Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchronous generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Ram acceleration from a two phase detonative system

A concept for ram acceleration is presented here, which uses a combination of a gas core and a layer of solid explosive or propellant to generate high thrust densities. The concept can be either self-synchronized or externally synchronized, and may be reusable. It has the potential to achieve very high acceleration rates, higher exit velocities and to lower the tube length requirements. Preliminary numerical simulations are presented and discussed, which show the characteristics of the flow fields. Stable conditions can be achieved for low mass loadings of solid explosive, and relatively slow combustion. Accurate knowledge of the thermo-chemical properties and the equations of state of the gas and solid components is essential for further tuning of the concept.

Cambier, Jean-Luc↗

High-frequency ac power distribution in Space Station

A utility-type 20-kHz ac power distribution system for the Space Station, employing resonant power-conversion techniques, is presented. The system converts raw dc voltage from photovoltaic cells or three-phase LF ac voltage from a solar dynamic generator into a regulated 20-kHz ac voltage for distribution among various loads. The results of EASY5 computer simulations of the local and global performance show that the system has fast response and good transient behavior. The ac bus voltage is effectively regulated using the phase-control scheme, which is demonstrated with both line and load variations. The feasibility of paralleling the driver-module outputs is illustrated with the driver modules synchronized and sharing a common feedback loop. An HF sinusoidal ac voltage is generated in the three-phase ac input case, when the driver modules are phased 120 deg away from one another and their outputs are connected in series.

Tsai, Fu-Sheng↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗

Power processing and control requirements of dispersed solar thermal electric generation systems

Power Processing and Control requirements of Dispersed Receiver Solar Thermal Electric Generation Systems are presented. Kinematic Stirling Engines, Brayton Engines and Rankine Engines are considered as prime movers. Various types of generators are considered for ac and dc link generations. It is found that ac-ac Power Conversion is not suitable for implementation at this time. It is also found that ac-dc-ac Power Conversion with a large central inverter is more efficient than ac-dc-ac Power Conversion using small dispersed inverters. Ac-link solar thermal electric plants face potential stability and synchronization problems. Research and development efforts are needed in improving component performance characteristics and generation efficiency to make Solar Thermal Electric Generation economically attractive.

Das, R. L.↗

Pulsar Based Timing for Grid Synchronization

Existing synchronization systems in the power grid, such as the global positioning system, are susceptible to temporary or permanent failures due to various unpredictable and uncontrollable factors such as cyber-attack and electromagnetic interferences, thus affecting the accuracy and reliability of generated timing signal. In this article, a pulsar astronomy-based timing system is proposed to provide an alternative synchronization signal. Further, this clock will offer significant security improvements to power grid applications, such as a wide-area monitoring system, which depends on a precise timing signal. The hardware and software frameworks are described in detail. First, a high-speed sampling hardware platform is designed to collect signals from radio telescopes. Then a periodic pulse extraction method with three steps is proposed to process the pulsar signal, including polyphase filterbanks, incoherent de-dispersion, and sliding window folding. Lastly, three experiments are conducted to verify the effectiveness of the frameworks. The generated pulsar timing pulse is presented, and the factors affecting its accuracy are also discussed. The analysis results demonstrate that the pulsar signals can provide high-accurate timing pulses for grid synchronization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time Interval Errors of a Flicker-noise Generator

Time interval error (TIE) is the error of a clock at time t after it is synchronized and syntonized at time zero. Previous simulations of Flicker FM noise yielded a mean-square TIE proportional to sq t. It is shown that the order of growth is actually sq t log t. The earlier sq t result is explained and a modified version of the Barnes-Jarvis simulation algorithm is given.

Greenhall, C. A.↗

Event Fanout/Receiver (evfr) v1.0

The event fanout-receiver is an event-based timing system implementation capable of synchronizing (with respect to clock, events and triggers) to an upstream event generator. This can be used in 2 modes: fanout or receiver. the first one receives 1 upstream timing streams and fanouts it to 36. The second one receives and decodes the stream. This has been in use by ALS for many years and this is a similar implementation, but providing a more flexible configuration

Russo, Lucas↗

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE↗

The generation of pollution-free electrical power from solar energy.

Projections of the U.S. electrical power demands over the next 30 years indicate that the U.S. could be in grave danger from power shortages, undesirable effluence, and thermal pollution. An appraisal of nonconventional methods of producing electrical power is conducted, giving particular attention to the conversion of solar energy into commercial quantities of electrical power by solar cells. It is found that 1% of the land area of the 48 states could provide the total electrical power requirements of the U.S. in the year 1990. The ultimate method of generating vast quantities of electrical power would be from a series of synchronous satellites which beam microwave power back to earth to be used wherever needed. Present high manufacturing costs of solar cells could be substantially reduced by using massive automated techniques employing abundant low cost materials.

