Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Calibrated helium and carbon ion flow measurements in the DIII-D divertor plasma

To explore the influence of drifts on ion flows in the DIII-D divertor and Scrape-Off-Layer (SOL), a calibrated Coherence Imaging System (CIS) views the lower divertor. A new tuneable calibration laser and precision wavemeter provide the rest wavelength for CIII 465 nm plasma emissions resulting in ≤ 1 km/s uncertainty in ion velocities that are in the range of 30 km/s in the divertor plasma. The 2-D line-integrated velocity images have been tomographically inverted to obtain maps of ion velocity. Both He + and C 2+ ion velocity maps were measured in both directions of the toroidal magnetic field B T , and C 2+ images were obtained in attached and detached L- and H-mode plasmas. The measured C 2+ velocities are in the range of 20-30km/s and are compared with UEDGE modeling with full drifts. While He II as a main ion is expected to be entrained in the plasma flow, the C 2+ impurity flow involves the competition between the frictional and ion temperature gradient forces. Both the CIS data and UEDGE modeling agree that the C 2+ flow is towards the divertor plates, but flips with the direction of B T . In general, the experimental C 2+ emission and flow profiles have a wider spatial extent than the UEDGE modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach

Purpose: X-ray based tomographic blood perfusion imaging requires recovery of contrast time-attenuation-curves from dynamic projection data. When using slowly rotating imaging systems, this task is challenging due to nonsimultaneous projection acquisition. A dynamic reconstruction method is proposed that aims at compensating the lack of simultaneously acquired information by incorporating prior knowledge about the expected temporal contrast dynamics. Methods: A decomposition model using temporal basis functions to approximate time-attenuation-curves is integrated into an iterative tomographic reconstruction method. The computationally efficient implementation of the proposed approach makes use of standard forward-projections and backprojections, as well as scalar products in image space. The critical issue of projection noise propagation is tackled by the application of regularization which is realized by the early stopping of iteration cycles and by the proper selection of smooth temporal basis functions. The performance of the proposed dynamic reconstruction approach is evaluated in a simulation study concerning various aspects: Noise propagation and regularization, specification of the temporal model, and type of acquisition mode. Results: The evaluation based on dynamic phantom data indicates that tomographic recovery of contrast time-attenuation-curves in tissue can be achieved with an average range of accuracy of {approx}2% (with respect to dynamic peak attenuation) under ideal noise-free conditions. The relative estimation error for arterial time-attenuation-curves is in the range of 8%, which is due to faster contrast dynamics in the artery. In general, performance depends on the level of acquired information contained in the projection data, which is mainly influenced by the type of rotational acquisition mode; restrictions in angular range and speed can lead to limited accuracy. The analysis of propagated projection noise in a statistical bias-variance framework reveals relative noise levels in estimated time-attenuation-curves of 3%-4% in tissue regions and below 1% in vessels when using optimized settings for regularization. Here, the effect of noise suppression depends on the interrelation between the number of iteration cycles and the constraints imposed by the temporal decomposition model. Conclusions: For usage with slowly rotating imaging systems, the presented model-based iterative dynamic reconstruction method is capable of recovering contrast time-attenuation-curves related to tissue perfusion. The proposed regularization framework is an effective means to limit the impact of projection noise, which is a factor dominating estimation accuracy in tissue regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-resolution single photon planar and spect imaging of brain and neck employing a system of two co-registered opposed gamma imaging heads

A compact, mobile, dedicated SPECT brain imager that can be easily moved to the patient to provide in-situ imaging, especially when the patient cannot be moved to the Nuclear Medicine imaging center. As a result of the widespread availability of single photon labeled biomarkers, the SPECT brain imager can be used in many locations, including remote locations away from medical centers. The SPECT imager improves the detection of gamma emission from the patient's head and neck area with a large field of view. Two identical lightweight gamma imaging detector heads are mounted to a rotating gantry and precisely mechanically co-registered to each other at 180 degrees. A unique imaging algorithm combines the co-registered images from the detector heads and provides several SPECT tomographic reconstructions of the imaged object thereby improving the diagnostic quality especially in the case of imaging requiring higher spatial resolution and sensitivity at the same time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Information content of and the ability to reconstruct dichroic X-ray tomography and laminography

