Phase stability and interlayer interaction of blue phosphorene

In this work, we study the interlayer interactions between sheets of blue phosphorus with quantum Monte Carlo (QMC) methods. Here, we find that as previously observed in black phosphorus, interlayer binding of blue phosphorus cannot be described by van der Waals (vdW) interactions alone within the density functional theory framework. Specifically, while some vdW density functionals produced reasonable binding curves, none of them could provide a correct, even qualitatively, description of charge redistribution due to interlayer binding. We also show that small systematic errors in common practice QMC calculations, such as the choice of optimized geometry and finite-size corrections, are non-negligible given the energy and length scales of this problem. We mitigate some of the major sources of error and report QMC-optimized lattice constant, stacking, and interlayer binding energy for blue phosphorus. Finally, it is strongly suggested that these considerations are important and quite general in the modeling of two-dimensional phosphorus allotropes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring Alignments between Galaxies and the Cosmic Web at z ∼ 2–3 Using IGM Tomography

Many galaxy formation models predict alignments between galaxy spin and the cosmic web (i.e., directions of filaments and sheets), leading to an intrinsic alignment between galaxies that creates a systematic error in weak-lensing measurements. These effects are often predicted to be stronger at high redshifts (z ≳ 1) that are inaccessible to massive galaxy surveys on foreseeable instrumentation, but IGM tomography of the Lyα forest from closely spaced quasars and galaxies is starting to measure the z ∼ 2–3 cosmic web with requisite fidelity. Using mock surveys from hydrodynamical simulations, we examine the utility of this technique, in conjunction with coeval galaxy samples, to measure alignment between galaxies and the cosmic web at z ∼ 2.5. We show that IGM tomography surveys with ≲5 h {sup −1} Mpc sightline spacing can accurately recover the eigenvectors of the tidal tensor, which we use to define the directions of the cosmic web. For galaxy spins and shapes, we use a model parameterized by the alignment strength, Δ〈cos θ〉, with respect to the tidal tensor eigenvectors from the underlying density field, and also consider observational effects such as errors in the galaxy position angle, inclination, and redshift. Measurements using the upcoming ∼1 deg{sup 2} CLAMATO tomographic survey and 600 coeval zCOSMOS-Deep galaxies should place 3σ limits on extreme alignment models with Δ〈cos θ〉∼0.1, but much larger surveys encompassing >10,000 galaxies, such as Subaru PFS, will be required to constrain models with Δ〈cos θ〉∼0.03. These measurements will constrain models of galaxy–cosmic web alignment and test tidal torque theory at z ∼ 2, improving our understanding of the physics of intrinsic alignments.

79 ASTRONOMY AND ASTROPHYSICS↗

Light curves of 213 Type Ia supernovae from the Essence survey

The ESSENCE survey discovered 213 Type Ia supernovae at redshifts $0.1\lt z\lt 0.81$ between 2002 and 2008. We present their R- and I-band photometry, measured from images obtained using the MOSAIC II camera at the CTIO Blanco, along with rapid-response spectroscopy for each object. We use our spectroscopic follow-up observations to determine an accurate, quantitative classification, and precise redshift. Through an extensive calibration program we have improved the precision of the CTIO Blanco natural photometric system. We use several empirical metrics to measure our internal photometric consistency and our absolute calibration of the survey. Here, we assess the effect of various potential sources of systematic bias on our measured fluxes, and estimate the dominant term in the systematic error budget from the photometric calibration on our absolute fluxes is ~1%.

79 ASTRONOMY AND ASTROPHYSICS↗

Extending the limits of powder diffraction analysis: diffraction parameter space, occupancy defects, and atomic form factors

