Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Synchrotron based mass spectrometry to investigate the molecular properties of mineral-organic associations

Soil organic matter (OM) is important because its decay drives life processes in the biosphere. Analysis of organic compounds in geological systems is difficult because of their intimate association with mineral surfaces. To date there is no procedure capable of quantitatively separating organic from mineral phases without creating artifacts or mass loss. Therefore, analytical techniques that can (a) generate information about both organic and mineral phases simultaneously and (b) allow the examination of predetermined high-interest regions of the sample as opposed to conventional bulk analytical techniques are valuable. Laser Desorption Synchrotron Postionization (synchrotron-LDPI) mass spectrometry is introduced as a novel analytical tool to characterize the molecular properties of organic compounds in mineral-organic samples from terrestrial systems, and it is demonstrated that when combined with Secondary Ion Mass Spectrometry (SIMS), can provide complementary information on mineral composition. Mass spectrometry along a decomposition gradient in density fractions, verifies the consistency of our results with bulk analytical techniques. We further demonstrate that by changing laser and photoionization energies, variations in molecular stability of organic compounds associated with mineral surfaces can be determined. The combination of synchrotron-LDPI and SIMS shows that the energetic conditions involved in desorption and ionization of organic matter may be a greater determinant of mass spectral signatures than the inherent molecular structure of the organic compounds investigated. The latter has implications for molecular models of natural organic matter that are based on mass spectrometric information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchrotron X-ray-induced Synthesis of Copper Hydroxide Nitrate Nanoplates on Cu Thin Films in an Ambient Atmosphere

Synchrotron X-rays are widely used for material characterizations. However, they can also ionize atoms and molecules to damage and manipulate probed materials. We report here an X-ray-induced growth of copper hydroxide nitrate, Cu 2 (OH) 3 NO 3 , on copper thin films in the ambient atmosphere without solvents and thermal treatment. In situ synchrotron X-ray diffraction measurements showed that the time-dependent growth process of the Cu 2 (OH) 3 NO 3 is accompanied by the consumption of Cu metal and can be described by a sigmoidal model. The growth rate was reduced after the initial fast growth period. Scanning electron microscopy (SEM) images show that the isolated islands of Cu 2 (OH) 3 NO 3 nanoplates formed in the beginning, which grew together with new nanoplates formed under continued X-ray irradiation. The result demonstrated that high-flux synchrotron X-rays may provide an unconventional approach to synthesizing and manipulating materials, which will inspire future investigation both experimentally and theoretically.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time microstructure of shocked LiF crystals: Use of synchrotron x-rays

We describe the use of a third generation synchrotron facility to obtain in situ, real-time, x-ray diffraction measurements in plate impact experiments. Subnanosecond duration x-ray pulses were utilized to record diffraction data from pure and magnesium-doped LiF single crystals shocked along the [111] and [100] orientations. The peak stresses were 3.0 GPa for the [111] oriented LiF and between 3.0 and 5.0 GPa for the [100] oriented LiF. For these stresses, shock compression along [111] results in elastic deformation and shock compression along [100] results in elastic-plastic deformation. Because of the quality of the synchrotron x-ray pulses, both shifting and broadening of the diffraction data were obtained simultaneously. As expected, shifts for elastic compression and elastic-plastic compression in shocked LiF were consistent with uniaxial and isotropic lattice compression, respectively. More importantly, diffraction patterns from crystals shocked along [100] exhibited substantial broadening due to elastic-plastic deformation. The broadening indicates that the shocked LiF(100) crystals developed substructure with a characteristic size for coherently diffracting domains (0.1-10{micro}m) and a distribution of (100) microlattice-plane rotations ({approx} 1{sup o} wide). In contrast to the LiF(100) results, broadening of the diffraction pattern did not occur for elastically deformed LiF(111). Another important finding was that the amount of lattice disorder for shocked LiF(100) depends on the loading history; the broadening was larger for the magnesium-doped LiF(100) (large elastic precursor) than for ultrapure LiF(100) (small elastic precursor) shocked to the same peak stress. The data are simulated by calculating the diffraction pattern from LiF(100) with a model microstructure consisting of coherently diffracting domains. The lattice orientation and longitudinal strain is assumed uniform within domains, but they vary from domain to domain with Gaussian distributions. Simulations using such a model are in good agreement with the measured diffraction patterns. The principal finding from the present work is that synchrotron x-rays can provide real-time data regarding microstructure changes accompanying shock-induced deformation and structural changes.

