Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Thermally robust and highly stable method for splicing silica glass fiber to crystalline sapphire fiber

This research reports an advancement in splicing silica glass fiber to sapphire single-crystal optical fiber (SCF) using a specialized glass processing device, including data that demonstrate the thermal stability of the splice to 1000°C. A filament heating process was used to produce a robust splice between the dissimilar fibers. A femtosecond laser is used to inscribe a fiber Bragg gratings sensor into the SCF to measure the high-temperature capabilities and signal attenuation characteristics of the splice joint. The experimental results demonstrate that the proposed splicing method produces a splice joint that is robust, stable, repeatable, and withstands temperatures up to 1000°C with a low attenuation of 0.5 dB. Here, the proposed method allows placement of SCF-based sensors in the extreme environments encountered in various engineering fields, such as nuclear, chemical, aviation, and metals manufacturing, to enable improvements in process monitoring, product quality, and production efficiency.

36 MATERIALS SCIENCE↗

Continuous snow depth and temperature measurements from dense network of above-ground distributed temperature profiling systems from 2021-09-23 to 2024-08-23, Seward Peninsula, Alaska

The dataset contains temperature measurements from distributed temperature profiling (DTP) systems (Dafflon et al., 2022; Wielandt et al., 2022; Wang et al., 2024a; Fiolleau et al., 2024) deployed vertically above the ground surface at a large number of locations from 2021 to 2024. The research is designed to improve understanding of the local heterogeneity in snow depth and snow thermal insulation dynamics, as well as their interactions in a discontinuous permafrost region (Wang et al., 2025). The DTP systems were deployed at 96 locations in a watershed along the Nome-Teller road at mile marker 27 (T27) and at 54 locations on a hillslope along the Kougarok road at mile marker 64 (K64) in the Seward Peninsula, Alaska. The probe location information is stored in Probe_locations_T27.csv and Probe_locations_K64.csv. Temperature measurements were recorded at 15-minute intervals using high-precision digital sensors (accuracy: ±0.1°C, resolution: 0.0078°C). The temperature probes, either 1.4 m or 1.6 m long, contain sensors spaced every 5 cm or 10 cm along their length. The temperature data are stored in compressed files following the format: DTP_snow_air_temperature_(site)_(start)_(end).zip, where site is either T27 or K64, and start and end represent the time series period. Within each ZIP file, individual CSV files are named by probe ID and contain temperature records at different heights above the ground surface.This dataset also includes derived snow depth time series over three snow seasons, estimated from temperature measurements. Snow depth was estimated by identifying the consecutive sensor pair that exhibited the largest drop in high-frequency temperature fluctuations (detailed in the methods). These data are stored in: Snow_depths_flags_(site)_(start)_(end).csv, which includes snow depth time series and corresponding quality flags (defined in the methods) from different probes. Additionally, the dataset includes derived metrics and supporting measurements at selected locations over two snow seasons, contributing to the manuscript of Wang et al., 2025. These locations were chosen based on the availability of high-quality snow depth time series during both seasons. The additional data include: (1) Air temperature proxies measured from the top sensors on the pole when they were not buried by snow, stored in Air_temperature_proxies_(site)_(start)_(end).csv (2) Ground interface temperature, recorded at 3 cm above the ground, stored in Ground_interface_temperature_(site)_(start)_(end).csv (3) Site characteristics, including vegetation height, elevation, and the topographic position index (TPI) within a 50 m radius, stored in Selected_probe_locations_gps_vegheight_tpi_elevation_(site).csv. These metrics were derived from 1 m resolution summer LiDAR-based digital elevation models and digital surface models from Singhania et al., 2023, DOI:10.5440/1832016. Metadata files include data descriptions (_dd.csv) for tabular data. All included files are listed and described in xxxx_flmd.csv.This dataset is an updated version of a previous archive (Wang et al., 2024b, DOI: 10.15485/2475020), incorporating multiple seasons and improved snow depth estimation. Please note that due to large amount of information present in this dataset, many specificities associated with the acquisition of snow temperature, air temperature proxy and estimation of snow depth, and the future archiving of additional datasets on the soil temperature, thaw depth and soil characteristics at these locations, the author would welcome being contacted by people planning to use this dataset.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