Although the determination of site occupancies is often a major goal in Rietveld refinement studies, the accurate refinement of site occupancies is exceptionally challenging due to the many correlations and systematic errors that have a hidden impact on the final refined occupancy parameters. Through the comparison of results independently obtained from neutron and synchrotron powder diffraction, improved approaches capable of detecting occupancy defects with an exceptional sensitivity of 0.1% (absolute) in the class of layered NMC Li-ion battery cathode materials have been developed. A new method of visualizing the diffraction parameter space associated with crystallographic site scattering power through the use of f* diagrams is described and this method is broadly applicable to ternary compounds. The f* diagrams allow the global minimum fit to be easily identified and also permit a robust determination of the number and type of occupancy defects within a structure. Through a comparison of neutron and X-ray diffraction results, a systematic error in the synchrotron results was identified using f* diagrams for a series of NMC compounds. Using neutron diffraction data as a reference, this error was shown to specifically result from problems associated with the neutral oxygen X-ray atomic form factor and could be eliminated by using the ionic O 2- form factor for this anion while retaining the neutral form factors for cationic species. The f* diagram method offers a new opportunity to experimentally assess the quality of atomic form factors through powder diffraction studies on chemically related multi-component compounds.

25 ENERGY STORAGE↗

Uncertainty Analysis of Seebeck Coefficient and Electrical Resistivity Characterization

In order to provide a complete description of a materials thermoelectric power factor, in addition to the measured nominal value, an uncertainty interval is required. The uncertainty may contain sources of measurement error including systematic bias error and precision error of a statistical nature. The work focuses specifically on the popular ZEM-3 (Ulvac Technologies) measurement system, but the methods apply to any measurement system. The analysis accounts for sources of systematic error including sample preparation tolerance, measurement probe placement, thermocouple cold-finger effect, and measurement parameters; in addition to including uncertainty of a statistical nature. Complete uncertainty analysis of a measurement system allows for more reliable comparison of measurement data between laboratories.

Seebeck effect↗

Cosmic Voids in the SDSS DR12 BOSS Galaxy Sample: the Alcock–Paczyński test

We apply the Alcock–Paczyński (AP) test to stacked voids identified using the final data release (DR12) of the Baryon Oscillation Spectroscopic Survey (BOSS). We also use 1000 mock galaxy catalogs that match the geometry, density, and clustering properties of the BOSS sample in order to characterize the statistical uncertainties of our measurements and take into account systematic errors such as redshift space distortions. For both BOSS data and mock catalogs, we use the ZOBOV algorithm to identify voids, we stack together all voids with effective radii of 30--100 h{sup −1} Mpc in the redshift range of 0.43–0.7, and we accurately measure the shape of the stacked voids. Our tests with the mock catalogs show that we measure the stacked void ellipticity with a statistical precision of 2.6%. The stacked voids in redshift space are slightly squashed along the line of sight, consistent with previous studies. We repeat this measurement of stacked void shape in the BOSS data, assuming several values of Ω{sub m} within the flat ΛCDM model, and we compare this to the mock catalogs in redshift space to perform the AP test. We obtain a constraint of Ω{sub m}=0.38{sub −0.15}{sup +0.18} at the 68% confidence level from the AP test. We discuss the sources of statistical and systematic noise that affect the constraining power of this method. In particular, we find that the measured ellipticity of stacked voids changes more weakly with cosmology than the standard AP prediction, leading to significantly weaker constraints. We discuss how constraints will improve in future surveys with larger volumes and densities.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for Lepton Flavor Violation in Two Body Muon and Pion Decay at Rest

