Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

SU-G-JeP1-01: A Combination of Real Time Electromagnetic Localization and Tracking with Cone Beam Computed Tomography in Stereotactic Radiosurgery for Brain Tumors

Purpose: 1. online verification of patient position during treatment using calypso electromagnetic localization and tracking system. 2. Verification and comparison of positional accuracy between cone beam computed tomography and calypso system. 3. Presenting the advantage of continuation localization in Stereotactic radiosurgery treatments. Methods: Ten brain tumor cases were taken for this study. Patients with head mask were under gone Computed Tomography (CT). Before scanning, mask was cut on the fore head area to keep surface beacons on the skin. Slice thickness of 0.65 mm were taken for this study. x, y, z coordinates of these beacons in TPS were entered into tracking station. Varian True Beam accelerator, equipped with On Board Imager was used to take Cone beam Computed Tomography (CBCT) to localize the patient. Simultaneously Surface beacons were used to localize and track the patient throughout the treatment. The localization values were compared in both systems. For localization CBCT considered as reference. Tracking was done throughout the treatment using Calypso tracking system using electromagnetic array. This array was in tracking position during imaging and treatment. Flattening Filter free beams of 6MV photons along with Volumetric Modulated Arc Therapy was used for the treatment. The patient movement was observed throughout the treatment ranging from 2 min to 4 min. Results: The average variation observed between calypso system and CBCT localization was less than 0.5 mm. These variations were due to manual errors while keeping beacon on the patient. Less than 0.05 cm intra-fraction motion was observed throughout the treatment with the help of continuous tracking. Conclusion: Calypso target localization system is one of the finest tools to perform radiosurgery in combination with CBCT. This non radiographic method of tracking is a real beneficial method to treat patients confidently while observing real-time motion information of the patient.

60 APPLIED LIFE SCIENCES↗

The Response of Polarized Protons in Solid Hydrogen-Deuteride(HD) to Electron Beams

Solid frozen-spin polarized targets of hydrogen-deuteride(HD) have been proven advantageous in photon beam experiments, where they exhibit immeasurably long spin-relaxation times(T1). The present research investigates their potential applicability to experiments with minimum-ionizing charged-particle beams. Studies have been conducted with sub-nanoAmp CW currents of 10 MeV electron beams at the newly commissioned Upgraded Injector Test Facility (UITF) at Jefferson Lab (JLab). Since the energy deposition is almost independent of electron beam energy, these UITF experiments provide insight on the expected performance at the GeV energies required in typical JLab experiments. A horizontal in-beam dilution refrigerator equipped with superconducting solenoids has been used to maintain solid HD samples at about 0.1K and 1 Tesla. NMR coils sur rounding the HD target have been used to monitor hydrogen polarization. Thermal equilibrium polarizations of targets not in the frozen-spin state (with intentionally short T1) have been used to deduce the in situ temperature of solid HD while under electron bombardment. The behavior of a 40% H-polarized frozen-spin target has been tracked while exposed to beams under various conditions. Polarization loss has been observed to be approximately proportional to dose, with the target polarization dropping to 1/e of its initial value after about 6 µC cm2 , about 4 ? 1013 beam particles/cm2 . A model for depolarization by beam-associated paramagnetic impurities largely accounts for the data, and suggests that improvements in heat removal could lead to significant increases in the in-beam T1

Wei, Kevin↗

Grasping objects autonomously in simulated KC-135 zero-g

The KC-135 aircraft was chosen for simulated zero gravity testing of the Extravehicular Activity Helper/retriever (EVAHR). A software simulation of the EVAHR hardware, KC-135 flight dynamics, collision detection and grasp inpact dynamics has been developed to integrate and test the EVAHR software prior to flight testing on the KC-135. The EVAHR software will perform target pose estimation, tracking, and motion estimation for rigid, freely rotating, polyhedral objects. Manipulator grasp planning and trajectory control software has also been developed to grasp targets while avoiding collisions.