A new open‐path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections

Abstract Low‐power, open‐path gas sensors enable eddy covariance (EC) flux measurements in remote areas without line power. However, open‐path flux measurements are sensitive to fluctuations in air temperature, pressure, and humidity. Laser‐based, open‐path sensors with the needed sensitivity for trace gases like methane (CH 4 ) and nitrous oxide (N 2 O) are impacted by additional spectroscopic effects. Corrections for these effects, especially those related to temperature fluctuations, often exceed the flux of gases, leading to large uncertainties in the associated fluxes. For example, the density and spectroscopic corrections arising from temperature fluctuations can be one or two orders of magnitude greater than background N 2 O fluxes. Consequently, measuring background fluxes with laser‐based, open‐path sensors is extremely challenging, particularly for N 2 O and gases with similar high‐precision requirements. We demonstrate a new laser‐based, open‐path N 2 O sensor and a general approach applicable to other gases that minimizes temperature‐related corrections for EC flux measurements. The method identifies absorption lines with spectroscopic effects in the opposite direction of density effects from temperature and, thus, density and spectroscopic effects nearly cancel one another. The new open‐path N 2 O sensor was tested at a corn ( Zea mays L.) field in Southwestern Michigan, United States. The sensor had an optimal precision of 0.1 ppbv at 10 Hz and power consumption of 50 W. Field trials showed that temperature‐related corrections were 6% of density corrections, reducing EC random errors by 20‐fold compared to previously examined lines. Measured open‐path N 2 O EC fluxes showed excellent agreement with those made with static chambers ( m = 1.0 ± 0.3; r 2 = .96). More generally, we identified absorption lines for CO 2 and CH 4 flux measurements that can reduce the temperature‐related corrections by 10–100 times compared to existing open‐path sensors. The proposed method provides a new direction for future open‐path sensors, facilitating the expansion of accurate EC flux measurements.

47 OTHER INSTRUMENTATION↗

Physical Modeling of Coupled Thermohydraulic Behavior of Compacted MX80 Bentonite during Heating

Abstract This paper describes a tank-scale test setup and experimental methodology used to investigate coupled heat transfer and water flow processes during heating of compacted MX80 bentonite to high temperatures. Specifically, a temperature of 200°C was maintained by a cylindrical heating element at the center of a compacted bentonite layer containing an array of temperature, dielectric, and relative humidity sensors. In addition to providing an evaluation of the spatiotemporal variations in temperature, relative humidity, degree of saturation, and global volume, the coupled thermohydraulic properties of the bentonite were assessed. A wetting front was initially observed to move away from the central heater, followed by a drying process until reaching thermohydraulic equilibrium. The soil–water retention curve (SWRC) of the bentonite followed a wetting scanning path before following the primary drying path exhibiting a shift in water retention with elevated temperature. Results from the tank-scale test can be used for validation of numerical simulations of drying processes in the engineered barrier system of a high-level radioactive waste geological disposal repository and confirm that a temperature-dependent hysteretic SWRC with scanning paths is required to accurately capture the bentonite response.

Engineering↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

Soil moisture and temperature data along the northeast facing hillslope at the Lower Montane site in the East River Watershed, Colorado

Soil moisture, temperature and electrical conductivity have been monitored with 5TE sensors (Decagon Inc.) located at 10 and 50 cm depth at 4 different locations along the northeast-facing slope at the Lower Montane site in the East River Watershed, Colorado from Oct 2016 to Oct 2018. The purpose of this data is to inform hydrobiogeochemical analyses for the Watershed Function Scientific Focus Area (SFA). The data is reported in 4 csv files labeled their by location identifiers (ER-SMN1-5) and location metadata is provided in SM_loc.csv. These data products are part of the Watershed Function Scientific Focus Area collection effort to further scientific understanding of biogeochemical dynamics from genome to watershed scales.

54 ENVIRONMENTAL SCIENCES↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Flexible CO 2 Sensor Architecture with Selective Nitrogen Functionalities by One‐Step Laser‐Induced Conversion of Versatile Organic Ink

Abstract Nitrogen‐containing carbons (NC) are a class of sustainable materials for selective CO 2 adsorption. A versatile concept is introduced to fabricate flexible NC‐based sensor architectures for room‐temperature sensing of CO 2 in a one‐step laser conversion of primary films cast from abundant precursors. By the unidirectional energy impact in conjunction with depth‐dependent attenuation of the laser beam, a layered sensor heterostructure with a porous transducer and active sensor layer is formed. Comprehensive microscopic and spectroscopic cross‐sectional analyses confirm the preservation of the high content of imidazolic nitrogen in the sensor. The performance is optimized in terms of material morphology, chemical composition, and surface chemistry to achieve a linear relative resistive response of up to Δ R / R 0 = −14.3% (10% of CO 2 ). Thermodynamic analysis yields Δ ads H values of −35.6 and 34.1 kJ·mol −1 for H 2 O and CO 2 , respectively. The sensor is operable even in humid environments (e.g., ∆ R / R 0,RH = 80% = 0.53%) and shows good performance upon strong mechanical deformation.