Cherry, W. R.↗

SIT-5 system development.

A 5-cm structurally integrated ion thruster (SIT-5) has been developed for attitude control and stationkeeping of synchronous satellites. With two-dimension thrust-vectoring grids, a first generation unit has demonstrated a thrust of 0.56 mlb at a beam voltage of 1200 V, total mass efficiency of 64%, and electrical efficiency of 46.8%. Structural integrity is demonstrated with a dielectric-coated grid for shock (30 G), sinusoidal (9 G), and random (19.9 G rms) accelerations. System envelope is 31.8 cm long by 13.9 cm flange bolt circle, with a mass of 8.5 kg, including 6.2 kg mercury propellant. Characteristics of a second-generation unit indicate significant performance gains.

Hyman, J., Jr.↗

Simultaneous ground-satellite observations of Pi 2 magnetic pulsations and their high frequency enhancement

Pi 2 magnetic pulsations are a frequent occurrence at the earth's surface and have been shown to be clearly correlated with substorm expansion onset. These pulsations are also observed in space at synchronous orbit at the same time as they are seen on the ground at the satellite conjugate point. This brief report describes three days in 1969 on which Pi 2 magnetic pulsations were simultaneously observed at the synchronous satellite ATS 1 and at Tungsten, N.W.T., Canada, near the foot of the ATS 1 magnetic field line. These Pi 2 bursts all exhibit the characteristic waveform and frequency, as well as an 0.3 Hz enhancement, at both locations. This high frequency enhancement appears to be an integral part of Pi 2 bursts both on the surface and at synchronous orbit and should be considered in the development of models of generation mechanisms.

Arthur, C. W.↗

Effects of Gravity on Insect Circadian Rhythmicity

Circadian rhythms - endogenous daily rhythmic fluctuations in virtually all characteristics of life - are generated and coordinated by the circadian timing system (CTS). The CTS is synchronized to the external 24-hour day by time cues such as the light/dark cycle. In an environment without time cues, the length of an animal's day is determined by the period of its internal pacemaker (tau) and the animal is said to be free-running. All life on earth evolved under the solar day; the CTS exists as an adaptation that allows organisms to anticipate and to prepare for rhythmic environmental fluctuations. All life on earth also evolved under the force of earth's gravitational environment. While it is therefore not surprising that changes in the lighting environment affect the CTS, it is surprising that changes in the gravitational environment would do so. However, recent data from one of our laboratories using the brn-3.1 knockout mouse revealed that this model, which lacks the sensory receptor hair cells within the neurovestibular system, does not respond to exposure to a hyperdynamic environment in the same fashion as normal mice. The brn-3.1 mice did not show the expected suppression of circadian rhythmicity shown by control mice exposed to 2G. Exposure to altered ambient force environments affects the amplitude, mean and timing of circadian rhythms in species from unicellular organisms to man. In addition, there is a circadian influence on the homeostatic response to acute 2G acceleration and pulses of 2G can act as a time cue, synchronizing the CTS. This is of significance because maintenance of internal and external temporal coordination is critical for normal physiological and psychological function. Typically, during adaptation to an increased gravitational environment (+G), an initial acute reaction is followed by adaptation and, eventually, a new steady state (14-16), which can take weeks to months to establish. Until the development of space stations, exposure to microgravity was, of necessity, relatively short in duration. In early spaceflight experiments an organism's internal rhythms often expressed periods that were different from each other, even in the presence of a 24.0 hour light-dark cycle, suggesting that the organism was experiencing internal desynchronization (17, 18). In (micro)G, the body temperature rhythm was delayed with respect to other body rhythms and to the light-dark cycle in rhesus macaques (19) and man (20, 21). In the absence of a light-dark cycle, the circadian rhythm of spore formation persisted in Neurospora crassa, however, both the variability and average period of the rhythm increased (22). The beetle Trigonoscelis gigas, exhibited changes in period during and following 11-13 days in (micro)G (23, 24). Resynchronization of the urinary calcium rhythm following a 1800 phase shift of the LID cycle was retarded in rats exposed to (micro)G compared to 1G controls (25). With the development of the Russian Mir Space Station, long-term controlled microgravity exposure became possible. We recorded activity rhythms from black-bodied Tenebrionid beetles, Trigonoscelis gigas, in (micro)G (spaceflight). Each insect was housed individually within an activity monitor (26) and data (activity counts) were collected and stored in five-minute bins. Thirty-two individual activity monitors were housed within each of 2 experimental kits. The beetles within each kit were divided into two groups and the lighting was controlled separately for each group.

