitative characterization of atomic structure of materials, where the minute displacements of atomic columns from high-symmetry positions can be used to map strain, polarization, octahedra tilts, and other physical and chemical order parameter fields. The latter can be used as inputs into mesoscopic and atomistic models, providing insight into the correlative relationships and generative physics of materials on the atomic level. However, these quantitative applications of STEM necessitate understanding the microscope induced image distortions and developing the pathways to compensate them both as part of a rapid calibration procedure for in situ imaging, and the post-experimental data analysis stage. Here, we explore the spatiotemporal structure of the microscopic distortions in STEM using multivariate analysis of the atomic trajectories in the image stacks. Based on the behavior of principal component analysis (PCA), we develop the Gaussian process (GP)-based regression method for quantification of the distortion function. The limitations of such an approach and possible strategies for implementation as a part of in-line data acquisition in STEM are discussed. Here, the analysis workflow is summarized in a Jupyter notebook that can be used to retrace the analysis and analyze the reader's data.

36 MATERIALS SCIENCE↗

Relation between sampling, sensitivity and precision in strain mapping using the Geometric Phase Analysis method in Scanning Transmission Electron Microscopy

The sensitivity and the precision of the Geometric Phase Analysis (GPA) method for strain characterization is a topic widely discussed in the literature and is usually difficult to quantify. Indeed, the GPA precision is intricately linked to the resolution of the strain maps defined when masking the periodic reflections in Fourier space. In this study an additional parameter, sampling, is proposed to be analyzed regarding the precision of GPA by developing the concept of a phase noise in the GPA equations. Both experimentally and theoretically, the following article demonstrates how the precision, and the sensitivity of the GPA method is improved when using a larger pixel spacing to record an electron micrograph in Scanning Transmission Electron Microscopy (STEM). In conclusion, the counterintuitive concept of increasing the field of view to improve the GPA precision results in an extension of the application of strain characterization methods in STEM towards low deformation levels.

47 OTHER INSTRUMENTATION↗

Direct observation of oxygen vacancy ordering evolution in cerium oxide at varying concentrations via high-resolution transmission electron microscopy

Under illumination by a 300 keV electron beam, oxygen vacancy ordering structures are induced within cerium oxide grains. Here, our high-resolution transmission electron microscopy (HRTEM) study, supported by image simulation, reveals the evolution of these structures as vacancy concentration increases. The observed fluorite-type superlattice structures are identified as CeO 1.825 , CeO 1.75 , Ce 2 O 3 , displaying a gradient in oxygen vacancy concentration moving away from the grain surface. Correspondingly, the structural sequence transitions from Ce 2 O 3 to CeO 1.75 and then to CeO 1.825 . Without the constraints of surrounding grains, fluorite-type Ce 2 O 3 nanocrystals show a preference for transformation into an A-type trigonal structure. Notably, at temperatures up to 200°C, only the perfect fluorite structure is observed. Structural models were validated through both [110] and [001] projections. Our findings further confirm lattice expansion associated with local oxygen vacancy enrichment, which can be compensated by the formation of stacking faults, where a {111} oxygen plane is lost at defect sites.

Cerium oxide↗

Transmission electron microscopy with in-situ ion irradiation: Facilities and community

Whilst there is a clear scientific and technological need for the technical capabilities of transmission electron microscopes with in-situ ion irradiation, it also requires a collaborative community of international researchers to support such facilities in successfully meeting this demand. Instruments of this type serve to provide fundamental understanding of the mechanisms which drive changes in materials important to nuclear fission and fusion energy, the semiconductor industry, quantum information systems, space travel, astronomy, geology and many more applications. As these areas continue to evolve and the instrumentation possibilities expand, the capacity of in-situ ion irradiation facilities must also develop hand-in-hand with the user community to deliver an ever-greater diversity of high-fidelity extreme-environment experimentation. Future directions for the field, such as miniaturization from MEMS/microfluidic devices and advanced controls with ML-based analysis, continuously emerge to advance both the hardware and software which support the coupling of TEMs with ion beams. This review sets out to provide up-to-date insights into the community and advancement of current, and development of future, facilities which have the potential to further unlock access to the nanoscale exploration of coupled extreme environments crucial to many of the important science and engineering challenges we face today.

