Gas-Cooled High-Temperature Pebble-Bed Reactor Reference Plant Model Updates

This work presents the latest improvements to, and investigations performed with, the pebble-bed high-temperature gas-cooled reactor (PB-HTGR) reference plant models for the United States Nuclear Regulatory Commission. These models serve as the foundation for the future development of detailed design evaluation models based on license applications. The reference plant models have been developed with the Comprehensive Reactor Analysis Bundle, or BlueCRAB, which is the code suite proposed for non-light-water reactor systems safety analysis. It incorporates various simulation tools developed by the Nuclear Energy Advanced Modeling and Simulation program, including the Griffin code for reactor physics, the Pronghorn and SAM codes for core thermal fluids, the BISON code for solid conduction and fuel performance, and the SAM code for system analysis. The primary objective of the work that was performed was to assess BlueCRAB’s level of readiness for modeling a PB-HTGR. To do so, we first developed numerical models in BlueCRAB that include the key physics for this technology to ensure an adequate level of fidelity for modeling PB-HTGR core performance and for performing multiphysics simulations for equilibrium core conditions and different accident scenarios. Then we simulated transient scenarios, including depressurized and pressurized loss of forced cooling accidents, over-cooling, and control rod withdrawal events with delayed and prompt supercritical reactivity insertions. The analysis in this report includes comparisons of the 2D thermal fluid porous media models in Pronghorn and SAM, and comparisons of coupled SAM/Griffin/SAM and coupled Pronghorn/Griffin for depressurized and pressurized loss of forced cooling, over-cooling, and control rod withdrawal events. In addition, we compare 3D, 2D, and 0D/PKE neutronic models for the two control rod withdrawal scenarios with coupled Pronghorn/Griffin. The comparisons show that the BlueCRAB models lead to physically intuitive solutions for the scenarios examined. The changes in the various scalar and vector fields, such as neutron flux, power, temperature, density, pressure, and velocity, are within the expected ranges, and their distributions can be explained by the system response of the transients and the geometric and material variations. Several comparisons suggest that the porous media models in Pronghorn and SAM can lead to similar solutions, even though they are based on different methodologies. This work further highlights the need for flexible tools with various levels of fidelity to cover the breadth and depth of needs that may arise in future technical evaluations of the PB-HTGR. We believe that the BlueCRAB capabilities will be a significant asset for confirmatory analyses in order to resolve important safety questions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scaling Up CSP: How Long Will it Take?

Concentrating solar power (CSP) is one of the few scalable technologies capable of delivering dispatchable renewable power. Therefore, many expect it to shoulder a significant share of system balancing in a renewable electricity future powered by cheap, intermittent PV and wind power: the IEA, for example, projects 73 GW CSP by 2030 and several hundred GW by 2050 in its Net-Zero by 2050 pathway. In this paper, we assess how fast CSP can be expected to scale up and how long time it would take to get new, high-efficiency CSP technologies to market, based on observed trends and historical patterns. We find that to meaningfully contribute to net-zero pathways the CSP sector needs to reach and exceed the maximum historical annual growth rate of 30%/year last seen between 2010-2014 and maintain it for at least two decades. Any CSP deployment in the 2020s will rely mostly on mature existing technologies, namely parabolic trough and molten-salt towers, but likely with adapted business models such as hybrid CSP-PV stations, combining the advantages of higher-cost dispatchable and low-cost intermittent power. New third-generation CSP designs are unlikely to play a role in markets during the 2020s, as they are still at or before the pilot stage and, judging from past pilot-to-market cycles for CSP, they will likely not be ready for market deployment before 2030. CSP can contribute to low-cost zero-emission energy systems by 2050, but to make that happen, at the scale foreseen in current energy models, ambitious technology-specific policy support is necessary, as soon as possible and in several countries.

