Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “threshold voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Comparative analysis of temperature dependent properties of commercial nuclear fuel pellet and surrogates undergoing cracking: A review

A variety of normal and accident scenarios can generate thermal stresses enough to cause cracking in light water reactor (LWR) fuel. To better understand this behavior, cracking experiments have been carried out to induce thermal gradients in fuel pellets via induction heating and direct resistance heating. In this study, Ceria (CeO 2 ) and yttria stabilized zirconia (YSZ) pellets were chosen as a surrogate fuel material for uranium dioxide (UO 2 ). Induction heating was done using copper coils and molybdenum susceptors which heated the surrogates to a threshold temperature that is sufficiently high for the fuel material to conduct current. Thereafter, direct resistance heating was achieved by passing current through the specimen using a DC power supply to introduce volumetric heating to replicate reactor operating conditions. Simultaneous real-time dual imaging of the ceria pellet surface has been designed using optical and infra-red camera system to capture images of cracks and full-field temperature gradients on pellet. It was observed that YSZ pellets need a much higher voltage-current for volumetric heating and do not exhibit the cracking pattern as ceria and UO 2 , hence YSZ was ruled out for further consideration. Ceria was found to be an appropriate surrogate for UO 2 . Furthermore, the experimental set up and test conditions demand the need to primarily understand the thermo-physical, mechanical and optical properties of UO 2 and the surrogates. Thus, it is essential to have an in-depth knowledge about the various temperature dependent properties of UO 2 and CeO 2 for establishing a comparative analysis between the surrogate and UO 2 for conducting experiments.

36 MATERIALS SCIENCE↗

Alternatives to the ISS Plasma Contacting Units

A spacecraft in a high-density equatorial LEO plasma will float negative relative to the ambient plasma. Because of the electron collection of exposed conductors on its solar arrays, it may float negative by up to its array voltage. The floating potential depends on the relative areas of electron and ion collection of the spacecraft. Early estimates of the International Space Station (ISS) potential were about -140 V relative to the surrounding plasma, because of its 160 V solar array string voltage. Because of the possibility of arcing of ISS structures and astronaut EMUs (spacesuits) into the space plasma, Plasma Contacting Units (PCUs) were added to the ISS design, to reduce the highly negative floating potentials by emitting electrons (effectively increasing the ion collecting area). In addition to the now-operating ISS PCUs, safety rules require another independent arc-hazard control method. In this paper, I discuss alternatives to the ISS PCUs for keeping the ISS floating potential at values below the arc-thresholds of ISS and EMU surface materials. Advantages and disadvantages of all of the recline loss will be presented.

Ferguson, Dale C.↗

Moisture-Induced Structural Degradation in Methylammonium Lead Iodide Perovskite Thin Films

Methylammonium lead iodide (CH 3 NH 3 PbI 3 , MAPbI 3 ) belongs to the group of organic–inorganic halide perovskites (OIHPs) that exhibit exceptional electrical and optical behavior suitable for photovoltaic applications. However, improving its structural and chemical stability and robustness remains a challenge for OIHPs to be considered a feasible active material in optoelectronic devices. This is due to the fact that this material is very susceptible to degrade under various intrinsic and extrinsic factors. Therefore, it is crucial to understand the mechanisms through which MAPbI 3 undergoes chemical degradation under operating conditions such as a relatively humid environment. We present the structural characteristics of MAPbI 3 under working conditions that suggest the routes of phase segregation as a result of exposing to highly moist media. We use dark pulse discharge behavior and current–voltage (I–V) variations of MAPbI 3 under different moisture levels to investigate the nature of structural degradation in OIHPs. Here we show that while relatively lower levels of humidity (~60% RH) have a limited impact on the structural stability of MAPbI 3 , exposure to higher levels of moisture (~100% RH) results in the formation of PbI 2 and aqueous CH 3 NH 3 I, which fundamentally change the charge transport characteristics in MAPbI 3 . Our findings explain the ongoing debate on the presence of a threshold for the humidity that triggers irreversible structural transformation and leads to full degradation of MAPbI 3 .

36 MATERIALS SCIENCE↗

Fault-tolerant grid frequency measurement algorithm during transients

A system determines the frequency of grid signals corresponding to an electrical grid in real time. The system includes a transient detector that monitors a grid signal from a voltage meter or a current meter connected to the electrical grid. The system produces, in real time and at a sampling rate, a deviation signal indicative of a periodicity of the monitored grid signal. The system determines, over one or more cycles of the monitored grid signal, a measurement signal corresponding to the deviation signal. The system determines a frequency signal that corresponds a frequency estimation of the monitored signal by applying a frequency estimation when values of the measurement signal are less than a deviation threshold and maintaining the frequency signal at a constant value when values of the measured signal equal or exceeds the deviation threshold.

