Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchronous generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Synchronized electric meter having an atomic clock

Smart electric meters configured to perform fast, time-synchronized electrical energy measurements at the consumer-level are disclosed herein. In some embodiments, a smart electric meter includes circuitry configured to measure an electrical value at a location of an end user in a power system. The smart electric meter can further include an atomic clock configured to output a timing signal, and a controller configured to receive (a) the measured electrical value from the circuitry and (b) the timing signal from the atomic clock. The controller can further (a) process the electrical value to generate meter data and (b) generate a time tag based on the timing signal. Then, the controller can associate the time tag with the meter data to generate time-tagged meter data.

Min, Liang↗

Gravitational waves from fully general relativistic oscillon preheating

As long-lived quasisolitons from the fragmentation of a scalar condensate, oscillons may dominate the preheating era after inflation. During this period, stochastic gravitational waves can also be generated. Here we quantify the gravitational-wave production in this period with simulations accounting for full general relativity to capture all possible nonperturbative effects. We compute the gravitational-wave spectra across a range of choices of the oscillon preheating models and compare our results to a conventional perturbative approach on a Friedmann-Lemaître-Robertson-Walker (FLRW) background. We clarify the gauge ambiguities in computing induced gravitational waves from scenarios where dense nonperturbative objects such as oscillons are being formed. In particular, we find that the synchronous gauge tends to contain large artificial enhancements in the gravitational-wave spectrum due to gauge modes if gravity plays an important role in the formation of the oscillons, while other gauge choices, such as the radiation gauge or a suitably chosen “1+log” gauge, can efficiently reduce the contributions of gauge modes. The full general-relativistic simulations indicate that gravitational-wave spectra obtained from the perturbative approach on the FLRW background are fairly accurate, except when oscillon formation induces strong gravitational effects, for which case there can be an order unity enhancement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Smart Inverters for Seamless Reconnection of Isolated Residential Microgrids to Utility Grid

This paper proposes an approach to achieve seamless reconnection of isolated residential microgrids to utility grid. Any abnormal condition on the grid side results in isolating the residential microgrid from utility grid, and giving the full responsibility of supplying household loads to local distributed generation (DG) units. However, after resolving the abnormal condition on the grid side, the residential microgrid needs to seamlessly reconnect to the main grid. To this end, a seamless transition algorithm is presented which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid before reconnection to the main grid. A modified control scheme is proposed for single-phase inverters which turns them into smart inverters enable to interact with seamless transition algorithm. The proposed approach synchronizes each phase voltage with its respective grid-side voltage in order to seamlessly reconnect the residential microgrid to the main grid. Case study results are carried out in PSCAD/EMTDC environment to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Caldera_Grid

Caldera Grid is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. Caldera Grid is a co-simulation framework implemented using Hierarchical Engine for Large scale Infrastructure Co-Simulation (HELICS). The framework facilitates the co-simulation of EV charging and Smart Charge Management (SCM) strategies in Caldera Infrastructure Charge Model (ICM) with distribution level grid models in OpenDSS. Vehicle energy needs and charge session requirements generated using Caldera Charge Decision Module (CDM) are fed in as input to Caldera Grid. The EV charging models in Caldera ICM simulates both the uncontrolled charging loads as well as loads modified by the SCM strategies to develop distributed load profiles for each grid node hosting an Electric Vehicle Supply Equipment (EVSE) – also known as chargers. These loads were simulated in OpenDSS alongside existing distribution feeder loads. Each of these models are co-simulated in a HELICS federate. The HELICS co-simulation framework facilitates communication and synchronization between the federates. By co-simulating EV loads and distribution feeder loads, Caldera Grid can assess the potential grid impacts of EV charging on distribution feeders under various grid conditions. A control strategy federate is implemented with an interface where control strategies based on feedback from EV charging status and grid conditions can be developed and implemented. The platform can also support multiple control strategies in a single co-simulation.

Sundarrajan, ManojKumar Cebol↗

Active magnetic regenerative cooling with smaller magnets

Magnetocaloric heat pumping near room temperature, a.k.a. magnetic cooling, relies on the active regenerator cycle to achieve functional temperature spans and realize economic and societal benefits promised by this emerging solid-state cooling technology. The cycle itself depends upon synchronizing oscillating flow of a heat transfer fluid through a solid porous active material matrix, or the refrigerant, with periods when the refrigerant is in the highest available (field-on) and in nearly zero (field-off) magnetic fields to accomplish heat transfer. With this in mind, in this work we analyze varying flow and magnetic field wave forms and the timing between when the fluid is pumped and when the magnetic field is turned on and off. We demonstrate that the volume and the cost of permanent magnet generating the field changes can be cut nearly in half with little to no effect on the device temperature span and cooling power normalized by the refrigerant mass.