The ability of the Mu2e experiment to probe, or discover beyond the Standard Model physics in direct Charged Lepton Flavor Violation $\mu^+$ and $\pi^+$ decay modes is estimated. These direct modes are searched for simultaneously with proposed Mu2e detector validation runs, and are complementary to the Mu2e main search goal, an indirect search for $\mu^- \to e^-$ conversion at the sensitivity level of $\sim 10^{-17}$. The $\mu^+$ validation run will operate at 50% nominal magnetic field and reduced proton beam intensity to less than 1/100th nominal, in order to observe the e+ spectrum from $\mu^+$ decay, at and below the Michel edge Ee . 53 MeV. The $\pi^+$ validation run, based on measuring the mono-energetic e+ emission in the decay $\pi^+ \to e+\nu$, at 76% of nominal magnetic field and reduced beam intensity less than 1/5th nominal. Both of these runs can be used to fix the momentum scale for the Mu2e conversion search. In addition the muon validation dataset can be used to correct for systematic errors in the detector response by mapping the well known to O(\u03B13) corrected theoretical Michel spectrum, to the observed spectrum. One direct search is for two-body Charged Lepton Flavor Violation $\mu^+ \to e^+X$ decay, where $X$ is a light new physics particle. This allows Mu2e to explore well motivated models including axion like particles with flavor violating couplings and massive $Z^0$ bosons with more sensitivity then present astrophysical and laboratory constraints. In two weeks of data-taking, Mu2e can achieve direct mode 90% confidence level branching ratio limits of $10^{-7}$ over the mass range $20 \le m_X \le 50$ MeV, improving the current experimental limit at $10^{-5}$ by two orders of magnitude. In the mass range $m_X \le 20$ MeV, assuming systematic error corrections can be made by correcting the Monte Carlo mapping, the achievable search sensitivity is found to be $2.3\times 10^{-7}$ for $m_X =0$, an order of magnitude improvement over the current best limit at $2.6\times 10^{-6}$, when assuming $V+A$ or isotropic coupling. The $\pi^+$ validation run, allows searching for $\pi^+ \to e^+N$ decay, where $N$ is a heavy neutral lepton such as a heavy sterile neutrino, in the mass region $20 \le m_N \le 65$ MeV. A branching ratio limit at 90% confidence level of $3\times 10^{-8}$ can be achieved in two weeks, an improvement of the current search sensitivity limit by an order of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Seed Placement in Permanent Breast Seed Implant Brachytherapy: Are Concerns Over Accuracy Valid?

Purpose: To evaluate seed placement accuracy in permanent breast seed implant brachytherapy (PBSI), to identify any systematic errors and evaluate their effect on dosimetry. Methods and Materials: Treatment plans and postimplant computed tomography scans for 20 PBSI patients were spatially registered and used to evaluate differences between planned and implanted seed positions, termed seed displacements. For each patient, the mean total and directional seed displacements were determined in both standard room coordinates and in needle coordinates relative to needle insertion angle. Seeds were labeled according to their proximity to the anatomy within the breast, to evaluate the influence of anatomic regions on seed placement. Dosimetry within an evaluative target volume (seroma + 5 mm), skin, breast, and ribs was evaluated to determine the impact of seed placement on the treatment. Results: The overall mean (±SD) difference between implanted and planned positions was 9 ± 5 mm for the aggregate seed population. No significant systematic directional displacements were observed for this whole population. However, for individual patients, systematic displacements were observed, implying that intrapatient offsets occur during the procedure. Mean displacements for seeds in the different anatomic areas were not found to be significantly different from the mean for the entire seed population. However, small directional trends were observed within the anatomy, potentially indicating some bias in the delivery. Despite observed differences between the planned and implanted seed positions, the median (range) V{sub 90} for the 20 patients was 97% (66%-100%), and acceptable dosimetry was achieved for critical structures. Conclusions: No significant trends or systematic errors were observed in the placement of seeds in PBSI, including seeds implanted directly into the seroma. Recorded seed displacements may be related to intrapatient setup adjustments. Despite observed seed displacements, acceptable postimplant dosimetry was achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bottom-Hadron Mass Splittings from Static-Quark Action on 2+1-Flavor Lattices

We calculate bottom-baryon mass splittings using full QCD with 2+1 flavors of dynamical Kogut-Susskind sea quarks and domain-wall valence quarks along with a static heavy quark on a lattice of spatial volume of $(\sim 2.5\mbox{ fm})^3$ with lattice spacing of about 0.124~fm over a range of pion masses as low as 291~MeV. We calculate the mass splittings of bottom hadrons with respect to $B_d$ and $\Lambda_b$. Our results are in agreement with experimental observations and other lattice calculations, within our statistical and systematic errors. In particular, we find the mass of the $\Omega_b$ to be consistent with the recent CDF measurement. We also predict the mass for the as yet unobserved $\Xi^\prime_b$ to be 5955(27)~MeV.