43 PARTICLE ACCELERATORS↗

Portable laser-heating stand for synchrotron applications

A compact, double-sided laser-heating system for diamond-cell synchrotron applications is described. The optical table, containing laser, spectrometer, and all optics for visual observation and measuring temperatures and pressures has an area of less than (1/2) m{sup 2} and weighs less than 20 kg. All components can be remotely controlled at micron levels with simple dc motors and pneumatic drives. The design allows quick alignment of the laser-heated hot spot with the x-ray beam and the spectrometer. The prealigned system can be set up at most synchrotron beamlines within about 1 h. We carried out measurements on a variety of materials above one megabar and up to over 4000 K at both the x-ray diffraction beamline ID 27 and the x-ray absorption beamline ID 24 at the European Synchrotron Facility. A new measurement of the melting temperature of iron by x-ray absorption spectroscopy is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipurpose furnace for in situ studies of polycrystalline materials using synchrotron radiation

We report a multipurpose furnace designed for studies using synchrotron radiation on polycrystalline materials, namely, metals, ceramics, and (semi)crystalline polymers. The furnace has been designed to carry out three-dimensional (3D) x-ray diffraction measurements but can also be used for other types of synchrotron radiation research. The furnace has a very low thermal gradient across the specimen (<0.2 degree sign C/mm). Accurate determination of the temperature can be carried out by welding a thermocouple to the specimen. The furnace can be rotated over an angle of 90 degree sign in order to determine the crystallographic orientation of each individual grain. It is possible to follow growth kinetics of all grains in the illuminated volume of the specimen. The specimen environment can be controlled varying from vacuum (up to 10{sup -5} mbar) to gas or air filled. The maximum temperature of operation is 1500 degree sign C, with the possibility of achieving high heating (up to 20 deg. C/s) and cooling rates (up to 30 deg. C/s without quenching gas). 3D maps of the microstructure of the specimen can be generated at elevated temperatures by bringing the high-resolution detector close to the specimen. We show an example of a simulation of the heat affected zone during the thermal cycle of a weld in a transformation-induced plasticity steel carried out using the furnace. The unique characteristics of the furnace open possibility of new fields in materials research using synchrotron radiation.

36 MATERIALS SCIENCE↗

DAFNE-Light INFN-LNF Synchrotron Radiation Facility

DAFNE-Light is the Synchrotron Radiation Facility at the INFN-Frascati National Laboratory (Rome, Italy). Three beamlines are operational, using in parasitic and dedicated mode the intense photon emission of DAFNE, a 0.51 GeV storage ring with a routinely circulating electron current higher than 1 Ampere. Two of these beamlines--the soft x-ray (DXR1) and UV (DXR2)--use one of the DAFNE wiggler magnets as synchrotron radiation source, while the third beamline SINBAD (Synchrotron Infrared Beamline At DAFNE) collects the radiation from a bending magnet. New XUV bending magnet beamlines are nowadays under construction and the low energy one (35-200 eV) will be ready for commissioning by the end of 2009. A presentation of the facility will be given together with some recent scientific results achieved at SINBAD and DXR1 beamlines.

43 PARTICLE ACCELERATORS↗

Uncertainty of Radiant Power Calibration based on Synchrotron Radiation caused by Spectral Distribution and Polarization State

We have been attempting to establish an absolute scale of spectral radiance in ultraviolet and vacuum ultraviolet regions by using synchrotron radiation as a primary standard light source and also attempting to transfer the absolute scale to an under-test light source by comparing the under-test source with synchrotron radiation. The calibration apparatus does not function as ideal comparator because some properties of incident radiation, which are spectral distribution and polarization state, are different between synchrotron radiation and the under-test light source, and the signal of the apparatus accordingly depends on not only spectral radiant power but also depends on the properties of the incident radiation. We evaluated how the detector signal ratio was affected by the difference both experimentally and theoretically, and also evaluated the uncertainty of the scale transfer caused by the difference.

43 PARTICLE ACCELERATORS↗

Bystander Effects During Synchrotron Imaging Procedures?