concentrated solar power↗

Small-Scale Engineered High Flexibility Gasifier

This project advances a small-scale gasification unit as the first step in syngas-based hydrogen, chemicals, and synthetic fuels production. This unit is associated with an enhanced flexibility to different carbonaceous feedstocks including different types of coals, biomass, and plastics. The purpose of the project was to demonstrate feasibility and efficiency of coal pyrolysis in an auger reactor (pyrolyzer); supplemental methane and pyrolysis gas conversion into syngas in a proprietary non-catalytic converter; combined performance of pyrolyzer and non-catalytic converter to convert coal into syngas The proposed technology is based on an application of an intermediate speed pyrolysis at the temperature range 400-600°C as the first stage of biomass processing. At an industrial scale, an incorporation of coal pyrolysis into a feeding machine – auger-reactor allows to decrease its capital cost. At a pilot scale, it permits to employ electricity to build a compact device for testing of downstream equipment. The auger-reactor (pyrolyzer) generates pyrolysis gas and char practically from any carbonaceous feedstocks but their compositions and quantities are determined by their types. Pyrolysis gas is converted into syngas (mix of H 2 and CO) in a novel, proprietary hydrogen flame assisted non-catalytic converter which employs O 2 instead of air as an oxidizer. This reactor (converter) allows an easy adjustment to different pyrolysis gas compositions and tolerates a presence of sulfur and nitrogen contaminants. Our technology assumes carbonaceous feedstocks gasification with oxygen to allow the products H 2 , CO or CO 2 to be not diluted in N 2 and ready for the following synthesis of chemicals and fuels. Due to the same reason, it permits a more efficient CO 2 capture for its transport and storage. An implementation of our small-scale gasification process may overcome economic constrains by a flexible acceptance of coal, biomass, and plastics as well as their unsorted mixtures to make syngas for the following production of pure hydrogen, chemical and/or synthetic fuels.

42 ENGINEERING↗

Cradle to grave: the importance of the fuel cycle to molten salt reactor sustainability

Advanced reactor technologies are being considered for the next-generation of nuclear power plants. These plants are designed to have a smaller footprint, run more efficiently at higher temperatures, have the flexibility to meet specific power or heating needs, and have lower construction costs. This paper offers a perspective on molten salt reactors, promoted as having a flexible fuel cycle and close-to-ambient pressure operation. A complexity introduced by reducing the reactor footprint is that it may require low-enriched fuel for efficient operation, available from enrichment of the feed salt or by reusing actinides from existing used nuclear fuel (UNF). Recycling UNF has the potential to reduce high-level waste, if done correctly. Release limits from UNF processing are stringent, and processes for waste reduction, fission gas trapping, and stable waste-form generation are not yet ready for commercial deployment. These complex processes are expensive to develop and troubleshoot because the feed is highly radioactive. Thus, fuel production and supply chain development must keep abreast of reactor technology development. Another aspect of reactor sustainability is the non-fuel waste streams that will be generated during operation and decommissioning. Some molten salt reactor designs are projected to have much shorter operational lifetimes than light-water reactors: less than a decade. A goal of the reactor sustainability effort is to divert these materials from a high-level waste repository. However, processing of reactor components should only be undertaken if it reduces waste. Economic and environmental aspects of sustainability are also important, but are not included in this perspective.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proliferated Resilient Economical Half-Meter Aperture Space Telescopes (PREEMPT)