flexible gas sensors↗

Leveraging Optimal Sparse Sensor Placement to Aggregate a Network of Digital Twins for Nuclear Subsystems

Nuclear power plants (NPPs) require continuous monitoring of various systems, structures, and components to ensure safe and efficient operations. The critical safety testing of new fuel compositions and the analysis of the effects of power transients on core temperatures can be achieved through modeling and simulations. They capture the dynamics of the physical phenomenon associated with failure modes and facilitate the creation of digital twins (DTs). Accurate reconstruction of fields of interest (e.g., temperature, pressure, velocity) from sensor measurements is crucial to establish a two-way communication between physical experiments and models. Sensor placement is highly constrained in most nuclear subsystems due to challenging operating conditions and inherent spatial limitations. This study develops optimized data-driven sensor placements for full-field reconstruction within reactor and steam generator subsystems of NPPs. Optimized constrained sensors reconstruct field of interest within a tri-structural isotropic (TRISO) fuel irradiation experiment, a lumped parameter model of a nuclear fuel test rod and a steam generator. The optimization procedure leverages reduced-order models of flow physics to provide a highly accurate full-field reconstruction of responses of interest, noise-induced uncertainty quantification and physically feasible sensor locations. Accurate sensor-based reconstructions establish a foundation for the digital twinning of subsystems, culminating in a comprehensive DT aggregate of an NPP.

42 ENGINEERING↗

Distributed Temperature Profiles of Silicon Carbide Catalyst Bed in a Microwave Reactor using Fiber-optic Sensor

Microwave heating is of great interest for reducing greenhouse gas emissions of catalytic chemical conversion processes because it can heat up the reactants rapidly and efficiently and accelerate reaction rates. In microwave-assisted catalytic thermochemical conversion processes, accurate internal temperature measurement would help facilitate effective process control. Metallic thermocouples interfere and spark in the microwave heating environment, so they are not an option. Infrared pyrometers typically provide a single temperature value by averaging over a finite surface area of the catalyst bed. In this work, we use fiber-optic sensors passing through the catalyst bed to provide more accurate temperatures along the height of the catalyst bed. The fiber optic sensors are immune to the electromagnetic microwave radiation and provide temperature profiles along their length. Here, custom fiber-optic sensors were coupled to the optical distributed temperature sensing devices to measure the temperature profiles along the height of the catalyst bed at high temperatures with ~1 mm spatial resolution. The sensing devices use optical frequency domain reflectometry (OFDR) technique for distributed temperature measurement. This work shows the temperature profiles along the height of the silicon carbide powder catalyst bed in the variable and fixed frequency microwave reactors.

Thapa, Juddha↗

Post-fire time series of sensor and geochemistry sample data from surface water, groundwater, precipitation, soil, and vegetation across Oak Creek watershed, Washington

This dataset supports a broader study examining wildfire impacts on hydrologic connectivity across 5 sites within the Oak Creek watershed and the resulting biogeochemical impacts. Stream sites were selected using the Advanced Terrestrial Simulator (ATS) hydrologic model to identify locations with varying groundwater contributions and hydrologic responses across different burn severity scenarios. The Retreat Fire burned from July 23 to August 2 in 2024, affecting the five study sites at varying burn severities. Each site is equipped with YSI EXO2 sondes logging sub-hourly throughout the year, and grab samples are collected approximately every six weeks. YSI sondes are used to measure temporally resolved proxies for groundwater inputs (specific conductivity) and organic matter (fluorescent dissolved organic matter; fDOM) along with basic water quality and depth. Grab samples of surface water, groundwater, and precipitation are analyzed for water stable isotopes and conductivity to understand endmembers for hydrologic mixing Grab samples of surface water, groundwater, soil water, and litter/vegetation/soil leachates are analyzed for organic matter composition measured by Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR-MS) to understand organic matter dynamics. Game camera photos are provided in a separate data package available at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3018598. Future versions of this dataset will include time series data from YSI EXO2 sondes (fDOM, dissolved oxygen, temperature, depth, specific conductance, turbidity, pH), BaroTROLL sensors (air temperature and barometric pressure), rain gauges (precipitation), and data from the soil and vegetation samples. Because this study is ongoing, this data package will be updated regularly to include newly collected data and the additional data types. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) a folder of field photos; (2) a folder of surface water sample data; (3) a folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data; (4) a data checks report; (5) file-level metadata; (6) data dictionary; (7) field metadata; (8) readme; (9) international generic sample number (IGSN) mapping file; and (10) field protocols. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) total dissolved nitrogen data and averages; (3) stable water isotopes and averages; (4) methods codes; (5) FTICR-MS methods; and (15) a subfolder of 9.4 Tesla (9.4T) FTICR-MS data. This folder contains the processed data and three subfolders, one containing the .xml files, one containing the water CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .xml, .d, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, .png, .mov, or .mp4.