Zhan, Lingwei↗

Highly Efficient Vector-Inversion Pulse Generators

Improved transmission-line pulse generators of the vector-inversion type are being developed as lightweight sources of pulsed high voltage for diverse applications, including spacecraft thrusters, portable x-ray imaging systems, impulse radar systems, and corona-discharge systems for sterilizing gases. In this development, more than the customary attention is paid to principles of operation and details of construction so as to the maximize the efficiency of the pulse-generation process while minimizing the sizes of components. An important element of this approach is segmenting a pulse generator in such a manner that the electric field in each segment is always below the threshold for electrical breakdown. One design of particular interest, a complete description of which was not available at the time of writing this article, involves two parallel-plate transmission lines that are wound on a mandrel, share a common conductor, and are switched in such a manner that the pulse generator is divided into a "fast" and a "slow" section. A major innovation in this design is the addition of ferrite to the "slow" section to reduce the size of the mandrel needed for a given efficiency.

Rose, Franklin↗

Comprehensive Study of Carrier Recombination in High‐Efficiency CdTe Solar Cells Using Transient Photovoltage

Cadmium telluride (CdTe) solar cells represent a commercially successful photovoltaic technology, with an annual production capacity approaching 20 GW. However, improving the open-circuit voltage (V OC ) remains challenging. This study aims to deepen the understanding of charge carrier recombination in CdTe solar cells and to explore alternative dynamical characterization methods that address the limitations found in conventionally used time-resolved photoluminescence for CdTe solar cells. Transient photovoltage and transient photocurrent techniques are utilized to investigate charge carrier dynamics under conditions resembling real-world solar cell operation. The results reveal that an effective nonradiative recombination lifetime of 580 ns dominates the charge dynamics at VOC values below 850 mV. Above this threshold, radiative recombination becomes significant, with a radiative recombination coefficient of 1.1 × 10 −9 cm 3 s −1 . Additionally, the stationary charge carrier density at 1 sun is determined to be around 1 × 10 14 cm −3 . By accurately determining both radiative and nonradiative recombination, this work provides a comprehensive understanding of carrier dynamics in high-performing CdTe devices and paves the way for improving the V OC and performance of CdTe solar cells.

CdTe solar cells↗

Constraints on light QCD and CP-violating axions from the death line of rotation-powered pulsars

For axions that couple to nucleons, the presence of dense nuclear matter can displace the axion from its vacuum minimum, sourcing large field gradients around neutron stars (and, more generally, compact objects). These gradients, which we refer to as axion hair, couple to the local background magnetic field, inducing a large voltage drop near the surface of the star; here, we demonstrate that the presence of axion hair decouples local near-field particle acceleration in the open magnetic field line bundle from the rotational frequency of the pulsar itself. This is significant as the non-observation of old slowly-rotating pulsars is attributed to the fact the rotationally-induced electric fields are not strong enough to sustain $e^\pm$ pair production. In this work, we review the evidence for the existence for `pulsar death', i.e. the threshold at which $e^\pm$ pair production (and thus, by association, coherent radio emission) ceases, and demonstrate using both semi-analytics and particle-in-cell simulations that the existence of axion hair can dramatically extend pulsar lifetimes. We show that the non-observation of extremely old, slowly rotating, pulsars allows for a new probe of light QCD and CP-violating axions. We also demonstrate how the observation of emission from both poles of pulsars with nearly orthogonal rotational and magnetic axes, as seen e.g. in PSR J1906+0746, can be used to set competitive limits on CP-violating axion-nucleon interactions.

Witte, Samuel J. [Oxford U., Theor. Phys.; DESY; H↗

A Custom Low-Noise Silicon Photodiode Detector Designed for Use With X-Ray Capillary Optics

We present the first results of a custom low-noise silicon photodiode detector designed for use with X-ray capillary optics. This system is intended to perform as a smaller, lighter, and low-powered alternative to currently existing X-ray telescope technologies. The detector has an active area with a diameter of 100 μm, and its small size leads to a low capacitance of well under 1 pF and a leakage current of 1 pA or less at the depletion voltage. We tested the detector with both a discrete preamp and an ultralow-noise front-end application-specific integrated circuit (ASIC). The front-end ASIC, developed at Brookhaven National Laboratory, was designed for low-capacitance detectors but had not been previously tested with a detector. Here, we discuss the detector design, the experimental setup, and the resulting detector performance. Using radioactive laboratory sources, we measure a full-width at half-maximum (FWHM) of 211 ± 8 eV at 5.9 keV with the ASIC and are able to set the threshold as low as 0.6 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft Syndrome Decoding of Quantum LDPC Codes for Joint Correction of Data and Syndrome Errors

