Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “suspensions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Changes in skeletal muscle properties following hindlimb suspension

Changes in AChE regulation, the functions of the sarcoplasmic reticulum (SR), and muscle fiber-type population in the extensor digitorium longus (EDL) and soleus of male rats suspended in a nonweight-bearing position are studied. Muscle weight, AChE activity, protein content, SR calcium loading rates, and muscle types in the suspended and control rats are evaluated and compared. It is observed that following 1-4 weeks of suspension the EDL is unaffected; however, the soleus muscle weight, and protein content decrease and the AChE activity increases. The SR calcium loading rates of EDL decrease 10 percent and the soleus increase 50 percent in the suspended rats. The data reveal that the population of muscle type 1 (slow fibers) decreases and type 2 (fast fibers) increases for the soleus, and the distribution is unchanged for the EDL of the suspended rats. It is detected that a nonweight-bearing position affects the soleus (a fast-twitch muscle), but not the EDL (a slow-twitch muscle).

Patterson, G. T.↗

Muscle protein and glycogen responses to recovery from hypogravity and unloading by tail-cast suspension

Previous studies in this laboratory using the tail-bast hindlimb suspension model have shown that there are specific changes in protein and carbohydrate metabolism in the soleus muscle due to unloading. For example, 6 days of unloading caused a 27 percent decrease in mass and a 60 percent increse in glycogen content in the soleus muscle, while the extensor digitorum longus muscle was unaffected. Also, fresh tissue tyrosine and its in vitro release from the muscle are increased in the unloaded soleus, indicating that this condition causes a more negative protein balance. With these results in mind, studies to investigate the effect of hypogravity on protein and carbohydrate metabolism in a number of rat hindlimb muscles were carried out.

Henriksen, E. J.↗

The use of suspension models and comparison with true weightlessness

A resume is presented of various papers concerning the effect of weightlessness on particular physiological and biochemical phenomena in animal model systems. Findings from weightlessness experiments on earth using suspension models are compared with results of experiments in orbit. The biological phenomena considered include muscle atrophy, changes in the endocrine system, reduction in bone formation, and changes in the cardiovascular system.

Musacchia, X. J.↗

Models of disuse - A comparison of hindlimb suspension and immobilization

The effects of 1 and 2 weeks of hindlimb suspension (HS) on the contractile properties of fast- and slow-twitch skeletal muscles of male Sprague Dawley rats are studied and compared with hindlimb immobilization (HI) data. The optimal length and contractile properties of the slow-twitch soleus, fast-twitch extensor digitorum longus, and the vastus lateralis are measured. It is observed that HS and HI affect slow-twitch muscles; isometric twitch duration in the slow-twitch soleus is decreased. Soleus muscle mass and peak tetanic tension declines with disuse. A major difference in the influence of HS and HI on the maximal speed of soleus muscle shortening, V(max) is detected; HS produced a twofold increase in V(max) compared to control data and HI had no significant effect on V(max). The relation between V(max) and myosin concentration is analyzed. The data reveal that HS modifies slow-twitch muscle yielding hybrid fibers with elevated shortening velocities and this change may be dependent on the elimination of load-bearing contractions.

Fitts, R. H.↗

Potential benefits of magnetic suspension and balance systems

The potential of Magnetic Suspension and Balance Systems (MSBS) to improve conventional wind tunnel testing techniques is discussed. Topics include: elimination of model geometry distortion and support interference to improve the measurement accuracy of aerodynamic coefficients; removal of testing restrictions due to supports; improved dynamic stability data; and stores separation testing. Substantial increases in wind tunnel productivity are anticipated due to the coalescence of these improvements. Specific improvements in testing methods for missiles, helicopters, fighter aircraft, twin fuselage transports and bombers, state separation, water tunnels, and automobiles are also forecast. In a more speculative vein, new wind tunnel test techniques are envisioned as a result of applying MSBS, including free-flight computer trajectories in the test section, pilot-in-the-loop and designer-in-the-loop testing, shipboard missile launch simulation, and optimization of hybrid hypersonic configurations. Also addressed are potential applications of MSBS to such diverse technologies as medical research and practice, industrial robotics, space weaponry, and ore processing in space.

Lawing, Pierce L.↗

High angle of attack position sensing for the Southampton University magnetic suspension and balance system

An all digital five channel position detection system is to be installed in the Southampton University Magnetic Suspension and Balance System (SUMSBS). The system is intended to monitor a much larger range of model pitch attitudes than has been possible hitherto, up to a maximum of a 90 degree angle of attack. It is based on the use of self-scanning photodiode arrays and illuminating laser light beams, together with purpose built processing electronics. The principles behind the design of the system are discussed, together with the results of testing one channel of the system which was used to control the axial position of a magnetically suspended model in SUMSBS. The removal of optically coupled heave position information from the axial position sensing channel is described.