Hoban-Higgins, Tana M.↗

A 400-kWe high-efficiency steam turbine for industrial cogeneration

An advanced state-of-the-art steam turbine-generator developed to serve as the power conversion subsystem for the Department of Energy's Sandia National Laboratories' Solar Total-Energy Project (STEP) is described. The turbine-generator, which is designed to provide 400-kW of net electrical power, represents the largest turbine-generator built specifically for commercial solar-powered cogeneration. The controls for the turbine-generator incorporate a multiple, partial-arc entry to provide efficient off-design performance, as well as an extraction control scheme to permit extraction flow regulation while maintaining 110-spsig pressure. Normal turbine operation is achieved while synchronized to a local utility and in a stand-alone mode. In both cases, the turbine-generator features automatic load control as well as remote start-up and shutdown capability. Tests totaling 200 hours were conducted to confirm the integrity of the turbine's mechanical structure and control function. Performance tests resulted in a measured inlet throttle flow of 8,450 pounds per hour, which was near design conditions.

Leibowitz, H. M.↗

Coupled Electro-Thermal Analysis of Permanent Magnet Synchronous Motor for Electric Vehicles

Permanent magnet synchronous motors (PMSM) are extensively used in electric vehicles. However, high internal heat generation and inefficient heat dissipation often limit the operational reliability, and longevity of the PMSM. Therefore, proper quantification of heat generation in electric motor and advanced embedded motor cooling techniques remain topics of immense interest. In order to accurately predict electro-magnetic performance, i.e., efficiency, component-wise heat losses and the corresponding temperature distribution of a jacket cooled machine, this paper presents a two-way iteratively coupled electro-thermal modeling framework. Finite element based software Motor-CAD has been utilized for electro-magnetic performance calculation of BMW i3 PMSM. Finite volume based computational fluid dynamics/heat transfer (CFD/HT) software ANSYS® FLUENT® has been employed to simulate the temperature distribution of the PMSM, using the electro-magnetic losses as heat input. Computed heat losses, stator, winding, rotor, and magnet temperatures are utilized as coupling parameters between the electro-magnetic and thermal models. A conventional one-way coupling algorithm has also been developed and compared to the newly proposed two-way coupling algorithm. Numerical results confirm that at high current density, one-way coupling algorithm significantly over-predicts the motor temperature compared to the two-way algorithm. A comprehensive analysis has been carried out to characterize the influences of current density, speed, and forced convection heat transfer coefficient on the heat losses, overall efficiency, and maximum temperature of the PMSM. Lastly, an efficiency map has been interpreted from the coupled electro-magnetic simulation.

42 ENGINEERING↗

Television multiplexing system

A television multiplexing system which includes a circuit that inserts a digital codes sync signal and a digital code into a video signal for identifying the channel is described. The digital sync signal and the digital coded signals are generated by a single crystal controlled clock so that they are always in synchronism with each other. In demultiplexing the signals are utilized for shifting the digital coded signals into a shift register. The shift register, in turn, activates a decoder according to the code stored in the shift register for selecting the proper recording disk or receiver for storing the video signal.

Simpkins, L. G.↗

Broadband Noise Predictions for an Airfoil in a Turbulent Stream

Loading noise is predicted from unsteady surface pressure measurements on a NACA 0015 airfoil immersed in grid-generated turbulence. The time-dependent pressure is obtained from an array of synchronized transducers on the airfoil surface. Far field noise is predicted by using the time-dependent surface pressure as input to Formulation 1A of Farassat, a solution of the Ffowcs Williams - Hawkings equation. Acoustic predictions are performed with and without the effects of airfoil surface curvature. Scaling rules are developed to compare the present far field predictions with acoustic measurements that are available in the literature.

Casper, J.↗

Optimal space communications techniques

The design, development, and analysis are reported of a digital phase-locked loop (DPLL) for FM demodulation and threshold extension. One of the features of the developed DPLL is its synchronous, real time operation. The sampling frequency is constant and all the required arithmetic and logic operations are performed within one sampling period, generating an output sequence which is converted to analog form and filtered. An equation relating the sampling frequency to the carrier frequency must be satisfied to guarantee proper DPLL operation. The synchronous operation enables a time-shared operation of one DPLL to demodulate several FM signals simultaneously. In order to obtain information about the DPLL performance at low input signal-to-noise ratios, a model of an input noise spike was introduced, and the DPLL equation was solved using a digital computer. The spike model was successful in finding a second order DPLL which yielded a five db threshold extension beyond that of a first order DPLL.

Schilling, D. L.↗