Using monochromatic beam and synchrotron phase-contrast technique at the biomedical beamline of the Italian synchrotron facility Elettra (SYRMEP), we have shown in a small animal model of malignant brain tumor that it is possible to obtain high-resolution images of very small tumors when they have developed from implanted tumor cells loaded with colloidal gold nanoparticles (GNP). All previous experiments were conducted in post-mortem samples. We have now designed a cell culture experiment to investigate the effects of synchrotron radiation with an energy and dose profile similar to that expected in our first in vivo imaging studies according to the protocol developed at SYRMEP.Materials and Methods: Culture flasks containing either gold-loaded or naieve C6 glioma cells were exposed to a dose of 0.5 Gy at 24 keV. The irradiated medium was aspirated and replaced with fresh growth medium. Twenty-four hours later this non-irradiated medium exposed to irradiated cells was aspirated, then added to non-irradiated C6 cells in order to investigate whether bystander effects are seen under the conditions of our image acquisition protocol. The irradiated medium was added to a number of other non-irradiated cell cultures. Cell counts were followed until 72 hrs after irradiation. Western blots were conducted with H2AX antibodies. This experiment was one of the first biomedical experiments conducted at BMIT, the new biomedical imaging and therapy beamline of the Canadian Light Source.Results: No significant differences in proliferation were seen between cells that were directly irradiated, exposed to irradiated medium or exposed to the non-irradiated 24-hr-medium from the irradiated cells. However, there was a tendency towards a higher number of double strand breaks in previously irradiated cells when they were exposed to non-irradiated medium that had been in contact with irradiated cells for 24 hrs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray Talbot-Lau interferometer for high-speed phase imaging and tomography using white synchrotron radiation

The Talbot interferometer using white synchrotron radiation has already been demonstrated for high-speed X-ray phase imaging and tomography as well as four-dimensional phase tomography for an observation of a dynamic specimen. In those previous experiments, the grating lines were oriented horizontally because the synchrotron radiation source size is large in the horizontal direction, and only the vertical spatial coherence satisfies the requirement for the operation of the Talbot interferometer given its distance from the source. For non-rigid samples, the horizontal axis of rotation causes unwanted motion of the sample due to gravity which results to artifact in the tomography reconstruction. For fluid samples, a vertical rotation axis is certainly necessary. While it is possible to orient the sample rotation axis perpendicular to the grating lines of the Talbot interferometer, solving the definite integral of the differential phase images to obtain the phase shift for x-ray phase tomography proves to be cumbersome when the sample extends outside the image and there is no null region for which the integration constant is known. In this work we aimed at increasing the spatial coherence of the x-rays along the horizontal so that the grating lines and the sample rotation axis could be oriented vertically. A Talbot-Lau interferometer was constructed by adding an absorption grating which acted as vertical line sources of horizontally spatially coherent white synchrotron radiation to the Talbot interferometer. An average of 20% moire fringe visibility was obtained. The set-up was demonstrated for highspeed phase tomography of a polymer sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The breaks and the hidden components in the power-law spectra of synchrotron radiation of the self-consistent current structures

Widespread use of a broken-power-law description of the spectra of synchrotron emission of various plasma objects requires an analysis of origin and a proper interpretation of spectral components. We show that, for a self-consistent magnetic configuration in a collisionless plasma, these components may be angle-dependent according to an anisotropic particle momentum distribution and may have no counterparts in a particle energy distribution. That has never been studied analytically and is in contrast to a usual model of synchrotron radiation, assuming an external magnetic field and a particle ensemble with isotropic momentum distribution. We demonstrate that for the wide intervals of observation angle the power-law spectra and, in particular, the positions and number of spectral breaks may be essentially different for the cases of the self-consistent and not-self-consistent magnetic fields in current structures responsible for the synchrotron radiation of the ensembles of relativistic particles with the multi-power-law energy distributions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗

Synchrotron radiography of Richtmyer–Meshkov instability driven by exploding wire arrays

