Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A SEARCH FOR POINT SOURCES OF EeV NEUTRONS

A thorough search of the sky exposed at the Pierre Auger Cosmic Ray Observatory reveals no statistically significant excess of events in any small solid angle that would be indicative of a flux of neutral particles from a discrete source. The search covers from -90 Degree-Sign to +15 Degree-Sign in declination using four different energy ranges above 1 EeV (10{sup 18} eV). The method used in this search is more sensitive to neutrons than to photons. The upper limit on a neutron flux is derived for a dense grid of directions for each of the four energy ranges. These results constrain scenarios for the production of ultrahigh energy cosmic rays in the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Retrospective neutron spectrum determination of a (30 MeV D, Be) source using the multi-foil activation technique and STAYSL-PNNL [Characterization of neutron spectra from a (30 MeV d, Be) source using the multi-foil activation technique]

Retrospective characterization of a (30 MeV D, Be) neutron source was performed employing multi-foil activation and STAYSL-PNNL. Experimental reaction rates were calculated from gamma spectroscopy measurements of irradiated foils and MCNP provided the guess spectrum. Adjusted spectra were evaluated through activation calculations for a stainless-steel target using FISPACT-II. Adjusted spectra showed limited dependence on the dosimetry reactions and provided minor improvements in activation calculations. Omitting reflected neutrons in the guess spectrum generated poor activation results and the limited number of dosimetry reactions introduced doubt in the adjusted spectra. Furthermore, a dedicated neutron spectrometry experiment and a more detailed simulation is required.

42 ENGINEERING↗

High-energy diffraction microscopy at the advanced photon source

The status of the High Energy Diffraction Microscopy (HEDM) program at the 1-ID beam line of the Advanced Photon Source is reported. HEDM applies high energy synchrotron radiation for the grain and sub-grain scale structural and mechanical characterization of polycrystalline bulk materials in situ during thermomechanical loading. Case studies demonstrate the mapping of grain boundary topology, the evaluation of stress tensors of individual grains during tensile deformation and comparison to a finite element modeling simulation, and the characterization of evolving dislocation structure. Complementary information is obtained by post mortem electron microscopy on the same sample volume previously investigated by HEDM.

43 PARTICLE ACCELERATORS↗

Comparison of photoexcited p-InAs THz radiation source with conventional thermal radiation sources

P-type InAs excited by ultrashort optical pulses has been shown to be a strong emitter of terahertz radiation. In a direct comparison between a p-InAs emitter and conventional thermal radiation sources, we demonstrate that under typical excitation conditions p-InAs produces more radiation below 1.2 THz than a globar. By treating the globar as a blackbody emitter we calibrate a silicon bolometer which is used to determine the power of the p-InAs emitter. The emitted terahertz power was found to be 98{+-}10 nW in this experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of efficiency and temperature control of induction heating vapor source on electron cyclotron resonance ion source

An electron cyclotron resonance ion source (ECRIS) is used to generate multicharged ions for many kinds of the fields. We have developed an evaporator by using induction heating method that can generate pure vapor from solid state materials in ECRIS. We develop the new matching and protecting circuit by which we can precisely control the temperature of the induction heating evaporator. We can control the temperature within {+-}15 deg. C around 1400 deg. C under the operation pressure about 10{sup -4} Pa. We are able to use this evaporator for experiment of synthesizing process to need pure vapor under enough low pressure, e.g., experiment of generation of endohedral Fe-fullerene at the ECRIS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spin exchange optical pumping based polarized {sup 3}He filling station for the Hybrid Spectrometer at the Spallation Neutron Source

The Hybrid Spectrometer (HYSPEC) is a new direct geometry spectrometer at the Spallation Neutron Source at the Oak Ridge National Laboratory. This instrument is equipped with polarization analysis capability with 60 Degree-Sign horizontal and 15 Degree-Sign vertical detector coverages. In order to provide wide angle polarization analysis for this instrument, we have designed and built a novel polarized {sup 3}He filling station based on the spin exchange optical pumping method. It is designed to supply polarized {sup 3}He gas to HYSPEC as a neutron polarization analyzer. In addition, the station can optimize the {sup 3}He pressure with respect to the scattered neutron energies. The depolarized {sup 3}He gas in the analyzer can be transferred back to the station to be repolarized. We have constructed the prototype filling station. Preliminary tests have been carried out demonstrating the feasibility of the filling station. Here, we report on the design, construction, and the preliminary results of the prototype filling station.