Dichroic tomography is a 3D imaging technique in which the polarization of the incident beam is used to induce contrast due to the magnetization or orientation of a sample. The aim is to reconstruct not only the optical density but the dichroism of the sample. The theory of dichroic tomographic and laminographic imaging in the parallel-beam case is discussed as well as the problem of reconstruction of the sample’s optical properties. The set of projections resulting from a single tomographic/laminographic measurement is not sufficient to reconstruct the magnetic moment for magnetic circular dichroism unless additional constraints are applied or data are taken at two or more tilt angles. For linear dichroism, three polarizations at a common tilt angle are insufficient for unconstrained reconstruction. However, if one of the measurements is done at a different tilt angle than the other, or the measurements are done at a common polarization but at three distinct tilt angles, then there is enough information to reconstruct without constraints. Possible means of applying constraints are discussed. Furthermore, it is shown that for linear dichroism, the basic assumption that the absorption through a ray path is the integral of the absorption coefficient, defined on the volume of the sample, along the ray path, is not correct when dichroism or birefringence is strong. This assumption is fundamental to tomographic methods. An iterative algorithm for reconstruction of linear dichroism is demonstrated on simulated data.

Marcus, Matthew A. (ORCID:0000000325277586)↗

Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms

Purpose: The authors develop a practical, iterative algorithm for image-reconstruction in undersampled tomographic systems, such as digital breast tomosynthesis (DBT). Methods: The algorithm controls image regularity by minimizing the image total p variation (TpV), a function that reduces to the total variation when p=1.0 or the image roughness when p=2.0. Constraints on the image, such as image positivity and estimated projection-data tolerance, are enforced by projection onto convex sets. The fact that the tomographic system is undersampled translates to the mathematical property that many widely varied resultant volumes may correspond to a given data tolerance. Thus the application of image regularity serves two purposes: (1) Reduction in the number of resultant volumes out of those allowed by fixing the data tolerance, finding the minimum image TpV for fixed data tolerance, and (2) traditional regularization, sacrificing data fidelity for higher image regularity. The present algorithm allows for this dual role of image regularity in undersampled tomography. Results: The proposed image-reconstruction algorithm is applied to three clinical DBT data sets. The DBT cases include one with microcalcifications and two with masses. Conclusions: Results indicate that there may be a substantial advantage in using the present image-reconstruction algorithm for microcalcification imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospects for optical and radio-wave remote imaging of high latitude exospheric processes

The paper examines the use of optical, radio-wave, and extreme UV imaging to study the distribution of magnetospheric plasma continuously and thereby study magnetospheric global dynamics. Optical imaging of the terrestrial exosphere at FUV and EUV wavelengths is discussed in the light of evidence from recent observational campaigns. Radio imaging of the earth's magnetosphere is shown to provide good instantaneous images of the plasma from beyond 4 earth radii. Optical imaging is examined with respect to the study of other planetary exospheres, and the technique is shown to depend on the ability to do normal incidence optics in the EUV. The Cassini radio-uplink experiment is examined as an example of radio-wave tomography which can provide geometry-based tomographic montages to image the heliosphere and the planetary magnetospheres.

Chiu, Y. T.↗

Deep Mapping of Small Solar System Bodies with Galactic Cosmic Ray Secondary Particle Showers