We present a new technique for the investigation of shock-driven hydrodynamic phenomena in gases, liquids, and solids in arbitrary geometries. The technique consists of a pulsed power-driven resistive wire array explosion in combination with multi-MHz synchrotron radiography. Compared to commonly used techniques, it offers multiple advantages: (1) the shockwave geometry can be shaped to the requirements of the experiment, (2) the pressure (P > 300 MPa) generated by the exploding wires enables the use of liquid and solid hydrodynamic targets with well-characterized initial conditions (ICs), (3) the multi-MHz radiography enables data acquisition to occur within a single experiment, eliminating uncertainties regarding repeatability of the ICs and subsequent dynamics, and (4) the radiographic measurements enable estimation of compression ratios from the x-ray attenuation. In addition, the use of a synchrotron x-ray source allows the hydrodynamic samples to be volumetrically characterized at a high spatial resolution with synchrotron-based microtomography. This experimental technique is demonstrated by performing a planar Richtmyer–Meshkov instability (RMI) experiment on an aerogel–water interface characterized by Atwood number A0∼−0.8 and Mach number M∼1.5. The qualitative and quantitative features of the experiment are discussed, including the energy deposition into the exploding wires, shockwave generation, compression of the interface, startup phase of the instability, and asymptotic growth consistent with Richtmyer's impulsive theory. Additional effects unique to liquids and solids—such as cavitation bubbles caused by rarefaction flows or initial jetting due to small perturbations—are observed. It is also demonstrated that the technique is not shape dependent by driving a cylindrically convergent RMI experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GYRO-ORBIT SIZE, BRIGHTNESS TEMPERATURE LIMIT, AND IMPLAUSIBILITY OF COHERENT EMISSION BY BUNCHING IN SYNCHROTRON RADIO SOURCES

We show that an upper limit on the maximum brightness temperature for a self-absorbed incoherent synchrotron radio source is obtained from the size of its gyro orbits, which in turn must lie well within the confines of the total source extent. These temperature limits are obtained without recourse to inverse Compton effects or the condition of equipartition of energy between magnetic fields and relativistic particles. For radio variables, the intra-day variability implies brightness temperatures {approx}10{sup 19} K in the comoving rest frame of the source. This, if interpreted purely due to an incoherent synchrotron emission, would imply gyroradii >10{sup 28} cm, the size of the universe, while from the causality arguments the inferred maximum size of the source in such a case is {approx}< 10{sup 15} cm. Such high brightness temperatures are sometimes modeled in the literature as some coherent emission process where bunches of non-thermal particles are somehow formed that radiate in phase. We show that, unlike in the case of curvature radiation models proposed in pulsars, in the synchrotron radiation mechanism the oppositely charged particles would contribute together to the coherent phenomenon without the need to form separate bunches of the opposite charges. At the same time we show that bunches would disperse over dimensions larger than a wavelength in time shorter than the gyro orbital period ({approx}< 0.1 s). Therefore, a coherent emission by bunches cannot be a plausible explanation of the high brightness temperatures inferred in extragalactic radio sources showing variability over a few hours or longer.

79 ASTRONOMY AND ASTROPHYSICS↗

SPITZER OBSERVATIONS OF GX17+2: CONFIRMATION OF A PERIODIC SYNCHROTRON SOURCE

GX17+2 is a low-mass X-ray binary (LMXB) that is also a member of a small family of LMXBs known as 'Z-sources' that are believed to have persistent X-ray luminosities that are very close to the Eddington limit. GX17+2 is highly variable at both radio and X-ray frequencies, a feature common to Z-sources. What sets GX17+2 apart is its dramatic variability in the near-infrared, where it changes by {Delta}K {approx} 3 mag. Previous investigations have shown that these brightenings are periodic, recurring every 3.01 days. Given its high extinction (A{sub V} {>=} 9 mag), it has not been possible to ascertain the nature of these events with ground-based observations. We report mid-infrared Spitzer observations of GX17+2 which indicate a synchrotron spectrum for the infrared brightenings. In addition, GX17+2 is highly variable in the mid-infrared during these events. The combination of the large-scale outbursts, the presence of a synchrotron spectrum, and the dramatic variability in the mid-infrared suggest that the infrared brightening events are due to the periodic transit of a synchrotron jet across our line of sight. An analysis of both new, and archival, infrared observations has led us to revise the period for these events to 3.0367 days. We also present new Rossi X-Ray Timing Explorer (RXTE) data for GX17+2 obtained during two predicted infrared brightening events. Analysis of these new data, and data from the RXTE archive, indicates that there is no correlation between the X-ray behavior of this source and the observed infrared brightenings. We examine various scenarios that might produce periodic jet emission.