Norsworthy, Robert S.↗

Charged Track Reconstruction for GlueX at Jefferson Lab

The GlueX detector currently under construction at Jefferson Lab is a large acceptance device designed to facilitate the search for hybrid mesons. In order to accomplish this program, both photons and charged particles need to be reconstructed with high efficiency. Forward-going charged particles are detected in the Forward Drift Chambers while tracks exiting the target at angles greater than ?20 degrees are detected in the Central Drift Chamber. Hits in both sets of detectors are associated into track segments that are linked together to form track candidates. These candidates are fit using the Kalman Filter formalism. The track reconstruction sequence from track finding through track fitting will be described. Single-track efficiencies and resolutions will be presented. Results for simulated events containing multiple charged particles relevant for the GlueX physics program will also be presented.

Taylor, Simon↗

An Improved Flow Cytometry Method For Precise Quantitation Of Natural-Killer Cell Activity

The ability to assess NK cell cytotoxicity using flow cytometry has been previously described and can serve as a powerful tool to evaluate effector immune function in the clinical setting. Previous methods used membrane permeable dyes to identify target cells. The use of these dyes requires great care to achieve optimal staining and results in a broad spectral emission that can make multicolor cytometry difficult. Previous methods have also used negative staining (the elimination of target cells) to identify effector cells. This makes a precise quantitation of effector NK cells impossible due to the interfering presence of T and B lymphocytes, and the data highly subjective to the variable levels of NK cells normally found in human peripheral blood. In this study an improved version of the standard flow cytometry assay for NK activity is described that has several advantages of previous methods. Fluorescent antibody staining (CD45FITC) is used to positively identify target cells in place of membranepermeable dyes. Fluorescent antibody staining of target cells is less labor intensive and more easily reproducible than membrane dyes. NK cells (true effector lymphocytes) are also positively identified by fluorescent antibody staining (CD56PE) allowing a simultaneous absolute count assessment of both NK cells and target cells. Dead cells are identified by membrane disruption using the DNA intercalating dye PI. Using this method, an exact NK:target ratio may be determined for each assessment, including quantitation of NK target complexes. Backimmunoscatter gating may be used to track live vs. dead Target cells via scatter properties. If desired, NK activity may then be normalized to standardized ratios for clinical comparisons between patients, making the determination of PBMC counts or NK cell percentages prior to testing unnecessary. This method provides an exact cytometric determination of NK activity that highly reproducible and may be suitable for routine use in the clinical setting.

Crucian, Brian↗

Initial Considerations for Navigation and Flight Dynamics of a Crewed Near-Earth Object Mission

A crewed mission to a Near-Earth Object (NEO) was recently identified as a NASA Space Policy goal and priority. In support of this goal, a study was conducted to identify the initial considerations for performing the navigation and flight dynamics tasks of this mission class. Although missions to a NEO are not new, the unique factors involved in human spaceflight present challenges that warrant special examination. During the cruise phase of the mission, one of the most challenging factors is the noisy acceleration environment associated with a crewed vehicle. Additionally, the presence of a human crew necessitates a timely return trip, which may need to be expedited in an emergency situation where the mission is aborted. Tracking, navigation, and targeting results are shown for sample human-class trajectories to NEOs. Additionally, the benefit of in-situ navigation beacons on robotic precursor missions is presented. This mission class will require a longer duration flight than Apollo and, unlike previous human missions, there will likely be limited communication and tracking availability. This will necessitate the use of more onboard navigation and targeting capabilities. Finally, the rendezvous and proximity operations near an asteroid will be unlike anything previously attempted in a crewed spaceflight. The unknown gravitational environment and physical surface properties of the NEO may cause the rendezvous to behave differently than expected. Symbiosis of the human pilot and onboard navigation/targeting are presented which give additional robustness to unforeseen perturbations.

Holt, Greg N.↗

CCD sensors for spacecraft optical navigation

The optical navigation process uses spaceborne measurements of the apparent direction vector from the spacecraft to a target body, (planet, satellite, star, etc.) to improve estimates of the spacecraft trajectory. Ground-based controllers assimilate the optical measurements, together with spacecraft radio-tracking data and target ephemeris data, to generate a best estimate of the trajectory relative to the target. The present paper deals with a development program supporting the use of (solid state) CCD (Charged Coupled Device) imagers for spacecraft navigation. It is shown that stars can be detected that are two to three magnitudes fainter than with an equivalent vidicon based instrument, that effects of global response nonuniformity and dark current spikes can be essentially eliminated from the data as a result of the reproducibility of both effects, and that charge trailing during readout of star image data can lead to position measurement errors.