Quantum errors are primarily detected and corrected using the measurement of syndrome information which itself is an unreliable step in practical error correction implementations. Typically, such faulty or noisy syndrome measurements are modeled as a binary measurement outcome flipped with some probability. However, the measured syndrome is in fact a discretized value of the continuous voltage or current values obtained in the physical implementation of the syndrome extraction. In this paper, we use this "soft" or analog information without the conventional discretization step to benefit the iterative decoders for decoding quantum low-density parity-check (QLDPC) codes. Syndrome-based iterative belief propagation (BP) decoders are modified to utilize the syndrome-soft information to successfully correct both data and syndrome errors simultaneously, without repeated measurements. We demonstrate the advantages of extracting the soft information from the syndrome in our improved decoders, not only in terms of comparison of thresholds and logical error rates for quasi-cyclic lifted-product QLDPC code families, but also for faster convergence of iterative decoders. In particular, the new BP decoder with noisy syndrome performs as good as the standard BP decoder under ideal syndrome.

97 MATHEMATICS AND COMPUTING↗

Observation of time-dependent internal charge amplification in a planar germanium detector at cryogenic temperature

For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 min after applying a bias voltage, the charge energy corresponding to a baseline of the 59.54 keVγ rays from a 241 Am source is amplified for a short period of time and then decreases back to the baseline. The amplification of charge energy depends strongly on the applied positive bias voltage with drifting holes across the detector. No such phenomenon is visible with drifting electrons across the detector. We find that the observed charge amplification is dictated by the impact ionization of charged states, which has a strong correlation with impurity level and applied electric field. We analyze the dominant physics mechanisms that are responsible for the creation and the impact ionization of charged states. Our analysis suggests that the appropriate level of impurity in a Ge detector can enhance charge yield through the impact ionization of charged states to achieve extremely low-energy detection threshold (< 10 meV) for MeV-scale dark matter searches if the charge amplification can be stabilized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Low Energy Sputtering Experiments for Ion Engine Lifetime Assessment

The sputtering yield of molybdenum under xenon ion bombardment was measured using a Quartz Crystal Microbalance. The measurements were made for ion kinetic energies in the range 100-1keV on molybdenum films deposited by magnetron sputtering in conditions optimized to reproduce or approach bulk-like properties. SEM micrographs for different anode bias voltages during the deposition are compared, and four different methods were implemented to estimate the density of the molybdenum films. A careful discussion of the Quartz Crystal Microbalance is proposed and it is shown that this method can be used to measure mass changes that are distributed unevenly on the crystal electrode surface, if an analytical expression is known for the differential mass-sensitivity of the crystal and the erosion profile. Finally, results are presented that are in good agreement with previously published data, and it is concluded that this method holds the promise of enabling sputtering yield measurements at energies closer to the threshold energy in the very short term.

Duchemin Olivier B.↗

Characteristics of EMI generated by negative metal-positive dielectric voltage stresses due to spacecraft charging

Charging of spacecraft surfaces by the environmental plasma can result in differential potentials between metallic structure and adjacent dielectric surfaces in which the relative polarity of the voltage stress is either negative dielectric/positive metal or negative metal/positive dielectric. Negative metal/positive dielectric is a stress condition that may arise if relatively large areas of spacecraft surface metals are shadowed from solar UV and/or if the UV intensity is reduced as in the situation in which the spacecraft is entering into or leaving eclipse. The results of experimental studies of negative metal/positive dielectric systems are given. Information is given on: enhanced electron emission I-V curves; e(3) corona noise vs e(3) steady-state current; the localized nature of e(3) and negative metal arc discharge currents; negative metal arc discharges at stress thresholds below 1 kilovolt; negative metal arc discharge characteristics; dependence of blowoff arc discharge current on spacecraft capacitance to space (linear dimension); and damage to second surface mirrors due to negative metal arcs.