In-situ irradiation↗

Deep Learning Segmentation of Complex Features in Atomic-Resolution Phase-Contrast Transmission Electron Microscopy Images

Phase-contrast transmission electron microscopy (TEM) is a powerful tool for imaging the local atomic structure of materials. TEM has been used heavily in studies of defect structures of two-dimensional materials such as monolayer graphene due to its high dose efficiency. However, phase-contrast imaging can produce complex nonlinear contrast, even for weakly scattering samples. It is, therefore, difficult to develop fully automated analysis routines for phase-contrast TEM studies using conventional image processing tools. For automated analysis of large sample regions of graphene, one of the key problems is segmentation between the structure of interest and unwanted structures such as surface contaminant layers. In this study, we compare the performance of a conventional Bragg filtering method with a deep learning routine based on the U-Net architecture. We show that the deep learning method is more general, simpler to apply in practice, and produces more accurate and robust results than the conventional algorithm. We provide easily adaptable source code for all results in this paper and discuss potential applications for deep learning in fully automated TEM image analysis.

47 OTHER INSTRUMENTATION↗

An Automated Scanning Transmission Electron Microscope Guided by Sparse Data Analytics

Abstract Artificial intelligence (AI) promises to reshape scientific inquiry and enable breakthrough discoveries in areas such as energy storage, quantum computing, and biomedicine. Scanning transmission electron microscopy (STEM), a cornerstone of the study of chemical and materials systems, stands to benefit greatly from AI-driven automation. However, present barriers to low-level instrument control, as well as generalizable and interpretable feature detection, make truly automated microscopy impractical. Here, we discuss the design of a closed-loop instrument control platform guided by emerging sparse data analytics. We hypothesize that a centralized controller, informed by machine learning combining limited a priori knowledge and task-based discrimination, could drive on-the-fly experimental decision-making. This platform may unlock practical, automated analysis of a variety of material features, enabling new high-throughput and statistical studies.

47 OTHER INSTRUMENTATION↗

Use of Transmission Electron Microscopy for Analysis of Aerosol Particles and Strategies for Imaging Fragile Particles

For over 25 years, transmission electron microscopy (TEM) has provided a method for the study of aerosol particles with sizes from below the optical diffraction limit to several microns, resolving the particles as well as smaller features. The wide use of this technique to study aerosol particles has contributed important insights about environmental aerosol particle samples and model atmospheric systems. TEM produces an image that is a 2D projection of aerosol particles that have been impacted onto grids and, through associated techniques and spectroscopies, can contribute additional information such as the determination of elemental composition, crystal structure, and 3D particle structures. Soot, mineral dust, and organic/inorganic particles have all been analyzed using TEM and spectroscopic techniques. TEM, however, has limitations that are important to understand when interpreting data including the ability of the electron beam to damage and thereby change the structure and shape of particles, especially in the case of particles composed of organic compounds and salts. In this paper, we concentrate on the breadth of studies that have used TEM as the primary analysis technique. Another focus is on common issues with TEM and cryogenic-TEM. Insights for new users on best practices for fragile particles, that is, particles that are easily susceptible to damage from the electron beam, with this technique are discussed. Tips for readers on interpreting and evaluating the quality and accuracy of TEM data in the literature are also provided and explained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolving Nanoscale Processes during Carbon Mineralization Using Identical Location Transmission Electron Microscopy

Basalt reservoirs offer the potential for carbon mineralization, aiding in achieving net-zero emissions. However, debates persist about microscopic crystallization mechanisms due to limited characterization techniques under high-temperature and pressure conditions. By using Identical Location Transmission Electron Microscopy (IL-TEM) and cryo-TEM, this study reveals nanoscale interfacial carbonation processes of forsterite and diopside nanoparticles in water-saturated supercritical carbon dioxide under realistic reservoir conditions. Further, both minerals undergo preferential metal cation dissolution into a thin water film, forming porous Si-rich amorphous layers, supporting the leached layer mechanism as the dominant mineral reactivity process. Diopside’s amorphous layer has lower porosity and growth rate relative to forsterite, likely related to the connectivity of silicate tetrahedra. Kinetically favorable nesquehonite and aragonite nanocrystals form on the amorphous layers. These findings support the development of accurate reservoir simulations and help enable commercial-scale carbon storage deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recreating Fuel Cell Catalyst Degradation in Aqueous Environments for Identical-Location Scanning Transmission Electron Microscopy Studies