We will investigate the use of galactic cosmic ray (GCR) secondary particles to probe the deep interiors of small solar system bodies (SSBs), including comets, asteroids, and geologic structures on the surfaces of airless bodies. Applications include solar system science, planetary defense, and resource utilization. Our Phase I study demonstrated that muons, the long-range charged component of GCR showers, can penetrate SSBs up to a km in diameter, providing information on their interior structure. Muons produced in Earth’s atmosphere have been applied to image the interior of large objects for science and engineering. In Phase I, we found that the production of muons in the solid surfaces of airless bodies is much smaller than in Earth’s atmosphere. Nevertheless, the flux of transmitted muons is sufficient to detect inclusions within an asteroid or comet in a reasonable amount of time, ranging from hours to weeks, depending on the size of the SSB and the density contrast, position and size of the inclusion. For asteroids and comets, large density variations (e.g., porous soil or ice versus solid rock) are relatively easy to detect. The intrinsic spatial resolution of muon radiography (“muography”) is on the scale of a few meters. The spatial resolution that can be achieved in practice depends on signal intensity and integration time (counting statistics), the angular resolution of the muon tracker (hodoscope) and details of data reduction and analysis methodology. Our Phase II project will assess remaining unknowns for the application of muography to determining the interior structure of SSBs, assess risks for implementation, and provide a roadmap for development of SSB muography beyond the NIAC program. To achieve our objectives, we will focus on four interrelated tasks: Task1) Signal and background characterization: Characterize the production and transmission of muons and secondary particle backgrounds made by cosmic ray showers in SSBs; and near-surface features from radiographic and tomographic data; Task2) Imaging studies: Develop methods to determine the density structure of SSB interiors and near-surface features from radiographic and tomographic data; Task3) Instrument design: Using simulations and bench-top laboratory experiments, investigate specific concepts for the design of compact hodoscopes and components; Task4) Synthesis: Combine the results of the first three tasks to determine the range of applicability of the method, identify the steps needed for maturation of the concept, and explore concepts for a pilot muography mission.

Prettyman, Thomas H.↗

Implementation of Pfirsch–Schlüter parallel flow in x-ray imaging crystal spectrometer inversion analysis

The x-ray imaging crystal spectrometer (XICS) tomographic inversion code for Wendelstein 7-X (W7-X) has been modified to consider the effects of parallel flows and has been applied to analyze measurements taken during recent experimental campaigns. Previous analysis neglected the effects of parallel flows due to the primarily perpendicular geometry of the sightlines and the small magnitude predicted by neoclassical theory. To reconsider these effects, the incompressibility condition for plasma flows is used to calculate the parallel Pfirsch–Schlüter flow component for the equilibrium configuration. By incorporating this condition along with the geometry of the sightlines—i.e. the fractional contributions of perpendicular and parallel flows—, an updated expression for the measured flow is used for the profile inversion. Application of this modified inversion code to data from W7-X shows that the magnitude of the radial electric field and the flux surface averaged perpendicular flow are reduced by approximately a factor of 2 and brought into better agreement with neoclassical predictions and charge exchange recombination spectroscopy measurements.

Pfirsch–Schlüter flows↗

Tomographic decoding algorithm for a nonoverlapping redundant array

A tomographic reconstruction algorithm is developed for the nonoverlapping redundant array X-ray imaging system whereby the background contributions from out-of-focus planes can be eliminated. The algorithm makes use of two constraints derived from the physical characteristics of the nonoverlapping redundant array system in tandem with the correlation decoding process. It is simple, direct, and noniterative. Tomographic images of computer-generated planar and three-dimensional objects are provided to illustrate the effectiveness of the algorithm.

Yin, Lo I.↗

Development of 5- and 10-year-old pediatric phantoms based on polygon mesh surfaces

Purpose: The purpose of this study is the development of reference pediatric phantoms for 5- and 10-year-old children to be used for the calculation of organ and tissue equivalent doses in radiation protection. Methods: The study proposes a method for developing anatomically highly sophisticated pediatric phantoms without using medical images. The 5- and 10-year-old male and female phantoms presented here were developed using 3D modeling software applied to anatomical information taken from atlases and textbooks. The method uses polygon mesh surfaces to model body contours, the shape of organs as well as their positions, and orientations in the human body. Organ and tissue masses comply with the corresponding data given by the International Commission on Radiological Protection (ICRP) for the 5- and 10-year-old reference children. Bones were segmented into cortical bone, spongiosa, medullary marrow, and cartilage to allow for the use of micro computer tomographic ({mu}CT) images of trabecular bone for skeletal dosimetry. Results: The four phantoms, a male and a female for each age, and their organs are presented in 3D images and their organ and tissue masses in tables which show the compliance of the ICRP reference values. Dosimetric data, calculated for the reference pediatric phantoms by Monte Carlo methods were compared with corresponding data from adult mesh phantoms and pediatric stylized phantoms. The comparisons show reasonable agreement if the anatomical differences between the phantoms are properly taken into account. Conclusions: Pediatric phantoms were developed without using medical images of patients or volunteers for the first time. The models are reference phantoms, suitable for regulatory dosimetry, however, the 3D modeling method can also be applied to medical images to develop patient-specific phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