The PREEMPT LDRD was motivated by a major national need for better space-based imaging systems that are both high performing and affordable for the US Government. Current optical payloads for intelligence, surveillance and reconnaissance (ISR) and space domain awareness (SDA) missions can cost hundreds of millions of dollars and take years to develop, which makes it difficult to build the large constellations required for persistent, world-wide coverage. To address this, the team aimed to advance a different kind of large-aperture (>25 cm) telescope, called a monolithic telescope, in which key optical surfaces are built into a single piece of fused silica. This design greatly reduces payload and spacecraft complexity, the need for precision focus actuators, improves mechanical and thermal robustness, and lowers cost when compared with traditional Cassegrain telescopes that rely on many precisely aligned components. The project focused on five primary thrusts. The first thrust was to advance the concept of a V10, 25 cm, monolithic telescope forward from optical design to flight-ready stage. This was accomplished in partnership with Optimax, who delivered the first test unit in the early stages of the LDRD. The team developed several technologies necessary for this optic to be integrated into a flight demonstration. These include carbon fiber housings, highly detailed structural and thermal models and stress-reducing elastic averaging Hirth groove designs. These technologies resulted in a successful maturation of the optic, which is now slated to fly in late 2026/early 2027 for a demonstration mission. The second thrust was to advance the manufacturability of these optics. In collaboration with NIF’s optical manufacturing shop, we reduced polishing time from 480 hours to 65 hours through the implementation of optimized processes and new tools. The NIF team utilized a conceptual V8 (18 cm) optic to demonstrate this optimization, though it can be applied to the rest of the monolithic optic portfolio. Third, the team developed the first conceptual V20 (50 cm) payload, which is slated to be the next generation of LLNL optical payload systems. A set of structural, dynamic and thermal simulations were performed to identify potential challenges in the future development of this payload. Early-stage simulations suggest the payload is feasible, though thermal management will be the key focus area to maintain optimal performance. Fourth, a non-linear model of Viton was developed, to further enhance the reliability of our structural and dynamic models for future payloads. Viton acts as the primary interface material between the optic and its housing. Lastly, the team focused on successfully displaying the feasibility of using additively manufactured metal composites for optical space payloads. The team successfully demonstrated layer by layer deposition of Al-SiC composites, which have highly tunable structural and coefficient of thermal expansion (CTE) properties. These are crucial for optical payloads because CTE mismatch is one of the causes for degraded optical performance for telescopes in orbit. Overall, the work showed that monolithic telescopes could become a practical, lower-cost path to high-resolution space imaging for both national security and scientific missions.

42 ENGINEERING↗

Virtual and Augmented Realities to Support Development, Training, Deployment, and Operations of Remote Systems - 20516

Throughout the U.S. Department of Energy complex, there is a need to deploy new, unique equipment and systems for cleanup activities, waste processing, infrastructure repair, and decommissioning and demolition in radioactive and hazardous environments. The new equipment often consists of custom systems created by integrating and modifying commercial technologies. In addition, the systems are deployed in unique environments due to limited access, waste properties, and the presence of previously installed equipment or infrastructure that has been left in place. The deployment of custom systems that are 'turnkey' ready for first-time installation and application has its risks. Use of test platforms and mockups for cold (i.e., non-radioactive) testing is one method to mitigate that risk: however, full-scale test mockups for operations such as waste retrieval and tank inspection can be expensive and must be modified to incorporate the uniqueness of each application. An alternative to full-scale mockups is to use three-dimensional (3D) virtual environments and virtual reality (VR) technology to develop interactive virtual test beds. These can be used throughout the down-selection, development, system integration, operational planning, operator training, and mission execution phases of a task. Virtual test beds are readily reconfigured, can be used for multiple tasks, support multiple users in parallel, and can accommodate enhancements and changes not originally planned or conceived in the initial design. Virtual test beds also provide a platform for developing and testing augmented reality (AR) tools for improving operator efficiency. A VR experience has been generated for waste retrieval from a Hanford waste tank to present the potential applications of a virtual test bed. Features of the VR experience are presented, potential applications of VR and AR for remote applications are discussed, and development areas for improving future application are considered. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deployment Readiness Framework Subtask 1.2 Outreach Report: Common Themes Among Clean Energy Transition Technical Assistance Projects

Island and remote coastal communities face an uncertain energy future. These communities build, operate, and maintain energy infrastructure in extremely challenging environments and pay the highest prices for electricity and fuels. Moreover, climate change increasingly affects grid reliability, resiliency, and, ultimately, the cost of energy. Marine energy could address many of the challenges faced by island and remote coastal communities, but these communities often have limited resources and capacity to invest in complex energy and coastal resilience issues. The Deployment Readiness Framework (DRF) is being developed to support community-driven energy transitions in these coastal communities and to better understand the readiness of communities for marine energy demonstration and operation. Led by the National Renewable Energy Laboratory and Pacific Northwest National Laboratory, the DRF builds on the Energy Transitions Initiative Partnership Project (ETIPP) supported in part by the U.S. Department of Energy's Water Power Technologies Office. This report details the results from the stakeholder outreach and engagement effort linked to the previously reported literature review.