The recent surge in interest of proton exchange membrane fuel cells (PEMFCs) for heavy-duty vehicles increases the demand on the durability of oxygen reduction reaction electrocatalysts used in the fuel cell cathode. This prioritizes efforts aimed at understanding and subsequently controlling catalyst degradation. Identical-location scanning transmission electron microscopy (IL-STEM) is a powerful method that enables precise characterization of degradation processes in individual catalyst nanoparticles across various stages of cycling. Recreating the degradation processes that occur in PEMFC membrane electrode assemblies (MEAs) within the aqueous cell used for IL-STEM experiments is vital for generating an accurate understanding of these processes. In this work, we investigate the type and degree of catalyst degradation achieved by cycling in an aqueous cell compared to a PEMFC MEA. While significant degradation is observed in IL-STEM experiments performed on a traditional Pt catalyst using the standard accelerated stress test potential window (0.6-0.95 VRHE), degradation of a PtCo catalyst designed for heavy-duty vehicle use is very limited compared to that observed in MEAs. We therefore explore various experimental parameters such as temperature, acid type, acid concentration, ionomer content, and potential window to identify conditions that reproduce the degradation observed in MEAs. We find that by extending the cycling potential window to 0.4-1.0 V RHE in an electrolyte containing Pt ions, the degraded particle size distribution and alloy composition better match that observed in MEAs. In particular, these conditions increase the relative contribution of Ostwald ripening, which appears to play a more significant role in the degradation of larger alloy particles supported on high-surface-area carbons than coalescence. Results from this work highlight the potential for discrepancies between ex situ aqueous experiments and MEA tests. While different catalysts may require a unique modification to the AST protocol, strategies provided in this work enable future in situ and identical-location experiments that will play an important role in the development of robust catalysts for heavy-duty vehicle applications.

30 DIRECT ENERGY CONVERSION↗

Visualizing Oxidation Mechanisms in Few-Layered Black Phosphorus via In Situ Transmission Electron Microscopy

Layered two-dimensional (2D) black phosphorus (BP) exhibits novel semiconducting properties including a tunable bandgap and high electron mobility. However, the poor stability of BP in ambient environment severely limits potential for application in future electronic and optoelectronic devices. While passivation or encapsulation of BP using inert materials/polymers has emerged as a plausible solution, a detailed fundamental understanding of BP's reaction with oxygen is imperative to rationally advance its use in applications. Here, we use in situ environmental transmission electron microscopy to elucidate atomistic structural changes in mechanically exfoliated few-layered BP during exposure to varying partial pressures of oxygen. An amorphous oxide layer is seen on the actively etching BP edges, and the thickness of this layer increases with increasing oxygen partial pressure, indicating that oxidation proceeds via initial formation of amorphous P x O y species which sublime to result in the etching of the BP crystal. We observe that while few-layered BP is stable under the 80 kV electron beam (e-beam) in vacuum, the lattice oxidizes and degrades at room temperature in the presence of oxygen only in the region under the e-beam. The oxidative etch rate also increases with increasing e-beam dosage, suggesting the presence of an energy barrier for the oxidation reaction. Preferential oxidative etching along the [0 0 1] and [0 0 1] crystallographic directions is observed, in good agreement with density functional theory calculations showing favorable thermodynamic stability of the oxidized BP (0 0 $\bar{1}$) planes compared to the (1 0 0) planes. Finally, we expect the atomistic insights and fundamental understanding obtained here to aid in the development of novel approaches to integrate BP in future applications.

