Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroscopic methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A Miniaturized Laser Heterodyne Radiometer for a Global Ground-Based Column Carbon Monitoring Network

We present progress in the development of a passive, miniaturized Laser Heterodyne Radiometer (mini-LHR) that will measure key greenhouse gases (C02, CH4, CO) in the atmospheric column as well as their respective altitude profiles, and O2 for a measure of atmospheric pressure. Laser heterodyne radiometry is a spectroscopic method that borrows from radio receiver technology. In this technique, a weak incoming signal containing information of interest is mixed with a stronger signal (local oscillator) at a nearby frequency. In this case, the weak signal is sunlight that has undergone absorption by a trace gas of interest and the local oscillator is a distributive feedback (DFB) laser that is tuned to a wavelength near the absorption feature of the trace gas. Mixing the sunlight with the laser light, in a fast photoreceiver, results in a beat signal in the RF. The amplitude of the beat signal tracks the concentration of the trace gas in the atmospheric column. The mini-LHR operates in tandem with AERONET, a global network of more than 450 aerosol sensing instruments. This partnership simplifies the instrument design and provides an established global network into which the mini-LHR can rapidly expand. This network offers coverage in key arctic regions (not covered by OCO-2) where accelerated warming due to the release of CO2 and CH4 from thawing tundra and permafrost is a concern as well as an uninterrupted data record that will both bridge gaps in data sets and offer validation for key flight missions such as OCO-2, OCO-3, and ASCENDS. Currently, the only ground global network that routinely measures multiple greenhouse gases in the atmospheric column is TCCON (Total Column Carbon Observing Network) with 18 operational sites worldwide and two in the US. Cost and size of TCCON installations will limit the potential for expansion, We offer a low-cost $30Klunit) solution to supplement these measurements with the added benefit of an established aerosol optical depth measurement. Aerosols induce a radiative effect that is an important modulator of regional carbon cycles. Changes in the diffuse radiative flux fraction (DRF) due to aerosol loading have the potential to alter the terrestrial carbon exchange.

Wilson, Emily L.↗

Hydrogen-Bonding Surfaces for Ice Mitigation

Ice formation on aircraft, either on the ground or in-flight, is a major safety issue. While ground icing events occur predominantly during the winter months, in-flight icing can happen anytime during the year. The latter is more problematic since it could result in increased drag and loss of lift. Under a Phase I ARMD NARI Seedling Activity, coated aluminum surfaces possessing hydrogen-bonding groups were under investigation for mitigating ice formation. Hydroxyl and methyl terminated dimethylethoxysilanes were prepared via known chemistries and characterized by spectroscopic methods. These materials were subsequently used to coat aluminum surfaces. Surface compositions were based on pure hydroxyl and methyl terminated species as well as mixtures of the two. Coated surfaces were characterized by contact angle goniometry. Receding water contact angle data suggested several potential surfaces that may exhibit reduced ice adhesion. Qualitative icing experiments performed under representative environmental temperatures using supercooled distilled water delivered via spray coating were inconclusive. Molecular modeling studies suggested that chain mobility affected the interface between ice and the surface more than terminal group chemical composition. Chain mobility resulted from the creation of "pockets" of increased free volume for longer chains to occupy.

Smith, Joseph G., Jr.↗

Photosystem Trap Energies and Spectrally-Dependent Energy-Storage Efficiencies in the Chl d-Utilizing Cyanobacterium, Acaryochloris Marina

Acaryochloris marina is the only species known to utilize chlorophyll (Chl) d as a principal photopigment. The peak absorption wavelength of Chl d is redshifted approx. 40 nm in vivo relative to Chl a, enabling this cyanobacterium to perform oxygenic phototrophy in niche environments enhanced in far-red light. We present measurements of the in vivo energy-storage (E-S) efficiency of photosynthesis in A. marina, obtained using pulsed photoacoustics (PA) over a 90-nm range of excitation wavelengths in the red and far-red. Together with modeling results, these measurements provide the first direct observation of the trap energies of PSI and PSII, and also the photosystem-specific contributions to the total E-S efficiency. We find the maximum observed efficiency in A. marina (40+/-1% at 735 nm) is higher than in the Chl a cyanobacterium Synechococcus leopoliensis (35+/-1% at 690 nm). The efficiency at peak absorption wavelength is also higher in A. marina (36+/-1% at 710 nm vs. 31+/-1% at 670 nm). In both species, the trap efficiencies are approx. 40% (PSI) and approx. 30% (PSII). The PSI trap in A. marina is found to lie at 740+/-5 nm, in agreement with the value inferred from spectroscopic methods. The best fit of the model to the PA data identifies the PSII trap at 723+/-3 nm, supporting the view that the primary electron-donor is Chl d, probably at the accessory (ChlD1) site. A decrease in efficiency beyond the trap wavelength, consistent with uphill energy transfer, is clearly observed and fit by the model. These results demonstrate that the E-S efficiency in A. marina is not thermodynamically limited, suggesting that oxygenic photosynthesis is viable in even redder light environments.