43 PARTICLE ACCELERATORS↗

Transfer of autocollimator calibration for use with scanning gantry profilometers for accurate determination of surface slope and curvature of state-of-the-art x-ray mirrors

X-ray optics, desired for beamlines at free-electron-laser and diffraction-limited-storage-ring x-ray light sources, must have almost perfect surfaces, capable of delivering light to experiments without significant degradation of brightness and coherence. To accurately characterize such optics at an optical metrology lab, two basic types of surface slope profilometers are used: The long trace profilers (LTPs) and nanometer optical measuring (NOM) like angular deflectometers, based on electronic autocollimator (AC) ELCOMAT-3000. The inherent systematic errors of the instrument's optical sensors set the principle limit to their measuring performance. Where autocollimator of a NOM-like profiler may be calibrated at a unique dedicated facility, this is for a particular configuration of distance, aperture size, and angular range that does not always match the exact use in a scanning measurement with the profiler. Here we discuss the developed methodology, experimental set-up, and numerical methods of transferring the calibration of one reference AC to the scanning AC of the Optical Surface Measuring System (OSMS), recently brought to operation at the ALS Xray Optics Laboratory. We show that precision calibration of the OSMS performed in three steps, allows us to provide high confidence and accuracy low-spatial-frequency metrology and not â€print into' measurements the inherent systematic error of tool in use. Here, with the examples of the OSMS measurements with a state-of-The-Art x-ray aspherical mirror, available from one of the most advanced vendors of X-ray optics, we demonstrate the high efficacy of the developed calibration procedure. The results of our work are important for obtaining high reliability data, needed for sophisticated numerical simulations of beamline performance and optimization of beamline usage of the optics. This work was supported by the U. S. Department of Energy under contract number DE-AC02-05CH11231.

47 OTHER INSTRUMENTATION↗

Efficient Methods to Assimilate Satellite Retrievals Based on Information Content: Suboptimal Retrieval Assimilation - Part 2

One of the outstanding problems in data assimilation has been and continues to be how best to utilize satellite data while balancing the tradeoff between accuracy and computational cost. A number of weather prediction centers have recently achieved remarkable success in improving their forecast skill by changing the method by which satellite data are assimilated into the forecast model from the traditional approach of assimilating retrievals to the direct assimilation of radiances in a variational framework. The operational implementation of such a substantial change in methodology involves a great number of technical details, e.g., pertaining to quality control procedures, systematic error correction techniques, and tuning of the statistical parameters in the analysis algorithm. Although there are clear theoretical advantages to the direct radiance assimilation approach, it is not obvious at all to what extent the improvements that have been obtained so far can be attributed to the change in methodology, or to various technical aspects of the implementation. The issue is of interest because retrieval assimilation retains many practical and logistical advantages which may become even more significant in the near future when increasingly high-volume data sources become available. The central question we address here is: how much improvement can we expect from assimilating radiances rather than retrievals, all other things being equal? We compare the two approaches in a simplified one-dimensional theoretical framework, in which problems related to quality control and systematic error correction are conveniently absent. By assuming a perfect radiative transfer model and perfect knowledge of radiance and background error covariances, we are able to formulate a nonlinear local error analysis for each assimilation method. Direct radiance assimilation is optimal in this idealized context, while the traditional method of assimilating retrievals is suboptimal because it ignores the cross-covariances between background errors and retrieval errors. We show that interactive retrieval assimilation (where the same background used for assimilation is also used in the retrieval step) is equivalent to direct assimilation of radiances with suboptimal analysis weights. We illustrate and extend these theoretical arguments with several one-dimensional assimilation experiments, where we estimate vertical atmospheric profiles using simulated data from both the High-resolution InfraRed Sounder 2 (HIRS2) and the future Atmospheric InfraRed Sounder (AIRS).

Joiner, J.↗

Systematic improvement of x -dependent unpolarized nucleon generalized parton distributions in lattice-QCD calculation