2D materials↗

Deciphering the Distribution and Crystal-Chemical Environment of Arsenic, Lead, Silica, Phosphorus, Tin, and Zinc in a Porous Ferrihydrite Grain Using Transmission Electron Microscopy and Atom Probe Tomography

Here the interaction of contaminants and nutrients with soil constituents is controlled by processes in intergranular and intragranular pore spaces of organic matter or/and common secondary minerals such as ferrihydrite, ~Fe 3+ 10 O 14 (OH) 2 . This contribution shows that distribution and clustering of the contaminants As, P, Pb, Si, Sn, and Zn in a porous ferrihydrite grain is greatly affected by the heterogeneous size distribution and chemical composition of the pores as well as the ability of their polyhedra to polymerize with the same type of polyhedron. Transmission electron microscopy (TEM) and atom probe tomography (APT) studies are conducted on focused ion beam (FIB) sections extracted from a porous ferrihydrite grain from the smelter-impacted topsoil in Sudbury, Ontario, Canada. The ferrihydrite grain has pore spaces ranging in diameter from tens to hundreds of nanometers. TEM and scanning-TEM studies indicate that the surfaces of the pore walls are enriched in Si. APT data in conjunction with First Near Neighbor (1NN) analyses indicate different degrees of clustering of Pb, As, Sn, Zn, Si, and P within the sample and selected domains. Careful evaluations of 3D atomic plots and 1NN distances indicates the occurrence of polymerized arsenite-, silica-, Sn-, and Zn-polyhedra within pore spaces of the ferrihydrite. Deciphering adsorption, polymerization, and nucleation processes in porous Fe-(hydr)oxides and other soil constituents requires multianalytical approaches and, in this regard, we discuss the advantages and disadvantages of the combination of TEM and APT for characterizing complex environmental samples at the atomic to nanometer scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding Stabilization in Nanoporous Intermetallic Alloy Anodes for Li-Ion Batteries Using Operando Transmission X-ray Microscopy

Tin-based alloying anodes are exciting due to their high energy density. Unfortunately, these materials pulverize after repetitive cycling due to the large volume expansion during lithiation and delithiation; both nanostructuring and intermetallic formation can help alleviate this structural damage. Here, these ideas are combined in nanoporous antimony–tin (NP-SbSn) powders, synthesized by a simple and scalable selective-etching method. The NP-SbSn exhibits bimodal porosity that facilitates electrolyte diffusion; those void spaces, combined with the presence of two metals that alloy with lithium at different potentials, further provide a buffer against volume change. This stabilizes the structure to give NP-SbSn good cycle life (595 mAh/g after 100 cycles with 93% capacity retention). Operando transmission X-ray microscopy (TXM) showed that during cycling NP-SbSn expands by only 60% in area and then contracts back nearly to its original size with no physical disintegration. The pores shrink during lithiation as the pore walls expand into the pore space and then relax back to their initial size during delithiation with almost no degradation. Importantly, the pores remained open even in the fully lithiated state, and structures are in good physical condition after the 36th cycle. The results of this work should thus be useful for designing nanoscale structures in alloying anodes.

25 ENERGY STORAGE↗

Probing Electron Beam Induced Transformations on a Single-Defect Level via Automated Scanning Transmission Electron Microscopy

A robust approach for real-time analysis of the scanning transmission electron microscopy (STEM) data streams, based on ensemble learning and iterative training (ELIT) of deep convolutional neural networks, is implemented on an operational microscope, enabling the exploration of the dynamics of specific atomic configurations under electron beam irradiation via an automated experiment in STEM. Combined with beam control, this approach allows studying beam effects on selected atomic groups and chemical bonds in a fully automated mode. Here, in this study, we demonstrate atomically precise engineering of single vacancy lines in transition metal dichalcogenides and the creation and identification of topological defects in graphene. The ELIT-based approach facilitates direct on-the-fly analysis of the STEM data and engenders real-time feedback schemes for probing electron beam chemistry, atomic manipulation, and atom by atom assembly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into the Structure and Dynamics of Metal–Organic Frameworks via Transmission Electron Microscopy