Mielke, Steven P.↗

Measurement of Cohesion in Asteroid Regolith Materials

A study has been initiated to examine cohesive forces in asteroid materials to contribute to a better understanding of low density bodies such as asteroids and Phobos, and assist in exploration missions involving interaction with their surface material. The test specimen used in this study was a lightly weathered CM2 meteorite which is spectroscopically similar to Type C (carbonaceous) asteroids, and thought to have representative surface chemistry. To account for sample heterogeneity, adhesion forces were measured between the CM2 sample and its five primary mineral phase components. These adhesive forces bound the range of cohesive force that can be expected for the bulk material. All materials were characterized using a variety of optical and spectroscopic methods. Adhesive forces on the order of 50 to 400 μN were measured using a torsion balance in an ultrahigh vacuum chamber. The mineral samples exhibited clearly different adhesive strengths in the following hierarchy: Serpentine > Siderite > Bronzite > Olivine ≈ Fe-Ni.

Asteroids↗

Biophysical Characterization of Iron-Sulfur Proteins

Iron-sulfur proteins are primordial catalysts and biological electron carriers that today drive major metabolic pathways across all forms of life. They can access a diversity of oxidation states and can mediate electron transfer over an extended range of reduction potentials spanning more than 1 V. Depending on the protein micro-environment and geometry of ligand, co-ordination the iron-sulfur clusters can occur in different forms [2Fe-2S], [3Fe-4S], HiPIP [4Fe-4S], and [4Fe-4S]. There are several spectroscopic methods available to characterize the composition and electronic configuration of the iron-sulfur clusters, such as optical methods and electron paramagnetic resonance. This paper presents the protocols used to characterize the metal center of Coiled-Coil Iron-Sulfur (CCIS), an artificial metalloprotein containing one [4Fe-4S] cluster. It is expected that these protocols will be of general utility for other iron-sulfur proteins.

