SU-F-J-218: Predicting Radiation-Induced Xerostomia by Dosimetrically Accounting for Daily Setup Uncertainty During Head and Neck IMRT

Purpose: To determine if the accumulated parotid dosimetry using planning CT to daily CBCT deformation and dose re-calculation can predict for radiation-induced xerostomia. Methods: To track and dosimetrically account for the effects of anatomical changes on the parotid glands, we propagated physicians’ contours from planning CT to daily CBCT using a deformable registration with iterative CBCT intensity correction. A surface mesh for each OAR was created with the deformation applied to the mesh to obtain the deformed parotid volumes. Daily dose was computed on the deformed CT and accumulated to the last fraction. For both the accumulated and the planned parotid dosimetry, we tested the prediction power of different dosimetric parameters including D90, D50, D10, mean, standard deviation, min/max dose to the combined parotids and patient age to severe xerostomia (NCI-CTCAE grade≥2 at 6 mo follow-up). We also tested the dosimetry to parotid sub-volumes. Three classification algorithms, random tree, support vector machine, and logistic regression were tested to predict severe xerostomia using a leave-one-out validation approach. Results: We tested our prediction model on 35 HN IMRT cases. Parameters from the accumulated dosimetry model demonstrated an 89% accuracy for predicting severe xerostomia. Compared to the planning dosimetry, the accumulated dose consistently demonstrated higher prediction power with all three classification algorithms, including 11%, 5% and 30% higher accuracy, sensitivity and specificity, respectively. Geometric division of the combined parotid glands into superior-inferior regions demonstrated ∼5% increased accuracy than the whole volume. The most influential ranked features include age, mean accumulated dose of the submandibular glands and the accumulated D90 of the superior parotid glands. Conclusion: We demonstrated that the accumulated parotid dosimetry using CT-CBCT registration and dose re-calculation more accurately predicts for severe xerostomia and that the superior portion of the parotid glands may be particularly important in predicting for severe xerostomia. This work was supported in part by NIH/NCI under grant R42CA137886 and in part by Toshiba big data research project funds.

60 APPLIED LIFE SCIENCES↗

The possibility of identifying the spatial location of single dislocations by topo-tomography on laboratory setups

The spatial arrangement of single linear defects in a Si single crystal (input surface (111)) has been investigated by X-ray topo-tomography using laboratory X-ray sources. The experimental technique and the procedure of reconstructing a 3D image of dislocation half-loops near the Si crystal surface are described. The sizes of observed linear defects with a spatial resolution of about 10 μm are estimated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nuclear-nuclear collision centrality determination by the spectators calorimeter for the MPD setup at the NICA facility

The work conditions of the hadron calorimeter for spectators registration (Zero Degree Calorimeter, ZDC) were studied for the heavy nuclei collisions with the several GeV invariant energy. The ZDC simulations were performed for the MPD (Multi-Purpose Detector) at the NICA (Nuclotron-based Ion Collider fAcility) collider, which are under developement at the Joint Institute for Nuclear Research (JINR, Dubna). Taking into account the spectator nuclear fragments leads to a nonmonotonic dependence of the ZDC response on the impact parameter. The reason for this dependence studied with several event generators is the primary beam hole in the ZDC center. It is shown, that the ZDC signal should be combined with a data from other MPD-NICA detector subsystems to determine centrality.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of neutral-meson masses in meson-nucleus interactions at a momentum of 7 GeV/c at the Hyperon-M setup

The π{sup 0}, η, K{sup 0}, ω, and f{sub 2}(1270) masses were measured at the HYPERON-Msetup in meson-nucleus interactions at a momentum of 7 GeV/c by using six nuclear targets: Be, C, Al, Cu, Sn, and Pb. The experiment in question proved to be insensitive to the expected effects of a modification to the omega-meson mass in nuclear matter. As for the f{sub 2}(1270) meson, its mass and width values averaged over all experimental data, <##> } m } f 2 $ m{sub {f_2 }} $ m{sub f{sub 2}} </##> = 1275.8 ± 1.0(stat.) ± 0.4(syst.) MeV/c{sup 2} and <##> } }&#x0393;<!-- ?? --> } f 2 $ /Gamma {sub {f_2 }} $ Γ{sub f{sub 2}} </##> = 190.3 ± 1.9(stat.) ± 1.8(syst.) MeV/c{sup 2}, agree well with the world-average values. At the same time, our experimental data do not rule out the possible effect of an in-medium modification to the f{sub 2}(1270)-meson mass for heavy nuclei at a level better than 0.4%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of meson systems with isospin I = 3/2 at the VES setup