Parker, David H.↗

Size and metabolic properties of single muscle fibers in rat soleus after hindlimb suspension

The effect of 28-day-long hind-limb suspension (HS) combined with 10 daily forceful lengthening contractions of the limb on the morphological and metabolic properties of individual fibers of the soleus was studied in rats, using quantitative histochemical techniques. Compared with nonsuspended controls (CON), soleus wet weights of HS rats were decreased by 49 percent; the fibers staining lightly for myosin ATPase ('light-ATPase' fibers) atrophied more than the 'dark-ATPase' fibers. Single-fiber alpha-glycerophosphate dehydrogenase (GPD) and succinate dehydrogenase (SDH) activities were higher in HS than in CON rats. Daily forceful lengthening contractions did not prevent the HS-induced changes. The results support the view that the soleus fibers can change from a slow-twitch oxidative to a fast-twitch oxidative-glycolytic profile, but rarely to a fast-twitch glycolytic one, and that the SDH and GPD activities per volume of tissue can be increased even when there are severe losses of contractile proteins.

Hauschka, Edward O.↗

Size and metabolic properties of fibers in rat fast-twitch muscles after hindlimb suspension

The effect of hind-limb suspension (HS) on single fibers of the medial gastrocnemius (MG) and the tibialis anterior (TA) muscles were studied in rats. Fiber area and the activities of succinate dehydrogenase (SDH) and alpha-glycerophosphate dehydrogenase (GPD) were determined in tissue sections using an image analysis system. After 28 days of HS, the MG atrophied 28 percent, whereas the TA weight was maintained. Both dark- and light-ATPase fibers in the deep region of the MG had decreased cross-sectional areas following HS, with the atrophic response being twice as great in the light-ATPase fibers than in the dark-ATPase fibers. Following HS, mean SDH activities of both fiber types were significantly lower in the MG and TA than in the CON; by contrast, mean GPD activities were either maintained at the CON level or were higher in both MG and TA muscles. The data suggest an independence of the mechanisms determining the muscle fiber size and the metabolic adaptations associated with HS.

Roy, Roland R.↗

Suspension cell culture in microgravity and development of a space bioreactor

NASA has methodically developed unique suspension type cell and recovery apparatus culture systems for bioprocess technology experiments and production of biological products in microgravity. The first space bioreactor has been designed for microprocessor control, no gaseous headspace, circulation and resupply of culture medium, and slow mixing in very low shear regimes. Various ground based bioreactors are being used to test reactor vessel design, on-line sensors, effects of shear, nutrient supply, and waste removal from continuous culture of human cells attached to microcarriers. The small (500 ml) bioreactor is being constructed for flight experiments in the Shuttle middeck to verify systems operation under microgravity conditions and to measure the efficiencies of mass transport, gas transfer, oxygen consumption, and control of low shear stress on cells.

Morrison, Dennis R.↗

The effect of sting interference at low speeds on the drag coefficient of an ellipsoidal body using a magnetic suspension and balance system

A Boltz body of revolution (fineness ratio 7.5:1) was tested in the Southampton University Magnetic Suspension and Balance System. The effects of sting interference on the drag coefficient of the model at zero angle of attack were noted as well as the effects on drag coefficient values at boundary layer trips. The drag coefficient values were compared with other sources and seemed to show agreement. The pressure distribution over the rear of the model with no sting interference was investigated including the use of boundary layer trips.

Newcomb, A. W.↗

Drag measurements on a laminar flow body of revolution in Langley's 13 inch magnetic suspension and balance system

Low-speed wind tunnel drag force measurements were taken on a laminar flow body of revolution free of support interference. This body was tested at zero incidence in the NASA Langley 13 inch Magnetic Suspension and Balance System (MSBS). The primary objective of these tests was to substantiate the drag force measuring capabilities of the 13 inch MSBS. A secondary objective was to obtain support interference free drag measurements on an axisymmetric body of interest. Both objectives were met. The drag force calibrations and wind-on repeatability data provide a means of assessing the drag force measuring capabilities of the 13 inch MSBS. The measured drag coefficients for this body are of interest to researchers actively involved in designing minimum drag fuselage shapes. Additional investigations included: the effects of fixing transition; the effects of fins installed in the tail; surface flow visualizations using both liquid crystals and oil flow; and base pressure measurements using a one-channel telemetry system. Two drag prediction codes were used to assess their usefulness in estimating overall body drag. These theoretical results did not compare well with the measured values because of the following: incorrect or non-existent modeling of a laminar separation bubble on the body and incorrect of non-existent estimates of base pressure drag.