Iron-sulfur proteins↗

Microbial Pigments and Their Degradation Products as Biosignatures

Carotenoids are a class of vibrant biological pigments that have a characteristic chemical structure centered around a polyene core (Lu et al. 2018). Carotenoids and their derivatives are candidate biosignatures because they can persist in the terrestrial geologic record for up to 1.73 billion years (Vinnichenko et al. 2020), have specific structures that are likely the result of complex pathways, mediate the survival of many microorganisms in Mars and Ocean Worlds analog environments, and are detectable with multiple techniques, including Raman spectroscopy. In this project, we aim to investigate the detectability of carotenoid pigments with different spectroscopic methods to inform future instrument selection. We compare the spectra of five unaltered carotenoids, two model compounds, and carotenoid-forming archaeon with visible and deep UV Raman spectroscopy and UVVis absorption spectrophotometry. We then use one model pigment, beta-carotene, to evaluate the likelihood that unique spectral properties of carotenoids, or their refractory byproducts, would be preserved and detectable on a remote planetary surface by exposing it to simulated conditions for Mars. Sample Acquisition. Pigments betacarotene, lutein, zeaxanthin, astaxanthin, and lycopene were purchased from Sigma Aldrich. Halobacterium salinarum NRC-1 was acquired from Carlina Biological and grown in Halobacterium media. Mineral salts including sodium sulfate, sodium carbonate, and halite were used to form matrices in which the beta-carotene was embedded before exposure. Pigment-mineral mixes were at a 1:10 ratio in water. Analytical Techniques. Deep UV Raman data were collected on a custom laboratory mapping spectrometer called MOBIUS (Mineral and Organic Based Investigations using Ultraviolet Spectroscopy), which is an analog to the SHERLOC instrument on the Mars 2020 Perseverance rover (Bhartia et al. 2021). It features a 248.56 nm NeCu pulsed laser, liquid nitrogen-cooled detector, and tunable optical setup. Visible Raman data were collected using a Horiba Jobin Yvon LabRam HR spectrometer with a frequencydoubled Nd:YAG laser (532 nm) and a HeNe laser (633 nm). A VWR 6300 PC UV/Visible Spectrophotometer was used to collect absorption data for carotenoid solutions, model compounds, and solvents in UVpermissible capped cuvettes. Data were collected from 190-1100 nm at 1 nm increments. All spectral data were analyzed using Igor Pro 9 (Wavemetrics). Irradiation. We used a vacuum chamber equipped with a cryostat and a flood electron gun to simulate Martian surface temperatures, low pressures, and ionizing radiation (10keV, 10μA for 6h at 200K for our initial tests). The samples were prepared by drying the pigment-mineral mix onto polished metal tabs, then mounted on the cryostat for processing. Samples were then analyzed directly on the tabs after exposure. Results: In comparing the visible and deep UV Raman spectra of unaltered pigments, we found that they differed drastically. Carotenoids are often studied with visible Raman and typically have peaks at 1525 cm-1 and 1157 cm-1, due to the stretching of the C=C and C-C bonds in the polyene structure. However, in deep UV, the strongest feature is at ~1630 cm-1 and is broad, possibly indicating that multiple peaks are forming this feature. This stark difference is likely due to different preresonant enhancement effects. The UV-Vis results show that there is an absorption band in the deep UV <300 nm, which supports the hypothesis that the 248.6 nm excitation is interrogating another aspect of carotenoids than visible Raman. Our preliminary exposure tests indicated that pigments – even without minerals present - were largely unaltered in the applied conditions, with only a slight broadening in the primary polyene peaks apparent in the visible Raman data. Figure 1. A) Visible vs. deep UV Raman spectra of unaltered beta carotene. B) Schematic of exposure. Conclusions: Our results to date indicate that deep UV and visible Raman spectroscopy, both techniques with planetary mission heritage from Mars 2020 (Wiens et al. 2021, Bhartia et al. 2021), may be used in a complementary manner to observe carotenoids. In addition, we find that beta-carotene is largely resistant to our current exposure conditions, though there may be some amount of amorphization of the material which could cause the broadening of the peaks at 1525 and 1157 cm-1. As a next step, we aim to increase the dosage and duration of exposure to observe degradation of the parent pigment, possibly add UV as a factor via an Ar mini-arc UV lamp and use GC-MS to characterize possible degradation products.

pigments↗

Atacama Cosmology Telescope A Measurement of Galaxy Cluster Temperatures Through Relativistic Corrections to the Thermal Sunyaev-Zeldovich Effect

The high electron temperature in galaxy clusters (> 1 keV or > 107 K) leads to corrections at the level of a few percent in their thermal Sunyaev-Zeldovich effect signatures. Both the size and frequency dependence of these corrections, which are known as relativistic temperature corrections, depend upon the temperature of the objects. In this work we exploit this effect to measure the average temperature of a stack of Compton-y selected clusters. Specifically, we apply the “spectroscopic method” and search for the temperature that best fits the clusters’ signal measured at frequencies from 30 to 545 GHz by the Atacama Cosmology Telescope and Planck satellite. We measure the average temperature of clusters detected in the Atacama Cosmology Telescope maps to be 8.5 2.4 keV, with an additional systematic error of comparable amplitude dominated by passband uncertainty. Upcoming surveys, such as the Simons Observatory and CMB-S4, have the potential to dramatically improve upon these measurements and thereby enable precision studies of cluster temperatures with millimeter observations. The key challenge for future observations will be mitigating instrumental systematic effects, which already limit this analysis.

William R Coulton↗

Infrared and Raman Imaging of Heterogeneous Catalysts

The miniaturization of in situ spectroscopic tools has been recognized as a forefront instrumental development for the characterization of heterogeneous catalysts. With the multitude of micro-spectroscopic methods available fundamental insight into the structure-function relationships of catalytic processes can be obtained. Among these techniques vibrational spectroscopy is one of the most versatile methods and capable to shed insight into the molecular structure of reaction intermediates and products, the chemical state of catalyst materials during reaction as well as the nature of interactions between reactants/intermediates/products and the catalyst surface. In this tutorial review we discuss the recent developments in the field of infrared (IR) and Raman micro-spectroscopy and illustrate their potential. Showcase examples include (1) chemical imaging of spatial heterogeneities during catalyst preparation, (2) high-throughput catalyst screening, (3) transport and adsorption phenomena within catalytic solids and (4) reactivity studies of porous oxides, such as zeolites. Finally, new in situ spectroscopy tools based on vibrational spectroscopy and their potential in the catalysis domain are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Participation of Glutamate-354 of the CP43 Polypeptide in the Ligation of Mn and the Binding of Substrate Water in Photosystem II