2D imaging of helium ion velocity in the DIII-D divertor

Two-dimensional imaging of parallel ion velocities are compared to fluid modeling simulations to understand the role of ions in determining divertor conditions and benchmark the UEDGE fluid modeling code. Pure helium discharges are used so that spectroscopic He+measurements represent the main-ion population at small electron temperatures. Electron temperatures and densities in the divertor match simulated values to within about 20-30% establishing the experiment/model match as being at least as good as those normally obtained in the more regularly simulated deuterium plasmas. He + brightness (HeII) comparison indicates that the degree of detachment is captured well by UEDGE, principally due to the inclusion of E x B drifts. Tomographically inverted Coherence Imaging Spectroscopy (CIS) measurements are used to determine the He + parallel velocities which display excellent agreement between model and experiment near the divertor target where He + is predicted to be the main-ion species and where electron-dominated physics dictates the parallel momentum balance. Upstream near the X-point where He + is a minority species and ion-dominated physics plays a more important role, there is an underestimation of the flow velocity magnitude by a factor of 2-3. These results indicate that more effort is required to be able to correctly predict ion momentum in these challenging regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Process monitoring of additive manufacturing by using optical tomography

Parts fabricated by means of additive manufacturing are usually of complex shape and owing to the fabrication procedure by using selective laser melting (SLM), potential defects and inaccuracies are often very small in lateral size. Therefore, an adequate quality inspection of such parts is rather challenging, while non-destructive-techniques (NDT) are difficult to realize, but considerable efforts are necessary in order to ensure the quality of SLM-parts especially used for aerospace components. Thus, MTU Aero Engines is currently focusing on the development of an Online Process Control system which monitors and documents the complete welding process during the SLM fabrication procedure. A high-resolution camera system is used to obtain images, from which tomographic data for a 3dim analysis of SLM-parts are processed. From the analysis, structural irregularities and structural disorder resulting from any possible erroneous melting process become visible and may be allocated anywhere within the 3dim structure. Results of our optical tomography (OT) method as obtained on real defects are presented.

42 ENGINEERING↗

Revealing Three-Dimensional Morphology in Nanoporous Gold Using Three-Dimensional X-Ray Fresnel Coherent Diffractive Imaging Tomography

Nanoporous metals fabricated by dealloying have a unique bi-continuous, sponge-like porous structure with ultra-high surface area. The unique properties of these materials, especially nanoporous gold, have numerous potential applications in sensors and actuators and in energy-related applications such as catalytic materials, super-capacitors, and battery supports. The degree of porosity and size of the metal ligaments are critical parameters that determine many properties and thus govern the functionalities of nanoporous metals in many applications including energy storage and conversion. Additionally, we used Fresnel coherent diffractive imaging combined with tomographic reconstruction to quantify the nanoscale three-dimensional spatial distribution and homogeneity of the porosity and ligament size within a bulk sample of nanoporous gold. The average porosity and its standard deviation along the axial direction through the sample were determined, as well as the characteristic feature size and its standard deviation. The result shows that free corrosion is an effective way to create homogeneous nanoporous metals with sample sizes on the order of 1 µm.

36 MATERIALS SCIENCE↗

Parallel Computing for the Computed-Tomography Imaging Spectrometer

This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.