Dress, David A.↗

Enhancement of viral pathogenesis in mice maintained in an antiorthostatic suspension model - Coordination with effects on interferon production

Both rodents and men returning from spaceflight have exhibited alterations in immune responses and, in particular, interferon production. This work utilizes a model for antiorthostatic (20-deg head-down tilt), hypokinetic, hypodynamic suspension of mice that simulates some aspects of weightlessness. Female Swiss/Webster mice that are normally resistant to infection with the D variant of encephalomyocarditis virus showed a marked increase in susceptibility to infection when suspended. This correlated with a drop in interferom production. Control, orthostatically suspended mice (no tilt) showed no increase in susceptibility to the virus.

Gould, C. L.↗

Magnetic suspension and balance system (MSBS) advanced study.I - System design

A magnetic suspension and balance system is designed to support models of aircraft or other objects in wind tunnels by means of magnetic forces. Major design improvements have been achieved, resulting in reductions of the system size, weight, and cost. These improvements are due to: (1) the use of holmium in the model core to increase its magnetic moment, (2) the use of a powerful new permanent magnet material in the model wings, (3) a new arrangement for the roll coils, and (4) the use of a nonmetallic structure to eliminate eddy current losses. The conceptual design of the holmium core superconductive solenoid and of the new permanent magnet wing assembly is described in detail. The discussion includes comparisons of the pole strengths for different model core magnets, the design of a superconducting solenoid and cryostat, and the analysis of model wing magnetic requirements.

Boom, Roger W.↗

Strain-gage balance calibration of a magnetic suspension and balance system

A load calibration of the NASA 13-in magnetic suspension and balance system (MSBS) is described. The calibration procedure was originally intended to establish the empirical relationship between the coil currents and the external loads (forces and moments) applied to a magnetically suspended calibrator. However, it was discovered that the performance of a strain-gage balance is not affected when subjected to the magnetic environment of the MSBS. The use of strain-gage balances greatly reduces the effort required to perform a current-vs.-load calibration as external loads can be directly inferred from the balance outputs while a calibrator is suspended in MSBS. It is conceivable that in the future such a calibration could become unnecessary, since an even more important application for the use of a strain-gage balance in MSBS environment is the acquisition of precision aerodynamic force and moment data by telemetering the balance outputs from a suspended model/core/balance during wind tunnel tests.

Roberts, Paul W.↗

Digital control of wind tunnel magnetic suspension and balance systems

Digital controllers are being developed for wind tunnel magnetic suspension and balance systems, which in turn permit wind tunnel testing of aircraft models free from support interference. Hardware and software features of two existing digital control systems are reviewed. Some aspects of model position sensing and system calibration are also discussed.

Britcher, Colin P.↗

A review of Magnetic Suspension and Balance Systems

This paper traces the development of Magnetic Suspension and Balance Systems (MSBSs) for use in wind tunnels. The expression MSBS implies a system that can both suspend a model and also measure the forces and moments acting on the model. This avoids the need for any mechanical support of the model. An MSBS uses electromagnets located outside the test section walls to create magnetic fields inside the test section. Measurement of the electrical current flowing in each of the electromagnets can be used to determine the forces and moments acting on the suspended model. An MSBS is capable of supporting a model with an internal magnetized core subject to gravity, aerodynamic, and inertial loads. The model must have a core made of either a permanent magnet, magnetized soft iron, or a solenoid. The position of the suspended body is inherently unstable. A closed-loop control system which includes a position sensing system has to control the position of the body by controlling the applied magnetic fields. This paper includes a discussion of all the known MSBSs and the outlook for larger systems.

Boyden, Richmond P.↗

Drag measurements on a body of revolution in Langley's 13-inch Magnetic Suspension and Balance System

NASA Langley's 13-inch Magnetic Suspension and Balance System (MSBS) has been used to conduct low-speed wind tunnel drag force measurements on a laminar-flow body-of-revolution free of support system interference, in order to verify the drag force measurement capabilities of the MSBS. The drag force calibrations and wind-on repeatability data obtained have verified the design capabilities for this system. A drag-prediction code has been used to assess the MSBS's usefulness in body drag estimation.

Dress, David A.↗

Comparative morphometry of fibers and capillaries in soleus following weightlessness (SL-3) and suspension

This work is a continuation of efforts to assess responses of rat skeletal muscle to weightlessness (W) and earthside laboratory experiments with unloading of hind limbs. The soleus is a slow-twitch, load-bearing (antigravity) muscle. Both exposure to W and to the hypokinesia/hypodynamia of whole-body suspension (WBS) results in soleus atrophy. Cross-sectional areas of both slow- and fast-twitch fibers decrease during 7 days of W or 7 or 14 days of WBS. Density and area changes tended to reverse to control levels during 7 days of recovery (R) following WBS. Capillary density was increased with 7 days of W or 7 or 14 days of WBS. During 7 days of R the capillary density returned toward control levels. In summary, the reduction in fiber cross-sectional areas and the increase in fiber and capillary densities support the hypothesis that in both W and WBS there is a loss in soleus muscle cell mass and not in fiber numbers.

Musacchia, X. J.↗