Eisenman, A. R.↗

Pion Production from 5-15 GeV Beam for the Neutrino Factory Front-End Study

For the neutrino factory front-end study, the production of pions from a proton beam of 5-8 and 14 GeV kinetic energy on a Hg jet target has been simulated. The pion yields for two versions of the MARS15 code and two different field configurations have been compared. The particles have also been tracked from the target position down to the end of the cooling channel using the ICOOL code and the neutrino factory baseline lattice. The momentum-angle region of pions producing muons that survived until the end of the cooling channel has been compared with the region covered by HARP data and the number of pions/muons as a function of the incoming beam energy is also reported.

43 PARTICLE ACCELERATORS↗

Observing Solar System Objects with the James Webb Space Telescope

The James Webb Space Telescope (JWST) will have the capability to observe Solar System objects having apparent rates of motion up to 30 milliarcseconds/sec. The key science drivers are the study of Kuiper Belt Objects, asteroids, comets, and the outer planets and their moons at near and mid-infrared wavelengths. This poster presents the results from a recent study that defined the conceptual design for a capability for JWST to track and observe moving targets. We illustrate about how guide star acquisition and tracking wi11 be handled while retaining the efficient and flexible execution characteristics of JWST event-driven operations. We also show how the JWST pointing control system can readily support moving target observations. The characteristics of Solar System objects that can be observed by JWST are summarized along with descriptions of the major aspects of moving target science observation planning and on-board event-driven execution.

Sonneborn, George↗

GEOS-3 Doppler difference tracking

The Doppler difference method as applied to track the GEOS 3 spacecraft is discussed. In this method a pair of 2 GHz ground tracking stations simultaneously track a spacecraft beacon to generate an observable signal in which bias and instability of the carrier frequency cancel. The baselines are formed by the tracking sites at Bermuda, Rosman, and Merritt Island. Measurements were made to evaluate the effectiveness of the Doppler differencing procedure in tracking a beacon target with the high dynamic rate of the GEOS 3 orbit. Results indicate the precision of the differenced data to be at a level comparable to the conventional precise two way Doppler tracking.

Rosenbaum, B.↗

Electromagnetic Detection and Real-Time DMLC Adaptation to Target Rotation During Radiotherapy

Purpose: Intrafraction rotation of more than 45 Degree-Sign and 25 Degree-Sign has been observed for lung and prostate tumors, respectively. Such rotation is not routinely adapted to during current radiotherapy, which may compromise tumor dose coverage. The aim of the study was to investigate the geometric and dosimetric performance of an electromagnetically guided real-time dynamic multileaf collimator (DMLC) tracking system to adapt to intrafractional tumor rotation. Materials/Methods: Target rotation was provided by changing the treatment couch angle. The target rotation was measured by a research Calypso system integrated with a real-time DMLC tracking system employed on a Varian linac. The geometric beam-target rotational alignment difference was measured using electronic portal images. The dosimetric accuracy was quantified using a two-dimensional ion chamber array. For each beam, the following five delivery modes were tested: 1) nonrotated target (reference); 2) fixed rotated target with tracking; 3) fixed rotated target without tracking; 4) actively rotating target with tracking; and 5) actively rotating target without tracking. Dosimetric performance of the latter four modes was measured and compared to the reference dose distribution using a 3 mm/3% {gamma}-test. Results: Geometrically, the beam-target rotational alignment difference was 0.3 Degree-Sign {+-} 0.6 Degree-Sign for fixed rotation and 0.3 Degree-Sign {+-} 1.3 Degree-Sign for active rotation. Dosimetrically, the average failure rate for the {gamma}-test for a fixed rotated target was 11% with tracking and 36% without tracking. The average failure rate for an actively rotating target was 9% with tracking and 35% without tracking. Conclusions: For the first time, real-time target rotation has been accurately detected and adapted to during radiation delivery via DMLC tracking. The beam-target rotational alignment difference was mostly within 1 Degree-Sign . Dose distributions to fixed and actively rotating targets with DMLC tracking were significantly superior to those without tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effective declutter of complex flight displays using stereoptic 3-D cueing