In the current X-ray crystallographic structural models of photosystem II, Glu354 of the CP43 polypeptide is the only amino acid ligand of the oxygen-evolving Mn4Ca cluster that is not provided by the D1 polypeptide. To further explore the influence of this structurally unique residue on the properties of the Mn4Ca cluster, the CP43-E354Q mutant of the cyanobacterium Synechocystis sp. PCC 6803 was characterized with a variety of biophysical and spectroscopic methods, including polarography, EPR, X-ray Absorption, FTIR, and mass spectrometry. The kinetics of oxygen release in the mutant were essentially unchanged from those in wild-type. In addition, the oxygen flash-yields exhibited normal period-four oscillations having normal S state parameters, although the yields were lower, correlating with the mutant?s lower steady-state rate (approx. 20percent compared to wild-type). Experiments conducted with H218O showed that the fast and slow phases of substrate water exchange in CP43-E354Q thylakoid membranes were accelerated 8.5- and 1.8-fold, respectively, in the S3 state compared to wild-type. Purified oxygen-evolving CP43-E354Q PSII core complexes exhibited a slightly altered S1 state Mn-EXAFS spectrum, a slightly altered S2 state multiline EPR signal, a substantially altered S2-minus-S1 FTIR difference spectrum, and an unusually long lifetime for the S2 state (> 10 hours) in a substantial fraction of reaction centers. In contrast, the S2 state Mn-EXAFS spectrum was nearly indistinguishable from that of wild-type. The S2-minus-S1 FTIR difference spectrum showed alterations throughout the amide and carboxylate stretching regions. Global labeling with 15N and specific labeling with L-[1-13C]alanine revealed that the mutation perturbs both amide II and carboxylate stretching modes and shifts the symmetric carboxylate stretching modes of the ?-COO? group of D1-Ala344 (the C-terminus of the D1 polypeptide) to higher frequencies by 3 ? 4 cm-1 in both the S1 and S2 states. The EPR and FTIR data implied that 76 -82 percent of CP43-E354Q PSII centers can achieve the S2 state and that most of these can achieve the S3 state, but no evidence for advancement beyond the S3 state was observed in the FTIR data, at least not in a majority of PSII centers. Although the X-ray absorption and EPR data showed that the CP43-E354Q mutation only subtly perturbs the structure and spin state of the Mn4Ca cluster in the S2 state, the FTIR and H218O exchange data show that the mutation strongly influences other properties of the Mn4Ca cluster, altering the response of numerous carboxylate and amide groups to the increased positive charge that develops on the cluster during the S1 to S2 transition and weakening the binding of both substrate water molecules (or water derived ligands), especially the one that exchanges rapidly in the S3 state. The FTIR data provide evidence that CP43-Glu354 coordinates to the Mn4Ca cluster in the S1 state as a bridging ligand between two metal ions, but provide no compelling evidence that this residue changes its coordination mode during the S1 to S2 transition. The H218O exchange data provide evidence that CP43-Glu354 interacts with the Mn ion that ligates the substrate water molecule (or water-derived ligand) that is in rapid exchange in the S3 state.

59 BASIC BIOLOGICAL SCIENCES↗

Microchip and wedge ion funnels and planar ion beam analyzers using same

Electrodynamic ion funnels confine, guide, or focus ions in gases using the Dehmelt potential of oscillatory electric field. New funnel designs operating at or close to atmospheric gas pressure are described. Effective ion focusing at such pressures is enabled by fields of extreme amplitude and frequency, allowed in microscopic gaps that have much higher electrical breakdown thresholds in any gas than the macroscopic gaps of present funnels. The new microscopic-gap funnels are useful for interfacing atmospheric-pressure ionization sources to mass spectrometry (MS) and ion mobility separation (IMS) stages including differential IMS or FAIMS, as well as IMS and MS stages in various configurations. In particular, "wedge" funnels comprising two planar surfaces positioned at an angle and wedge funnel traps derived therefrom can compress ion beams in one dimension, producing narrow belt-shaped beams and laterally elongated cuboid packets. This beam profile reduces the ion density and thus space-charge effects, mitigating the adverse impact thereof on the resolving power, measurement accuracy, and dynamic range of MS and IMS analyzers, while a greater overlap with coplanar light or particle beams can benefit spectroscopic methods.