We present a first study of the effects of renormalization-group resummation (RGR) and leading-renormalon resummation (LRR) on the systematic errors of the unpolarized isovector nucleon generalized parton distribution in the framework of large-momentum effective theory. This work is done using lattice gauge ensembles generated by the MILC Collaboration, consisting of 2 + 1 + 1 flavors of highly improved staggered quarks with a physical pion mass at lattice spacing a ≈ 0.09 fm and a box width L ≈ 5.76 fm . We present results for the nucleon H and E generalized parton distributions (GPDs) with average boost momentum P z ≈ 2 GeV at momentum transfers Q 2 = [ 0 , 0.97 ] GeV 2 at skewness ξ = 0 as well as Q 2 ∈ 0.23 GeV 2 at ξ = 0.1 , renormalized in the modified minimal subtraction ( MS ¯ ) scheme at scale μ = 2.0 GeV , with two- and one-loop matching, respectively. We demonstrate that the simultaneous application of RGR and LRR significantly reduces the systematic errors in renormalized matrix elements and distributions for both the zero and nonzero skewness GPDs, and that it is necessary to include both RGR and LRR at higher orders in the matching and renormalization processes. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Comparing Measured (a,n) Thick Target Yields to MCNP6 using TENDL 2012 Libraries - Paper 31

MCNP6, due to the heritage of MCNPX, has always possessed the capability to transport the light ions, such as alpha particles. Two types of competing physics take place during the particle transport: atomic and nuclear physics. Charged particles lose energy to media due to Coulombic interactions. MCNP6 models Coulombic interactions through the use of the continuous slowing down approximation. Stopping powers are calculated at a variety of energies using the Bethe-Bloch formula with Sternheimer and Peierls density effect correction. For energies less than 1.31 MeV/AMU, a low-energy SPAR model is used. When the energy of the particle is high enough, there is a transition from nuclear interactions to nucleon interactions. MCNP6 possess various physics models to account for these types of intra-nuclear cascades. These models are less accurate at low energies. Even though MCNP6 will transport these light ions to low energies (i.e. less than 20 MeV), most of the available model physics in MCNP6, for nuclear interactions, has a suggested minimum energy of ∼20-200 MeV. The result of the poorer prediction at low energies causes important light ion events, such as F-19(a,n)Na-22 from U-234 decay in UF{sub 6}, to produce orders of magnitude fewer neutrons in MCNP6 than should be emitted. As with neutrons, ACE (A Compact ENDF) formatted light ion libraries have been developed from several different evaluations. These libraries possess better physics at low energies where the physics models break down. The TENDL 2012 evaluations possess alpha transport libraries, in ACE format, such that they can easily be used with codes like MCNP6 that read ACE formatted cross sections. As a result, a capability was developed for MCNP6 to read and implement these library cross sections when the light ion reached energies below the library upper energy cutoff. Perfectly modelling an experiment for benchmark comparisons to a code calculation can be tricky. For complex setups, systematic error is always possible; and usually a hefty uncertainty analysis is required to quantify just the geometry setup and material combination choices. For an (a,n) interaction, a thick target yield is defined as the amount of neutrons emitted given that the alpha ranges out in the material. For alpha transport at low energy <10 MeV, in reasonably dense materials (>1-2 g/cc), with a material dimension length larger than a few hundred microns, alpha particles will tend to completely stop and range out in the material. For Li, Be, B, C, N, O, F, Na, Mg and Al thick target yields exist in 200 keV intervals from 1 to 9.8 MeV (most of the elements do have (a,n) thresholds above 1 MeV). Because modelling a thick target yield in MCNP6 is much easier than attempting to account for the complexity of systematic error from a full out experiment, we present here comparisons of (a,n) thick target yields to those calculated in MCNP6 using the TENDL 2012 alpha library evaluations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mercury's Global Topography from Radar Ranging Data

When Mercury's radius is expanded in Legendre functions to the second degree and order, the systematic error in radar ranging data is reduced substantially. Previously, data spanning an observing interval from 1966 to 1990 were used to infer an equatorial ellipticity (a - b)/a = (540 +/- 54) X 10(exp -6) and a center-of-figure minus center-of-mass offset of (640 +/- 78) m. The magnitude of this equatorial center of figure offset implies an excess crustal thickness of 12 km or less, comparable to the Moon's excess. By comparing the equatorial ellipticity with the Mariner 10 gravity field, and assuming Airy isostatic compensation, bounds on crustal thickness can be derived. Mercury's crustal thickness is in the range from 100 to 300 km. The Mercury radar ranging observing interval has been extended from 1966 to the present. In addition, improvements in data reduction techniques have resulted in a set of Mercury ranging data less affected by systematic error, in particular the biases introduced by local topographic variations. We use this new set of reduced ranging data to improve Mercury's global topography and center-of-figure minus center-of-mass offset. New results on crustal thickness are derived, and prospects for further improvement with Mercury Orbiter data are discussed.