43 PARTICLE ACCELERATORS↗

Development of the C{sup 6+} laser ablation ion source for the KEK digital accelerator

A laser ion source that provides a fully ionized carbon ion beam is under joint development at the High Energy Accelerator Research Organization and Brookhaven National Laboratory. Long-pulse (6 ns) and short-pulse (500 ps) laser systems were tested by using them to irradiate a graphite target. Notable differences between the systems were observed in these experiments. Preliminary experimental results, such as the charge-state spectrum, beam intensity, and stability, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of a molybdenum X-pinch X-ray source as a probe source for X-ray diffraction studies

X-ray emission from a molybdenum X-pinch has been investigated as a potential probe for the high pressure states made in dynamic compression experiments. Studies were performed on a novel 300 kA, 400 ns generator which coupled the load directly to a low inductance capacitor and switch combination. The X-pinch load consisted of 4 crossed molybdenum wires of 13 μm diameter, crossed at an angle of 62°. The load height was 10 mm. An initial x-ray burst generated at the wire crossing point, radiated in the soft x-ray range (hυ < 10 keV). This was followed, 2–5 ns later, by at least one harder x-ray burst (hυ > 10 keV) whose power ranged from 1 to 7 MW. Time integrated spectral measurements showed that the harder bursts were dominated by K-alpha emission; though, a lower level, wide band continuum up to at least 30 keV was also present. Initial tests demonstrated that the source was capable of driving Laue diffraction experiments, probing uncompressed samples of LiF and aluminium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Behavior of moving plasma in solenoidal magnetic field in a laser ion source

In a laser ion source, a solenoidal magnetic field is useful to guide the plasma and to control the extracted beam current. However, the behavior of the plasma drifting in the magnetic field has not been well understood. Therefore, to investigate the behavior, we measured the plasma ion current and the total charge within a single pulse in the solenoid by changing the distance from the entrance of the solenoid to a detector. We observed that the decrease of the total charge along the distance became smaller as the magnetic field became larger and then the charge became almost constant with a certain magnetic flux density. The results indicate that the transverse spreading speed of the plasma decreased with increasing the field and the plasma was confined transversely with the magnetic flux density. We found that the reason of the confinement was not magnetization of ions but an influence induced by electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of the solenoid in various conditions of the laser ion source at Brookhaven National Laboratory

In the laser ion source (LIS) at the Brookhaven National Laboratory (BNL), a solenoid is used to guide the laser ablation plasma and modulate the extracted beam current. Many types of ion species are guided. In some cases, the plasma plume is injected into the solenoid away from the solenoidal axis. To investigate the effects of the solenoid on the beam extracted from the plasma that has different properties, the beam current was measured in the setup of the LIS at the BNL. The beam current of Li, Al, Si, Fe, and Au increased when the magnetic field was applied. For most of the species the peak current and the total charge within a single beam pulse increased around 10 times with a magnetic field less than 100 G. In addition, for some species the rate of increase of the peak currents became smaller when the magnetic flux densities were larger than certain values depending on the species. In this case, the current waveforms were distorted. At the same magnetic field value, the field was more effective on lighter species than on heavier ones. When plasma was injected offset from the axis of the solenoid, peak current and total charge became half of those without offset. The experimental data are useful for the operation of the LIS at the BNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent results and future plans for a 45 actuator adaptive x-ray optics experiment at the advanced light source

We report on the current status of the Adaptive X-ray Optics project run by Lawrence Livermore National Laboratory (LLNL). LLNL is collaborating with the Advanced Light Source (ALS) to demonstrate a near real-time adaptive X-ray optic. To this end, a custom-built 45 cm long deformable mirror has been installed at ALS beamline 5.3.1 (end station 2) for a two-year period that started in September 2014. We will outline general aspects of the instrument, present results from a recent experimental campaign and touch on future plans for the project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stripper foil failure modes and cures at the Oak Rdige Spallation Neutron Source

The Oak Ridge Spallation Neutron Source comprises a 1 GeV, 1.5 MW linear accelerator followed by an accumulator ring and a liquid mercury target. To manage the beam loss caused by the H{sup 0} excited states created during the H{sup -} charge-exchange injection into the accumulator ring, the stripper foil is located inside one of the chicane dipoles. This has some interesting consequences that were not fully appreciated until the beam power reached about 840 kW. One consequence was sudden failure of the stripper foil system due to convoy electrons stripped from the incoming H{sup -} beam, which circled around to strike the foil bracket and cause bracket failure. Another consequence is that convoy electrons can reflect back up from the electron catcher and strike the foil and bracket. An additional contributor to foil system failure is vacuum breakdown due to the charge developed on the foil by secondary electron emission. In this paper we detail these and other interesting failure mechanisms and describe the improvements we have made to mitigate them.

43 PARTICLE ACCELERATORS↗

Refurbishment of a used in-vacuum undulator from the National Synchrotron Light Source for the National Synchrotron Light Source-II ring

The National Synchrotron Light Source (NSLS) ceased operation in September 2014 and was succeeded by NSLS-II. There were four in-vacuum undulators (IVUs) in operation at NSLS. The most recently constructed IVU for NSLS was the mini-gap undulator (MGU-X25, to be renamed IVU18 for NSLS-II), which was constructed in 2006. This device was selected to be reused for the New York Structural Biology Consortium Microdiffraction beamline at NSLS-II. At the time of construction, IVU18 was a state-of-the-art undulator designed to be operated as a cryogenic permanent-magnet undulator. Due to the more stringent field quality and impedance requirements of the NSLS-II ring, the transition region was redesigned. The control system was also updated to NSLS-II specifications. As a result, this paper reports the details of the IVU18 refurbishment activities including additional magnetic measurement and tuning.

36 MATERIALS SCIENCE↗