36 MATERIALS SCIENCE↗

Optimizing the impacts of solid additives on the operational stability and processing reliability of organic solar cells

Previous reports have revealed that by leveraging solid additives, organic solar cells (OSCs) can surpass the device’s performance beyond the intrinsic limitations of host photoactive molecules, a remarkable advancement. However, the impacts of more complex interactions introduced by solid additives are not yet well understood. Herein, optimizing the fabrication process based on the traditional efficiency-guided approach fails to represent the ideal and most practical devices. In particular, achieving superior operational stability while minimizing the device performance scattering was found to require processing solvent evaporation to be synchronized with the volatility of the chosen solid additive. However, this may be challenging since most organic photoactive materials display excellent efficiencies only with selected solvents. Accordingly, this work also demonstrates the potential of dual and complementary solvents selection, consisting of low boiling point (primary) and high boiling point (secondary). This strategy allows for the suppression of any potential trade-offs in efficiency. Meanwhile, the operational stability and precision of device performance are substantially enhanced. Additionally, solid additives have demonstrated that the singlet exciton dissociation rate does not limit the free charge generation yield. Finally, these findings are expected to reformulate OSC device fabrication strategies towards more practical devices.

36 MATERIALS SCIENCE↗

An implicit barotropic mode solver for MPAS-ocean using a modern Fortran solver interface

Here, we demonstrate use of a modern Fortran solver interface to manage solver algorithms for an implicit barotropic mode solver in the Model for Predictions Across Scales-Ocean (MPAS-O). ForTrilinos, a Fortran interface to Trilinos that contains a large collection of solver capabilities written in C++, has been implemented in MPAS-O to provide access to a suite of linear solver options. By virtue of the simplified wrapper and interface generator (SWIG) automation tool that generates modern Fortran interfaces to C++ code, we were able to implement the Fortran solver interface in MPAS-O using a familiar Fortran coding style while minimizing performance degradation. The ForTrilinos solver interface is written within MPAS-O’s time stepping modules as a subroutine in conjunction with MPAS-O code. Applied to an idealized ocean and a high-resolution realistic ocean test case, parallel performance of ForTrilinos solvers is examined. It is found that parallel scalability of the ForTrilinos solvers is highly dependent on the number of global synchronization points per solver iteration in each iterative solver algorithm. ForTrilinos solvers perform best compared to the Fortran hand-crafted (FHC) solver when the amount of work per processor is large enough. However, parallel scalability is better with the FHC solver and so when the work per core is modest FHC outperforms ForTrilinos. The intercomparison between the ForTrilinos and FHC solvers reveals that this performance hit in the ForTrilinos solver mostly comes from the global synchronization process, while suggesting that the matrix-vector multiplication process in the FHC solver needs to be optimized for better performance.

97 MATHEMATICS AND COMPUTING↗

Effect of GPS Manipulation to Traditional and Next Generation Relay Protection

This project’s objective is to test the effect of GPS timing variations on relay protection algorithms to determine vulnerabilities and the associated hazards to the electric grid. This will focus on differential protection which utilizes peer to peer communication between substations to determine if the current is not equivalent. This requires the use of GPS to sync the two substations and can be vulnerable to GPS manipulation. However, the effects of GPS manipulation are not a commonly known risk. Therefore, this LDRD will address the risks of GPS manipulation for such a widely implemented technology. For differential protection a GPS resilient architecture was implemented and tested for differential protective relays through a direct serial fiber connection between the two relays. This allows for one relay to be the master and provide synchronization outside of timestamp for differential protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VerifyIO: Ensuring Correctness of Consistency Semantics in Parallel I/O

Abstract—High-performance computing (HPC) applications generate and consume substantial amounts of data, typically managed by parallel file systems. These applications access file systems either through the POSIX interface or by using highlevel I/O libraries. While the POSIX consistency model remains dominant in HPC, emerging file systems and popular I/O libraries increasingly adopt alternative consistency models that relax semantics in various ways, creating significant challenges for correctness and portability. This paper addresses these challenges by proposing a trace-driven I/O consistency verification workflow, implemented in our open-source tool, VerifyIO, which collects execution traces, detects data conflicts, and verifies proper synchronization against specified consistency models. Our extensive evaluation of 91 test case executions across three widely used I/O libraries with four I/O consistency models reveals critical consistency issues at both application and implementation levels.