The application of stereo technology to new, integrated pictorial display formats has been effective in situational awareness enhancements, and stereo has been postulated to be effective for the declutter of complex informational displays. This paper reports a full-factorial workstation experiment performed to verify the potential benefits of stereo cueing for the declutter function in a simulated tracking task. The experimental symbology was designed similar to that of a conventional flight director, although the format was an intentionally confused presentation that resulted in a very cluttered dynamic display. The subject's task was to use a hand controller to keep a tracking symbol, an 'X', on top of a target symbol, another X, which was being randomly driven. In the basic tracking task, both the target symbol and the tracking symbol were presented as red X's. The presence of color coding was used to provide some declutter, thus making the task more reasonable to perform. For this condition, the target symbol was coded red, and the tracking symbol was coded blue. Noise conditions, or additional clutter, were provided by the inclusion of randomly moving, differently colored X symbols. Stereo depth, which was hypothesized to declutter the display, was utilized by placing any noise in a plane in front of the display monitor, the tracking symbol at screen depth, and the target symbol behind the screen. The results from analyzing the performances of eight subjects revealed that the stereo presentation effectively offsets the cluttering effects of both the noise and the absence of color coding. The potential of stereo cueing to declutter complex informational displays has therefore been verified; this ability to declutter is an additional benefit from the application of stereoptic cueing to pictorial flight displays.

Parrish, Russell V.↗

Functionalized PEI Nanoparticles For Delivery Of IGF-1R-Targeted siRNA's to UPAR-Expressing Tumors In Vitro And In Vivo

This proposal addressed the use of imaging technologies to develop therapeutic nanoparticle constructs which could reduce expression of molecules within the cancer cell important in tumor progression. The proposal described new labeling techniques that would result in therapeutic constructs which could be tracked both within targeted cells individually as well as within the individuals being treated. Representing a new generation of dual-labeled in vivo imaging agent, the constructs envisioned here would allow microPET imaging of targeted receptor expression as well as fluorescent imaging of silencing complexes targeting IGF-1R mRNA's. As such, this proposal was highly relevant to the Office of Biological and Environmental Research (BER) goals of facilitating improvements in radiotracer design in order to solve critical problems in biology and nuclear medicine.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Image Moment-Based Extended Object Tracking for Complex Motions

A novel image moment-based model for shape estimation and tracking of an extended target moving with a complex trajectory is presented. The proposed extended object tracking algorithm is based on multiple noisy measurement points sampled from the target at each time step. The shape of the object, approximated by an ellipse, is estimated using a combination of image moments. Dynamic models of image moments for constant velocity and coordinated turn motions are mathematically derived. An unscented Kalman filter - interacting multiple model (UKF-IMM) method is used to track the object and estimate its shape. A likelihood function based on average log-likelihood is derived for the IMM filter. Simulation results of the proposed UKF-IMM algorithm with the image momentbased models are presented that show the estimation of the shape of the object moving in a complex trajectory. The intersection over union (IoU), and the root mean square errors (RMSEs) of the position and velocity of the centroid of the ellipse are used as metrics. The comparison results of the proposed algorithm with a benchmark algorithm from literature based on the IoU and RMSE metrics are presented.

Extended object tracking↗

A model for the pilot's use of motion cues in roll-axis tracking tasks

Simulated target-following and disturbance-regulation tasks were explored with subjects using visual-only and combined visual and motion cues. The effects of motion cues on task performance and pilot response behavior were appreciably different for the two task configurations and were consistent with data reported in earlier studies for similar task configurations. The optimal-control model for pilot/vehicle systems provided a task-independent framework for accounting for the pilot's use of motion cues. Specifically, the availability of motion cues was modeled by augmenting the set of perceptual variables to include position, rate, acceleration, and accleration-rate of the motion simulator, and results were consistent with the hypothesis of attention-sharing between visual and motion variables. This straightforward informational model allowed accurate model predictions of the effects of motion cues on a variety of response measures for both the target-following and disturbance-regulation tasks.

Levison, W. H.↗