Biogeochemistry↗

Real-time sensor measurements to evaluate impacts of load cycling on high-temperature fire-side corrosion in a PC boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

One-Step Ahead Prediction of Thermal Mixing Tee Sensors with Long Short Term Memory (LSTM) Neural Networks

High-temperature advanced reactors under development, such as sodium fast reactors (SFR) and molten salt cooled reactors (MSCR), are expected to offer lower levelized cost of energy (LCOE) compared to existing light water reactor (LWR’s). In the existing light water reactors (LWR’s), operation and maintenance (O&M) expenses constitute the largest fraction of the total operating cost. Some of the O&M costs are related maintenance of sensors which can fail due to exposure to harsh environment in a reactor. The O&M costs of Advanced Reactor (AR)’s are expected to constitute a significant fraction of the total cost as well, because of high temperature and radiation level in AR are likely to cause material fatigue and premature failure of sensors and components. The O&M costs in AR’s could be reduced through integration of advanced informatics of performance-related sensors into a digital twin designed for reactor monitoring. For example, machine learning (ML) could be employed for real-time validation and correction of performance-related sensors, and reducing the number of performance-related physical sensor units through virtual sensing. As part of the effort, we investigate real-time validation of thermal hydraulic sensors through one-step ahead forecasting of sensor values using long short-term memory (LSTM) recurrent neural networks (RNN). The sensors are installed in a flow loop containing a thermal mixing tee, which is a common experimental model to study thermal fatigue in a thermal hydraulic loop. In addition, nonlinear transients generated in a thermal mixing tee constitute a good challenge data set for training and validation of ML algorithms. Sensors in this study include thermocouples, flow meters, and optical fibers for distributed temperature sensing. In one experiment, measurement data sets were obtained for a loop was filled with water, and in another experiment, measurements were performed on a loop filled with liquid metal Galinstan. We have also conducted preliminary investigation of one-step ahead prediction of fiber optics-based distributed temperature sensing with LSTM networks. In predicting fiber-based temperature measurements, we treated each gauge pitch of the fiber as an independent sensor. Accuracy of one-step ahead forecasting was estimated by calculating root mean square error (RMSE) for the test segment of time series of each sensor. RMSE’s for temperature sensors in water loop were, for the most part, lower than for the same sensors in Galinstan loop. The RMSE’s for flow meters were similar for both loops. The RMSE’s for distributed temperature measured with the fiber optic sensor were similar to those of the point sensors. Results of this study demonstrated the capability of LSTM one-step ahead forecasting with RMSE comparable to uncertainty in sensor measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Temperature Mapping analysis of Nitrogen-doped Niobium Radio Frequency Cavity

Nitrogen-doping of niobium superconducting radio-frequency (SRF) cavity has been shown to significantly improve the quality factors as compared to the standard treated niobium cavities. However, the nitrogen-doped cavities generally quench at lower accelerating gradients. To understand the possible sources of rf losses in nitrogen-doped cavities that could reduce the quench field, we used 576 thermometer sensors to map the temperature distribution of the outer cavity surface while increasing the accelerating field. Our measurements have revealed a strong effect of the cavity cooldown rate on the intensity of hot spots and their spatial distribution, indicating a significant contribution from trapped vortices on the RF losses.

Makita, Junki↗

Reduction of Iron (III) Oxide in Microwaves Toward Gasification Studies

The purpose of this study is to reduce hematite (Fe2O3) using hydrogen (H2), carbon monoxide (CO), and methane (CH4) gases using microwave irradiation. Conventional temperature programmed reduction of iron phase transformation under H2, CO, and CH4 agree with the literature. Furthermore, the activation energy for the iron phase transformation in a conventional reactor was in the order of H2>CO>CH4, suggesting that CH4 was the best reductant to initiate the reduction at a much lower temperature than CO, and CO was significantly better than H2 atmosphere. Due to the uneven temperature distribution, the apparent activation energy of microwave reduction under H2 was approximately 1/4th when compared to the conventional reduction in H2. X-ray diffraction (XRD) analysis showed a mixed oxide phase in microwave reduction as opposed to the clear phase transformation in conventional studies. To combat the temperature measurement issues in microwave studies, fiber optic sensors and Forward Looking InfraRed (FLIR) sensors were used to acquire the actual temperature distribution in the catalyst bed. Therefore, a reasonably accurate activation energy estimation was achieved in the catalyst bed. Combining these with the characterization and quantification of the different iron phases in microwave reduction will provide a blueprint for future microwave-assisted gasification studies.

Aireddy, Divakar Reddy↗