Anderson, J. D.↗

Fundamental High-Pressure Calibration from All-Electron Quantum Monte Carlo Calculations

We develop an all-electron quantum Monte Carlo (QMC) method for solids that does not rely on pseudopotentials, and use it to construct a primary ultra-high-pressure calibration based on the equation of state of cubic boron nitride. We compute the static contribution to the free energy with the QMC method and obtain the phonon contribution from density functional theory, yielding a high-accuracy calibration up to 900 GPa usable directly in experiment. We compute the anharmonic Raman frequency shift with QMC simulations as a function of pressure and temperature, allowing optical pressure calibration. In contrast to present experimental approaches, small systematic errors in the theoretical EOS do not increase with pressure, and no extrapolation is needed. This all-electron method is applicable to first-row solids, providing a new reference for ab initio calculations of solids and benchmarks for pseudopotential accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Qweak experiment: a precision measurement of the proton's weak charge

The Qweak experiment will conduct the first precision measurement of the weak charge of the proton, Q{sub W}{sup p}, at Jefferson Laboratory, building on the technical advances that have been made in the laboratory's parity-violation program and using the results of earlier measurements to constrain hadronic corrections. When the results from this measurement are combined with atomic-parity violation and other PVES measurements the weak charges of the 'up' and 'down' quarks can be extracted. The experiment is basically a measurement of the parity-violating longitudinal analyzing power in e-p elastic scattering at Q{sup 2} = 0.026 (GeV/c){sup 2} employing 150 {mu}A's of 85% polarized electrons on a 0.35 m long liquid hydrogen target. The experiment will determine the weak charge of the proton with about 4.1% combined statistical and systematic errors. This corresponds to constraints on parity violating new physics at a mass scale of 2.3 TeV at the 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determining the tilt of the Raman laser beam using an optical method for atom gravimeters

The tilt of a Raman laser beam is a major systematic error in precision gravity measurement using atom interferometry. The conventional approach to evaluating this tilt error involves modulating the direction of the Raman laser beam and conducting time-consuming gravity measurements to identify the error minimum. In this work, we demonstrate a method to expediently determine the tilt of the Raman laser beam by transforming the tilt angle measurement into characterization of parallelism, which integrates the optical method of aligning the laser direction, commonly used in freely falling corner-cube gravimeters, into an atom gravimeter. A position-sensing detector (PSD) is utilized to quantitatively characterize the parallelism between the test beam and the reference beam, thus measuring the tilt precisely and rapidly. After carefully positioning the PSD and calibrating the relationship between the distance measured by the PSD and the tilt angle measured by the tiltmeter, we achieved a statistical uncertainty of less than 30 µrad in the tilt measurement. Furthermore, we compared the results obtained through this optical method with those from the conventional tilt modulation method for gravity measurement. The comparison validates that our optical method can achieve tilt determination with an accuracy level of better than 200 µrad, corresponding to a systematic error of 20 µGal in g measurement. This work has practical implications for real-world applications of atom gravimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A synthetic diagnostic for validation of electron gyroradius scale turbulence simulations against coherent scattering measurements

Comparison between spectra of short-scale density fluctuations measured with coherent electromagnetic scattering experiments and those extracted from space-resolved numerical simulations is affected by a number of systematic errors. These include the locality of scattering measurements, the different domain covered (space-resolved simulations versus wavenumber resolved measurements), and the stationarity of simulated nonlinear spectra. To bridge the gap between theory-simulations and experiments, a synthetic diagnostic for high- k scattering measurements has been developed. This synthetic scattering predicts the propagation of the beam in an anisotropic, inhomogeneous plasma and accounts for the spatial variation of the instrumental transfer function. Here the latter, in particular, is proven to provide an important calibration factor not only for the simulated spectra, but also for the measured ones, allowing the use of the synthetic diagnostic in predictive mode. Results from a case study for National Spherical Torus Experiment plasmas using high- k</em. tangential scattering system and the gyrokinetic tokamak simulation code are presented.