Chaky, R. C.↗

Net current measurements and secondary electron emission characteristics of the Voyager plasma science experiment and their impact on data interpretation

The Voyager Plasma Science (PLS) instrument is capable of returning integral (DC) current measurements, similar in some respects to measurements made with a Langmuir probe or a retarding potential analyzer, although there are significant differences. The integral measurements were made during a calibration sequence in the solar wind, during Cruise Science Maneuvers, and within the magnetospheres of Jupiter and Saturn by Voyager 1. After the failure of the PLS experiment following the Saturn encounter, that instrument was placed in the DC return mode returning possibly usable data from early 1981 through early 1985. The DC return measurements are difficult to interpret and are above threshold values only for relatively large fluxes; the determination of the measured current level is dependent on the operating temperature of the preamplifiers which further complicates the interpretation. Nevertheless, these measurements can be used to determine the efficiency of the suppressor grid at preventing the loss of secondary electrons off the collector plate. Some DC return measurements have been invaluable in aiding in the interpretation of some electron plasma measurements not previously understood. It is found that electron spectra can be significantly modified by the presence of second generation secondary electrons produced by either first generation secondaries or photoelectrons on the support ring of the negative high voltage modulator grid within the instrument housing.

Mcnutt, Ralph L., Jr.↗

LabHEART: an interactive computer model of rabbit ventricular myocyte ion channels and Ca transport

An interactive computer program, LabHEART, was developed to simulate the action potential (AP), ionic currents, and Ca handling mechanisms in a rabbit ventricular myocyte. User-oriented, its design allows switching between voltage and current clamp and easy on-line manipulation of key parameters to change the original formulation. The model reproduces normal rabbit ventricular myocyte currents, Ca transients, and APs. We also changed parameters to simulate data from heart failure (HF) myocytes, including reduced transient outward (I(to)) and inward rectifying K currents (I(K1)), enhanced Na/Ca exchange expression, and reduced sarcoplasmic reticulum Ca-ATPase function, but unaltered Ca current density. These changes caused reduced Ca transient amplitude and increased AP duration (especially at lower frequency) as observed experimentally. The model shows that the increased Na/Ca exchange current (I(NaCa)) in HF lowers the intracellular [Ca] threshold for a triggered AP from 800 to 540 nM. Similarly, the decrease in I(K1) reduces the threshold to 600 nM. Changes in I(to) have no effect. Combining enhanced Na/Ca exchange with reduced I(K1) (as in HF) lowers the threshold to trigger an AP to 380 nM. These changes reproduce experimental results in HF, where the contributions of different factors are not readily distinguishable. We conclude that the triggered APs that contribute to nonreentrant ventricular tachycardia in HF are due approximately equally (and nearly additively) to alterations in I(NaCa) and I(K1). A free copy of this software can be obtained at http://www.meddean.luc.edu/lumen/DeptWebs/physio/bers.html.

NASA Discipline Cardiopulmonary↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

Event-driven charge-coupled device design and applications therefor

An event-driven X-ray CCD imager device uses a floating-gate amplifier or other non-destructive readout device to non-destructively sense a charge level in a charge packet associated with a pixel. The output of the floating-gate amplifier is used to identify each pixel that has a charge level above a predetermined threshold. If the charge level is above a predetermined threshold the charge in the triggering charge packet and in the charge packets from neighboring pixels need to be measured accurately. A charge delay register is included in the event-driven X-ray CCD imager device to enable recovery of the charge packets from neighboring pixels for accurate measurement. When a charge packet reaches the end of the charge delay register, control logic either dumps the charge packet, or steers the charge packet to a charge FIFO to preserve it if the charge packet is determined to be a packet that needs accurate measurement. A floating-diffusion amplifier or other low-noise output stage device, which converts charge level to a voltage level with high precision, provides final measurement of the charge packets. The voltage level is eventually digitized by a high linearity ADC.

Doty, John P.↗

Detection of an internal short circuit in a battery

An electrical device comprises a battery cell; a pressure sensor for measuring swelling forces of the battery cell, optionally with voltage, temperature and current sensors, and a battery management system including a controller. The controller executes a program to: (i) determine a reference swelling force corresponding to a reference electrical signal received from the pressure sensor at an earlier reference time, (ii) determine a second swelling force corresponding to a second electrical signal received from the pressure sensor at a later second time, and (iii) determine whether a risk of internal short circuit of the battery cell exists by comparing a reference level of the reference electrical signal and a signal representative of the second electrical signal. When the signal representative of the second electrical signal exceeds the reference level of the reference electrical signal by a threshold amount, a risk of internal short circuit of the cell exists.

Stefanopoulou, Anna G.↗