47 OTHER INSTRUMENTATION↗

Infrared Spectroscopy of Explosives Residues: Measurement Techniques and Spectral Analysis

Infrared laser spectroscopy of explosives is a promising technique for standoff and non-contact detection applications. However, the interpretation of spectra obtained in typical standoff measurement configurations presents numerous challenges. Understanding the variability in observed spectra from explosives residues and particles is crucial for design and implementation of detection algorithms with high detection confidence and low false alarm probability. We discuss a series of infrared spectroscopic techniques applied toward measuring and interpreting the reflectance spectra obtained from explosives particles and residues. These techniques utilize the high spectral radiance, broad tuning range, rapid wavelength tuning, high scan reproducibility, and low noise of an external cavity quantum cascade laser (ECQCL) system developed at Pacific Northwest National Laboratory. The ECQCL source permits measurements in configurations which would be either impractical or overly time-consuming with broadband, incoherent infrared sources, and enables a combination of rapid measurement speed and high detection sensitivity. The spectroscopic methods employed include standoff hyperspectral reflectance imaging, quantitative measurements of diffuse reflectance spectra, reflection-absorption infrared spectroscopy, microscopic imaging and spectroscopy, and nano-scale imaging and spectroscopy. Measurements of explosives particles and residues reveal important factors affecting observed reflectance spectra, including measurement geometry, substrate on which the explosives are deposited, and morphological effects such as particle shape, size, orientation, and crystal structure.

explosives detection↗

Spectroscopic analysis and control

Apparatus for spectroscopic analysis which includes a tunable diode laser spectrometer having a digital output signal and a digital computer for receiving the digital output signal from the spectrometer, the digital computer programmed to process the digital output signal using a multivariate regression algorithm. In addition, a spectroscopic method of analysis using such apparatus. Finally, a method for controlling an ethylene cracker hydrogenator.

36 MATERIALS SCIENCE↗

Exploring the speciation of actinide salts in the presence of contaminants related to molten salt reactors

Molten salt reactors (MSR) are up-and-coming Generation IV nuclear reactors with either coolant and/or radioactive fuel in molten salt form. Due to their improved safety, efficiency, affordability and convenient waste processing system, these reactors are considered a superior alternative to conventional ones. However, prior to commercial implementation, it is necessary to have an extensive understanding of the reactions occurring in the MSR. The safety parameters of the MSR are determined by the rheological properties such as density and viscosity of the molten salt and these properties are governed by the local structure of the molten salts. Due to the high operational temperatures of MSR's, corrosion plays an important role. Because of their influence, the container corrosion products become part of the fuel salt matrix. In this work, we are investigating how these corrosion products, e.g., Mo, Ni, Cr, would impact the speciation of the actinide metal centers. For the initial studies, lanthanides are used as a surrogate for actinides. Lanthanide chloride salts (LnCl3) are mixed with transition metals and excess of alkali or alkali earth metal salts or salt mixtures (LiCl, NaCl, KCl). These are added to an alumina crucible, placed in a quartz tube, and sealed under a vacuum. This is heated up to around 1000 °C and slowly cooled to a temperature above the melting point of the salt and at that temperature, the reaction is taken out of the furnace. The excess salt is removed, and the resulting product is analyzed using X-ray diffraction techniques, scanning electron microscopy, and spectroscopic methods such as Raman, UV-Visible, and FTIR spectroscopy.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

X-Ray Spectroscopy of the Photosynthetic Oxygen-Evolving Complex

Water oxidation to dioxygen in photosynthesis is catalyzed by a Mn{sub 4}Ca cluster with O bridging in Photosystem II (PS II) of plants, algae and cyanobacteria. A variety of spectroscopic methods have been applied to analyzing the participation of the complex. X-ray spectroscopy is particularly useful because it is element-specific, and because it can reveal important structural features of the complex with high accuracy and identify the participation of Mn in the redox chemistry. Following a brief history of the application of X-ray spectroscopy to PS II, an overview of newer results will be presented and a description of the present state of our knowledge based on this approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mixed Valent Sites in Biological Electron Transfer

Many of the active sites involved in electron transfer (ET) in biology have more than one metal and are mixed valent in at least one redox state. These include Cu(A), and the polynuclear Fe-S clusters which vary in their extent of delocalization. In this tutorial review the relative contributions to delocalization are evaluated using S K-edge X-ray absorption, magnetic circular dichroism and other spectroscopic methods. The role of intra-site delocalization in ET is considered.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the Circular Dichroism of Electronic Transitions