16 TIDAL AND WAVE POWER↗

Scale up, Field testing, and Optimization of Nontoxic, Durable, Economical Coatings for Control of Biofouling and Corrosion (Abstract Only)

The objective of this project is the technical maturation and demonstration of a durable, economical, and nontoxic coating, Superhydrophobic Lubricant Infused Composite (SLIC), that will prevent fouling organisms from growing on marine and hydrokinetic (MHK) structures and prevent invasive mussels from growing on hydropower structures. SLIC technology was developed and patented by PNNL. It combines multiple antifouling mechanisms to provide excellent antifouling performance, durability, and low hydrodynamic drag without using toxic materials. Advanced proof-of-concept testing and demonstrations completed during a Phase 1 TCF project attracted industry interest and partnerships for this Phase 2 effort focused on maturation of a commercial product. Specific tasks and tests will shift the development emphasis to optimizing formulations, validating antifouling performance to address specific application needs, explore compatibility with other paint systems, develop a product with useful shelf life (in can), and determine curing times and effective applications methodology. Phase 2 efforts will focus upon technology transfer and commercialization of the technology with the industrial team. Industrial partners now include a coatings development specialist (Lorama), hydrophobic material manufacturer and paint developer (Dry Surface Technologies), nontoxic biodegradable lubricants manufacturer (BioBlend), and aquatic applications specialists (Prometheus Innovations, River Connectivity Systems). Engagement with the MHK device developers, the PNNL Marine and Coastal Research Laboratory (MCRL) test site in Sequim WA, Bureau of Reclamation, and Taylor Shellfish throughout the project will provide topical expertise and field test sites that will deliver crucial real-world performance data. Through this Phase 2 effort, SLIC will transition from a Technical Readiness Level (TRL) 5 to TRL 6 and long-term performance data will be acquired through demonstrations. The field test data will allow optimization of SLIC formulation to enhance performance (e.g., durability) and packaging, which are key de-risking activities for technology transfer and ultimately to the production of a viable commercial product.

13 HYDRO ENERGY↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Field testing and validation of a low-cost MPC for demand flexibility for grid-interactive K-12 schools

K-12 school buildings account for the highest energy consumption within the public sector. Implementing advanced HVAC controls in grid-interactive K-12 schools could bring substantial economic advantages and grid flexibility. Our previous study demonstrated that a low-cost model predictive control (MPC) solution, which coordinates multiple packaged units, can enable demand flexibility without major hardware upgrades. However, a significant gap remains between academic pilots and market-ready scalable solutions. This paper extends the previous single-site pilot to a multi-site demonstration involving three school campuses (95 total units) through a commercial technology transfer process. Addressing the challenge of verifying performance with sparse field data, we present a new statistical approach using Bayesian methods to estimate the MPC’s effect on peak demand. Unlike traditional methods, this approach robustly quantifies uncertainty in non-normal, limited datasets. The results confirm the solution’s replicability, achieving a 21.6–38.9% reduction in HVAC peak demand (10.8–22.1% at the site-level) with > 98% probability across diverse locations. Finally, we document critical barriers to scaling software-as-a-service (SaaS) solutions–such as API instability and diverse legacy systems–and offer practical strategies to accelerate the commercial adoption of grid-interactive efficient buildings.

Ham, Sang Woo↗

NRWAL (NLR formerly known as NREL Wind Analysis Library) [SWR-21-26]

NRWAL (NLR (National Laboratory of the Rockies) formerly known as NREL (National Renewable Energy Laboratory) Wind Analysis Library: A library of offshore wind cost equations (plus new energy technologies like marine hydro!) Easy equation manipulation without editing source code Full continental-scale integration with the NREL Renewable Energy Potential Model (reV) https://nrel.github.io/reV/ Ready-to-use configs for basic users Dynamic python tools for intuitive equation handling One seriously badass sea unicorn To get started with NRWAL, check out the NRWAL Config documentation or the NRWAL example notebook. You can also launch the notebook in an interactive jupyter shell right in your browser without any downloads or software using binder. Ready to build a model with NRWAL but don't want to contribute to the library? No problem! Check out the example getting started project here. Here is the important stuff: The NRWAL Equation Library. Default NRWAL Configs