Lee, Seungwon↗

Tomographic Hard X-ray Phase Contrast Micro- and Nano-imaging at TOMCAT

This article illustrates the phase contrast instrumentation installed at the Tomographic Microscopy and Coherent Radiology beamline (TOMCAT) of the Swiss Light Source. Our experimental framework has been designed to extract phase information at spatial resolutions covering three orders of magnitude. For moderate (5-10 microns) resolutions we implemented a two-gratings interferometer, operated at energies between 14 and 40 keV. For high resolution (1-5 microns) we obtain phase information thanks to a modified transport of intensity approach. For very high-resolutions (0.1-0.5 microns) we developed a broadband hard X-ray full-field microscope operated in Zernike-phase contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Toxicity Reduction With Computed Tomographic Ventilation Functional Avoidance Radiation Therapy

Purpose: Computed tomographic (CT) ventilation imaging is a new modality that uses 4-dimensional (4D) CT information to calculate lung ventilation. Although retrospective studies have reported on the reduction in dose to functional lung, no work to our knowledge has been published in which the dosimetric improvements have been translated to a reduction in the probability of pulmonary toxicity. Our work estimates the reduction in toxicity for CT ventilation–based functional avoidance planning. Methods and Materials: Seventy previously treated lung cancer patients who underwent 4DCT imaging were used for the study. CT ventilation maps were calculated with 4DCT deformable image registration and a density change–based algorithm. Pneumonitis was graded on the basis of imaging and clinical presentation. Maximum likelihood methods were used to generate normal tissue complication probability (NTCP) models predicting grade 2 or higher (2+) and grade 3+ pneumonitis as a function of dose (V5 Gy, V10 Gy, V20 Gy, V30 Gy, and mean dose) to functional lung. For 30 patients a functional plan was generated with the goal of reducing dose to the functional lung while meeting Radiation Therapy Oncology Group 0617 constraints. The NTCP models were applied to the functional plans and the clinically used plans to calculate toxicity reduction. Results: By the use of functional avoidance planning, absolute reductions in grade 2+ NTCP of 6.3%, 7.8%, and 4.8% were achieved based on the mean fV20 Gy, fV30 Gy, and mean dose to functional lung metrics, respectively. Absolute grade 3+ NTCP reductions of 3.6%, 4.8%, and 2.4% were achieved with fV20 Gy, fV30 Gy, and mean dose to functional lung. Maximum absolute reductions of 52.3% and 16.4% were seen for grade 2+ and grade 3+ pneumonitis for individual patients. Conclusion: Our study quantifies the possible toxicity reduction from CT ventilation–based functional avoidance planning. Reductions in grades 2+ and 3+ pneumonitis were 7.1% and 4.7% based on mean dose-function metrics, with reductions as high as 52.3% for individual patients. Our work provides seminal data for determining the potential toxicity benefit from incorporating CT ventilation into thoracic treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Marginal Gaps between 2 Calcium Silicate and Glass Ionomer Cements and Apical Root Dentin

Introduction: The outcome of periapical surgery has been directly improved with the introduction of novel material formulations. The aim of the study was to compare the retrograde obturation quality of the following materials: calcium silicate (Biodentine; Septodont, Saint-Maur-des-Fosses, France), mineral trioxide aggregate (MTA+; Cerkamed Company, Stalowa Wola, Poland), and glass ionomer cement (Fuji IX; GC Corporation, Tokyo, Japan). Methods: Materials' wettability was calculated concerning the contact angles of the cements measured using a glycerol drop. Cements' porosity was determined using mercury intrusion porosimetry and micro computed tomographic (mu CT) imaging. Extracted upper human incisors were retrofilled, and mu CT analysis was applied to calculate the volume of the gap between the retrograde filling material and root canal dentin. Experiments were performed before and after soaking the materials in simulated body fluid (SBF). Results: No statistically significant differences were found among the contact angles of the studied materials after being soaked in SBF. The material with the lowest nanoporosity (Fuji IX: 2.99% and 4.17% before and after SBF, respectively) showed the highest values of microporosity (4.2% and 3.1% before and after SBF, respectively). Biodentine had the lowest value of microporosity (1.2% and 0.8% before and after SBF, respectively) and the lowest value of microgap to the root canal wall ({[}10 +/- 30] x 10(-3) mm(3)). Conclusions: Biodentine and MTA possess certain advantages over Fuji IX for hermetic obturation of retrograde root canals. Biodentine shows a tendency toward the lowest marginal gap at the cement-to-dentin interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