Consistency Semantics↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Uncertainty Propagation from Experiment Measurements to Modeling Approaches: A Case for SMR Steam Entrainment Testing

To license new and advanced reactor designs, regulators must be convinced that their unique safety cases—relative to existing large scale reactors—have been adequately addressed by the designed reactor protection systems. In water cooled small modular reactors (SMRs), droplet entrainment in steam flow has significant implications on the progression of accident scenarios due to its compact design features, which requires representative test data applicable to SMR designs. Computer code, modeling and simulation (M&S) tools and models require adequate verification, assessment, and qualification. This includes M&S results validation against scaled empirical data within allowable uncertainty bands to gain regulatory approvals during the various stages of reactor system design, demonstration, and commercialization. However, measurement uncertainty within the empirical datasets and test data applicability ranges requires careful consideration of M&S inputs (i.e., boundary conditions, and initial conditions), and verification and validation efforts. This study focuses on uncertainty quantification in designing scaled test facilities for SMR applications with appropriate measurements and a standard data-reduction method to estimate thermal hydraulics characteristics parameters that incorporate physics phenomena of interest. In addition, this study supports the evaluation model development and assessment process using M&S that interfaces with advanced computing tools and digital twin capabilities. This will allow synchronization between experiment and modeling approaches for droplet entrainment testing and analysis, improving diagnostics, prognostics, and decision-making to accelerate regulatory approval.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Protein Motifs for Proton Transfers That Build the Transmembrane Proton Gradient

Biological membranes are barriers to polar molecules, so membrane embedded proteins control the transfers between cellular compartments. Protein controlled transport moves substrates and activates cellular signaling cascades. In addition, the electrochemical gradient across mitochondrial, bacterial and chloroplast membranes, is a key source of stored cellular energy. This is generated by electron, proton and ion transfers through proteins. The gradient is used to fuel ATP synthesis and to drive active transport. Here the mechanisms by which protons move into the buried active sites of Photosystem II (PSII), bacterial RCs (bRCs) and through the proton pumps, Bacteriorhodopsin (bR), Complex I and Cytochrome c oxidase (CcO), are reviewed. These proteins all use water filled proton transfer paths. The proton pumps, that move protons uphill from low to high concentration compartments, also utilize Proton Loading Sites (PLS), that transiently load and unload protons and gates, which block backflow of protons. PLS and gates should be synchronized so PLS proton affinity is high when the gate opens to the side with few protons and low when the path is open to the high concentration side. Proton transfer paths in the proteins we describe have different design features. Linear paths are seen with a unique entry and exit and a relatively straight path between them. Alternatively, paths can be complex with a tangle of possible routes. Likewise, PLS can be a single residue that changes protonation state or a cluster of residues with multiple charge and tautomer states.

cytochrome c oxidase↗

Path-synchronous performance monitoring of interconnection networks based on source code attribution

Examples disclosed herein relate to path-synchronous performance monitoring of an interconnection network based on source code attribution. A processing node in the interconnection network has a profiler module to select a network transaction to be monitored, determine a source code attribution associated with the network transaction to be monitored, and issue a network command to execute the network transaction to be monitored. A logger module creates, in a buffer, a node temporal log associated with the network transaction and the network command. A drainer module periodically captures the node temporal log. The processing node has a network interface controller to receive the network command and mark a packet generated for the network command to be temporally tracked and attributed back to the source code attribution at each hop of the interconnection network traversed by the marked packet.

Chabbi, Milind M.↗

Self-consistent integrated modeling of combined hybrid discharge-laser produced plasma devices for extreme ultraviolet metrology

Discharge- and laser-produced plasma (DLPP) devices are being used as light sources for extreme ultraviolet (EUV) generation. A key challenge for both, DPP and LPP, is achieving sufficient brightness to support the throughput requirements of nanometrology tools. To simulate the environment of a hybrid DLPP device and optimize the EUV output, we have developed an integrated HEIGHTS-DLPP computer simulation package. The package integrates simulation of two evolving plasmas (DPP and LPP) and includes modeling of a set of integrated self-consistent processes: external power source and plasma energy balance, plasma resistive magnetohydrodynamics, plasma heat conduction, detailed radiation transport (RT), and laser absorption and refraction. We simulated and optimized DLPP devices using Xe gas as a target material. We synchronized the external circuit parameters, chamber gas parameters, and laser beam temporal and spatial profiles to achieve maximum EUV output. The full 3D Monte Carlo scheme was integrated for detailed RT and EUV output calculations in Xe using more than 3600 spectral groups. The modeling results are in good agreement with Julich Forschungszentrum experimental data. Theoretical models, developed and integrated into the HEIGHTS package, showed wide capabilities and flexibility. In conclusion, the models and package can be used for optimization of the experimental parameters and settings, investigation of DLPP devices with complex design, analyzing the impact of integrated spatial effects and working timeline arrangement on the final EUV output, and EUV source size, shape, and angular distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cost Estimation of a Permanent Magnet Synchronous Machine for Use in Adjustable Speed-Pumped Storage Hydropower