Preliminary results obtained by studying K{sup −}π{sup −}, K{sup −}π{sup −}π{sup 0}, and K{sup −}π{sup −}η systems in the VES experiment are presented. No statistically significant signals from possible resonances were observed in two- and three-particle mass spectra of doubly charged (sub)systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A setup for active neutron analysis of the fissile material content in fuel assemblies of nuclear reactors

An active neutron method for measuring the residual mass of {sup 235}U in spent fuel assemblies (FAs) of the IRT MEPhI research reactor is presented. The special measuring stand design and uniform irradiation of the fuel with neutrons along the entire length of the active part of the FA provide high accuracy of determination of the residual {sup 235}U content. AmLi neutron sources yield a higher effect/background ratio than other types of sources and do not induce the fission of {sup 238}U. The proposed method of transfer of the isotope source in accordance with a given algorithm may be used in experiments where the studied object needs to be irradiated with a uniform fluence.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Efficient method of gas laser pumping by an electron beam in the SIGE-1 experimental setup

Lasers, sources of coherent UV and vacuum UV radiation, plasmachemical reactors, reactors for cleaning fouled gases, etc., can be classified as devices the working medium of which is plasma formed as a result of the interaction of a high-current relativistic electronic beam with gas. Efficiency of such devices which are united under the common name 'systems of injection gas electronics' (SIGE) depends mainly on the efficiency of energy transfer from a beam to gas ({eta}g = W{sub g}/W{sub b}) and that of the transform of the energy transferred to gas into the energy of the ultimate product W{sub in} ({eta}{sub in} = W{sub in}/W{sub g}). As a special case of SIGE, an experimental bench laser is considered. The new efficient method of pumping is supposed to be implemented on this laser to optimize the energy contribution {eta}{sub g} and useful output {eta}{sub in}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large-Eddy Simulations of Marine Boundary Layer Clouds Associated with Cold-Air Outbreaks during the ACTIVATE Campaign. Part I: Case Setup and Sensitivities to Large-Scale Forcings

Large-eddy simulation (LES) is able to capture key boundary layer (BL) turbulence and cloud processes. Yet, large-scale forcing and surface turbulent fluxes of sensible and latent heat are often poorly prescribed for LESs. We derive these quantities from measurements and reanalysis obtained for two cold-air outbreak (CAO) events during Phase I of the Aerosol Cloud Meteorology Interactions over the Western Atlantic Experiment (ACTIVATE) in February–March 2020. We study the two contrasting CAO cases by performing LES and test the sensitivity of BL structure and clouds to large-scale forcings and turbulent heat fluxes. Profiles of atmospheric state and large-scale divergence and surface turbulent heat fluxes obtained from ERA5 data agree reasonably well with those derived from ACTIVATE field measurements for both cases at the sampling time and location. Therefore, we adopt the time-evolving heat fluxes, wind, and advective tendencies profiles from ERA5 data to drive the LES. We find that large-scale thermodynamic advective tendencies and wind relaxations are important for the LES to capture the evolving observed BL meteorological states characterized by the hourly ERA5 data and validated by the observations. We show that the divergence (or vertical velocity) is important in regulating the BL growth driven by surface heat fluxes in LESs. The evolution of liquid water path is largely affected by the evolution of surface heat fluxes. The liquid water path simulated in LES agrees reasonably well with the ACTIVATE measurements. This study paves the path to investigate aerosol–cloud–meteorology interactions using LES informed and evaluated by ACTIVATE field measurements.