Metal–organic frameworks (MOFs) are hybrid materials composed of metal ions and organic linkers featuring high porosity, crystallinity, and chemical tunability at multiple length scales. Here, a recent advancement in transmission electron microscopy (TEM) and its direct application to MOF structure–property relationships have changed how we consider rational MOF design and development. Herein, we provide a perspective on TEM studies of MOFs and highlight the utilization of state-of-the-art TEM technologies to explore dynamic MOF processes and host–guest interactions. Additionally, we provide thoughts on what the future holds for TEM in the study of MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Holes in Optical Lightning Flashes: Identifying Poorly Transmissive Clouds in Lightning Imager Data

Space-based optical lightning sensors including the lightning imaging sensor (LIS) and geostationary lightning mapper (GLM) are pixelated imagers that detect lightning as transient increases in cloud top illumination. Detection requires optical emissions to escape the cloud top to space with sufficient energy to trigger a pixel on the imaging array. Through scattering and absorption, certain clouds are able to block most light from reaching the instrument, causing a reduction in detection efficiency (DE) and possibly location accuracy (LA). Radiant lightning emissions that illuminate large cloud top areas are used to examine scenarios where clouds block light from reaching orbit. In some cases, these anomalies in the spatial radiance distribution from the lightning pulse lead to “holes” in the optical lightning flash where certain pixels fail to trigger. Such holes are identified algorithmically in the Tropical Rainfall Measuring Mission satellite LIS record and the microphysical properties of the coincident storm region are queried. We find that holes primarily occur in tall (IR T b < 235 K) convection (87%) and overhanging anvil clouds (10%). The remaining 3% of holes occur in moderate-to-weak convection or in clear air breaks between stormclouds. We further demonstrate how an algorithm that assesses the spatial radiance patterns from energetic lightning pulses might be used to construct an optical transmission gridded stoplight product for GLM that could help operators identify clouds with a potentially reduced DE and LA.

54 ENVIRONMENTAL SCIENCES↗

Thermoresponsive polymer assemblies via variable temperature liquid-phase transmission electron microscopy and small angle X-ray scattering

Abstract Herein, phase transitions of a class of thermally-responsive polymers, namely a homopolymer, diblock, and triblock copolymer, were studied to gain mechanistic insight into nanoscale assembly dynamics via variable temperature liquid-cell transmission electron microscopy (VT-LCTEM) correlated with variable temperature small angle X-ray scattering (VT-SAXS). We study thermoresponsive poly(diethylene glycol methyl ether methacrylate) (PDEGMA)-based block copolymers and mitigate sample damage by screening electron flux and solvent conditions during LCTEM and by evaluating polymer survival via post-mortem matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS). Our multimodal approach, utilizing VT-LCTEM with MS validation and VT-SAXS, is generalizable across polymeric systems and can be used to directly image solvated nanoscale structures and thermally-induced transitions. Our strategy of correlating VT-SAXS with VT-LCTEM provided direct insight into transient nanoscale intermediates formed during the thermally-triggered morphological transformation of a PDEGMA-based triblock. Notably, we observed the temperature-triggered formation and slow relaxation of core-shell particles with complex microphase separation in the core by both VT-SAXS and VT-LCTEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Differential programming enabled functional imaging with Lorentz transmission electron microscopy

Abstract Lorentz transmission electron microscopy is an advanced characterization technique that enables the simultaneous imaging of both the microstructure and functional properties of materials. Information such as magnetization and electric potentials is carried by the phase of the electron wave, and is lost during image acquisition. Various methods have been proposed to retrieve the phase of the electron wavefunction using intensities of the acquired images, most of which work only in the small defocus limit. Imaging at strong defoci not only carries more quantitative phase information, but is essential to the study of weak magnetic and electrostatic fields at the nanoscale. In this work we develop a method based on differentiable programming to solve the inverse problem of phase retrieval. We show that our method maintains a high spatial resolution and robustness against noise even at the upper defocus limit of the microscope. More importantly, our proposed method can go beyond recovering just the phase information. We demonstrate this by retrieving the electron-optical parameters of the contrast transfer function alongside the electron exit wavefunction.

97 MATHEMATICS AND COMPUTING↗