Electric machine design has become an easier process with the availability of computers in recent decades. However, the interest in electric machine design among students has declined. University-level design courses must compete with courses perceived as more desirable by the potential job market. Hence, the power system engineers with this expertise are very few and are nearing retirement. Contrarily, renewable energy has been picking up in the past few decades. The indeterminacy and variation of renewable energy sources require a balancing mechanism to maintain the constant voltage and frequency of the grid. Adjustable-Speed Pumped-Storage Hydropower plants are considered the contender for future energy storage, providing large capacity and fast-acting response. Large-scale hydropower applications depend on the natural characteristics of each project site, making less expensive, off-the-shelf generators unfeasible. This work gives a shortcut to estimate the cost of constructing a permanent magnet generator for low-volume manufacturing.

13 HYDRO ENERGY↗

Effect of GPS Manipulation to Traditional and Next Generation Relay Protection (Final Report)

This project’s objective is to test the effect of GPS timing variations on relay protection algorithms to determine vulnerabilities and the associated hazards to the electric grid. This will focus on time domain protection which utilizes traveling waves measured on the transmission lines to detect the fault within a tower span. This requires the use of GPS to sync the two substations and can be vulnerable to GPS manipulation. However, the effects of GPS manipulation are not a commonly known risk. Therefore, this LDRD will address the risks of GPS manipulation for on a new protective relay technology that has the potential to change protective relaying. For time domain protection a GPS resilient architecture was implemented and tested for time domain protective relays through a direct serial fiber connection between the two relays. This allows for one relay to be the master and provide synchronization outside of timestamp for traveling wave protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On Control Schemes for Grid-Forming Inverters

Grid-forming inverters can collaboratively regulate the voltage and frequency of a microgrid. These inverters are expected to be seen more in the future microgrid, undertaking the roles of the conventional power generators. Like conventional power generators, they must balance supply and demand, contribute to power-sharing between inverters and other power generators, and restore the voltage and frequency after any power changes. These technical challenges are typically achieved through different primary and secondary controllers. This article reviews some state-of-the-art primary and secondary control schemes for the emerging technology of grid-forming inverters. First, the typical control schemes for grid-following inverters are briefly presented for the continuity of the discussion on the roles of the grid-forming inverters in future power-grid, followed by two basic control schemes for the grid-forming inverters. Then, two decentralized power-sharing techniques, i.e., droop, and virtual inertia, are analyzed. The technical challenges for inverter synchronization and some control methods are discussed afterward. Finally, several secondary control methods for the voltage and frequency restoration in grid-forming inverters are reviewed.

Sadeque, Fahmid↗

A Performance Model of In-Situ Techniques

The computational capacity of High-Performance Computing (HPC) systems increases continuously with the rapid development of central processing units (CPUs) and graphic processing units (GPUs), while the in-/output (IO) subsystem develops relatively slowly and storage capacity is also limited. Data-intensive applications, which are designed to leverage the high computational capacity of HPC resources, typically generate a considerable amount of data for post-processing visualizations and data analytics. The limited IO speed and storage space could lead to constraints in the actual performance of these applications and, therefore, scientific discovery. In-situ techniques, where data is visualized/analysed while still in memory rather than through disk, can contribute to alleviating these problems as they can reduce or even fully avoid data writing/reading through the IO subsystem to/from storage. However, the overall efficiency of insitu techniques crucially depends on the characteristics of both the in-situ tasks and the applications, and the resource distribution among them. Therefore, choosing the right in-situ approach (synchronous, asynchronous, or hybrid) and resource allocation is essential to minimize overhead and maximize the benefits of concurrent execution. In this paper, we present a performance model of in-situ techniques to find the most beneficial in-situ approach and the preferred resource configuration. We verify the high accuracy of our approach with over 6800 measurements and provide use cases with different applications.

Ju, Yi [Max Planck Computing and Data Facility, Ga↗