79 ASTRONOMY AND ASTROPHYSICS↗

AN ANGLE-DEPENDENT SYNCHROTRON SELF-COMPTON MODEL FOR RELATIVISTIC JET SOURCES

We report on the development of a numerical code to calculate the angle-dependent synchrotron + synchrotron self-Compton radiation from relativistic jet sources with partially ordered magnetic fields and anisotropic particle distributions. Using a multi-zone radiation transfer approach, we can simulate magnetic-field configurations ranging from perfectly ordered (unidirectional) to randomly oriented (tangled). We demonstrate that synchrotron self-Compton model fits to the spectral energy distributions (SEDs) of extragalactic jet sources may be possible with a wide range of magnetic-field values, depending on their orientation with respect to the jet axis and the observer. This is illustrated with the example of a spectral fit to the SED of Mrk 421 from multiwavelength observations in 2006, where acceptable fits are possible with magnetic-field values varying within a range of an order of magnitude for different degrees of B-field alignment and orientation.

79 ASTRONOMY AND ASTROPHYSICS↗

SYNCHROTRON EMISSION DRIVEN BY THE CHERENKOV-DRIFT INSTABILITY IN ACTIVE GALACTIC NUCLEI

In the present paper, we study the generation of synchrotron emission by means of the feedback of Cherenkov-drift waves on the particle distribution through the diffusion process. Despite the efficient synchrotron losses, it is demonstrated that the excited Cherenkov-drift instability leads to the quasi-linear diffusion (QLD), the effect of which is balanced by dissipation factors and, as a result, the pitch angles are prevented from damping, thus maintaining the corresponding synchrotron emission. We analyze the model for a wide range of physical parameters and determine that the mechanism of QLD guarantees the generation of electromagnetic radiation from soft X-rays up to soft {gamma}-rays, which is strongly correlated with Cherenkov-drift emission ranging from IR up to UV energy domains.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron self-inverse Compton radiation from reverse shock on GRB 120326A

We present multi-wavelength observations of a typical long duration GRB 120326A at z = 1.798, including rapid observations using a Submillimeter Array (SMA) and a comprehensive monitoring in the X-ray and optical. The SMA observation provided the fastest detection to date among seven submillimeter afterglows at 230 GHz. The prompt spectral analysis, using Swift and Suzaku, yielded a spectral peak energy of E{sub peak}{sup src}=107.8{sub −15.3}{sup +15.3} keV and an equivalent isotropic energy of E{sub iso} as 3.18{sub −0.32}{sup +0.40}×10{sup 52} erg. The temporal evolution and spectral properties in the optical were consistent with the standard forward shock synchrotron with jet collimation (6.°69 ± 0.°16). The forward shock modeling, using a two-dimensional relativistic hydrodynamic jet simulation, was also determined by the reasonable burst explosion and the synchrotron radiation parameters for the optical afterglow. The X-ray light curve showed no apparent jet break and the temporal decay index relation between the X-ray and optical (αo – α{sub X} = –1.45 ± 0.10) indicated different radiation processes in each of them. Introducing synchrotron self-inverse Compton radiation from reverse shock is a possible solution, and the detection and slow decay of the afterglow in submillimeter supports that this is a plausible idea. The observed temporal evolution and spectral properties, as well as forward shock modeling parameters, enabled us to determine reasonable functions to describe the afterglow properties. Because half of the events share similar properties in the X-ray and optical as the current event, GRB 120326A will be a benchmark with further rapid follow-ups, using submillimeter instruments such as an SMA and the Atacama Large Millimeter/submillimeter Array.

79 ASTRONOMY AND ASTROPHYSICS↗

Future trends in synchrotron science at NSLS-II

In this paper, we summarize briefly some of the future trends in synchrotron science as seen at the National Synchrotron Light Source II, a new, low emittance source recently commissioned at Brookhaven National Laboratory. We touch upon imaging techniques, the study of dynamics, the increasing use of multimodal approaches, the vital importance of data science, and finally, other enabling technologies. Each are presently undergoing a time of rapid change, driving the field of synchrotron science forward at an ever increasing pace. It is truly an exciting time and one in which Roger Cowley, to whom this journal issue is dedicated, would surely be both invigorated by, and at the heart of.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