Nunemaker, Jacob↗

Resonance Ionization Spectroscopy Experiment at Facility for Rare Isotope Beams

This manuscript reports on the commissioning of the Resonance Ionization Spectroscopy Experiment (RISE) at the BEam COoler and LAser spectroscopy (BECOLA) facility at Facility for Rare Isotope Beams (FRIB). The instrument implements the collinear resonance ionization spectroscopy technique for sensitive measurements of isotope shifts and hyperfine structure of short-lived isotopes produced at FRIB. The existing BECOLA beamline was extended to integrate an electrostatic ion-beam bender and an ion detector at ultrahigh vacuum. An injection-seeded titanium-sapphire laser and a multiharmonic pulsed neodymium-doped yttrium aluminum garnet laser were installed to perform resonant excitation and selective ionization. Commissioning tests were performed to demonstrate the capabilities of the instrument by measuring the hyperfine structure of stable 27 Al produced in an offline ion source. The RISE instrument is ready and operational for future studies of short-lived isotopes at FRIB.

Atomic spectra↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fluoride-Cooled High-Temperature Pebble-Bed Reactor Reference Plant Model Updates

This work presents the latest improvements to, and investigations performed with, the Fluoride-Cooled High-Temperature Pebble-Bed Reactor reference plant models for the United States Nuclear Regulatory Commission. These models, developed with the Comprehensive Reactor Analysis Bundle, or BlueCRAB, serve as the foundation for the future development of detailed design evaluation models based on license applications. BlueCRAB is the code suite proposed for non-light-water reactor systems safety analyses, and it incorporates various simulation tools developed by the Nuclear Energy Advance Modeling and Simulation program, including the Griffin code for reactor physics, the Pronghorn and SAM codes for core thermal fluids, the BISON code for solid conduction and fuel performance, and the SAM code for system analysis. The primary objective of this work is to assess the level of readiness of BlueCRAB for modeling fluoride-cooled high-temperature pebble-bed reactors. We first developed numerical models in BlueCRAB that include the key physics for this technology, ensuring an adequate level of fidelity for modeling the core performance during accident scenarios. This was followed by simulation of transient scenarios, two loss-of-forced-cooling events (one protected and one unprotected), and two control rod withdrawal events (one delayed and one prompt supercritical reactivity insertion). The analysis includes comparisons between the 2-D thermal fluid porous media models in Pronghorn and SAM, comparisons between coupled Pronghorn-Griffin and coupled SAM-Griffin models for two loss-of-forced cooling events and one control rod withdrawal event, and comparisons between SAM single-solve and domain-overlapping approaches for multi-scale thermal fluid coupling. In addition, we performed comparisons between 3-D, 2-D, and 0-D neutronic models for the two control rod withdrawal scenarios with Pronghorn-Griffin. The results show that the BlueCRAB models led to physically intuitive solutions for the scenarios examined. The changes in the various scalar and vector fields such as the neutron flux, power, temperatures, densities, pressures, and velocities are all within the expected ranges, and their distributions can be explained from the system response of the transients and the geometric and material variations. Several comparisons suggest that the porous media models in Pronghorn and SAM can lead to similar solutions, even though they are based on different methodologies. The simulations demonstrate that there are differences between the various levels of fidelity, and it is advisable to have flexible tools that can cover the breadth and depth of needs that may arise in future technical evaluations. We believe that BlueCRAB’s capabilities represent a significant asset for confirmatory analyses aimed at resolving important safety questions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Foil Bearing Supported Compressor-Expander

R&D Dynamics Corporation (RDD) is developing a fuel cell system compressor-expander designed for heavy-duty vehicle applications. The system emphasizes high reliability, versatility, long service life, and cost-effective mass production. Its design integrates a high-speed centrifugal compressor/expander, oil-free foil air/gas bearings, a direct current permanent magnet (DCPM) motor, and an inverter utilizing silicon carbide (SiC) switches. Key advantages include high efficiency, compact size and reduced weight, enhanced reliability, and elimination of oil contamination risks. The technology targets multiple sectors such as long-haul semi-trucks, mining and construction equipment, power generation, data centers, marine systems, and other heavy machinery. Evaluation units are ready for shipment, and manufacturing capabilities are currently being developed. Contract Number: DE-EE0009617 (2021).

30 DIRECT ENERGY CONVERSION↗