54 ENVIRONMENTAL SCIENCES↗

Setup and verification of a SCALE/KENO platform for generic FHR benchmark calculations

The work presented in this article is preliminary to downstream analysis of a generic fluoride salt-cooled high-temperature reactor (gFHR) core performed by the University of Tennessee in collaboration with Kairos Power (KP). A Monte Carlo transport model of the publicly available gFHR equilibrium core is developed in SCALE/KENO with multigroup energy treatment. Several output quantities of interest are used to verify the simulations against a benchmark model developed by KP using the continuous energy Monte Carlo code Serpent 2. Good agreement is seen in flux and fission rate profiles with a maximum relative difference of 1.4% and 2.8% respectively. Furthermore, an effective multiplication factor bias of 44 pcm was observed between the two simulations. The fuel temperature reactivity coefficient calculated with SCALE is within uncertainty to the reference model. This verification acts as a publicly reproducible benchmark for the gFHR in SCALE/KENO. A simplified depletion model is also presented where a single fuel pebble is depleted to discharge burnup through the equilibrium core while the equilibrium core is assumed to be invariant. This method produces results that intercept the equilibrium core concentrations in every case, however, an interesting artifact of this particular depletion model is uncovered. The phenomenon is shown to be a fundamental feature of the differential rate equations and inspires questions about how this system behaves when the time evolution of the equilibrium core is considered. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data of High-Temperature Dynamic LCM Testing Setup

Data from high temperature dynamic sealing tests for various fracture widths, at various temperatures (degrees F), with 5 wt.% bentonite-based mud containing various material fiber contents, at 100 to 400 psi differential pressure. Data from pressure test and evaluation of the dynamic lost circulation materials (LCM) testing unit to reflect the condition of open and sealed fracture using fracture width of 1000 microns at 120 degrees F. Links to two papers based on the data - "Loss circulation prevention in geothermal drilling by shape memory polymer" which was published in Geothermics 89 (2021) 101943) as well as "Evaluating sealability of blended smart polymer and fiber additive for geothermal drilling with the effect of fracture opening size", published in the Journal of Petroleum Science and Engineering 206 (2021) 108998.

15 GEOTHERMAL ENERGY↗

Experimental Setup of Apodization Techniques for Beam Diagnostics Performed at ELBE

The ELBE (Electron Linac for beams with high Brilliance and low Emittance) facility in Dresden, Germany is a multipurpose user facility, which is also used for accelerator R&D purposes. The beam line was set up for transverse beam profile measurements, where the imaging system includes a series of three apodizers and five circular apertures. During beam operations both of these were changed remotely through automated LabView routines. The bunch structure and charge were varied to collect a series of images that were acquired automatically, and then stored for later analysis. Over 12,000 images were captured and then analyzed using software written at Jefferson Lab that runs ImageJ as it's main image processing library.

Freeman, B.↗

A 3% Measurement of the Beam Normal Single Spin Asymmetry in Forward Angle Elastic Electron-Proton Scattering using the Qweak Setup

The beam normal single spin asymmetry generated in the scattering of transversely polarized electrons from unpolarized nucleons is an observable of the imaginary part of the two-photon exchange process. Moreover, it is a potential source of false asymmetry in parity violating electron scattering experiments. The Q{sub weak} experiment uses parity violating electron scattering to make a direct measurement of the weak charge of the proton. The targeted 4% measurement of the weak charge of the proton probes for parity violating new physics beyond the Standard Model. The beam normal single spin asymmetry at Q{sub weak} kinematics is at least three orders of magnitude larger than 5 ppb precision of the parity violating asymmetry. To better understand this parity conserving background, the Q{sub weak} Collaboration has performed elastic scattering measurements with fully transversely polarized electron beam on the proton and aluminum. This dissertation presents the analysis of the 3% measurement (1.3% statistical and 2.6% systematic) of beam normal single spin asymmetry in electronproton scattering at a Q2 of 0.025 (GeV/c)2. It is the most precise existing measurement of beam normal single spin asymmetry available at the time. A measurement of this precision helps to improve the theoretical models on beam normal single spin asymmetry and thereby our understanding of the doubly virtual Compton scattering process.