This chapter describes the measurement of circular dichroism (CD) for absorption due to transitions between two distinct electronic states. This is distinguished from absorption of lower energy photons, which are associated with changes of only the vibrational modes of the absorber and from the absorption of higher energy photons, which may result in ionizations. From the instrumental viewpoint, the chapter describes the measurement of CD that can be recorded using a photomultiplier or avalanche photodiode to quantify the intensity of a light beam, a photoelastic modulator to periodically alter the beam's polarization, and a monochromator located between the light source and the modulator. Using either criterion, the focus is on the spectral domain spanning about a decade in wavelength (photon energy) from roughly 1.2 {micro}m (1 eV {approx} 160 zJ) in the near infrared to 120 nm (10 eV {approx} 1.6 aJ) in the vacuum ultraviolet (VUV). In the near infrared, there is overlap between the domain of electronic and purely vibrational transitions, the use of photomultipliers or avalanche photodiodes versus solid state detectors and dispersive versus Fourier-transform spectrometers. There is also some overlap in the VUV with synchrotron beamlines that use arrays of magnets called 'insertion devices' to cause the emitted synchrotron radiation to be elliptically polarized. To my knowledge, no single spectrometer spans this entire spectral domain discussed here, and the vast majority of laboratory instruments come nowhere close to either the upper or lower limit. However, similar analytical approaches and types of instrumentation are employed throughout this spectral domain and thus are logically treated together. The focus in this chapter is on the measurement of CD resulting from the inherent chirality of the absorbing system. Several spectroscopic methods that are closely related in terms of science or instrumentation are treated in other chapters. These include magnetic circular dichroism (MCD), linear dichroism (LD), optical rotary dispersion (ORD), fluorescence detected circular dichroism (FDCD), and circularly polarized luminescence (CPL). A basic CD instrument of the type described here can be configured by temporary alterations of the sample compartment, an additional or repositioned detector and modified electronics to perform many of the important experiments in the visible and UV regions. These include unpolarized absorption and total fluorescence in addition to most of the experiments mentioned above. Except for absorption, such extensions of the basic technology will not be discussed here. Other reviews of instrumentation related to CD have appeared, some containing information complementary to that included here.

43 PARTICLE ACCELERATORS↗

Modified Fowler-Milne method for the spectroscopic determination of thermal plasma temperature without the measurement of continuum radiation

A technique based on the Fowler-Milne method for the spectroscopic determination of thermal plasma temperatures without measuring continuum radiation is presented. This technique avoids the influence of continuum radiation with the combined line and continuum emission coefficients to derive the plasma temperatures. The amount of continuum emission coefficient is estimated by using an expression related to the Biberman factors. Parameters that affect the accuracy of the proposed technique and errors in the measured plasma temperatures are analyzed. It is shown that, by using the Ar I 696.5 nm line with a bandwidth of 3.27 nm without taking into account the continuum radiation, the plasma temperature measured will be lower on the order of up to 1000-3000 K for temperatures from 20 000 to 24 000 K. The theoretically predicted temperature errors are in good agreement with the experimental results, indicating that the proposed technique is reliable for plasma temperature measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Forensic characterization of surrogate nuclear explosion debris: radiochemical and spectroscopic strategies for method validation

Surrogate nuclear explosion debris (SNED) has emerged as a critical platform for advancing post-detonation nuclear forensic analysis in the absence of readily accessible historic materials. SNED enables controlled investigation and validation of analytical methodologies used to interrogate the chemical, isotopic, radiological, and microstructural signatures preserved in nuclear explosion debris. This review presents an integrated assessment of destructive and non-destructive analytical techniques commonly employed within decision-driven nuclear forensic workflows. Each technique is discussed individually while highlighting how it contributes to different stages of post-detonation analysis. Core methods – including gamma and alpha spectrometry, ICP-MS, TIMS, SIMS, SEM-EDS, XRF, LIBS, vibrational spectroscopy, and X-ray absorption spectroscopy – are critically evaluated with respect to forensic maturity, information content, and matrix limitations. Emphasis is placed on the role of SNED in benchmarking multi-modal workflows and identifying gaps in reproducing heterogeneity, fractionation, and radiation-driven evolution relevant to forensic attribution.

X-ray spectroscopic methods↗